Plan Review Details - Permit 23050132
Plan Review Stops For Permit 23050132
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status P Date 2023-06-07 Cont ID  
Sent By lbond Date 2023-06-07 Time 11:18 Rev Time 0.00
Received By lbond Date 2023-06-07 Time 11:18 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2023-06-07 Cont ID  
Sent By lbond Date 2023-06-07 Time 11:47 Rev Time 0.00
Received By lbond Date 2023-06-07 Time 11:46 Sent To  
Notes
2023-06-07 11:49:01FBC 107.1
  
  
 PROVIDE NOA OR FBC PRODUCT APPROVAL FOR GLOW DOWN WOOD
 AS WELL AS FLAME SPREAD AND SOUND TEST.
  
 LOUIS BOND, AIA
 BUILDING PLANS EXAMINER II
 DEVELOPMENT SERVICES DEPT.
 BUILDING DIVISION
 401 CLEMATIS STREET
 WEST PALM BEACH, FLORIDA 33401
 PH: 561-805-6729
 FX: 561-805-6676
 EMAIL: [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2023-05-12 Cont ID  
Sent By pleduc Date 2023-05-12 Time 11:40 Rev Time 0.00
Received By pleduc Date 2023-05-12 Time 11:40 Sent To  
Notes
2023-05-12 11:55:24THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 1) THERE IS AN INDICATION OF A GLUE DOWN WOOD FLOOR,
 BUT NO SPEC SHEET NOR A PRODUCT NAME FOR THE ACTUAL
 PROPOSED WOOD FLOORING NOR THE PROPOSED GLUE PRODUCT.
  
 WOOD FLOORING AND GLUE PRODUCTS ARE MANUFACTURED AROUND
 THE WORLD BUT NOT ALL ARE TESTED AND MEETING LISTED AND
 NFPA STANDARDS.
  
 PER NFPA 101, CH 30
  
 30.3.3.3 INTERIOR FLOOR FINISH.
 30.3.3.1 GENERAL. INTERIOR FINISH SHALL BE IN
 ACCORDANCE WITH
 SECTION 10.2.
  
 10.2.7.2* FLOOR COVERINGS, OTHER THAN CARPET FOR WHICH
 10.2.2.2
 ESTABLISHES REQUIREMENTS FOR FIRE PERFORMANCE, SHALL
 HAVE A
 MINIMUM CRITICAL RADIANT FLUX OF 0.1 W/CM2.
  
 FOR THE OFFICIAL RECORD, PLEASE PROVIDE THE PEROPSED
 WOOD FLOORING NAME AND THE PRODUCT SPEC SHEETS
 INDICATING THE FIRE BEHAVIOR RATING.
  
 IF THE PROPOSED FLOORING IS PORCELAIN/CERAMIC TILE,
 NATURAL STONE TILE, CONCRETE TILES, PRODUCT SPEC SHEETS
 WOULD NOT BE REQUIRED.
  
 PRODUCT SPEC SHEETS ARE REQUIRED FOR LVT, VINYL
 FLOORING, WOOD/VINYL LAMINATES, ETC.
  
  
  
 2) THERE IS AN INDICATION OF WORK ON A FIRE RATED
 CORRIDOR WALL IN BATHROOM.
  
 ENSURE FIRE RATED TENANT/CORRIDOR SEPARATION WALLS
 ARE MAINTAINED & REPAIRED IF DAMAGED.
  
 PROVIDE A NOTE OF ACKNOWLEDGMENT OF THE PROPOSED FLOOR
 PLAN.
  
  
 3) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET
 REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE
 ABOVE.
  
  
 4) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE
 RE-SUBMITTAL OF THE ABOVE.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  
  
  
  
  
  
  
  
  
  
  
 PROTECT FIRE SPRINKLERS AND FIRE ALARM DEVICES AND
 EQUIPMENT.
 DO NOT PAINT OVER SPRINKLER HEADS AND/OR FIRE ALARM
 DEVICES/EQUIPMENT.
 THE FS AND FA SYSTEMS SHALL BE MAINTAINED THROUGHOUT
 DEMO AND CONSTRUCTION.
 PLEASE ENSURE THE APPLICABLE PROTECTION AND PROVIDE A
 NOTE OF ACKNOWLEDGMENT ON THE FLOOR PLAN.
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2023-06-07 Cont ID  
Sent By lbond Date 2023-06-07 Time 11:57 Rev Time 0.00
Received By lbond Date 2023-05-10 Time 07:39 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2023-05-18 Cont ID  
Sent By ccole Date 2023-05-18 Time 12:50 Rev Time 0.00
Received By ccole Date 2023-05-18 Time 12:37 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2023-06-07 Cont ID  
Sent By lbond Date 2023-06-07 Time 11:46 Rev Time 0.00
Received By lbond Date 2023-06-07 Time 11:46 Sent To  
Notes
2023-06-07 11:57:40BUILDING REVIEW COMMENTS:
  
 W.P.B. PERMIT: 23050132
  
 REVIEWED: 6.7.2023
  
 FLORIDA BUILDING CODE,7TH EDITION (2020)
 FBC[AMENDED] = 2017 CHAPTER 1 WPB AMENDMENTS (SEE LINK
 BELOW)
 HTTPS://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/
 BUILDING-PERMIT-FORMS
 FBC BUILDING
 FBC EXISTING BUILDING
  
 COMMENTS:
  
 PLAN REVIEW RESULTS: DENIED
  
 1) THE PLANS SHEETS FOR THE PROJECT ARE NOT DIGITALLY
 SIGNED BY THE ARCHITECT OF RECORD AS REQUIRED BY FL.
 STATUTE AND SEC.: 61G1-16.005 FLORIDA ADMINISTRATIVE
 CODE. PLANS TRANSMITTED ELECTRONICALLY SHALL BEAR
 DIGITAL SIGNATURES AND SEALS CAPABLE OF BEING VERIFIED.
 THE PLANS SUBMITTED FOR REVIEW ARE COPIES OF A SIGNED
 AND SEALED PAPER PLANS.
  
 PLEASE UPLOAD SHEETS THAT THE DIGITAL SIGNATURE/SEAL IS
 VERIFIABLE WITH ADOBE OR BLUEBEAM REVU SOFTWARE
  
 IF YOU HAVE ANY QUESTIONS OR CONCERNS, PLEASE DO NOT
 HESITATE TO CONTACT ME
  
 LOUIS BOND, AIA
 BUILDING PLANS EXAMINER II
 DEVELOPMENT SERVICES DEPT.
 BUILDING DIVISION
 401 CLEMATIS STREET
 WEST PALM BEACH, FLORIDA 33401
 PH: 561-805-6729
 FX: 561-805-6676
 EMAIL: [email protected]
  
  
 NOTES:
 PLEASE PROVIDE COMMENT RESPONSE SHEET TO EXPLAIN HOW
 EACH COMMENT IS BEING ADDRESSED.
  