Plan Review Details - Permit 23050467
Plan Review Stops For Permit 23050467
Review Stop AD ADDRESSING
Rev No 2 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop AD ADDRESSING
Rev No 1 Status F Date 2023-05-19 Cont ID  
Sent By cpuell Date 2023-05-19 Time 16:10 Rev Time 0.00
Received By cpuell Date 2023-05-19 Time 16:10 Sent To  
Notes
2023-05-19 16:12:37PLANS INDICATE THAT THIS PERMIT IS TO CHANGE THE USE OF
 THE BUILDINGS FROM RESIDENTIAL TO COMMERCIAL, TWO
 BUILDING ADDRESSES IN QUESTION 618 7TH ST AND 620 7TH
 ST, SINCE WORK IS TO BE DONE IN TWO DIFFERENT BUILDINGS
 AND THE BUILDINSG WILL NOW BE COMMERCIAL AN ADDITIONAL
 PERMIT FOR THE SECOND BUILDING WILL NEED TO BE APPLIED
 FOR. PLEASE CONTACT [email protected] OR CALL
 561-805-6659

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status N Date 2023-05-30 Cont ID  
Sent By rmcphers Date 2023-05-30 Time 09:07 Rev Time 0.00
Received By rmcphers Date 2023-05-26 Time 15:38 Sent To  
Notes
2023-05-30 09:07:21NOT REQUIRED - NEW BUILDING

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2023-05-30 Cont ID  
Sent By rmcphers Date 2023-05-30 Time 09:03 Rev Time 0.00
Received By rmcphers Date 2023-05-26 Time 15:38 Sent To  
Notes
2023-05-30 09:03:23BUILD OUT
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
  
 1) DRAWING S-1 - UNDER "OCCUPANCY CLASSIFICATION" NOTE
 - SHOWS 2010 FBC - SHOULD BE 2020 FBC
  
 2) BUILDING CONSTRUCTION TYPE IS SHOWN AS V - PLEASE
 SHOW VA OR VB FBC CHAPTER 6
  
 3) PLEASE SHOW THE ACCESSIBLE BAR AREA - SHOW BAR TOP
 HEIGHT, CLEAR FLOOR SPACE, KNEE AND TOE CLEARANCE ETC.
 - FBC A 226.2 AND 902
  
 4) PLEASE SHOW THE DOOR MANUVERING SPACE TO EXIT THE
 RESTROOMS ( 18 INCH CLEARANCE FROM THE DOOR TO THE
 SINK) - FBC A 404
  
 5) PLEASE SHOW THE ACCESSIBLE SALES COUNTER HEIGHT AND
 CLEAR FLOOR SPACE IN UNIT "B" - FBC 904.4
  
 6) DRAWING S-1 SAYS FIRE SPRINKLERS - DRAWING LS - 1
 SAYS NO FIRE SPRINKLERS - UNDER OCCUPANCY NOTES -
 PLEASE CLARIFY
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2023-05-25 Cont ID  
Sent By jleahy Date 2023-05-25 Time 09:51 Rev Time 0.00
Received By jleahy Date 2023-05-25 Time 09:32 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2023-05-12 Cont ID  
Sent By pleduc Date 2023-05-12 Time   Rev Time 0.00
Received By pleduc Date 2023-05-12 Time 13:36 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By amcgrego Date 2023-07-28 Time 14:17 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2023-06-07 Cont ID  
Sent By avolcy Date 2023-06-07 Time 16:35 Rev Time 0.00
Received By avolcy Date 2023-05-11 Time 14:09 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2023-06-05 Cont ID  
Sent By cmontell Date 2023-06-05 Time 13:00 Rev Time 0.00
Received By cmontell Date 2023-06-05 Time 12:49 Sent To  
Notes
2023-06-05 13:07:38NO RETURNS ON PLANS NEED RETURN AIR PER FBC MECHANICAL
 SEC 601.6 BALANCED RETURN AIR

Review Stop P PLUMBING
Rev No 2 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2023-05-19 Cont ID  
Sent By ccole Date 2023-05-19 Time 12:12 Rev Time 0.00
Received By ccole Date 2023-05-19 Time 08:54 Sent To  
Notes
2023-05-19 12:13:331ST REVIEW FBC-2020 PLUMBING
 PERMIT- 23050467
 5/19/23
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEETS LS-1 & P100: PROVIDE PLUMBING FIXTURE
 CALCULATIONS FOR EACH BUILDING IN ACCORDANCE WITH TABLE
 403.1 FBC P. PROVIDE A SCHEDULE THAT SHOWS THE REQUIRED
 AND PROVIDED NUMBER OF FIXTURES. PLEASE NOTE MOP SINKS
 AND DRINKING FOUNTAINS ARE REQUIRED FOR BOTH BUILDINGS.
 BLDG. A IS MISSING THE DRINKING FOUNTAINS AND BLDG. B
 IS MISSING DRINKING FOUNTAINS AND MOP SINK. BLDG. A CAN
 CITE SEC. 410.4 AND PROVIDE DRINKING WATER IN A
 CONTAINER FREE OF CHARGE. IF CLAIMING THAT EXCEPTION
 PLEASE NOTE IT ON THE PLAN.
 A) CONCERNING THE DRINKING FOUNTAINS WHERE REQUIRED,
 TWO DRINKING SHALL BE PROVIDED- ONE FOR PERSONS IN
 WHEELCHAIRS, AND ONE FOR STANDING PERSONS- SEC. 410.3
 FBC P. PLEASE REVISE THE ARCHITECTURAL AND PLUMBING
 PLANS.
  
 2) S-1: AN ICE MACHINE IS SHOWN AT THE BAR HOWEVER THE
 PLUMBING PLANS DO NOT SHOW A WATER LINE OR DRAIN FOR
 THE APPLIANCE- SEC. 107.2.1 WPB.
  
 3) P100, P201, P400, & P500 GREASE INTERCEPTOR:
 COMMENTS A, B, & C BELOW SHALL ALSO APPLY TO THE
 SEPARATE GREASE INTERCEPTOR PERMIT- 22070156 WHICH IS
 STILL IN REVIEW.
 A) THE DRAINAGE FROM THE HAND SINK SHALL NOT DISCHARGE
 INTO THE GREASE WASTE INTERCEPTOR- SEC. 1003.3.1 FBC P.
 PLEASE ROUTE THE DRAINAGE TO SANITARY ALONG WITH
 DRAINAGE FROM THE ICE MACHINE- SEE COMMENT #2 ABOVE.
 B) PLEASE REMOVE THE HAND SINK FROM THE GREASE WASTE
 CALCULATIONS- SEC 1003.3.1.
 C) REFERENCE IS MADE TO A SAMPLING PORT DETAIL ON SHEET
 P0.1 WHICH IS NOT INCLUDED IN THE PLANS SETS. PLEASE
 NOTE THE CITY OF WPB UTILITIES DEPT. REQUIRES A TWO-WAY
 CLEANOUT ON THE INTERCEPTOR OUTLET PIPE TO BE USED AS A
 SAMPLING PORT.
  
 4) P500: AS A MEANS OF LIMITING THE HOT WATER
 TEMPERATURE AT THE WATER HEATER PLEASE PROVIDE AN ASSE
 1017 MASTER MIXING VALVE AT THE WATER HEATER- SEC.
 607.1.1 FBC P. PLEASE REVISE THE WATER HEATER DETAIL TO
 SHOW THE LOCATION OF THE DEVICE AND THE PIPING
 CONNECTIONS. IMPORTANT NOTE- SEC, 607.2.2 REQUIRES THE
 HWR LINE TO BE ROUTED TO THE COLD WATER INLET PIPE OF
 THE WATER HEATER AND THE COLD WATER INLET PIPE OR THE
 HOT WATER RETURN CONNECTION OF THE MIXING VALVE.
  
 5) S-1 & S-3: PLEASE SHOW THE CLEAR FLOOR SPACE
 DIAGRAMS AND DIMENSIONS FOR THE LAVATORIES TO VERIFY
 THE BATHROOM DOORS DO NOT SWING INTO THE SPACES- SEC.
 603.2.3 FBC ACC.
  
 6) S-3: PLEASE SHOW THE HEIGHTS OF THE GRAB BARS TO THE
 TOPS OF THE GRIPPING SURFACES- SEC. 609.4 FBC ACC.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2023-05-30 Cont ID  
Sent By rmcphers Date 2023-05-30 Time 09:11 Rev Time 0.00
Received By rmcphers Date 2023-05-30 Time 09:11 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2023-06-07 Cont ID  
Sent By gvolcy Date 2023-06-07 Time 16:35 Rev Time 0.00
Received By avolcy Date 2023-06-07 Time 16:35 Sent To  
Notes
***NONE***