Plan Review Details - Permit 23031350
Plan Review Stops For Permit 23031350
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2023-04-07 Cont ID  
Sent By jbrooks Date 2023-04-07 Time 14:02 Rev Time 0.00
Received By jbrooks Date 2023-04-07 Time 12:46 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2023-03-27 Cont ID  
Sent By jbrooks Date 2023-03-27 Time 11:10 Rev Time 0.00
Received By jbrooks Date 2023-03-27 Time 07:42 Sent To  
Notes
2023-03-27 11:10:51JONATHAN BROOKS JR.
 BUILDING PLANS EXAMINER
 WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM
 PHONE (561) 805-6656
 EMAIL: [email protected]
  
 1ST REVIEW: FBC 2020 7TH EDITION
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
 TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT
 CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX.
  
 1. FBC B 107.2.1. SUBMITTED FLORIDA DBPR PRODUCT
 APPROVAL FL10497-R8 HAS BEEN REVISED TO FL10497-R9.
 PLEASE PROVIDE THE FOLLOWING: COVER PAGE, EVALUATION
 REPORT PAGES 1-4 AND INSTALLATION INSTRUCTIONS FOR
 SYSTEM USED. ALL APPLICABLE DETAILS AND ATTACHMENTS
 MUST BE CLEARLY IDENTIFIED ON THE PRODUCT APPROVAL
 DRAWINGS.
 2. FBC B 107.2.1 SUBMITTED PRODUCT APPROVAL FL5259-R35
 HAS BEEN REVISED TO FL5259-R37. PLEASE PROVIDE A
 COMPLETE SET TO INCLUDE COVER PAGE(S); IT COVERS
 MULTIPLE PRODUCT TYPES; ROOF COVER OPTIONS; ALLOWABLE
 UNDERLAYMENT/TILE-ADHESIVE COMBINATIONS, ALLOWABLE
 SUBSTRATES & ATTACHMENT LIMITATIONS. SELECT OPTIONS
 FROM EACH CATEGORY TO BE USED; SELECT FROM TABLE 4A
 DIRECT-TO-DECK UNDERLAYMENT IN TILE ROOF APPLICATIONS
 OR TABLE 4B 2-PLY UNDERLAYMENT SYSTEMS IN TILE ROOF
 APPLICATIONS. ALL APPLICABLE DETAILS AND ATTACHMENTS
 MUST BE CLEARLY IDENTIFIED ON THE PRODUCT APPROVAL
 DRAWINGS.
 3. FBC B 107.2.1 PLEASE NOTE: PRODUCT APPROVAL
 FL5259-R37 (NON-HVHZ) TABLES 4A & 4B, ALLOWABLE DESIGN
 PRESSURE UNDERLAYMENT CHARTS ARE REQUIRED FOR USE IN
 ROOF TILE APPLICATIONS ONLY.
 4. FBC B 107.2.1 FOR CLARITY PLEASE REVISE ROOF
 DIAGRAM/SKETCH AND INCLUDE FLAT ROOF SLOPE(S), MEAN
 ROOF HEIGHT(S). FLAT/LOW SLOPE ROOFS MUST SHOW POSITIVE
 DRAINAGE.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2023-04-07 Cont ID  
Sent By jbrooks Date 2023-04-07 Time 14:02 Rev Time 0.00
Received By jbrooks Date 2023-03-31 Time 09:28 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2023-03-27 Cont ID  
Sent By jbrooks Date 2023-03-27 Time 11:10 Rev Time 0.00
Received By jbrooks Date 2023-03-24 Time 09:16 Sent To  
Notes
***NONE***