2023-03-06 13:51:09 | JONATHAN BROOKS JR. |
| BUILDING PLANS EXAMINER |
| WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM |
| PHONE (561) 805-6656 |
| EMAIL: [email protected] |
| |
| 1ST REVIEW: FBC 2020 7TH EDITION |
| FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) |
| FBC B = FBC BUILDING |
| FBC R = FBC RESIDENTIAL |
| FBC EB = FBC EXISTING BUILDING |
| FBC A = FBC ACCESSIBILITY |
| FBC EC = FBC ENERGY CONSERVATION |
| WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC |
| RESULTS: DENIED |
| ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT |
| TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT |
| CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX. |
| |
| 1. FBC B 107.2.1 SUBMITTED PRODUCT APPROVAL FL5259-R37 |
| (HVHZ) IS NOT APPROVED FOR USE OUTSIDE HVHZ. CITY OF |
| WEST PALM BEACH IS NOT LOCATED IN A HVHZ. YOU MIGHT |
| CONSIDER USING FL5259-R37 (NON-HVHZ). |
| 2. FBC B 107.2.1 SUBMITTED PRODUCT APPROVAL FL5259-R37 |
| (NON- HVHZ) COVERS MULTIPLE PRODUCT TYPES; ROOF COVER |
| OPTIONS; ALLOWABLE UNDERLAYMENT/TILE-ADHESIVE |
| COMBINATIONS, ALLOWABLE SUBSTRATES, ATTACHMENT |
| LIMITATIONS & INSTALLATION APPROVED ASSEMBLIES. SELECT |
| ATTACHMENT LIMITATION SYSTEM USED FROM 5.8.3.1 |
| DIRECT-TO-DECK TABLE 4A: ALLOWABLE DESIGN PRESSURES, |
| DIRECT-TO-DECK UNDERLAYMENT IN TILE ROOF APPLICATIONS |
| PAGE #6 & 7 OR ATTACHMENT LIMITATION SYSTEM FROM |
| 5.8.3.2 MECHANICALLY-ATTACHED BASE SHEET TABLE 4B |
| ALLOWABLE DESIGN PRESSURES, 2-PLY UNDERLAYMENT SYSTEMS |
| IN TILE ROOF APPLICATIONS PAGES #8-14. |
| |
| PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
| |