Plan Review Stops For Permit 23041516 |
Review Stop |
AD |
ADDRESSING |
Rev No |
2 |
Status |
P |
Date |
2023-06-01 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2023-06-01 |
Time |
13:46 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2023-06-01 |
Time |
13:46 |
Sent To |
|
|
Notes |
2023-06-01 13:47:02 | THIS PERMIT IS FOR THE 5TH FLOOR ONLY PER THE PROJECT | | ENGINEER |
|
|
Review Stop |
AD |
ADDRESSING |
Rev No |
1 |
Status |
F |
Date |
2023-05-16 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2023-05-16 |
Time |
12:57 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2023-05-16 |
Time |
12:57 |
Sent To |
|
|
Notes |
2023-05-16 12:59:53 | THE PLANS STATE THAT THE SCOPE OF WORK IS FOR THE 4TH | | AND 5TH FLOOR, THE APPLICATION FORM ONLY LISTS THE 5TH | | FLOOR, AND I WAS UNABLE TO FIND A PERMIT FOR THE 4TH | | FLOOR. PLEASE CONFIRM THE AREA OF WORK FOR THIS | | PROJECT. [email protected] OR CALL 561-805-6659 |
|
|
Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
Rev No |
2 |
Status |
N |
Date |
2023-06-16 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2023-06-16 |
Time |
14:42 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2023-06-16 |
Time |
14:42 |
Sent To |
|
|
Notes |
2023-06-16 14:42:53 | SEE DEMO PERMIT 22030863 |
|
|
Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
Rev No |
1 |
Status |
F |
Date |
2023-05-30 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2023-05-30 |
Time |
11:37 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2023-05-30 |
Time |
11:37 |
Sent To |
|
|
Notes |
2023-05-30 11:38:09 | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | CONTRACTOR, ON LETTERHEAD, STATING THAT THE | | INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM | | COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH | | COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE | | GIVEN TIMELY. | | | | ADDITIONAL INFORMATION REGARDING ASBESTOS REQUIREMENTS | | CAN BE FOUND ON THEIR WEBSITE: | | | | HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE | | S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION- | | RENOVATION.HTML | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2023-06-16 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2023-06-16 |
Time |
14:39 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2023-06-16 |
Time |
14:39 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2023-05-30 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2023-05-30 |
Time |
11:37 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2023-05-30 |
Time |
11:28 |
Sent To |
|
|
Notes |
2023-05-30 11:37:17 | REMODEL | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected] | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | AMENDMENT | | | | CORRECTIONS NEEDED - | | | | 1) ACCESSIBLE RESTROOM = PLEASE USE THE WORDS | | "REFLECTIVE SURFACE" WHEN REFERRING TO THE DIMENSIONS | | FROM THE FLOOR TO THE BOTTOM OF THE MIRROR (REFLECTIVE | | SURFACE) - FBC 603.3 MIRRORS. | | MIRRORS LOCATED ABOVE LAVATORIES OR COUNTERTOPS SHALL | | BE INSTALLED WITH THE BOTTOM EDGE OF THE REFLECTING | | SURFACE 40 INCHES (1015 MM) MAXIMUM ABOVE THE FINISH | | FLOOR OR GROUND. | | | | 2) PLEASE SHOW THE TOILET SIDE WALL FINISH TO COMPLY | | WITH - FBC 1210.2.2 WALLS AND PARTITIONS. | | WALLS AND PARTITIONS WITHIN 2 FEET (610 MM) OF SERVICE | | SINKS, URINALS AND WATER CLOSETS SHALL HAVE A SMOOTH, | | HARD, NONABSORBENT SURFACE, TO A HEIGHT OF NOT LESS | | THAN 4 FEET (1219 MM) ABOVE THE FLOOR, (DRYWALL IS NOT | | CONSIDERED A HARD SURFACE) | | | | 3) PLEASE SHOW THE WALL FINISH SURROUNDING THE MOP SINK | | TO COMPLY WITH - FBC 1210.2.2 WALLS AND PARTITIONS. | | WALLS AND PARTITIONS WITHIN 2 FEET (610 MM) OF SERVICE | | SINKS, URINALS AND WATER CLOSETS SHALL HAVE A SMOOTH, | | HARD, NONABSORBENT SURFACE, TO A HEIGHT OF NOT LESS | | THAN 4 FEET (1219 MM) ABOVE THE FLOOR, (DRYWALL IS NOT | | CONSIDERED A HARD SURFACE) |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2023-05-25 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2023-05-25 |
Time |
09:17 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2023-05-25 |
Time |
08:16 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2023-06-14 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2023-06-14 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2023-06-14 |
Time |
10:27 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2023-05-15 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2023-05-15 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2023-05-12 |
Time |
13:58 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2023-06-29 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2023-06-29 |
Time |
08:39 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2023-06-13 |
Time |
09:27 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2023-06-05 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2023-06-05 |
Time |
17:34 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2023-05-11 |
Time |
11:01 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2023-06-29 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2023-06-29 |
Time |
08:39 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2023-06-29 |
Time |
08:34 |
Sent To |
|
|
Notes |
2023-06-29 08:39:37 | PASS PROVISO | | REFER TO SECTION 601.5 RETURN AIR OPENING # 7. | | RETURN AIR SHALL NOT BE TAKEN FROM TOILET ROOMS. | | 2020 FBC (M). | | PLAN REVIEW BY HAROLD MOSER | | [email protected] | | OFFICE 561-805-6732 | | FAX 561-805-6676 | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2023-06-05 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2023-06-05 |
Time |
17:34 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2023-06-05 |
Time |
17:13 |
Sent To |
|
|
Notes |
2023-06-05 17:34:11 | PLAN DENIED | | REFER TO SECTION 601.5 RETURN AIR OPENINGS # 7 | | RETUEN AIR SHALL NOT BE TAKEN FROM A TOLET ROOM. | | 2020 FBC (M) | | PLAN REVIEW BY HAROLD MOSER | | [email protected] | | OFFICE 561-805-6732 | | FAX 561-805-6676 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2023-06-16 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2023-06-16 |
Time |
09:48 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2023-06-16 |
Time |
09:32 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2023-05-19 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2023-05-19 |
Time |
08:28 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2023-05-19 |
Time |
07:54 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2023-06-16 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2023-06-16 |
Time |
14:43 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2023-06-16 |
Time |
14:43 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
P |
Date |
2023-05-19 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2023-05-19 |
Time |
08:31 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2023-05-19 |
Time |
08:31 |
Sent To |
|
|
Notes |
|
|