Plan Review Details - Permit 23031314
Plan Review Stops For Permit 23031314
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2023-07-21 Cont ID  
Sent By rbrown Date 2023-07-21 Time 18:52 Rev Time 0.00
Received By rbrown Date 2023-07-21 Time 18:52 Sent To  
Notes
2023-07-21 19:02:00THE COMMENTS FROM THE 6/21/23 BUILDING PLAN REVIEW MUST
 BE ADDRESSED. HOWEVER, THE COMMENT ABOUT THE PROJECT
 VALUATION IS BEING UPDATED WITH THIS REVIEW AS FOLLOWS:
  
 THE PROJECT IS NOT NEW CONSTRUCTION. IT IS AN ADDITION,
 SO ONE WALL AND SOME OF THE BUILDING SYSTEMS, AND THE
 SITE WORK ALREADY EXISTS. WILL REDUCE THE SQUARE FOOT
 COST FROM $167.37 PER S.F. DOWN TO $100 PER S.F. SO THE
 ESTIMATED PROJECT VALUATION IS ($100/SF X 854 SF) +
 ($66.48/SF X 100 SF) = $92,048
  
 **QUOTE PERMIT# ON ALL CORRESPONDENCE**
  
 ROBERT BROWN
 E-MAIL: [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2023-06-26 Cont ID  
Sent By lbond Date 2023-06-21 Time 16:44 Rev Time 0.00
Received By lbond Date 2023-06-21 Time 16:44 Sent To  
Notes
2023-06-21 16:50:15BUILDING REVIEW COMMENTS:
 W.P.B. PERMIT:23051177
 REVIEWED: 6.23.2023
  
 FLORIDA BUILDING CODE,7TH EDITION (2020)
 FBC[AMENDED] = 2017 CHAPTER 1 WPB AMENDMENTS (SEE LINK
 BELOW)
 HTTPS://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/
 BUILDING-PERMIT-FORMS
 FBC BUILDING
 FBC EXISTING BUILDING
  
  
 SHEET A-1
  
 DESIGN CRITERIA UPDATE ROOFING MATERIAL TO FLAT ROOF
  
 SHEET A-2
  
  [A]109.1 UPDATED FEES, REFER TO COVER SHEET.
  
  ICC TABLE IS $167.37 PER S.F. FOR AREA UNDER AC VB
 CONSTRUCTION:
 YOU ARE ADDING 854 SF = $142,933.98
  ICC TABLE IS $66.48 PER S.F. FOR UTILITY OR
 MISCELLANEOUS: YOU ARE ADDING 100 S.F. =$ 6,648.00
  
  GRAND TOTAL PERMIT VALUE: $149,581.98
  
 WINDOWS AND DOORS SCHEDULE
  
  AS PER FBC 1030.2 EGRESS WINDOW MIN IS 5.7. S.F.
  WINDOW B IN CABANA BEDROOM NO COMPLYING- PLEASE
 PROVIDE COMPLYING WINDOW SIZE AND ADJUST ELEVATIONS,
 DESIGN PRESSURE, AND WINDOW SCHEDULE ACCORDINGLY.
  PROVIDE NOA FOR NEW EXTERIOR DOORS 1,2,3 AND DESIGN
 PRESSURES
  
 SHEET A-4
  
 TYP. WALL SECTION A
 DRAW EXACT AS BUILT CONDITION TO SCALE AND CALL OUT
 NOTE THAT ARE COORDINATED WITH DESIGN ELEMENTS.
  FASCIA AND RAFTER DIMENSIONS DO NOT MATCH- TYPO OR
 GRAPHIC ERROR PLEASE RECTIFY.
  IS THE FLAT ROOF VENTED? CLARIFY SECTION
  IS THE AS BUILT SLAB SIT ON 6MM POLYETHYLENE SHEET?
 PLEASE CONFIRM CURRENT AS BUILT CONDITIONS AND ADD NOTE
 ACCORDINGLY
  
 FBC 107.2.1 PLEASE CLARIFY
  
 COVERED ENCLOSED FRONT PORCH UNDER AC, CABANA AREA
 UNDER AC
  PROVIDE MECHANICAL DRAWINGS
  SUPPORTING DOCUMENT: ENERGY CALCULATION MUST BE SIGNED
 BY OWNER.
  
 CLEARLY EXPRESS EXACT AS BUILT CONDITIONS ON ALL
 SHEETS.
 IF ADJUSTMENT ARE REQUIRED TO MEET 2020 RESIDENTIAL FBC
 PLEASE ITEMZED.
  
  
 END OF BUILDING COMMENTS
  
 IF YOU HAVE ANY QUESTIONS OR CONCERNS, PLEASE DO NOT
 HESITATE TO CONTACT ME
  
 LOUIS BOND, AIA
 BUILDING PLANS EXAMINER II
 DEVELOPMENT SERVICES DEPT.
 BUILDING DIVISION
 401 CLEMATIS STREET
 WEST PALM BEACH, FLORIDA 33401
 PH: 561-805-6729
 FX: 561-805-6676
 EMAIL: [email protected]
  
  
 NOTES:
 PLEASE PROVIDE COMMENT RESPONSE SHEET TO EXPLAIN HOW
 EACH COMMENT IS BEING ADDRESSED.
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2023-06-09 Cont ID  
Sent By jleahy Date 2023-06-09 Time 14:24 Rev Time 0.00
Received By jleahy Date 2023-06-09 Time 14:21 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2023-07-08 Cont ID  
Sent By avolcy Date 2023-07-08 Time 13:24 Rev Time 0.00
Received By avolcy Date 2023-05-31 Time 12:43 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2023-06-26 Cont ID  
Sent By lbond Date 2023-06-21 Time 16:44 Rev Time 0.00
Received By lbond Date 2023-06-21 Time 16:44 Sent To  
Notes
2023-06-21 16:45:52BUILDING REVIEW COMMENTS:
  
 W.P.B. PERMIT: 23031314
  
 REVIEWED: 6.21.2023
  
 FLORIDA BUILDING CODE,7TH EDITION (2020)
 FBC[AMENDED] = 2017 CHAPTER 1 WPB AMENDMENTS (SEE LINK
 BELOW)
 HTTPS://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/
 BUILDING-PERMIT-FORMS
 FBC BUILDING
 FBC EXISTING BUILDING
  
 COMMENTS:
  
 109 FBC[AMENDED] PLANS WILL BE REVIEWED BY THE PBC
 IMPACT FEE OFFICE DIGITALLY VIA PROJECTDOX UPON
 NOTIFICATION BY THIS OFFICE. NOTIFICATION MAY OCCUR
 WHEN PLANS ARE NEAREST FINAL FORM. YOU MAY COORDINATE
 WITH THE IMPACT FEE OFFICE AT (561) 233-5025 OR SIMPLY
 UPLOAD THE MUNICIPAL IMPACT FEE QUESTIONNAIRE FORM TO
 YOUR PROJECT AND NAME THE FILE MUNICIPAL IMPACT FEE
 QUESTIONNAIRE. THE FORM CAN BE FOUND AT: HTTP://DISCOVE
 R.PBCGOV.ORG/PZB/ADMINISTRATION/PDF/IMPACTFEES/FORMS/QU
 ESTIONNAIRE.PDF UPON APPROVAL AND FEE PAYMENT, PLEASE
 UPLOAD THE RECEIPT TO YOUR PROJECT OR EMAIL IT TO
 [email protected]
  
  
  
 IF YOU HAVE ANY QUESTIONS OR CONCERNS, PLEASE DO NOT
 HESITATE TO CONTACT ME
  
 LOUIS BOND, AIA
 BUILDING PLANS EXAMINER II
 DEVELOPMENT SERVICES DEPT.
 BUILDING DIVISION
 401 CLEMATIS STREET
 WEST PALM BEACH, FLORIDA 33401
 PH: 561-805-6729
 FX: 561-805-6676
 EMAIL: [email protected]
  
 NOTES:
 PLEASE PROVIDE COMMENT RESPONSE SHEET TO EXPLAIN HOW
 EACH COMMENT IS BEING ADDRESSED.
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2023-06-21 Cont ID  
Sent By cmontell Date 2023-06-21 Time 12:47 Rev Time 0.00
Received By cmontell Date 2023-06-21 Time 12:47 Sent To  
Notes
2023-06-21 12:47:46NEED MECHANICAL SCOPE AND PLAN
  
 CHRIS MONTELLO
 561-805-6733

Review Stop P PLUMBING
Rev No 1 Status F Date 2023-06-01 Cont ID  
Sent By rwbrown Date 2023-06-01 Time 06:50 Rev Time 0.00
Received By rwbrown Date 2023-06-01 Time 06:50 Sent To  
Notes
2023-06-01 06:52:181ST PLUMBING REVIEW
  
 THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED
 BY RYAN BROWN WITH THE FOLLOWING COMMENTS.
  
 1. 2020 FRC P3108.1 - THE KITCHEN CANNOT BE INCLUDED IN
 THE WET VENT. THE KITCHEN MUST DISCHARGE DOWNSTREAM OF
 THE LAST BATHROOM GROUP FIXTURE'S CONNECTION TO THE WET
 VENT. (CANNOT BE TIED INTO THE LAV'S FIXTURE DRAIN)
  
 2. 2020 FRC P3101.2.1 - THE SINK NEXT TO THE LAUNDRY
 MUST BE VENTED WITH ONE OF THE APPROVED METHODS.
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
  
 RYAN W. BROWN
 CHIEF PLUMBING INSPECTOR
 OFFICE: 561-805-6692
 CELL: 561-517-4293
 EMAIL: [email protected]
  
  
 V7 FPC - 2020 FLORIDA PLUMBING CODE
 V7 FGC - 2020 FLORIDA FUEL GAS
 V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE
 V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE
 V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE
 V7 FEC - 2020 FLORIDA ENERGY CONSERVATION
 2021 F.S. - 2021 FLORIDA STATUTES
 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE
 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE
 FBC CHAPTER 1
  
  

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2023-06-21 Cont ID  
Sent By lbond Date 2023-06-21 Time 17:01 Rev Time 0.00
Received By lbond Date 2023-06-21 Time 17:01 Sent To  
Notes
2023-06-21 17:01:52SEE BUILDING NOTES

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2023-06-05 Cont ID  
Sent By lbond Date 2023-06-05 Time 16:18 Rev Time 0.00
Received By lbond Date 2023-06-05 Time 16:18 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2023-07-08 Cont ID  
Sent By gvolcy Date 2023-07-08 Time 13:12 Rev Time 0.00
Received By avolcy Date 2023-07-08 Time 13:12 Sent To  
Notes
2023-07-08 13:16:2607.08.2023 -
  
 APPROVAL IS FOR STRUCTURAL ADDITION ONLY. DRIVEWAY AND
 PAVERS AND OTHER PROPOSED WORK SHALL BE UNDER SEPARATE
 PERMITS.
  
 PER LAND DEVLOPMENT REGULATIONS SECTION 94-482:
 LOCATION AND SURFACE. REQUIRED OFF-STREET PARKING
 SPACES FOR LESS THAN THREE RESIDENTIAL DWELLING UNITS
 SHALL BE PROVIDED ON THE PROPERTY ON WHICH THE UNITS
 ARE LOCATED. REQUIRED PARKING MAY BE LOCATED IN A FRONT
 YARD; HOWEVER, THE LESSER OF 1,000 SQUARE FEET OR 75
 PERCENT OF THE FRONT YARD AREA SHALL BE LANDSCAPED WITH
 LIVING PLANT MATERIAL (SUCH AS GRASS, GROUND COVER,
 SHRUBS, HEDGES, VINES OR TREES).
 UPDATE PLANS TO SHOW THAT THIS REQUIREMENT IS MET FOR
 PAVERS PERMIT.
  
 **REVIEWED BY:**
 GAISHA (ANNE-CLERISSE) VOLCY
 PLANNER
 [email protected]


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved