Plan Review Details - Permit 23030546
Plan Review Stops For Permit 23030546
Review Stop AD ADDRESSING
Rev No 1 Status F Date 2023-04-18 Cont ID  
Sent By cpuell Date 2023-04-18 Time 13:00 Rev Time 0.00
Received By cpuell Date 2023-04-18 Time 13:00 Sent To  
Notes
2023-04-18 13:03:13IS THE SCOPE OF WORK FOR THE NORTH AND OR SOUTH
 BUILDING? PLEASE RESPOND TO [email protected] OR
 CALL 561-805-6659

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2023-04-14 Cont ID  
Sent By jbrooks Date 2023-04-14 Time 09:39 Rev Time 0.00
Received By jbrooks Date 2023-04-14 Time 07:46 Sent To  
Notes
2023-04-14 09:39:30JONATHAN BROOKS JR.
 BUILDING PLANS EXAMINER
 WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM
 PHONE (561) 805-6656
 EMAIL: [email protected]
  
 1ST REVIEW: FBC 2020 7TH EDITION
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
 TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT
 CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX.
  
 1. FBC R 908.2 PROVIDE CERTIFICATION THAT THE EXISTING
 STRUCTURAL ROOF COMPONENTS CAN SUPPORT THE NEW CONCRETE
 ROOFING TILE SYSTEM TO BE USED.
 2. FBC R 301 FAC9N-3 SUBMITTED MIAMI-DADE COUNTY NOA
 21-0614.05 COVERS MULTIPLE ATTACHMENT SYSTEMS;
 MECHANICAL, ADHESIVE AND MORTAR SET. SELECT SYSTEM TO
 BE USED. ALL APPLICABLE DETAILS AND ATTACHMENTS MUST BE
 CLEARLY IDENTIFIED ON THE PRODUCT APPROVAL DRAWINGS.
 DETAILS AND ATTACHMENTS NOT SPECIFICALLY COVERED IN
 PRODUCT APPROVALS WILL NEED SITE-SPECIFIC ENGINEERING.
 3. FBC R 301 FAC9N-3. PROVIDE A COMPLETE SET OF 2020
 CODE VERSION PRODUCT APPROVALS/NOA'S FOR THE PROPOSED
 HIP & RIDGE METAL TO BE USED. (FL5374-R6)
 4. FBC R 301 FAC9N-3. PROVIDE A COMPLETE SET OF 2020
 CODE VERSION PRODUCT APPROVALS/NOA'S FOR THE PROPOSED
 HIP & RIDGE TILE ADHESIVE TO BE USED.
 5. FBC B 107.2.1 FOR CLARITY PLEASE REVISE ROOF
 DIAGRAM/SKETCH TO INDICATE THE AREAS TO RECEIVE NEW
 ROOFING CLEARLY IDENTIFIED ON DRAWING AND INCLUDE ROOF
 SLOPE(S), MEAN ROOF HEIGHT(S). FLAT/LOW SLOPE ROOFS
 MUST SHOW POSITIVE DRAINAGE.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2023-04-28 Cont ID  
Sent By amhamilt Date 2023-04-28 Time 12:06 Rev Time 0.00
Received By amhamilt Date 2023-04-28 Time 12:06 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2023-05-01 Cont ID  
Sent By aoliver Date 2023-05-01 Time 07:24 Rev Time 0.00
Received By aoliver Date 2023-04-13 Time 13:25 Sent To  
Notes
***NONE***