Plan Review Details - Permit 23040327
Plan Review Stops For Permit 23040327
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status P Date 2023-04-26 Cont ID  
Sent By lbond Date 2023-04-26 Time 15:21 Rev Time 0.00
Received By lbond Date 2023-04-26 Time 15:21 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2023-05-11 Cont ID  
Sent By lbond Date 2023-05-11 Time 10:15 Rev Time 0.00
Received By lbond Date 2023-05-11 Time 10:15 Sent To  
Notes
2023-05-11 10:23:11PROVISO
 THE ELEVATION TAG ON DETAIL B SHEET ID-3 IS NOT
 CONSISTENT WITH THE ELEVATIONS BELOW.
  
 CLEARLY DETAIL THE STEP TO ACCESS THE SHOWER
 PLEASE COORDINATE ELEVATIONS AND SECTIONS TO MATCH.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2023-04-26 Cont ID  
Sent By lbond Date 2023-04-26 Time 15:22 Rev Time 0.00
Received By lbond Date 2023-04-26 Time 15:22 Sent To  
Notes
2023-04-26 15:27:45 
 ADDING A SHOWER DRAIN OUTLET MAY REQUIRE THE FLOOR TO
 BE X-RAYED TO IN ORDER TO LOCATE REINFORCING STEEL OR
 POST STRESSED FLOOR TENDONS.
 PLEASE PLACE A NOTE ON THE PLANS TO VERIFY COMPLIANCE
 WILL BE MET- SECTION 107.2.1 WPB.
  
 IF YOU HAVE ANY QUESTION OF CONCERNS, PLEASE DO NOT
 HESITATE TO CONTACT US
  
 LOUIS BOND, AIA
 BUILDING PLANS EXAMINER II
 DEVELOPMENT SERVICES DEPT.
 BUILDING DIVISION
 401 CLEMATIS STREET
 WEST PALM BEACH, FLORIDA 33401
 PH: 561-805-6729
 FX: 561-805-6676
 EMAIL: [email protected]
  
  
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2023-05-08 Cont ID  
Sent By jleahy Date 2023-05-08 Time 10:54 Rev Time 0.00
Received By jleahy Date 2023-05-08 Time 10:34 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2023-05-11 Cont ID  
Sent By pleduc Date 2023-05-11 Time   Rev Time 0.00
Received By pleduc Date 2023-05-11 Time 11:25 Sent To  
Notes
2023-05-11 11:25:51FIRE PROVISO:
  
 ENSURE FIRE RATED TENANT/CORRIDOR SEPARATION WALLS
 ARE MAINTAINED & REPAIRED IF DAMAGED.
  
 PROTECT FIRE SPRINKLERS AND FIRE ALARM DEVICES AND
 EQUIPMENT.
  
 DO NOT PAINT OVER SPRINKLER HEADS AND/OR FIRE ALARM
 DEVICES/EQUIPMENT.
  
 THE FS AND FA SYSTEMS SHALL BE MAINTAINED THROUGHOUT
 DEMO AND CONSTRUCTION.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2023-04-26 Cont ID  
Sent By pleduc Date 2023-04-26 Time   Rev Time 0.00
Received By pleduc Date 2023-04-26 Time 14:10 Sent To  
Notes
2023-04-26 14:15:34FIRE PROVISO:
  
 ENSURE FIRE RATED TENANT/CORRIDOR SEPARATION WALLS
 ARE MAINTAINED & REPAIRED IF DAMAGED.
  
 PROTECT FIRE SPRINKLERS AND FIRE ALARM DEVICES AND
 EQUIPMENT.
  
 DO NOT PAINT OVER SPRINKLER HEADS AND/OR FIRE ALARM
 DEVICES/EQUIPMENT.
  
 THE FS AND FA SYSTEMS SHALL BE MAINTAINED THROUGHOUT
 DEMO AND CONSTRUCTION.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2023-05-12 Cont ID  
Sent By rwbrown Date 2023-05-12 Time 09:01 Rev Time 0.00
Received By rwbrown Date 2023-05-10 Time 08:49 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2023-05-08 Cont ID  
Sent By jleahy Date 2023-05-08 Time 10:55 Rev Time 0.00
Received By jleahy Date 2023-04-20 Time 12:52 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2023-05-12 Cont ID  
Sent By rwbrown Date 2023-05-12 Time 09:01 Rev Time 0.00
Received By rwbrown Date 2023-05-12 Time 09:01 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2023-04-21 Cont ID  
Sent By rwbrown Date 2023-04-21 Time 11:48 Rev Time 0.00
Received By rwbrown Date 2023-04-21 Time 11:48 Sent To  
Notes
2023-04-21 11:50:531ST PLUMBING REVIEW
  
 THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED
 BY RYAN BROWN WITH THE FOLLOWING COMMENTS.
  
 1. 2017 WPB AMENDS 107.3.5.1.3 - PLEASE INCLUDE A RISER
 THAT SHOWS THE NEW PLUMBING CONNECTIONS TO THE SANITARY
 SYSTEM.
  
 2. 2020 FPC 315.1 - AS A NOTE, NEW PENETRATIONS THROUGH
 FLOORS, WALLS, AND CEILING ARE LIKELY TO NEED UL LISTED
 FIRE STOPPING DETAILS AND SHOULD BE INCLUDED IN THE
 STRUCTURAL PAGES.
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
  
 RYAN W. BROWN
 CHIEF PLUMBING INSPECTOR
 OFFICE: 561-805-6692
 CELL: 561-517-4293
 EMAIL: [email protected]
  
  
 V7 FPC - 2020 FLORIDA PLUMBING CODE
 V7 FGC - 2020 FLORIDA FUEL GAS
 V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE
 V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE
 V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE
 V7 FEC - 2020 FLORIDA ENERGY CONSERVATION
 2021 F.S. - 2021 FLORIDA STATUTES
 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE
 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE
 FBC CHAPTER 1
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2023-05-11 Cont ID  
Sent By lbond Date 2023-05-11 Time 09:00 Rev Time 0.00
Received By lbond Date 2023-05-11 Time 09:00 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2023-04-26 Cont ID  
Sent By lbond Date 2023-04-26 Time 15:19 Rev Time 0.00
Received By lbond Date 2023-04-26 Time 15:19 Sent To  
Notes
***NONE***