Plan Review Stops For Permit 23030553 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2023-06-01 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2023-06-01 |
Time |
12:50 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2023-06-01 |
Time |
12:50 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2023-05-04 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2023-05-04 |
Time |
08:26 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2023-05-04 |
Time |
08:21 |
Sent To |
|
|
Notes |
2023-05-04 08:26:36 | EV CHARGING STATION | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected] | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | AMENDMENT | | | | CORRECTIONS NEEDED - | | | | 1) THE SIGNED AND SEALED DRAWINGS DO NOT SHOW AS | | DIGITALLY SIGNED IN ADOBE READER - IF DELIVERING | | DRAWINGS TO THE CITY THEY CANNOT BE DIGITALLY SIGNED | | THEY WILL NEED TO BE PHYSICALLY SIGNED. | | | | I CHECK THE ELECTRONIC SIGNATURE BY OPENING THEM IN | | "ADOBE READER". THE "ADOBE READER" STATES WHETHER THEY | | ARE AN ORIGINAL ELECTRONICALLY SIGNED DOCUMENT. WHEN | | ELECTRONICALLY SIGNED DRAWINGS ARE PRINTED OUT, THEY | | LOSE THEIR ELECTRONIC SIGNATURE. ELECTRONICALLY SIGNED | | DRAWINGS NEED TO BE MOVED AROUND IN THE COMPUTER FROM | | PLACE TO PLACE. FROM THE ARCHITECT'S OR ENGINEER'S | | COMPUTER TO YOUR COMPUTER TO THE CITY'S ELECTRONIC PLAN | | REVIEW (PROJECTDOX). MAYBE YOURS WERE PRINTED OUT AT | | SOME TIME? |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2023-03-24 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2023-03-24 |
Time |
16:02 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2023-03-24 |
Time |
15:55 |
Sent To |
|
|
Notes |
2023-03-24 16:02:24 | EV CHARGING STATION | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected] | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | AMENDMENT | | | | CORRECTIONS NEEDED - | | | | 1) PLEASE PROVIDE THE CHARGING POST FOUNDATION AND | | ATTACHMENT TO FOUNDATION DETAILS TO MEET THE REQUIRED | | WIND DESIGN PRESSURES. FBC 1609 | | | | 2) THE LOCATION OF THE EV CHARGERS IS NOT CLEAR - ARE | | THEY FOR THE GENERAL PUBLIC OR THE SERVICE FACILITY | | ONLY. | | | | 3) EV CHARGERS FOR THE GENERAL PUBLIC - PLEASE SHOW | | THAT AT LEAST 1 OF THE CHARGING STATIONS IS AN | | ACCESSIBLE PARKING SPACE, ACCESS AISLE, SIGNAGE ETC. | | PER FBC 502 | | FBC 406.1.7 ELECTRIC VEHICLE CHARGING STATIONS. | | ACCESSIBILITY TO ELECTRIC VEHICLE CHARGING STATIONS | | SHALL BE PROVIDED IN ACCORDANCE WITH CHAPTER 11. | | | | 4) DRAWINGS PROVIDED NEED TO BE SIGNED AND SEALED BY | | THE DESIGNER. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2023-06-05 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2023-06-05 |
Time |
15:38 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2023-06-05 |
Time |
15:33 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2023-05-05 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2023-05-05 |
Time |
10:27 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2023-05-05 |
Time |
10:14 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2023-03-09 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2023-03-09 |
Time |
14:28 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2023-03-09 |
Time |
14:16 |
Sent To |
|
|
Notes |
2023-03-09 14:49:40 | FLORIDA BUILDING CODE 2020 7TH EDITION | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED | | NFPA 70 2017 EDITION | | | | JAKE LEAHY | | ELECTRICAL PLANS EXAMINER II | | 561-805-6713 | | [email protected] | | | | PLEASE INDICATE IF THIS IS A NEW SERVICE.. | | | | IF SO PLEASE INDICATE WHERE ALL OTHER MAINS ARE LOCATED | | IN BUILDING. | | | | WHERE A BUILDING OR STRUCTURE IS SUPPLIED BY MORE THAN | | ONE SERVICE, OR ANY COMBINATION OF BRANCH CIRCUITS, | | FEEDERS, AND SERVICES, A PERMANENT PLAQUE OR DIRECTORY | | SHALL BE INSTALLED AT EACH SERVICE DISCONNECT LOCATION | | DENOTING ALL OTHER SERVICES. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2023-06-06 |
|
|
Cont ID |
|
Sent By |
vbroglia |
Date |
2023-06-06 |
Time |
16:45 |
Rev Time |
0.00 |
Received By |
vbroglia |
Date |
2023-05-31 |
Time |
17:53 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2023-05-16 |
|
|
Cont ID |
|
Sent By |
vbroglia |
Date |
2023-05-16 |
Time |
14:17 |
Rev Time |
0.00 |
Received By |
vbroglia |
Date |
2023-05-02 |
Time |
10:18 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2023-03-24 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2023-03-24 |
Time |
16:05 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2023-03-08 |
Time |
07:05 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
3 |
Status |
P |
Date |
2023-06-01 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2023-06-01 |
Time |
12:51 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2023-06-01 |
Time |
12:51 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
F |
Date |
2023-05-02 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2023-05-02 |
Time |
12:32 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2023-05-02 |
Time |
12:32 |
Sent To |
|
|
Notes |
2023-05-02 12:35:19 | SIGNATURE REVIEW FBC- 2020 | | PERMIT- 23030553 | | 5/2/23 | | | | CODES IN EFFECT: | | FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) THE SUBMITTED PLAN SHEETS 01, 02, 03, 03A, 04, & 04A | | APPEAR TO BE PRINTED COPIES OF DIGITALLY SIGNED AND | | SEALED PLANS. PLANS PREPARED BY FL. LICENSED ENGINEERS | | THAT ARE TRANSMITTED ELECTRONICALLY SHALL BEAR | | VERIFIABLE DIGITAL SEALS AND SIGNATURES OF THE | | ENGINEERS- FL. STATUTE 471.025, AND SECTION | | 61G15-23.005 FAC. PLANS SUBMITTED IN PAPER FORM TO THE | | FRONT COUNTER OF THE WPB BUILDING DEPT. SHALL BEAR | | EITHER RAISED OR INK SEALS AND THE WET SIGNATURES OF | | THE ENGINEER OF RECORD. | | | | CHRISTOPHER L. COLE | | MECHANICAL/PLUMBING PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2023-03-08 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2023-03-08 |
Time |
15:28 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2023-03-08 |
Time |
15:28 |
Sent To |
|
|
Notes |
2023-03-08 15:32:56 | THE ENGINEER WHOSE NAME APPEARS IN THE TITLE BLOCK ON | | THE DRAWINGS DID NOT SIGN AND SEAL THE PAPER PLANS. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2023-06-06 |
|
|
Cont ID |
|
Sent By |
vbroglia |
Date |
2023-06-06 |
Time |
16:45 |
Rev Time |
0.00 |
Received By |
vbroglia |
Date |
2023-06-06 |
Time |
16:45 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2023-05-16 |
|
|
Cont ID |
|
Sent By |
vbroglia |
Date |
2023-05-16 |
Time |
14:16 |
Rev Time |
0.00 |
Received By |
vbroglia |
Date |
2023-05-16 |
Time |
14:16 |
Sent To |
|
|
Notes |
2023-05-16 14:17:35 | PREVIOUS COMMENTS NOT ADDRESSED, A PD MINOR AMENDMENT | | APPLICATION IS REQUIRED PRIOR TO BUILDING PERMIT | | APPROVAL | | | | SEE PREVIOUS COMMENTS. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2023-03-14 |
|
|
Cont ID |
|
Sent By |
vbroglia |
Date |
2023-03-14 |
Time |
11:51 |
Rev Time |
0.00 |
Received By |
vbroglia |
Date |
2023-03-14 |
Time |
11:51 |
Sent To |
|
|
Notes |
2023-03-14 11:58:49 | 3/14/2023 FAILED | | | | PLEASE APPLY FOR A PD MINOR AMENDMENT APPLICATION | | EMAIL [email protected] FOR APPLICATION | | | | PLEASE ELECTRIC VECHIECAL CHARING PARKING SPOTS CANNOT | | COUNT TOWARDS REQUIRED PARKING | | | | **** REVIEWD BY **** | | VALENTINA BROGLIA | | PLANNER | | [email protected] | | |
|
|