Plan Review Stops For Permit 23021437 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2023-03-13 |
|
|
Cont ID |
|
Sent By |
lbond |
Date |
2023-03-13 |
Time |
15:41 |
Rev Time |
0.00 |
Received By |
lbond |
Date |
2023-03-13 |
Time |
15:41 |
Sent To |
|
|
Notes |
2023-03-13 15:42:12 | PROVISO DIGITALLY SIGNED STRUCTURAL DRAWINGS |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2023-03-23 |
|
|
Cont ID |
|
Sent By |
jcooley |
Date |
2023-03-23 |
Time |
18:33 |
Rev Time |
0.00 |
Received By |
jcooley |
Date |
2023-03-21 |
Time |
17:02 |
Sent To |
|
|
Notes |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
F |
Date |
2023-03-13 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2023-03-13 |
Time |
17:30 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2023-03-13 |
Time |
17:03 |
Sent To |
|
|
Notes |
2023-03-13 17:31:12 | 1ST REVIEW FBC-2020 RES. GAS | | PERMIT- 23021437 | | 3/13/23 | | | | CODES IN EFFECT: | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION | | 2020 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) SHEET P2: PLEASE PROVIDE A COMPLETE GAS RISER | | DRAWING FOR THE PROJECT THAT SHOWS THE CONTINUOUS | | PIPING RUN FROM THE METER TO THE MOST REMOTE OUTLET. | | PLEASE INCLUDE ALL EXITING GAS PIPING AND EXISTING GAS | | APPLIANCES ALONG WITH THE NEW INSTALLATIONS- SEC. | | G2412.3, G2412.4, & G2413.4.1 FBC RES. THE CURRENT | | RISER AND PLAN IS CONFUSING BECAUSE IT APPEARS TO SHOW | | TWO DIFFERENT SYSTEMS- ONE FOR THE WATER HEATER AND ONE | | FOR THE RANGE. | | | | A) P2: THE GAS NOTES INDICATE A TOTAL LOAD OF 199,000 | | WHICH IS ONLY THE WATER HEATER. PLEASE INCLUDE THE | | LOADS OF ALL EXISTING GAS APPLIANCES AT THE RESIDENCE- | | SEE COMMENT #1 ABOVE. | | | | 2) P2: PLEASE SHOW THE CLEARANCE DISTANCE FROM THE | | TANKLESS WATER HEATER EXHAUST TO THE WINDOW IN THE | | HALLWAY. PLEASE NOTE A MINIMUM 4 FT. CLEARANCE IS | | REQUIRED TO OPERABLE OPENINGS- SECS. G2427.8 & G2448.1 | | FBC RES. | | | | 3) PROVIDE COMBUSTION AIR CALCULATIONS FOR THE RANGE- | | SEC. G2407.1 FBC RES. PLEASE NOT IF USING THE STANDARD | | METHOD OF INDOOR AIR VOLUME, A MINIMUM OF 6000 CU. FT. | | IS REQUIRED. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. | | | | CHRISTOPHER L. COLE | | MECHANICAL/PLUMBING PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
P |
Date |
2023-04-12 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2023-04-12 |
Time |
14:25 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2023-04-12 |
Time |
14:25 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2023-04-13 |
|
|
Cont ID |
|
Sent By |
lbond |
Date |
2023-04-13 |
Time |
08:53 |
Rev Time |
0.00 |
Received By |
lbond |
Date |
2023-03-10 |
Time |
08:18 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2023-04-13 |
|
|
Cont ID |
|
Sent By |
lbond |
Date |
2023-04-13 |
Time |
08:53 |
Rev Time |
0.00 |
Received By |
lbond |
Date |
2023-04-13 |
Time |
08:52 |
Sent To |
|
|
Notes |
2023-04-13 08:53:27 | 109 FBC[AMENDED] PLANS WILL BE REVIEWED BY THE PBC | | IMPACT FEE OFFICE DIGITALLY VIA PROJECTDOX UPON | | NOTIFICATION BY THIS OFFICE. NOTIFICATION MAY OCCUR | | WHEN PLANS ARE NEAREST FINAL FORM. YOU MAY COORDINATE | | WITH THE IMPACT FEE OFFICE AT (561) 233-5025 OR SIMPLY | | UPLOAD THE MUNICIPAL IMPACT FEE QUESTIONNAIRE FORM TO | | YOUR PROJECT AND NAME THE FILE MUNICIPAL IMPACT FEE | | QUESTIONNAIRE. THE FORM CAN BE FOUND AT: HTTP://DISCOVE | | R.PBCGOV.ORG/PZB/ADMINISTRATION/PDF/IMPACTFEES/FORMS/QU | | ESTIONNAIRE.PDF UPON APPROVAL AND FEE PAYMENT, PLEASE | | UPLOAD THE RECEIPT TO YOUR PROJECT OR EMAIL IT TO | | [email protected] | | | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2023-03-14 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2023-03-14 |
Time |
10:49 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2023-03-14 |
Time |
10:49 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2023-03-13 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2023-03-13 |
Time |
17:02 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2023-03-13 |
Time |
16:41 |
Sent To |
|
|
Notes |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
P |
Date |
2023-03-13 |
|
|
Cont ID |
|
Sent By |
lbond |
Date |
2023-03-13 |
Time |
15:37 |
Rev Time |
0.00 |
Received By |
lbond |
Date |
2023-03-13 |
Time |
15:37 |
Sent To |
|
|
Notes |
2023-03-13 15:40:29 | PROVISO DIGITALLY SIGNED STRUCTURAL DWGS |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2023-03-13 |
|
|
Cont ID |
|
Sent By |
lbond |
Date |
2023-03-13 |
Time |
13:47 |
Rev Time |
0.00 |
Received By |
lbond |
Date |
2023-03-13 |
Time |
13:47 |
Sent To |
|
|
Notes |
2023-03-13 13:47:49 | STRUCTURAL PLANS NOT DIGTALLY SIGNED AND SEALED-OTHERS | | OK |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2023-04-12 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2023-04-12 |
Time |
14:25 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2023-04-12 |
Time |
14:25 |
Sent To |
|
|
Notes |
2023-04-12 14:26:13 | REQUIRES SUBMITTAL OF SEPERATE LANDSCAPE PERMIT |
|
|