Plan Review Stops For Permit 23021384 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2023-06-06 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2023-06-06 |
Time |
09:31 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2023-06-06 |
Time |
07:56 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2023-05-31 |
|
|
Cont ID |
|
Sent By |
fgiaquin |
Date |
2023-05-31 |
Time |
21:44 |
Rev Time |
0.00 |
Received By |
fgiaquin |
Date |
2023-05-31 |
Time |
20:50 |
Sent To |
|
|
Notes |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
3 |
Status |
P |
Date |
2023-05-25 |
|
|
Cont ID |
|
Sent By |
rwbrown |
Date |
2023-05-25 |
Time |
07:08 |
Rev Time |
0.00 |
Received By |
rwbrown |
Date |
2023-05-25 |
Time |
07:08 |
Sent To |
|
|
Notes |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
2 |
Status |
P |
Date |
2023-03-13 |
|
|
Cont ID |
|
Sent By |
rwbrown |
Date |
2023-03-13 |
Time |
13:06 |
Rev Time |
0.00 |
Received By |
rwbrown |
Date |
2023-03-13 |
Time |
13:06 |
Sent To |
|
|
Notes |
2023-03-13 13:07:03 | GAS SUB REQUIRED WITH REVISION | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
F |
Date |
2023-03-01 |
|
|
Cont ID |
|
Sent By |
rwbrown |
Date |
2023-03-01 |
Time |
07:27 |
Rev Time |
0.00 |
Received By |
rwbrown |
Date |
2023-03-01 |
Time |
07:27 |
Sent To |
|
|
Notes |
2023-03-01 07:37:59 | GAS WAS NOT PART OF THE ORIGINAL PLANS. A GAS SUB IS | | REQUIRED. | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2023-06-06 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2023-06-06 |
Time |
09:31 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2023-05-24 |
Time |
17:54 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2023-03-13 |
|
|
Cont ID |
|
Sent By |
rwbrown |
Date |
2023-03-13 |
Time |
13:09 |
Rev Time |
0.00 |
Received By |
rwbrown |
Date |
2023-03-10 |
Time |
13:40 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2023-03-01 |
|
|
Cont ID |
|
Sent By |
rwbrown |
Date |
2023-03-01 |
Time |
07:39 |
Rev Time |
0.00 |
Received By |
rwbrown |
Date |
2023-02-27 |
Time |
13:20 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2023-05-25 |
|
|
Cont ID |
|
Sent By |
rwbrown |
Date |
2023-05-25 |
Time |
07:08 |
Rev Time |
0.00 |
Received By |
rwbrown |
Date |
2023-05-25 |
Time |
07:07 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2023-03-13 |
|
|
Cont ID |
|
Sent By |
rwbrown |
Date |
2023-03-13 |
Time |
13:05 |
Rev Time |
0.00 |
Received By |
rwbrown |
Date |
2023-03-13 |
Time |
13:05 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2023-03-01 |
|
|
Cont ID |
|
Sent By |
rwbrown |
Date |
2023-03-01 |
Time |
07:17 |
Rev Time |
0.00 |
Received By |
rwbrown |
Date |
2023-03-01 |
Time |
07:17 |
Sent To |
|
|
Notes |
2023-03-01 07:23:50 | 1ST PLUMBING REVIEW | | | | THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED | | BY RYAN BROWN WITH THE FOLLOWING COMMENTS. | | | | 1. 2020 FRC P3108.1 - THE BATHTUB IS NOT VENTED TO | | CODE. THE FIXTURE DRAIN IS CONNECTED TO A HORIZONTAL | | DRAIN THAT HAS A AUTOMATIC CLOTHES WASHER RUNNING | | THROUGH IT. THIS IS NOT A LEGAL WET VENT. ONLY BATHROOM | | GROUP FIXTURES ARE ALLOWED TO BE INCLUDED IN A WET VENT | | SYSTEM. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM. | | | | | | RYAN W. BROWN | | CHIEF PLUMBING INSPECTOR | | OFFICE: 561-805-6692 | | CELL: 561-517-4293 | | EMAIL: [email protected] | | | | | | V7 FPC - 2020 FLORIDA PLUMBING CODE | | V7 FGC - 2020 FLORIDA FUEL GAS | | V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE | | V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE | | V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE | | V7 FEC - 2020 FLORIDA ENERGY CONSERVATION | | 2021 F.S. - 2021 FLORIDA STATUTES | | 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE | | 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE | | FBC CHAPTER 1 | | | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
3 |
Status |
P |
Date |
2023-05-25 |
|
|
Cont ID |
|
Sent By |
rwbrown |
Date |
2023-05-25 |
Time |
07:07 |
Rev Time |
0.00 |
Received By |
rwbrown |
Date |
2023-05-25 |
Time |
07:07 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
F |
Date |
2023-03-13 |
|
|
Cont ID |
|
Sent By |
rwbrown |
Date |
2023-03-13 |
Time |
13:08 |
Rev Time |
0.00 |
Received By |
rwbrown |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2023-03-13 13:09:30 | SIGNATURE REVIEW FAILED - THE FILES SUBMITTED ARE NOT | | ELECTRONICALLY SEALED | | | | * ARCHITECTS- ALL ELECTRONIC SUBMISSIONS PREPARED BY AN | | ARCHITECT MUST COMPLY WITH 61G1-16.004 F.A.C. AND BE | | DIGITALLY SIGNED AND SEALED IN ACCORDANCE WITH | | 61G1-16.005 F.A.C. | | | | | | RYAN W. BROWN | | CHIEF PLUMBING INSPECTOR | | OFFICE: 561-805-6692 | | CELL: 561-517-4293 | | EMAIL: [email protected] | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
P |
Date |
2023-03-01 |
|
|
Cont ID |
|
Sent By |
rwbrown |
Date |
2023-03-01 |
Time |
07:39 |
Rev Time |
|
Received By |
rwbrown |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|