Plan Review Stops For Permit 23020444 |
Review Stop |
AD |
ADDRESSING |
Rev No |
1 |
Status |
F |
Date |
2023-05-31 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2023-05-31 |
Time |
16:36 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2023-05-31 |
Time |
16:36 |
Sent To |
|
|
Notes |
2023-05-31 16:37:11 | WORK APPEARS TO BE FOR THE REAR BUILDING WITH THE | | ADDRESS OF 835 ARDMORE RD, CURRENLTY ONLY ONE ADDRESS | | IS ASSIGNED TO THE REAR BUILDING AND IT WOULD APPEAR | | THAT A SEOCONDARY UNIT IS WANTED ON THE REAR UNIT TO | | GIVE A TOTAL OF THREE UNITS ON THE PARCEL. A THIRD | | ADDRESS MAY NEED TO BE ASSIGNED IF ZONING APPROVES AN | | ADDITIONAL UNIT PLEASE CONTACT [email protected] OR | | CALL 561-805-6659 ONCE ZONING APPROVES THEIR REVIEW. |
|
|
Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
Rev No |
1 |
Status |
F |
Date |
2023-06-20 |
|
|
Cont ID |
|
Sent By |
lbond |
Date |
2023-06-20 |
Time |
10:08 |
Rev Time |
0.00 |
Received By |
lbond |
Date |
2023-06-20 |
Time |
10:18 |
Sent To |
|
|
Notes |
2023-06-20 10:09:04 | BUILDING REVIEW COMMENTS: | | | | W.P.B. PERMIT: 23020444 | | | | REVIEWED: 6.20.2023 | | | | FLORIDA BUILDING CODE,7TH EDITION (2020) | | FBC[AMENDED] = 2017 CHAPTER 1 WPB AMENDMENTS (SEE LINK | | BELOW) | | HTTPS://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/ | | BUILDING-PERMIT-FORMS | | FBC BUILDING | | FBC EXISTING BUILDING | | | | COMMENTS: | | | | ASBESTOS PLAN REVIEW: FAILED | | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | CONTRACTOR, ON LETTERHEAD, STATING: | | | | THE INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM | | COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH | | COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE | | GIVEN TIMELY. | | | | ADDITIONAL INFORMATION REGARDING ASBESTOS REQUIREMENTS | | CAN BE FOUND ON THEIR WEBSITE: | | HTTPS://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVIC | | ES/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION | | -RENOVATION.HTML | | | | IF YOU HAVE ANY QUESTIONS OR CONCERNS, PLEASE DO NOT | | HESITATE TO CONTACT ME | | | | LOUIS BOND, AIA | | BUILDING PLANS EXAMINER II | | DEVELOPMENT SERVICES DEPT. | | BUILDING DIVISION | | 401 CLEMATIS STREET | | WEST PALM BEACH, FLORIDA 33401 | | PH: 561-805-6729 | | FX: 561-805-6676 | | EMAIL: [email protected] | | | | | | NOTES: | | PLEASE PROVIDE COMMENT RESPONSE SHEET TO EXPLAIN HOW | | EACH COMMENT IS BEING ADDRESSED. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2023-06-20 |
|
|
Cont ID |
|
Sent By |
lbond |
Date |
2023-06-20 |
Time |
10:15 |
Rev Time |
0.00 |
Received By |
lbond |
Date |
2023-06-20 |
Time |
10:15 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2023-06-07 |
|
|
Cont ID |
|
Sent By |
rperdomo |
Date |
2023-06-07 |
Time |
16:09 |
Rev Time |
0.00 |
Received By |
rperdomo |
Date |
2023-06-07 |
Time |
15:34 |
Sent To |
|
|
Notes |
2023-06-07 16:10:28 | FLORIDA BUILDING CODE 2020 7TH EDITION | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED | | NFPA 70 2017 EDITION | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW | | | | 1. PROVIDE INFORMATION OF SERVICE EQUIPMENT DISCONNECT | | (SERVICE OVERCURRENT PROTECTION) AND SERVICE CONDUCTORS | | AS PER NEC 230. | | | | 2. PANEL SCHEDULE IN ACCORDANCE WITH NEC 408.4(A). | | | | END OF COMMENTS | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM. | | | | RUBEN P. PERDOMO, P.E. | | ELECTRICAL PLANS EXAMINER/ INSPECTOR | | 561-805-6738 | | [email protected] |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
N |
Date |
2023-05-30 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2023-05-30 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2023-05-30 |
Time |
13:30 |
Sent To |
|
|
Notes |
2023-05-30 13:32:50 | A DUPLEX/2 SEPARATE UNITS DOES NOT REQUIRE A LIFE | | SAFETY REVIEW BY FIRE. | | | | | | PETER LEDUC | | FIRE MARSHAL | | 561-804-4709 | | [email protected] | | |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
F |
Date |
2023-07-19 |
|
|
Cont ID |
|
Sent By |
amhamilt |
Date |
2023-07-19 |
Time |
09:47 |
Rev Time |
0.00 |
Received By |
amhamilt |
Date |
2023-07-19 |
Time |
09:47 |
Sent To |
|
|
Notes |
2023-07-19 09:49:07 | THE PERMIT HAS FAILED FOR THE FOLLOWING REASON(S) | | | | SEE ZONING COMMENTS | | | | ANNE HAMILTON | | HISTORIC PRESERVATION PLANNER | | [email protected] | | 561.822.1428 | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2023-07-20 |
|
|
Cont ID |
|
Sent By |
aoliver |
Date |
2023-07-20 |
Time |
09:32 |
Rev Time |
0.00 |
Received By |
aoliver |
Date |
2023-05-26 |
Time |
09:53 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2023-06-20 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2023-06-20 |
Time |
13:32 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2023-06-20 |
Time |
11:03 |
Sent To |
|
|
Notes |
2023-06-20 13:32:19 | PLAN DENIED | | 1) REFER TO SECTION R403.3.6 AIR HANDLING UNITS | | SHOW ACCESS TO AIR HANDLER #1 AND WHERE THE | | AIR HANDLER IS LOCATED IN THE ATTIC. 2020 FBC | | ENERGY. | | 2) SHOW RETURN AIR AND SERVICE ACCESS FOR | | AIR HANDLER#2 SECTION 305.1 AND M1602.2 | | RETURN AIR OPENING | | PLAN REVIEW BY HAROLD MOSER | | [email protected] | | OFFICE 561-805=6732 | | FAX 561-805-6676 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2023-06-01 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2023-06-01 |
Time |
10:16 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2023-06-01 |
Time |
10:07 |
Sent To |
|
|
Notes |
2023-06-01 10:17:02 | 1ST REVIEW FBC-2020 RES. PLUMBING | | PERMIT- 23020444 | | 6/1/23 | | | | CODES IN EFFECT: | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION | | 2020 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) SHEET 2: PLEASE PROVIDE PIPE SIZES ON THE PLUMBING | | RISERS DRAWINGS- SEC. 107.3.5.3 WPB. | | | | 2) SHEETS 1 & 2: THE PLAN DESIGNER SHALL PROVIDE HIS OR | | HER PRINTED NAME AND SIGNATURE ON THE DRAWINGS- SEC. | | 107.2.1 WPB. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. | | | | CHRISTOPHER L. COLE | | MECHANICAL/PLUMBING PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
N |
Date |
2023-06-20 |
|
|
Cont ID |
|
Sent By |
lbond |
Date |
2023-06-20 |
Time |
10:15 |
Rev Time |
|
Received By |
lbond |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2023-07-19 |
|
|
Cont ID |
|
Sent By |
amhamilt |
Date |
2023-07-19 |
Time |
09:49 |
Rev Time |
0.00 |
Received By |
amhamilt |
Date |
2023-07-19 |
Time |
09:49 |
Sent To |
|
|
Notes |
2023-07-19 09:49:59 | THE PERMIT HAS FAILED FOR THE FOLLOWING REASON(S) | | | | CITY RECORDS INDICATE ONLY TWOUNITS ARE PERMITTED AT | | THIS ADDRESS, NOT 3. PLEASE REVISE. | | | | ANNE HAMILTON | | HISTORIC PRESERVATION PLANNER | | [email protected] | | 561.822.1428 | | |
|
|