Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2023-06-26 Cont ID  
Sent By jbrooks Date 2023-06-26 Time 12:29 Rev Time 0.00
Received By jbrooks Date 2023-06-26 Time 08:03 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2023-05-08 Cont ID  
Sent By jbrooks Date 2023-05-08 Time 09:43 Rev Time 0.00
Received By jbrooks Date 2023-05-08 Time 07:53 Sent To  
Notes
2023-05-08 09:43:51JONATHAN BROOKS JR.
 BUILDING PLANS EXAMINER
 WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM
 PHONE (561) 805-6656
 EMAIL: [email protected]
  
 1ST REVIEW: FBC 2020 7TH EDITION
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
 TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT
 CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX.
  
 1. FBC B 107.2.1 PROVIDE A ROOF DRAINAGE PLAN THAT
 COMPLIES WITH SECTION 903.4 OF THE 2020 FBC-RESIDENTIAL
 AND CHAPTER 11 OF THE 2020 FBC-PLUMBING. SECOND
 REQUEST.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2023-03-01 Cont ID  
Sent By jbrooks Date 2023-03-01 Time 08:34 Rev Time 0.00
Received By jbrooks Date 2023-03-01 Time 07:33 Sent To  
Notes
2023-03-01 08:34:45JONATHAN BROOKS JR.
 BUILDING PLANS EXAMINER
 WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM
 PHONE (561) 805-6656
 EMAIL: [email protected]
  
 1ST REVIEW: FBC 2020 7TH EDITION
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
 TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT
 CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX.
  
 1. FBC R 301 FAC9N-3 SUBMITTED FLORIDA DBPR PRODUCT
 APPROVAL FL2533-R28 SYSTEM NO. W-79 DO NOT MEET THE
 MINIMUM ZONE 3 DESIGN PRESSURE REQUIREMENT OF -131.42
 FOR EXPOSURE CATEGORY D AREAS. PROVIDE SYSTEM THAT
 MEETS OR EXCEEDS ALL DESIGN PRESSURE REQUIREMENTS FOR
 EXPOSURE CATEGORY D/PROVIDE SIGNED AND SEALED
 ENGINEERED NAILING CALCULATIONS WITH AN APPROVED
 SYSTEM.
 2. FBC R 301 FAC9N-3. PROVIDE A COMPLETE SET OF 2020
 CODE VERSION PRODUCT APPROVALS/NOA'S FOR THE PROPOSED
 HIP & RIDGE METAL TO BE USED. (FL5374-R6)
 3. FBC R 301 FAC9N-3. PROVIDE A COMPLETE SET OF 2020
 CODE VERSION PRODUCT APPROVALS/NOA'S FOR THE PROPOSED
 HIP & RIDGE TILE ADHESIVE TO BE USED.
 4. FBC B 107.2.1 PROVIDE A ROOF DRAINAGE PLAN THAT
 COMPLIES WITH SECTION 903.4 OF THE 2020 FBC-RESIDENTIAL
 AND CHAPTER 11 OF THE 2020 FBC-PLUMBING
 5. FBC EB 706.8.1 PROVIDE A DETAILED COST ESTIMATE OF
 THE EVALUATION AND INSTALLATION OF CONNECTIONS AT THE
 GABLE ENDS OR ALL CORNERS THAT WILL EXCEED 15% OF THE
 COST OF THE ROOF REPLACEMENT WHEN COMPLETED.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  

Review Stop HIST HISTORICAL
Rev No 3 Status F Date 2023-07-10 Cont ID  
Sent By vbroglia Date 2023-07-10 Time 14:40 Rev Time 0.00
Received By vbroglia Date 2023-07-10 Time 14:40 Sent To  
Notes
2023-07-10 14:40:46SEE PREVIOUS COMMENTS, MUST RESUBMIT WITH CORRECTION
 MADE
  
  
 VALENTINA BROGLIA
 [email protected]
  

Review Stop HIST HISTORICAL
Rev No 2 Status F Date 2023-05-31 Cont ID  
Sent By amhamilt Date 2023-05-31 Time 10:25 Rev Time 0.00
Received By amhamilt Date 2023-05-31 Time 10:25 Sent To  
Notes
2023-05-31 10:26:02THE PERMIT HAS FAILED FOR THE FOLLOWING REASON(S)
  
 PREVIOUS COMMENTS NOT ADDRESSED SEE PREVIOUS COMMENTS
  
 ANNE HAMILTON
 HISTORIC PRESERVATION PLANNER
 [email protected]
 561.822.1428
  

Review Stop HIST HISTORICAL
Rev No 1 Status F Date 2023-03-24 Cont ID  
Sent By amhamilt Date 2023-03-24 Time 11:47 Rev Time 0.00
Received By amhamilt Date 2023-03-24 Time 11:47 Sent To  
Notes
2023-03-24 11:53:39THE PERMIT HAS FAILED FOR THE FOLLOWING REASON(S)
  
 PROPERTY IS IN A HISTORIC DISTRICT, S TILE IS NOT AN
 ARCHITECTURALLY APPROPRIATE CHOICE. PLEASE REVISE TO A
 TRUE BARREL TILE.
  
 ANNE HAMILTON
 HISTORIC PRESERVATION PLANNER
 [email protected]
 561.822.1428
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2023-07-10 Cont ID  
Sent By vbroglia Date 2023-07-10 Time 14:41 Rev Time 0.00
Received By vbroglia Date 2023-06-14 Time 09:12 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2023-06-01 Cont ID  
Sent By aoliver Date 2023-06-01 Time 08:18 Rev Time 0.00
Received By aoliver Date 2023-05-02 Time 08:48 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2023-03-27 Cont ID  
Sent By lmarchan Date 2023-03-27 Time 07:54 Rev Time 0.00
Received By lmarchan Date 2023-02-28 Time 10:39 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2023-05-08 Cont ID  
Sent By jbrooks Date 2023-05-08 Time 09:44 Rev Time 0.00
Received By jbrooks Date 2023-05-08 Time 09:44 Sent To  
Notes
***NONE***