Plan Review Details - Permit 23041203
Plan Review Stops For Permit 23041203
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2023-05-17 Cont ID  
Sent By pvalenti Date 2023-05-17 Time 13:26 Rev Time 0.00
Received By pvalenti Date 2023-05-17 Time 11:16 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2023-05-03 Cont ID  
Sent By jbrooks Date 2023-05-03 Time 13:54 Rev Time 0.00
Received By jbrooks Date 2023-05-03 Time 08:19 Sent To  
Notes
2023-05-03 13:54:30JONATHAN BROOKS JR.
 BUILDING PLANS EXAMINER
 WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM
 PHONE (561) 805-6656
 EMAIL: [email protected]
  
 1ST REVIEW: FBC 2020 7TH EDITION
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
 TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT
 CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX.
  
 1. FBC B 107.2.1 1 PROVIDE THE FOLLOWING ADDITIONAL
 INFORMATION FOR EACH PERMIT APPLICATION: AERIAL MAP OF
 THE ENTIRE COMPLEX WITH EACH BUILDING CLEARLY
 IDENTIFIED BY NUMBER; EACH PERMIT APPLICATION SHOULD
 ALSO REFLECT THE BUILDING NUMBER TO BE REROOFED.
 2. FBC B 107.2.1 SUBMITTED PRODUCT APPROVAL FL18355-R7
 HAS BEEN REVISED TO FL18355-R8. PLEASE PROVIDE A
 COMPLETE SET TO INCLUDE COVER PAGES; IT COVERS MULTIPLE
 PRODUCTS & INSTALLATION METHODS. SELECT PRODUCT &
 INSTALLATION METHOD TO BE USED. ALL APPLICABLE DETAILS
 AND ATTACHMENTS MUST BE CLEARLY IDENTIFIED ON THE
 PRODUCT APPROVAL DRAWINGS.
 3. FBC B 107.2.1 SUBMITTED PRODUCT APPROVAL FL2569-R24
 COVERS MULTIPLE PRODUCT TYPES; ROOF COVER OPTIONS;
 ALLOWABLE UNDERLAYMENT/TILE-ADHESIVE COMBINATIONS,
 ALLOWABLE SUBSTRATES & ATTACHMENT LIMITATIONS. SELECT
 ATTACHMENT LIMITATIONS TO BE USED. ALL APPLICABLE
 DETAILS AND ATTACHMENTS MUST BE CLEARLY IDENTIFIED ON
 THE PRODUCT APPROVAL DRAWINGS.
 4. FBC B 107.2.1 FOR CLARITY PLEASE REVISE ROOF
 DIAGRAM/SKETCH AND INCLUDE ROOF SLOPE(S), MEAN ROOF
 HEIGHT(S).
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2023-05-17 Cont ID  
Sent By pvalenti Date 2023-05-17 Time 13:26 Rev Time 0.00
Received By pvalenti Date 2023-05-10 Time 09:36 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2023-05-03 Cont ID  
Sent By jbrooks Date 2023-05-03 Time 13:54 Rev Time 0.00
Received By jbrooks Date 2023-05-02 Time 10:59 Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved