Plan Review Stops For Permit 23040387 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2023-07-19 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2023-07-19 |
Time |
16:08 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2023-07-19 |
Time |
16:08 |
Sent To |
|
|
Notes |
2023-07-19 16:29:23 | PLAN | | REVIEW COMMENTS | | | | 2ND REVIEW: FBC SEVENTH EDITION (2020) | | ROBERT MCDOUGAL, CBO | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561) 805-6714 | | [email protected] | | | | DENIED BY BUILDING | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | 1) RESOLVED. | | | | 2) RESOLVED. | | | | 3) NOT RESOLVED. [THERE IS NO VEHICLE CHARGING STATION | | SHOWN AT THE ACCESSIBLE CUSTOMER PARKING SPACES ON THE | | SURVEY. AT LEAST ONE OF THE ACCESSIBILE CUSTOMER SPACES | | IS REQUIRED TO HAVE A CHARGING STATION.] SHOW HOW THE | | CAR CHARGING STATIONS AND PARKING COMPLY WITH FBC | | ACCESSIBILITY. NOTE: THE BUILDING OFFICIAL HAS | | DETERMINED THAT ACCESSIBLE CHARGING STATIONS ARE TO BE | | PROVIDED BASED ON THE NUMBER OF CHARGING STATIONS | | PROVIDED AT EACH LOCATION USING FBC ACCESSIBILITY TABLE | | 208.2. IF THERE ARE BETWEEN 1 - 25 PARKING SPACES | | PROVIDED WITH CHARGING STATIONS, THEN 1 SUCH SPACE MUST | | BE ACCESSIBLE. ADVISORY 208.2 MINIMUM NUMBER. THE TERM | | "PARKING FACILITY" IS USED IN SECTION 208.2 INSTEAD OF | | THE TERM "PARKING LOT" SO THAT IT IS CLEAR THAT BOTH | | PARKING LOTS AND PARKING STRUCTURES ARE REQUIRED TO | | COMPLY WITH THIS SECTION. THE NUMBER OF PARKING SPACES | | REQUIRED TO BE ACCESSIBLE IS TO BE CALCULATED | | SEPARATELY FOR EACH PARKING FACILITY; THE REQUIRED | | NUMBER IS NOT TO BE BASED ON THE TOTAL NUMBER OF | | PARKING SPACES PROVIDED IN ALL OF THE PARKING | | FACILITIES PROVIDED ON THE SITE. | | | | 4) WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A | | RESPONSE LETTER ADDRESSING EACH ITEM ALONG WITH THE | | CITY RE-SUBMITTAL FORM. | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2023-04-21 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2023-04-21 |
Time |
15:41 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2023-04-21 |
Time |
15:40 |
Sent To |
|
|
Notes |
2023-04-21 15:58:07 | PLAN | | REVIEW COMMENTS | | | | 1ST REVIEW: FBC SEVENTH EDITION (2020) | | ROBERT MCDOUGAL, CBO | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561) 805-6714 | | [email protected] | | | | DENIED BY BUILDING | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | 1) SUBMIT A SITE PLAN THAT SHOWS THE LOCATIONS OF THE | | ELECTRIC VEHICLE CHARGING STATIONS. FBC AMENDMENTS | | 107.2.1 | | | | 2) SPECIFY INTENDED USERS OF THE CAR CHARGING STATIONS. | | FOR EXAMPLE ARE THEY FOR THE USE OF THE RESIDENTS, | | GUESTS, EMPLOYEES, FLEET VEHICLES, CUSTOMERS, ETC. FBC | | AMENDMENTS 107.2.1 | | | | 3) SHOW HOW THE CAR CHARGING STATIONS AND PARKING | | COMPLY WITH FBC ACCESSIBILITY. NOTE: THE BUILDING | | OFFICIAL HAS DETERMINED THAT ACCESSIBLE CHARGING | | STATIONS ARE TO BE PROVIDED BASED ON THE NUMBER OF | | CHARGING STATIONS PROVIDED AT EACH LOCATION USING FBC | | ACCESSIBILITY TABLE 208.2. IF THERE ARE BETWEEN 1 - 25 | | PARKING SPACES PROVIDED WITH CHARGING STATIONS, THEN 1 | | SUCH SPACE MUST BE ACCESSIBLE. ADVISORY 208.2 MINIMUM | | NUMBER. THE TERM "PARKING FACILITY" IS USED IN SECTION | | 208.2 INSTEAD OF THE TERM "PARKING LOT" SO THAT IT IS | | CLEAR THAT BOTH PARKING LOTS AND PARKING STRUCTURES ARE | | REQUIRED TO COMPLY WITH THIS SECTION. THE NUMBER OF | | PARKING SPACES REQUIRED TO BE ACCESSIBLE IS TO BE | | CALCULATED SEPARATELY FOR EACH PARKING FACILITY; THE | | REQUIRED NUMBER IS NOT TO BE BASED ON THE TOTAL NUMBER | | OF PARKING SPACES PROVIDED IN ALL OF THE PARKING | | FACILITIES PROVIDED ON THE SITE. | | | | 4) WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A | | RESPONSE LETTER ADDRESSING EACH ITEM ALONG WITH THE | | CITY RE-SUBMITTAL FORM. | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2023-07-10 |
|
|
Cont ID |
|
Sent By |
jcooley |
Date |
2023-07-10 |
Time |
17:32 |
Rev Time |
0.00 |
Received By |
jcooley |
Date |
2023-07-10 |
Time |
17:06 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2023-04-17 |
|
|
Cont ID |
|
Sent By |
jcooley |
Date |
2023-04-17 |
Time |
17:33 |
Rev Time |
0.00 |
Received By |
jcooley |
Date |
2023-04-17 |
Time |
17:29 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2023-07-19 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2023-07-19 |
Time |
16:08 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2023-07-03 |
Time |
10:00 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2023-04-24 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2023-04-24 |
Time |
12:24 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2023-04-10 |
Time |
11:41 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2023-07-19 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2023-07-19 |
Time |
15:57 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2023-07-19 |
Time |
15:57 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
P |
Date |
2023-04-21 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2023-04-21 |
Time |
15:41 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2023-04-21 |
Time |
15:41 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2023-07-10 |
|
|
Cont ID |
|
Sent By |
kdefranc |
Date |
2023-07-10 |
Time |
08:45 |
Rev Time |
0.00 |
Received By |
kdefranc |
Date |
2023-07-10 |
Time |
08:44 |
Sent To |
|
|
Notes |
2023-07-10 08:44:57 | 7/10/23 ??? FAILED | | | | REVIEW COMMENT TO BE ADDRESSED: | | 1. PLEASE PROVIDE A CURRENT SURVEY OF THE SUBJECT | | PROPERTY. [SATISFIED] | | 2. PLEASE DEMONSTRATE/INDICATE THE PROPOSED SETBACK | | DIMENSIONS OF THE PROPOSED ELECTRICAL FACILITIES (FPL | | TRANSFORMER, PANELS, AND EV CHARGERS) FROM THE NORTH | | AND WEST PROPERTY LINES ON THE SURVEY AND ELECTRICAL | | SITE PLAN. [NOT SATISFIED] | | | | | | | | KEVIE DEFRANC | | SENIOR PLANNER ??? PLANNING DIVISION | | [email protected] | | 561-822-1449 | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2023-04-24 |
|
|
Cont ID |
|
Sent By |
KDefranc |
Date |
2023-04-24 |
Time |
12:21 |
Rev Time |
0.00 |
Received By |
kdefranc |
Date |
2023-04-24 |
Time |
12:21 |
Sent To |
|
|
Notes |
2023-04-24 12:21:37 | 4/24/23 ??? FAILED | | | | REVIEW COMMENT TO BE ADDRESSED: | | 1. PLEASE PROVIDE A CURRENT SURVEY OF THE SUBJECT | | PROPERTY. | | 2. PLEASE DEMONSTRATE/INDICATE THE PROPOSED SETBACK | | DIMENSIONS OF THE PROPOSED ELECTRICAL FACILITIES (FPL | | TRANSFORMER, PANELS, AND EV CHARGERS) FROM THE NORTH | | AND WEST PROPERTY LINES ON THE SURVEY AND ELECTRICAL | | SITE PLAN. | | | | | | | | KEVIE DEFRANC | | SENIOR PLANNER ??? PLANNING DIVISION | | [email protected] | | 561-822-1449 | | |
|
|