Plan Review Details - Permit 23050475
Plan Review Stops For Permit 23050475 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2023-05-23 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2023-05-23 |
Time |
14:50 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2023-05-23 |
Time |
14:05 |
Sent To |
|
|
Notes |
2023-05-23 14:15:41 | PROVISO ON PLAN PAGE SP-1: A SEPERATE PERMIT IS | | REQUIRED FOR FENCING. CT |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2023-05-24 |
|
|
Cont ID |
|
Sent By |
mpeterso |
Date |
2023-05-24 |
Time |
12:40 |
Rev Time |
0.00 |
Received By |
mpeterso |
Date |
2023-05-24 |
Time |
12:40 |
Sent To |
|
|
Notes |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
F |
Date |
2023-05-17 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2023-05-17 |
Time |
17:38 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2023-05-17 |
Time |
16:32 |
Sent To |
|
|
Notes |
2023-05-17 17:38:51 | 1ST REVIEW FBC-2020 RES. GAS | | PERMIT- 23050475 | | 5/17/23 | | | | CODES IN EFFECT: | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION | | 2020 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) SHEET P1 GAS RISER: LABEL ALL LENGTHS OF PIPING | | SHOWN AS EITHER PE, CSST, OR SCHEDULE 40 METALLIC AND | | PROVIDE THE SIZING TABLES USED FOR EACH- SEC. G2413.4 | | FBC RES. IT IS NOT CLEAR WHERE THE UNDERGROUND PE | | TRANSITIONS TO CSST AND THE RISER SHOWS PIPING SLEEVED | | THROUGH FOOTINGS. PLEASE NOTE PE SHALL NOT BE INSTALLED | | UNDERNEATH BUILDINGS PER SEC. G2415.17.1 FBC RES. | | | | 2) P1: THE FUTURE GENERATOR EXHAUST SHALL BE LOCATED A | | MINIMUM OF 10 FT. FROM ANY OPERABLE DOOR OR WINDOW | | OPENINGS, AND GRAVITY AND MECHANICAL AIR INTAKES | | INCLUDING VENTILATED SOFFITS- SEC. R303.5.1 FBC. PLEASE | | RELOCATE THE GENERATOR AND EXTEND THE PIPING IF | | NECESSARY TO MEET COMPLIANCE. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. | | | | CHRISTOPHER L. COLE | | MECHANICAL/PLUMBING PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2023-05-31 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2023-05-31 |
Time |
16:37 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2023-05-11 |
Time |
14:31 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2023-05-31 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2023-05-31 |
Time |
16:36 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2023-05-31 |
Time |
16:19 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2023-05-17 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2023-05-17 |
Time |
17:38 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2023-05-17 |
Time |
16:32 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
P |
Date |
2023-05-23 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2023-05-23 |
Time |
14:49 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2023-05-23 |
Time |
14:05 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2023-05-16 |
|
|
Cont ID |
|
Sent By |
vbroglia |
Date |
2023-05-16 |
Time |
15:20 |
Rev Time |
0.00 |
Received By |
vbroglia |
Date |
2023-05-16 |
Time |
15:20 |
Sent To |
|
|
Notes |
2023-05-16 15:21:58 | FAILED FOR THE FOLLOWING REASON(S): | | | | 1. PLEASE NOTE IF THE ROOF OR THE STRUCTUTRE IS | | PROJECTION INTO THE FRONT AND REAR SETBACK, THE SITE | | PLAN IS UNCLEAR OF WHERE THE ROOF LINE IS AND IF THERE | | IS AN OVERHANG | | | | | | **** REVIEWD BY **** | | VALENTINA BROGLIA | | PLANNER | | [email protected] | | |
|
|
|