Plan Review Details - Permit 23020650
Plan Review Stops For Permit 23020650
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2023-03-22 Cont ID  
Sent By jgomez Date 2023-03-22 Time 09:09 Rev Time 0.00
Received By jgomez Date 2023-03-22 Time 08:47 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2023-03-15 Cont ID  
Sent By jgomez Date 2023-03-15 Time 18:27 Rev Time 0.00
Received By jgomez Date 2023-03-15 Time 18:10 Sent To  
Notes
2023-03-15 18:27:59RESIDENTIAL (R3) BUILDING REVIEW COMMENTS
 CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS.
 PERMIT #23020650
 7312 HORIZON DR
  
 1- GENERATOR CONCRETE PAD ENGINEERING HAS A COPY OF THE
 ENGINEER'S DIGITAL SIGNATURE. NEED ORIGINAL
 SEAL/SIGNATURE WHEN SUBMITTED FOR PUBLIC RECORDS.
 ELECTRONIC SUBMITTALS NEED VERIFIABLE DIGITAL
 SIGNATURE.
  
 2- THE ENGINEER IS LIMITING THE USE OF THIS CONCRETE
 PAD ENGINEERING TO A SPECIFIC LOCATION (ZIP CODE AND
 COMPANY). ACCORDING TO THIS, THE CONCRETE PAD
 ENGINEERING IS VOID BECAUSE THE LOCATION OF THIS
 PROJECT DOESN'T MATCH THAT LIMITATION. PROVIDE
 ENGINEERING FOR THIS SITE SPECIFIC LOCATION. SEC.
 107.2.1 CITY AMENDMENTS.
  
 WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE
 ORIGINAL REVIEW COMMENT WITH A DESCRIPTION OF WHERE AND
 HOW THE COMMENT WAS ADDRESSED WILL HELP TO EXPEDITE THE
 REVIEW PROCESS. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2023-03-02 Cont ID  
Sent By mpeterso Date 2023-03-02 Time 15:36 Rev Time 0.00
Received By mpeterso Date 2023-03-02 Time 15:30 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 2 Status N Date 2023-03-20 Cont ID  
Sent By ccole Date 2023-03-20 Time 16:21 Rev Time 0.00
Received By ccole Date 2023-03-17 Time 16:20 Sent To  
Notes
2023-03-17 16:22:20GAS UNDER SEPARATE PERMIT PER CONTRACTOR REQUEST 3/20.
  
  

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2023-03-16 Cont ID  
Sent By ccole Date 2023-03-16 Time 12:28 Rev Time 0.00
Received By ccole Date 2023-03-16 Time 12:28 Sent To  
Notes
2023-03-16 12:29:251ST REVIEW FBC-2020 RES. GAS
 PERMIT- 23020650
 3/16/23
 CODES IN EFFECT:
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION
 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED. PLEASE REVIEW THE COMMENTS
 BELOW AND NOTE- THE CONTRACTOR HAS THE OPTION OF
 REQUESTING A SEPARATE PERMIT FOR THE GAS PIPING SYSTEM.
  
 1) PROVIDE A COMPLETE GAS RISER DRAWING THAT INCLUDES
 THE NEW GAS PIPING TO THE GENERATOR AND EXISTING GAS
 PIPING AND APPLIANCES AT THE RESIDENCE- SECTION G2412.3
 & G2412.4 FBC RES. WPB BUILDING DEPT. RECORDS INDICATE
 PREVIOUS GAS PIPING PERMIT- 07050504. REFER TO FBC RES.
 CHAPTER 24 FUEL GAS- THE NEW RISER SHALL INDICATE:
 A) DELIVERY PRESSURE AT THE METER.
 B) TOTAL BTU LOAD AND INDIVIDUAL APPLIANCE BTU LOADS.
 C) TYPES AND SIZES OF PIPING.
 D) TOTAL DEVELOPED LENGTH OF THE SYSTEM FROM THE METER
 TO THE MOST REMOTE APPLIANCE OUTLET.
 E) BRANCH AND CUT PIPE LENGTH MEASUREMENTS.
 F) LOCATIONS OF REGULATORS, SHUTOFF VALVES.
 G) OUTLET PRESSURES AT REGULATORS.
 H) LOCATIONS AND TYPES OF PIPE SLEEVES.
 I) PIPE SIZING TABLES.
 2) SUBMIT A GAS SUB-PERMIT APPLICATION- SECTION 105.1
 WPB.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2023-03-22 Cont ID  
Sent By jgomez Date 2023-03-22 Time 09:09 Rev Time 0.00
Received By jgomez Date 2023-03-16 Time 16:14 Sent To I
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2023-03-16 Time   Rev Time 0.00
Received By amcgrego Date 2023-02-15 Time 10:38 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status N Date 2023-03-17 Cont ID  
Sent By ccole Date 2023-03-17 Time 16:20 Rev Time 0.00
Received By ccole Date 2023-03-17 Time 16:20 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status N Date 2023-03-16 Cont ID  
Sent By ccole Date 2023-03-16 Time 12:28 Rev Time 0.00
Received By ccole Date 2023-03-16 Time 12:02 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2023-03-22 Cont ID  
Sent By jgomez Date 2023-03-22 Time 09:09 Rev Time 0.00
Received By jgomez Date 2023-03-22 Time 09:09 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2023-03-15 Cont ID  
Sent By jgomez Date 2023-03-15 Time 18:20 Rev Time 0.00
Received By jgomez Date 2023-03-15 Time 18:17 Sent To  
Notes
2023-03-15 18:21:30SIGNATURE REVIEW:
  
 1- GENERATOR CONCRETE PAD ENGINEERING HAS A COPY OF THE
 ENGINEER'S DIGITAL SIGNATURE. NEED ORIGINAL
 SEAL/SIGNATURE WHEN SUBMITTED FOR PUBLIC RECORDS.
 ELECTRONIC SUBMITTALS NEED VERIFIABLE DIGITAL
 SIGNATURE.
  
 ENGINEERS
 61G15-23.004 PROCEDURES FOR DIGITALLY SIGNING AND
 SEALING ELECTRONICALLY TRANSMITTED PLANS,
 SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS.

Review Stop Z ZONING
Rev No 1 Status P Date 2023-03-10 Cont ID  
Sent By AVolcy Date 2023-03-10 Time 11:11 Rev Time 0.00
Received By avolcy Date 2023-03-10 Time 11:11 Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved