Plan Review Details - Permit 23020716
Plan Review Stops For Permit 23020716
Review Stop AD ADDRESSING
Rev No 1 Status P Date 2023-02-23 Cont ID  
Sent By cpuell Date 2023-02-23 Time 16:45 Rev Time 0.00
Received By cpuell Date 2023-02-23 Time 16:45 Sent To  
Notes
2023-02-23 16:46:43ADDRESS APPROPRIATE FOR PROJECT.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2023-07-10 Cont ID  
Sent By jgomez Date 2023-07-10 Time 10:37 Rev Time 0.00
Received By jgomez Date 2023-07-10 Time 10:08 Sent To  
Notes
2023-07-06 17:11:37RESIDENTIAL(R3) SECOND BUILDING REVIEW COMMENTS
 CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS.
 PERMIT #23020716
 2735 EMBASSY DR.
  
 PROVISO NOTE:
 BUILDING REVIEW MAY BE APPROVED WITH PROVISO. PROVISO
 MEANS CONTRACTOR WILL SUBMIT REQUIRED INFORMATION AFTER
 THE PERMIT IS ISSUED BUT BEFORE INSPECTIONS TO AVOID
 CONFLICTS/DELAYS. REVISION FEES APPLY (EXCEPT FOR
 PRODUCT APPROVALS/ DEFERRED SUBMITTAL).
  
 ***IMPORTANT***
 BUILDING REVIEW WILL BE APPROVED WITH PROVISO ONCE THE
 ENERGY CALCULATIONS ARE CERTIFIED AT THE BOTTOM OF FORM
 BY THE OWNER OR AUTHORIZED AGENT AND THE ENGINEER
 ADDRESSES THE DIGITAL SIGNATURE REVIEW COMMENTS.
  
 ***IMPORTANT
 ****CONTRACTOR TO ADVICE IF PROVISO OPTION IS PREFERRED
 AT THIS TIME OR IF RE-SUBMITTING REQUIRED INFORMATION
 BEFORE PERMIT ISSUANCE.
  
  
 1- LOT DRAINAGE. PROPOSED WORK AFFECTS THE LOT
 DRAINAGE. PROVIDE DRAINAGE PLAN SHOWING HOW THE SURFACE
 DRAINAGE IS KEPT WITHIN THE LOT AND NOT DIVERTED TO
 ADJACENT PROPERTIES. PROVIDE DRAINAGE PLAN SHOWING
 COMPLIANCE WITH THE FOLLOWING SECTIONS: R401.3
 FBC-RESIDENTIAL. SEC. 107.2.5 CITY AMENDMENTS AND SEC.
 110.9 CITY AMENDMENTS.
 NOTE: DRAINAGE PLAN TO SHOW THE EXISTING AND PROPOSED
 GRADE ELEVATIONS SHOWING HOW KEEPING WATER AWAY FROM
 ADJACENT PROPERTIES.
  
 RESPONSE:
 1- SITE DRAINAGE PLANS HAVE AN ENGINEER'S
 SELF-CERTIFIED DIGITAL SIGNATURE. ENGINEER CANNOT
 SELF-CERTIFY THE DIGITAL SIGNATURE. THIRD PARTY
 CERTIFICATION IS REQUIRED BY FAC 61G15-23.004. (NOTE:
 ENGINEER TO CONTACT THE BOARD OF ENGINEER'S FOR
 SELF-CERTIFIED DIGITAL SIGNATURE QUESTIONS).
  
 4- PROVIDE COMPLETE DETAILS AND SPECIFICATIONS FOR
 STAIRWAY CONSTRUCTION: DIMENSIONS, RISERS, TREADS,
 NOSING, HANDRAILS, GUARDRAILS, ETC. SHOWING COMPLIANCE
 WITH SEC. R311.7 FBC-RESIDENTIAL.
  
 RESPONSE:
 EVEN THOUGH THIS WILL BE DEFERRED SUBMITTAL, THE
 DESIGNER OF RECORD STILL NEEDS TO SPECIFY THE DESIGN
 GUIDELINES REQUIRED BY TABLE R301.5, SEC. R311.7. AND
 SEC. R312.1 FBC-RESIDENTIAL. NOTE: JUST CITING THE CODE
 SECTION IS NOT ALLOWED (SEC. 107.2.1 CITY AMENDMENTS).
 CLEARLY SPECIFY ON PLANS THE DESIGN GUIDELINES AND
 STATE ON DRAWINGS THAT SHOP DRAWINGS NEED TO BE
 SUBMITTED FOR DESIGNER OF RECORD REVIEW. ALL SHOP
 DRAWINGS TO BE REVIEWED BY THE DESIGN PROFESSIONAL OF
 RECORD PRIOR TO SUBMITTAL TO THIS OFFICE.
 NOTE: OPEN RISERS NEED TO MEET THE REQUIREMENTS OF SEC.
 R311.7.5.1 FBC-RESIDENTIAL.
  
 5- LIVING AREA SLIDING GLASS DOORS. BASED ON PLANS AND
 DOOR SCHEDULE, IT LOOKS LIKE THERE ARE TWO SLIDING
 GLASS DOORS MULLED TOGETHER. SPECIFY MULLION SIZE AND
 CONNECTIONS AND PROVIDE PRODUCT APPROVAL.. SEC. R301.1
 FBC-RESIDENTIAL.
  
 RESPONSE:
 EVEN THOUGH THIS WILL BE DEFERRED SUBMITTAL, THE
 DESIGNER OF RECORD STILL NEEDS TO SPECIFY THE MULLION
 TYPE, SIZE AND CONNECTORS.
 SEC. R301.1 FBC-RESIDENTIAL.
  
 8- BALCONY GUARDRAIL: IT IS NOT CLEAR WHAT TYPE OF
 RAILING IS GOING TO BE INSTALLED. SECOND FLOOR PLANS
 SPECIFIES 36" HIGH RAILING W/ PICKETS TO REJECT A 4"
 DIAM. SPHERE, WHILE REAR ELEVATION SHOWS GUARDRAIL THAT
 LOOKS LIKE A CABLE SYSTEM. REVISE AS REQUIRED TO MATCH
 AND PROVIDE THE DETAILS AND SPECIFICATIONS FOR THE
 CONSTRUCTION OF THE GUARDRAIL SHOWING COMPLIANCE WITH
 TABLE R301.5, SEC. R311.7.8 AND SEC. R312.1
 FBC-RESIDENTIAL.
 NOTE: SUBSEQUENT SHOP DRAWINGS ARE TO CONFIRM THAT
 DESIGN DETAILS AND SPECIFICATIONS ARE MET.
  
 RESPONSE:
 EVEN THOUGH THIS WILL BE DEFERRED SUBMITTAL, THE
 DESIGNER OF RECORD STILL NEEDS TO SPECIFY THE DESIGN
 GUIDELINES REQUIRED BY TABLE R301.5, SEC. R311.7. AND
 SEC. R312.1 FBC-RESIDENTIAL.
  
 11-PROVIDE DETAILS AND SPECIFICATIONS FOR DECORATIVE
 SHUTTERS CONSTRUCTION AND INSTALLATION. SPECIFY
 FASTENING. SEC. R301.2.1 FBC-RESIDENTIAL.
  
 RESPONSE:
 WILL BE A DEFERRED SUBMITTAL.
  
 18- PRODUCT APPROVALS DEFERRED SUBMITTAL AFTER PERMIT
 IS ISSUED(APPROVED BY ENGINEER OF RECORD):
 A)ALL EXTERIOR DOORS.
 B)ALL WINDOWS.
 C)WINDOW MULLIONS (NOTE: NEED TO SPECIFY MULLION SIZE).
 D)HURRICANE SHUTTERS IF DOORS AND WINDOWS DON'T HAVE
 IMPACT GLAZING.
 E)METAL ROOF (IF USED).
 F)ROOF TILE AND CLEARLY MARK ADHESIVE PADDY SIZE TO BE
 USED.
 G)ROOFING UNDERLAYMENT SPECIFIED ON PLANS.
 H)ROOF TILE ADHESIVE(IF USED)LISTED IN ROOF TILE
 PRODUCT APPROVAL.
 I)HIP & RIDGE METAL SUPPORT TO BE USED.
 J)BALCONY UNDERLAYMENT SPECIFIED ON PLANS TO RECEIVE
 TILE.
 K) FLAT ROOF. AND, CLEARLY MARK ASSEMBLY TO BE
 INSTALLED.
  
 20- ENERGY CALCULATIONS:
 A)THE BUILDING'S OWNER, THE OWNER'S ARCHITECT, OR OTHER
 AUTHORIZED AGENT LEGALLY DESIGNATED BY THE OWNER SHALL
 CERTIFY AT THE OWNER/AGENT LINE AT THE BOTTOM OF FORM
 THAT THE BUILDING IS IN COMPLIANCE WITH THE CODE, AS
 PER SECTION 553.907, FLORIDA STATUTES, PRIOR TO
 RECEIVING THE PERMIT TO BEGIN CONSTRUCTION OR
 RENOVATION AS REQUIRED BY SECTION R103.1.1.2 FBC-ENERGY
 CONSERVATION.
  
 RESPONSE:
 NOT ADDRESSED.
  
 B)PROVIDE COMPLETE INFORMATION ON TOP OF FORM,
 INCLUDING OWNER NAME, BUILDER NAME (IF AVAILABLE),
 CORRECT PERMIT OFFICE (CITY OF WEST PALM BEACH NOT PALM
 BEACH COUNTY), JURISDICTION NUMBER (THIS JURISDICTION
 IS 604700). SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION.
  
 RESPONSE:
 OWNER'S NAME IS INCORRECT, BUILDER'S NAME IS INCORRECT.
 REVISE AS REQUIRED.
 SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION.
  
 C)PROVIDE THE NAME OF THE PERSON DOING THE CALCULATIONS
 AS REQUIRED BY SEC. R405.4.2.1 FBC-ENERGY CONSERVATION.
  
 RESPONSE:
 NOT ADDRESSED. PROVIDE NAME , NOT SIGNATURE.
  
 G)BUILDER TO COMPLETE THE ENERGY PERFORMANCE LEVEL
 (EPL) DISPLAY CARD. SEC. R405.4.3 FBC-ENERGY
 CONSERVATION.
  
 RESPONSE:
 NOT ADDRESSED.
  
 WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE
 ORIGINAL REVIEW COMMENT WITH A DESCRIPTION OF WHERE AND
 HOW THE COMMENT WAS ADDRESSED WILL HELP TO EXPEDITE THE
 REVIEW PROCESS. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2023-03-14 Cont ID  
Sent By jgomez Date 2023-03-14 Time 13:21 Rev Time 0.00
Received By jgomez Date 2023-03-14 Time 09:19 Sent To  
Notes
2023-03-14 13:21:52RESIDENTIAL (R3) BUILDING REVIEW COMMENTS
 CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS.
 PERMIT #23020716
 2735 EMBASSY DR
  
 1- LOT DRAINAGE. PROPOSED WORK AFFECTS THE LOT
 DRAINAGE. PROVIDE DRAINAGE PLAN SHOWING HOW THE SURFACE
 DRAINAGE IS KEPT WITHIN THE LOT AND NOT DIVERTED TO
 ADJACENT PROPERTIES. PROVIDE DRAINAGE PLAN SHOWING
 COMPLIANCE WITH THE FOLLOWING SECTIONS: R401.3
 FBC-RESIDENTIAL. SEC. 107.2.5 CITY AMENDMENTS AND SEC.
 110.9 CITY AMENDMENTS.
 NOTE: DRAINAGE PLAN TO SHOW THE EXISTING AND PROPOSED
 GRADE ELEVATIONS SHOWING HOW KEEPING WATER AWAY FROM
 ADJACENT PROPERTIES.
  
 2- ACCORDING TO SEC. R301.2.1.4 FBC-RESIDENTIAL THIS
 BUILDING IS LOCATED IN EXPOSURE "D" NOT "C". EACH WIND
 DIRECTION NEED TO BE CONSIDERED TO DETERMINE THE
 BUILDING EXPOSURE. REVISE AS REQUIRED.
 NOTE: REVISE ALL COMPONENTS AND CLADDING DESIGN
 PRESSURES ON ALL DRAWINGS ACCORDINGLY. SEE DOORS,
 WINDOWS, ROOF DIAGRAMS, ETC.
  
 3-WINDOW SCHEDULE ON SHEET A-1 ONLY IDENTIFIES EGRESS
 WINDOW #046 FOR BEDROOM #4 AND WINDOW #051 FOR BEDROOM
 #3. CLARIFY WHY THE OTHER TWO BEDROOMS ON THE SECOND
 FLOOR DON'T SPECIFY EGRESS WINDOWS. SEC. R310.2.1
 FBC-RESIDENTIAL.
  
 4- PROVIDE COMPLETE DETAILS AND SPECIFICATIONS FOR
 STAIRWAY CONSTRUCTION: DIMENSIONS, RISERS,
 TREADS,NOSING, HANDRAILS, GUARDRAILS, ETC. SHOWING
 COMPLIANCE WITH SEC. R311.7 FBC-RESIDENTIAL.
  
 5- LIVING AREA SLIDING GLASS DOORS. BASED ON PLANS AND
 DOOR SCHEDULE, IT LOOKS LIKE THERE ARE TWO SLIDING
 GLASS DOORS MULLED TOGETHER. SPECIFY MULLION SIZE AND
 CONNECTIONS AND PROVIDE PRODUCT APPROVAL.. SEC. R301.1
 FBC-RESIDENTIAL.
  
 6- MASTER BATHROOM TOILET ROOM NEEDS A DOOR THAT
 PROVIDES 29" MIN. CLEAR OPENING AS REQUIRED BY SEC.
 R320.1.1 FBC-RESIDENTIAL.
  
 7- SPECIFY ATTIC ACCESS SIZE AND LOCATION AT MASTER
 BEDROOM, DINING AREA AND TWO FRONT GARAGES AS REQUIRED
 BY SEC. R807 FBC-RESIDENTIAL.
  
 8- BALCONY GUARDRAIL: IT IS NOT CLEAR WHAT TYPE OF
 RAILING IS GOING TO BE INSTALLED. SECOND FLOOR PLANS
 SPECIFIES 36" HIGH RAILING W/ PICKETS TO REJECT A 4"
 DIAM. SPHERE, WHILE REAR ELEVATION SHOWS GUARDRAIL THAT
 LOOKS LIKE A CABLE SYSTEM. REVISE AS REQUIRED TO MATCH
 AND PROVIDE THE DETAILS AND SPECIFICATIONS FOR THE
 CONSTRUCTION OF THE GUARDRAIL SHOWING COMPLIANCE WITH
 TABLE R301.5, SEC. R311.7.8 AND SEC. R312.1
 FBC-RESIDENTIAL.
 NOTE: SUBSEQUENT SHOP DRAWINGS ARE TO CONFIRM THAT
 DESIGN DETAILS AND SPECIFICATIONS ARE MET.
  
 9- PROVIDE DETAILS/SPECIFICATIONS FOR STAIRWAY
 FIREBLOCKING AS REQUIRED BY SEC. R302.11
 FBC-RESIDENTIAL.
  
 10- PROVIDE COMPLETE DETAILS AND SPECIFICATIONS FOR
 DRAFSTOPPING IN SECOND FLOOR AREAS AS REQUIRED BY SEC.
 R302.12 FBC-RESIDENTIAL.
  
 11- PROVIDE DETAILS AND SPECIFICATIONS FOR DECORATIVE
 SHUTTERS CONSTRUCTION AND INSTALLATION. SPECIFY
 FASTENING. SEC. R301.2.1 FBC-RESIDENTIAL.
  
 12- HOUSE IS DESIGNED WITH UNVENTED ATTIC. ENGINEER IS
 SPECIFYING SPRAY FOAM INSULATION. PROVIDE ICC
 EVALUATION REPORT FOR THE FOAM INSULATION TO VERIFY
 COMPLIANCE WITH SEC. R316 FBC-RESIDENTIAL.
 NOTE: ENGINEER OF RECORD TO REVIEW AND APPROVE THE
 REPORT IN WRITING PRIOR TO SUBMITTAL TO THIS OFFICE.
  
 13- BUILDING THERMAL ENVELOPE. ENGINEER OF RECORD NEEDS
 TO DEPICT THE BUILDING THERMAL ENVELOPE. NEED TO
 SPECIFY INSULATION MATERIALS AND THEIR R-VALUES.(ROOF,
 WALLS, RAISED FLOOR ABOVE GARAGE, ETC.) AS REQUIRED BY
 SEC. R103.2 FBC-ENERGY CONSERVATION.
  
 14- PROVIDE COMPLETE DETAILS/SPECIFICATIONS FOR THE
 CONSTRUCTION OF THE ENTRY CANOPY A SHOWN ON FRONT
 ELEVATION AND BUILDING SECTION A-A. SEC. R301.1
 FBC-RESIDENTIAL. ALSO, CLEARLY SPECIFY ROOF FINISH AND
 PROVIDE PRODUCT APPROVAL.
  
 15- PROVIDE STRUCTURAL BUCK DETAIL AND FASTENING
 SPECIFICATIONS FOR NEW OVERHEAD GARAGE DOOR. SPECIFY
 ANCHOR TYPE, SIZE AND SPACING NOT PER PRODUCT APPROVAL.
 SEC. R301.1 FBC-RESIDENTIAL.
  
 16- PROVIDE DOOR (SWING AND SLIDING GLASS
 DOORS)STRUCTURAL BUCK DETAIL SHOWING COMPLIANCE WITH
 SEC. R609.7.2.1 FBC-RESIDENTIAL. SPECIFY STRUCTURAL
 BUCK SIZE AND FASTENING NOT PER PRODUCT APPROVAL.
 NOTE: STRUCTURAL BUCK NEEDS TO PROVIDE FULL SUPPORT TO
 THE DOOR FRAME AS REQUIRED BY SEC. R609.7.2.1
 FBC-RESIDENTIAL.
  
 17- ROOF ZONE DIAGRAM ON SHEET S-5. REVISE EDGE STRIP
 DIMENSION. THE MINIMUM DIMENSION IS 4'-0" NOT 3'-0" AS
 REQUIRED BY NOTE "A" ON FIGURE R301.2(7)
 FBC-RESIDENTIAL. REVISE AS REQUIRED.
  
 18- PRODUCT APPROVALS (NOTE: PRODUCT APPROVALS WILL BE
 REVIEWED ONCE DESIGN PRESSRUES ARE REVISED. SEE ITEM #2
 ABOVE):
 PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC 61G20-3.001
 FOR:
 (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED
 SUBMITTAL. CONTRACTOR TO ADVISE IF SUBMITTING NOW OR
 LATER AS A DEFERRED SUBMITTAL).
 A)ALL EXTERIOR DOORS.
 B)ALL WINDOWS.
 C)WINDOW MULLIONS (NOTE: NEED TO SPECIFY MULLION SIZE
 TO VERIFY PRESSURES. SEC. R301.2.1 FBC-RESIDENTIAL).
 D)HURRICANE SHUTTERS IF DOORS AND WINDOWS DON'T HAVE
 IMPACT GLAZING. AND, PROVIDE COMPLETE INSTALLATION
 SCHEDULE. SEE CITY SAMPLE.
 E)METAL ROOF (IF USED).
 F)ROOF TILE AND CLEARLY MARK ADHESIVE PADDY SIZE TO BE
 USED AS REQUIRED BY CITY POLICY FOR ALL ROOFING PERMITS
 TO VERIFY COMPLIANCE WITH THE DESIGN PRESSURES OF SEC
 R301.2.1 FBC-RESIDENTIAL.
 G)ROOFING UNDERLAYMENT SPECIFIED ON PLANS.
 H)ROOF TILE ADHESIVE ( IF USED) LISTED IN ROOF TILE
 PRODUCT APPROVAL.
 I)HIP & RIDGE METAL SUPPORT TO BE USED.
 J)BALCONY UNDERLAYMENT SPECIFIED ON PLANS TO RECEIVE
 TILE.
 K) FLAT ROOF. AND, CLEARLY MARK WHICH APPROVED ASSEMBLY
 IS GOING TO BE INSTALLED TO VERIFY COMPLIANCE WITH THE
 DESIGN PRESSURES OF SEC. R301.1 FBC-RESIDENTIAL.
 NOTE: IF THE SELECTED ASSEMBLY DOESN'T MEET THE DESIGN
 PRESSURES FOR ALL ROOF ZONES, THEN SIGNED AND SEALED
 RAS 117 CALCULATIONS ARE REQUIRED.
  
 19- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS
 REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS.
  
 20- ENERGY CALCULATIONS:
 A)THE BUILDING'S OWNER, THE OWNER'S ARCHITECT, OR OTHER
 AUTHORIZED AGENT LEGALLY DESIGNATED BY THE OWNER SHALL
 CERTIFY AT THE OWNER/AGENT LINE AT THE BOTTOM OF FORM
 THAT THE BUILDING IS IN COMPLIANCE WITH THE CODE, AS
 PER SECTION 553.907, FLORIDA STATUTES, PRIOR TO
 RECEIVING THE PERMIT TO BEGIN CONSTRUCTION OR
 RENOVATION AS REQUIRED BY SECTION R103.1.1.2 FBC-ENERGY
 CONSERVATION.
  
 B)PROVIDE COMPLETE INFORMATION ON TOP OF FORM,
 INCLUDING OWNER NAME, BUILDER NAME (IF AVAILABLE),
 CORRECT PERMIT OFFICE (CITY OF WEST PALM BEACH NOT PALM
 BEACH COUNTY), JURISDICTION NUMBER (THIS JURISDICTION
 IS 604700). SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION.
  
 C)PROVIDE THE NAME OF THE PERSON DOING THE CALCULATIONS
 AS REQUIRED BY SEC. R405.4.2.1 FBC-ENERGY CONSERVATION.
  
 D)SPACES INFORMATION ON PAGE 2 IS MISSING THE NUMBER OF
 OCCUPANTS. PROVIDE INFORMATION. WHY THERE ARE "0"
 OCCUPANTS IN A FIVE BEDROOM HOUSE?. REVISE AS REQUIRED.
 SEC. R101.5.1.1.2 FBC- ENERGY CONSERVATION.
  
 E)REVISE WINDOWS ORIENTATION AND WINDOWS OVERHANG
 SEPARATION TO MATCH PLANS. SEE SURVEY FOR HOUSE
 ORIENTATION AND EXTERIOR ELEVATIONS FOR WINDOWS
 OVERHANG SEPARATION. SEC. R101.5.1.1.2 FBC- ENERGY
 CONSERVATION.
  
 F)GARAGE FLOOR AREA ON PAGE 6 IS INCORRECT. SEE PLANS
 AND REVISE AS REQUIRED. SEC. R101.5.1.1.2 FBC- ENERGY
 CONSERVATION.
  
 G)BUILDER TO COMPLETE THE ENERGY PERFORMANCE LEVEL
 (EPL) DISPLAY CARD. SEC. R405.4.3 FBC-ENERGY
 CONSERVATION.
  
 21- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO
 LOW. VALUATION TO INCLUDE ALL LABOR, MATERIALS,
 CONTRACTOR'S OVERHEAD AND PROFIT AND DESIGN
 PROFESSIONAL FEES AS REQUIRED BY SEC. 109.3 CITY
 AMENDMENTS. VALUATION UPDATED TO $1,084,583. OWES
 $3873.02.
  
 WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE
 ORIGINAL REVIEW COMMENT WITH A DESCRIPTION OF WHERE AND
 HOW THE COMMENT WAS ADDRESSED WILL HELP TO EXPEDITE THE
 REVIEW PROCESS. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2023-06-22 Cont ID  
Sent By rperdomo Date 2023-06-22 Time 14:30 Rev Time 0.00
Received By rperdomo Date 2023-06-22 Time 08:09 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2023-03-08 Cont ID  
Sent By rperdomo Date 2023-03-08 Time 16:13 Rev Time 0.00
Received By rperdomo Date 2023-03-08 Time 15:29 Sent To  
Notes
2023-03-08 16:13:09ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW
  
 1. ELECTRICAL RISER DIAGRAM ON PAGE 014 E-2 HAS
 DISCREPANCIES WITH THE PANEL RATINGS (100 AMPS & 150
 AMPS) ON PAGE 013 E-1.
  
 END OF COMMENTS
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
 RUBEN PEREZ PERDOMO, P.E.
 ELECTRICAL PLANS EXAMINER
 561-805-6738
 [email protected]

Review Stop ENG ENGINEERING CSD
Rev No 1 Status P Date 2023-06-13 Cont ID  
Sent By parking Date 2023-06-13 Time 15:32 Rev Time 0.00
Received By lquinone Date 2023-06-13 Time 15:32 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 1 Status N Date 2023-05-11 Cont ID  
Sent By ccole Date 2023-05-11 Time 12:22 Rev Time 0.00
Received By ccole Date 2023-02-27 Time 12:22 Sent To  
Notes
2023-02-27 12:26:50GAS SHALL BE UNDER A SEPARATE PERMIT PER OWNER REQUEST.
 COMMENTS REMOVED.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2023-07-10 Cont ID  
Sent By jgomez Date 2023-07-10 Time 11:23 Rev Time 0.00
Received By jgomez Date 2023-06-09 Time 08:19 Sent To I
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2023-03-14 Cont ID  
Sent By jgomez Date 2023-03-14 Time 13:24 Rev Time 0.00
Received By jgomez Date 2023-02-22 Time 11:55 Sent To I
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status F Date 2023-07-10 Cont ID  
Sent By jgomez Date 2023-07-10 Time 10:39 Rev Time 0.00
Received By jgomez Date 2023-07-10 Time 10:38 Sent To  
Notes
2023-07-10 10:43:15IMPACT FEES QUESTIONNAIRE IS UPLOADED. PERMIT LIBRARIAN
 WILL EMAIL THE COUNTY WHEN PLANS ARE APPROVED.

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2023-03-14 Cont ID  
Sent By jgomez Date 2023-03-14 Time 13:22 Rev Time 0.00
Received By jgomez Date 2023-03-14 Time 13:22 Sent To  
Notes
2023-03-14 13:23:07IMPACT FEES
 PLANS NEED TO BE REVIEWED BY PALM BEACH COUNTY FOR
 IMPACT FEE ASSESSMENT.
 PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON
 APPROVAL AND FEE PAYMENT (IF ANY), PLEASE UPLOAD THE
 RECEIPT TO YOUR PROJECT OR EMAIL IT TO
 [email protected] .
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2023-02-27 Cont ID  
Sent By medwards Date 2023-02-27 Time 16:36 Rev Time 0.00
Received By medwards Date 2023-02-27 Time 16:36 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2023-06-12 Cont ID  
Sent By ccole Date 2023-06-12 Time 16:32 Rev Time 0.00
Received By ccole Date 2023-06-12 Time 16:25 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2023-02-27 Cont ID  
Sent By ccole Date 2023-02-27 Time 11:55 Rev Time 0.00
Received By ccole Date 2023-02-27 Time 10:18 Sent To  
Notes
2023-02-27 11:59:481ST REVIEW FBC-2020 RES. PLUMBING
 PERMIT- 23020716
 2/27/23
  
 CODES IN EFFECT:
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION
 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET A-5 PLUMBING RISER: PLEASE INCREASE THE SIZE
 OF THE BUILDING DRAIN FROM 3-INCH TO 4-INCH AT THE
 POINT WHERE THE 3-INCH BRANCH FROM THE MASTER BATH AND
 BATHS 2 & 3 CONNECTS- TABLES P3004.1 & TABLE P3005.4.2
 FBC RES.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status N Date 2023-07-10 Cont ID  
Sent By jgomez Date 2023-07-10 Time 10:47 Rev Time 0.00
Received By jgomez Date 2023-07-10 Time 10:47 Sent To  
Notes
2023-07-10 10:48:34PROVIDE COMPLETE ROOFING PRODUCT APPROVALS FOR REVIEW
 UNDER SEPARATE SUB-PERMIT. JG.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2023-03-14 Cont ID  
Sent By jgomez Date 2023-03-14 Time 13:23 Rev Time 0.00
Received By jgomez Date 2023-03-14 Time 13:23 Sent To  
Notes
2023-03-14 13:24:06SEE BUILDING REVIEW COMMENTS UNDER PRODUCT APPROVALS.
 JG.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2023-07-10 Cont ID  
Sent By jgomez Date 2023-07-10 Time 11:14 Rev Time 0.00
Received By jgomez Date 2023-07-10 Time 11:07 Sent To  
Notes
2023-07-10 11:17:29DIGITAL SIGNATURE REVIEW COMMENTS:
  
 1- DRAWINGS SIGNED AND SEALED BY ENGINEER OF RECORD
 SHAWN M. STAMBAUGH P.E.:
 ENGINEER'S DIGITAL SIGNATURE DOESN'T COMPLY WITH THE
 REQUIREMENTS OF FBPE.
 A) THE TEXT BOX LANGUAGE MUST NOT BE A PART OF THE
 DIGITAL SIGNATURE ITSELF.
 SEE FBPE.ORG/LEGAL/SIGNING-AND-SEALING-ENGINEERING-DOCU
 MENTS/ AND REVISE AS REQUIRED.
  
 B) ENGINEER'S DIGITAL SIGNATURE DOESN'T COMPLY WITH THE
 REQUIREMENTS OF FBPE. THE TEXT BOX LANGUAGE MUST BE
 IDENTICAL TO THE SAMPLES PUBLISHED BY FBPE. SEE FBPE.OR
 G/LEGAL/SIGNING-AND-SEALING-ENGINEERING-DOCUMENTS/???
 AND REVISE AS REQUIRED TO MATCH.
  
 C) ALSO, IT IS NOT CLEAR IF THE DOCUMENT IS DIGITALLY
 SIGNED OR ELECTRONICALLY SIGNED. SEE TEXT BOX LANGUAGE
 SUBMITTED NOW AND COMPARE TO TEXT BOX LANGUAGE REQUIRED
 BY FBPE. AND, REVISE AS REQUIRED.
  
 NOTE:
 THESE COMMENTS WERE VERIFIED WITH THE FBPE
 INVESTIGATOR. THE TEXT BOX REQUIREMENTS APPLY.
  
 61G15-23.004 PROCEDURES FOR DIGITALLY SIGNING AND
 SEALING ELECTRONICALLY TRANSMITTED PLANS,
 SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS.
  
 61G15-23.005 PROCEDURES FOR ELECTRONICALLY SIGNING AND
 SEALING ELECTRONICALLY TRANSMITTED PLANS,
 SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS.
  
 2-SITE DRAINAGE PLAN SIGNED AND SEALED BY EDITH T.L.
 BAMBER P.E.:
 DRAWING HAS AN ENGINEER'S SELF-CERTIFIED DIGITAL
 SIGNATURE. ENGINEER CANNOT SELF-CERTIFY THE DIGITAL
 SIGNATURE. THIRD PARTY CERTIFICATION IS REQUIRED BY FAC
 61G15-23.004. (NOTE: ENGINEER TO CONTACT THE BOARD OF
 ENGINEER'S FOR SELF-CERTIFIED DIGITAL SIGNATURE
 QUESTIONS).
  
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2023-02-27 Cont ID  
Sent By ccole Date 2023-02-27 Time 12:37 Rev Time 0.00
Received By ccole Date 2023-02-27 Time 12:27 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2023-03-24 Cont ID  
Sent By AVolcy Date 2023-03-24 Time 11:49 Rev Time 0.00
Received By avolcy Date 2023-03-24 Time 11:49 Sent To  
Notes
2023-03-24 11:50:36SEPARATE PERMIT REQUIRED FOR:
 FENCE/WALL, DRIVEWAY, POOL, GENERATOR,
 MECHANICAL/AC/POOL EQUIPMENT, IRRIGATION, LANDSCAPE,
 ACCESSORY STRUCTURE, OTHER
  