Plan Review Stops For Permit 23041004 |
Review Stop |
AD |
ADDRESSING |
Rev No |
1 |
Status |
P |
Date |
2023-05-12 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2023-05-12 |
Time |
15:15 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2023-05-12 |
Time |
15:15 |
Sent To |
|
|
Notes |
2023-05-12 15:15:51 | PARCEL READDRESSED 825 835 & 845 N RAILROAD AVE |
|
|
Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
Rev No |
1 |
Status |
P |
Date |
2023-06-12 |
|
|
Cont ID |
|
Sent By |
lbond |
Date |
2023-06-12 |
Time |
14:03 |
Rev Time |
0.00 |
Received By |
lbond |
Date |
2023-06-12 |
Time |
14:03 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2023-07-18 |
|
|
Cont ID |
|
Sent By |
lbond |
Date |
2023-07-18 |
Time |
13:23 |
Rev Time |
0.00 |
Received By |
lbond |
Date |
2023-07-18 |
Time |
13:23 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2023-06-13 |
|
|
Cont ID |
|
Sent By |
lbond |
Date |
2023-06-13 |
Time |
13:29 |
Rev Time |
0.00 |
Received By |
lbond |
Date |
2023-06-13 |
Time |
13:29 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2023-07-28 |
|
|
Cont ID |
|
Sent By |
mpeterso |
Date |
2023-07-28 |
Time |
15:23 |
Rev Time |
0.00 |
Received By |
mpeterso |
Date |
2023-07-28 |
Time |
15:23 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2023-05-31 |
|
|
Cont ID |
|
Sent By |
mpeterso |
Date |
2023-05-31 |
Time |
08:41 |
Rev Time |
0.00 |
Received By |
mpeterso |
Date |
2023-05-31 |
Time |
08:35 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2023-07-12 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2023-07-12 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2023-07-12 |
Time |
15:42 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2023-05-10 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2023-05-10 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2023-05-08 |
Time |
13:41 |
Sent To |
|
|
Notes |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
2 |
Status |
N |
Date |
2023-07-21 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2023-07-21 |
Time |
17:23 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2023-07-21 |
Time |
17:23 |
Sent To |
|
|
Notes |
2023-07-21 17:24:36 | SEPARATE PERMIT REQUIRED FOR GAS. |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
F |
Date |
2023-05-30 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2023-05-30 |
Time |
15:21 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2023-05-30 |
Time |
15:21 |
Sent To |
|
|
Notes |
2023-05-30 15:21:41 | 1ST REVIEW FBC-2020 FUEL GAS | | PERMIT- 23041004 | | 5/30/2023 | | | | CODES IN EFFECT: | | FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) SHEETS P-100 & P-500: PROVIDE A GAS RISER DRAWING | | FOR THE NEW SYSTEM- SEC. 107.3.5.1.5 WPB. PLEASE NOTE | | THAT GAS CAN BE DONE UNDER A SEPARATE PERMIT BY | | REQUEST. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. | | | | CHRISTOPHER L. COLE | | MECHANICAL/PLUMBING PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
|
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
Received By |
amcgrego |
Date |
2023-07-11 |
Time |
09:55 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2023-06-15 |
|
|
Cont ID |
|
Sent By |
cmontell |
Date |
2023-06-15 |
Time |
10:52 |
Rev Time |
0.00 |
Received By |
cmontell |
Date |
2023-06-15 |
Time |
10:51 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2023-06-13 |
|
|
Cont ID |
|
Sent By |
lbond |
Date |
2023-06-13 |
Time |
13:29 |
Rev Time |
0.00 |
Received By |
lbond |
Date |
2023-06-13 |
Time |
13:29 |
Sent To |
|
|
Notes |
2023-06-13 13:30:17 | BUILDING REVIEW COMMENTS: | | | | W.P.B. PERMIT: 23041004 | | | | REVIEWED: 6.13.2023 | | | | FLORIDA BUILDING CODE,7TH EDITION (2020) | | FBC[AMENDED] = 2017 CHAPTER 1 WPB AMENDMENTS (SEE LINK | | BELOW) | | HTTPS://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/ | | BUILDING-PERMIT-FORMS | | FBC BUILDING | | FBC EXISTING BUILDING | | | | COMMENTS: | | | | 109 FBC[AMENDED] PLANS WILL BE REVIEWED BY THE PBC | | IMPACT FEE OFFICE DIGITALLY VIA PROJECTDOX UPON | | NOTIFICATION BY THIS OFFICE. NOTIFICATION MAY OCCUR | | WHEN PLANS ARE NEAREST FINAL FORM. YOU MAY COORDINATE | | WITH THE IMPACT FEE OFFICE AT (561) 233-5025 OR SIMPLY | | UPLOAD THE MUNICIPAL IMPACT FEE QUESTIONNAIRE FORM TO | | YOUR PROJECT AND NAME THE FILE MUNICIPAL IMPACT FEE | | QUESTIONNAIRE. THE FORM CAN BE FOUND AT: HTTP://DISCOVE | | R.PBCGOV.ORG/PZB/ADMINISTRATION/PDF/IMPACTFEES/FORMS/QU | | ESTIONNAIRE.PDF UPON APPROVAL AND FEE PAYMENT, PLEASE | | UPLOAD THE RECEIPT TO YOUR PROJECT OR EMAIL IT TO | | [email protected] | | | | | | | | IF YOU HAVE ANY QUESTIONS OR CONCERNS, PLEASE DO NOT | | HESITATE TO CONTACT ME | | | | LOUIS BOND, AIA | | BUILDING PLANS EXAMINER II | | DEVELOPMENT SERVICES DEPT. | | BUILDING DIVISION | | 401 CLEMATIS STREET | | WEST PALM BEACH, FLORIDA 33401 | | PH: 561-805-6729 | | FX: 561-805-6676 | | EMAIL: [email protected] | | | | NOTES: | | PLEASE PROVIDE COMMENT RESPONSE SHEET TO EXPLAIN HOW | | EACH COMMENT IS BEING ADDRESSED. | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2023-07-17 |
|
|
Cont ID |
|
Sent By |
jbaker |
Date |
2023-07-17 |
Time |
12:46 |
Rev Time |
0.00 |
Received By |
jbaker |
Date |
2023-07-17 |
Time |
12:45 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2023-06-15 |
|
|
Cont ID |
|
Sent By |
cmontell |
Date |
2023-06-15 |
Time |
10:51 |
Rev Time |
0.00 |
Received By |
cmontell |
Date |
2023-06-15 |
Time |
10:51 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2023-07-21 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2023-07-21 |
Time |
17:24 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2023-07-21 |
Time |
17:24 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2023-05-30 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2023-05-30 |
Time |
14:59 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2023-05-30 |
Time |
14:59 |
Sent To |
|
|
Notes |
2023-05-30 15:03:48 | 1ST REVIEW FBC-2020 PLUMBING | | PERMIT- 23041004 | | 5/30/23 | | | | CODES IN EFFECT: | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) P-100: SEPARATE PERMITS ARE REQUIRED FOR THE POTABLE | | WATER BACKFLOW PREVENTER AND THE GREASE INTERCEPTOR. AT | | A MINIMUM, THE PERMIT APPLICATIONS FOR EACH SHALL BE | | SUBMITTED PRIOR TO MAIN PLUMBING PLAN APPROVAL. IF | | CONTRACTORS ARE NOT CURRENTLY SELECTED FOR EACH | | INSTALLATION, PERMIT APPLICATIONS CAN BE SUBMITTED TBD | | (TO BE DETERMINED). EACH COMPLETED APPLICATION SHALL BE | | EMAILED TO [email protected] . YOU WILL THEN | | RECEIVE INSTRUCTIONS TO PAY FEES AND UPLOAD PLANS. YOU | | MAY UPLOAD PLANS AND PAY FEES AT A FUTURE DATE, BUT THE | | APPLICATIONS ARE REQUIRED AT THIS TIME. WE RECOMMEND | | THAT YOU PAY FEES AND UPLOAD PLANS AT THE SAME TIME. | | AFTER YOU HAVE THE PERMIT(S) GENERATED, NOTIFY ME VIA | | EMAIL AND I WILL CHANGE THE REVIEW STATUS TO PASS. | | | | 2) P100: KEYNOTES 2, 3, 5, 8, & 10 REFER TO CIVIL | | DRAWINGS WHICH WERE NOT UPLOADED FOR REVIEW. PLEASE | | PROVIDE THE DRAWINGS- SEC. 107.2.1 WPB. | | | | 3) P-102: PROVIDE GUTTER AND DOWNSPOUT SIZES- TABLES | | 1106.3 & 1106.6 FBC P. | | | | 4) P-501: A MEANS OF LIMITING THE HOT WATER TEMPERATURE | | AT THE WATER HEATER OTHER THAN THE THERMOSTAT IS | | REQUIRED IN COMPLIANCE WITH SEC. 607.1.1 FBC P. PLEASE | | PROVIDE A MASTER THERMOSTATIC MIXING VALVE AND SHOW THE | | PIPING CONNECTIONS IN THE DETAIL. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. | | | | CHRISTOPHER L. COLE | | MECHANICAL/PLUMBING PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2023-07-18 |
|
|
Cont ID |
|
Sent By |
lbond |
Date |
2023-07-18 |
Time |
13:29 |
Rev Time |
0.00 |
Received By |
lbond |
Date |
2023-07-18 |
Time |
13:29 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
P |
Date |
2023-05-31 |
|
|
Cont ID |
|
Sent By |
mpeterso |
Date |
2023-05-31 |
Time |
08:41 |
Rev Time |
0.00 |
Received By |
mpeterso |
Date |
2023-05-31 |
Time |
08:41 |
Sent To |
|
|
Notes |
2023-05-31 08:41:50 | ALL PLANS PASSED SIGNATURE REVIEW. MP | 2023-05-30 14:32:04 | PLUMBING SIGNATURES PASSED. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
|
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
Received By |
|
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2023-05-30 |
|
|
Cont ID |
|
Sent By |
ckimmerl |
Date |
2023-05-30 |
Time |
10:00 |
Rev Time |
0.00 |
Received By |
ckimmerl |
Date |
2023-05-30 |
Time |
10:00 |
Sent To |
|
|
Notes |
|
|