Plan Review Stops For Permit 23040946 |
Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
Rev No |
1 |
Status |
P |
Date |
2023-05-02 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2023-05-02 |
Time |
09:21 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2023-05-02 |
Time |
08:46 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2023-06-29 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2023-06-29 |
Time |
09:28 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2023-06-29 |
Time |
09:28 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2023-06-08 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2023-06-08 |
Time |
13:36 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2023-06-08 |
Time |
07:58 |
Sent To |
|
|
Notes |
2023-06-08 08:00:17 | PETER E VALENTI | | BUILDING PLANS EXAMINER II/INSPECTOR | | [email protected] | | 561 805 6673 | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | FBC B = FBC BUILDING | | FBC R = FBC RESIDENTIAL | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC M = FBC MECHANICAL | | FBC FG = FBC FUEL GAS | | | | BUILDING REVIEW DENIED: | | | | | | 2.) FBC 603.1,(ITEM 2, EXCEPTION 2), PROVIDE THE FLAME | | SPREAD TEST REPORT FOR FLOORING UNDERLAYMENT. ALLOWABLE | | MATERIALS IN NON COMBUSTIBLE BUILDINGS, ACOUSTICAL | | INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID | | DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED | | TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200. SEE | | 803.1.1, PROVIDE TEST DATA IN ACCORDANCE WITH ASTM E 84 | | OR UL 723. | | PLEASE IDENTIFY THE UNDERLAYMENT THAT YOU ARE PROPOSING | | TO USE AS THERE ARE (2) DIFFERENT UNDERLAYMENTS | | (PROFLEX LV200) & (PROTECTO WRAP WHISPERMAT CS). | | PLEASE CONFIRM THAT YOU WOULD LIKE TO REMOVE PROTECTO | | WRAP WHISPER MAT CS FROM THE APPLICATION. | | | | 3.) CITY OF WPB AMENDMENTS TO FBC B 107.2.1, PROVIDE | | THE CONTRACTOR'S SIGNATURE ON ALL SUBMITTED PLAN SHEETS | | BY THE CONTRACTOR. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2023-05-02 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2023-05-02 |
Time |
09:30 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2023-05-02 |
Time |
08:46 |
Sent To |
|
|
Notes |
2023-05-02 10:12:32 | PETER E VALENTI | | BUILDING PLANS EXAMINER II/INSPECTOR | | [email protected] | | 561 805 6673 | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | FBC B = FBC BUILDING | | FBC R = FBC RESIDENTIAL | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC M = FBC MECHANICAL | | FBC FG = FBC FUEL GAS | | | | BUILDING REVIEW DENIED: | | | | 1.) FBC B 107.2.1,PROVIDE AN ENGINEER'S LETTER WITH THE | | X-RAY REPORT SHOWING THE SLAB PENETRATION CLEARANCE OF | | EXISTING REINFORCEMENT/P.T. CABLES FOR THE NEW SHOWER | | DRAIN. | | | | 2.) FBC 603.1,(ITEM 2, EXCEPTION 2), PROVIDE THE FLAME | | SPREAD TEST REPORT FOR FLOORING UNDERLAYMENT. ALLOWABLE | | MATERIALS IN NON COMBUSTIBLE BUILDINGS, ACOUSTICAL | | INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID | | DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED | | TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200. SEE | | 803.1.1, PROVIDE TEST DATA IN ACCORDANCE WITH ASTM E 84 | | OR UL 723. | | | | 3.) CITY OF WPB AMENDMENTS TO FBC B 107.2.1, PROVIDE | | THE CONTRACTOR'S SIGNATURE ON ALL SUBMITTED PLAN SHEETS | | BY THE CONTRACTOR. | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2023-05-10 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2023-05-10 |
Time |
15:21 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2023-05-10 |
Time |
15:16 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
P |
Date |
2023-06-28 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2023-06-28 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2023-06-28 |
Time |
09:42 |
Sent To |
|
|
Notes |
2023-06-28 09:42:56 | FIRE PROVISO: | | | | ENSURE FIRE RATED TENANT/CORRIDOR SEPARATION WALLS | | ARE MAINTAINED & REPAIRED IF DAMAGED. | | | | PETER LEDUC | | FIRE MARSHAL | | 561-804-4709 | | [email protected] | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2023-05-31 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2023-05-31 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2023-05-31 |
Time |
12:11 |
Sent To |
|
|
Notes |
2023-05-31 12:13:03 | FIRE PROVISO: | | | | ENSURE FIRE RATED TENANT/CORRIDOR SEPARATION WALLS | | ARE MAINTAINED & REPAIRED IF DAMAGED. | | | | PETER LEDUC | | FIRE MARSHAL | | 561-804-4709 | | [email protected] | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2023-04-27 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2023-04-27 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2023-04-27 |
Time |
14:57 |
Sent To |
|
|
Notes |
2023-04-27 14:58:46 | FIRE PROVISO: | | | | ENSURE FIRE RATED TENANT/CORRIDOR SEPARATION WALLS | | ARE MAINTAINED & REPAIRED IF DAMAGED. | | | | PETER LEDUC | | FIRE MARSHAL | | 561-804-4709 | | [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2023-06-29 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2023-06-29 |
Time |
09:35 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2023-06-22 |
Time |
17:29 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2023-06-08 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2023-06-08 |
Time |
14:19 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2023-05-30 |
Time |
17:41 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2023-05-15 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2023-05-15 |
Time |
17:13 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2023-04-25 |
Time |
10:35 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2023-06-29 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2023-06-29 |
Time |
09:32 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2023-06-29 |
Time |
09:28 |
Sent To |
|
|
Notes |
2023-06-29 09:34:59 | PETER E VALENTI | | BUILDING PLANS EXAMINER II/INSPECTOR | | [email protected] | | 561 805 6673 | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | FBC B = FBC BUILDING | | FBC R = FBC RESIDENTIAL | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC M = FBC MECHANICAL | | FBC FG = FBC FUEL GAS | | | | MECHANICAL REVIEW APPROVED AS NO NEW MECHANICAL WORK IS | | REQUIRED. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2023-06-08 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2023-06-08 |
Time |
14:04 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2023-06-08 |
Time |
14:04 |
Sent To |
|
|
Notes |
2023-06-08 14:10:17 | PETER E VALENTI | | BUILDING PLANS EXAMINER II/INSPECTOR | | [email protected] | | 561 805 6673 | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | FBC B = FBC BUILDING | | FBC R = FBC RESIDENTIAL | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC M = FBC MECHANICAL | | FBC FG = FBC FUEL GAS | | | | MECHANICAL REVIEW DENIED: | | | | FBC B 107.2.1, FBC R M303.3 & FBC R M303.4, PLEASE | | STATE ON PLANS THAT THERE IS NO MECHANICAL WORK | | PROPOSED FOR THIS PROJECT AND THAT THE EXISTING | | VENTILLATION IS BY MECHANICAL VENTILATION OR BY NATURAL | | VENTILATION THROUGH EXISTING WINDOWS AT BATHROOMS. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2023-05-15 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2023-05-15 |
Time |
17:02 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2023-05-15 |
Time |
17:02 |
Sent To |
|
|
Notes |
2023-05-15 17:12:17 | PLAN DENIED | | 1) PLAN DOES NOT SHOW WINDOWS OR PATHROOM EXHAUST | | REFER TO SECTION R303.3 BATHROOMS. AND | | R303.4 MECHANICAL VENTILATION 2020 FBC RESIDENTIAL | | CODE. | | PLAN REVIEW BY HAROLD MOSER | | [email protected] | | OFFICE 561-805-6732 | | FAX 561-805-6676 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2023-06-26 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2023-06-26 |
Time |
08:27 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2023-06-26 |
Time |
08:24 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2023-06-01 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2023-06-01 |
Time |
11:31 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2023-06-01 |
Time |
11:08 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2023-05-01 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2023-05-01 |
Time |
10:56 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2023-05-01 |
Time |
10:56 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
N |
Date |
2023-05-02 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2023-05-02 |
Time |
10:45 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2023-05-02 |
Time |
08:46 |
Sent To |
|
|
Notes |
|
|