Plan Review Details - Permit 23020331
Plan Review Stops For Permit 23020331 |
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2023-04-11 |
|
|
Cont ID |
|
Sent By |
rperdomo |
Date |
2023-04-11 |
Time |
10:51 |
Rev Time |
0.00 |
Received By |
rperdomo |
Date |
2023-04-11 |
Time |
10:42 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2023-03-13 |
|
|
Cont ID |
|
Sent By |
rperdomo |
Date |
2023-03-13 |
Time |
10:49 |
Rev Time |
0.00 |
Received By |
rperdomo |
Date |
2023-03-13 |
Time |
10:24 |
Sent To |
|
|
Notes |
2023-03-13 10:49:15 | FLORIDA BUILDING CODE 2020 7TH EDITION | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED | | NFPA 70 2017 EDITION | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW | | | | 1. PROVIDE LOAD CALCULATION FOR SERVICE, INCLUDE | | EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF SERVICE | | IS ADEQUATE. | | NEC 215, 220, 230. | | 2. PROVIDE PANEL SCHEDULE. NEC 208.4(A) | | | | END OF COMMENTS | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM. | | | | RUBEN PEREZ PERDOMO, P.E. | | ELECTRICAL PLANS EXAMINER | | 561-805-6738 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2023-02-20 |
|
|
Cont ID |
|
Sent By |
rperdomo |
Date |
2023-02-20 |
Time |
09:27 |
Rev Time |
0.00 |
Received By |
rperdomo |
Date |
2023-02-20 |
Time |
09:21 |
Sent To |
|
|
Notes |
2023-02-20 09:27:16 | FLORIDA BUILDING CODE 2020 7TH EDITION | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED | | NFPA 70 2017 EDITION | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW | | | | 1. PROVIDE LOAD CALCULATION FOR SERVICE, INCLUDE | | EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF SERVICE | | IS ADEQUATE. | | NEC 215, 220, 230. | | 1. PROVICE PANEL SCHEDULE. NEC 208.4(A) | | | | END OF COMMENTS | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM. | | | | RUBEN PEREZ PERDOMO, P.E. | | ELECTRICAL PLANS EXAMINER | | 561-805-6738 | | [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2023-04-13 |
|
|
Cont ID |
|
Sent By |
aoliver |
Date |
2023-04-13 |
Time |
09:21 |
Rev Time |
0.00 |
Received By |
aoliver |
Date |
2023-04-10 |
Time |
08:30 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2023-03-14 |
|
|
Cont ID |
|
Sent By |
aoliver |
Date |
2023-03-14 |
Time |
09:20 |
Rev Time |
0.00 |
Received By |
aoliver |
Date |
2023-03-09 |
Time |
16:19 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2023-02-23 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2023-02-23 |
Time |
12:09 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2023-02-14 |
Time |
10:09 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2023-03-10 |
|
|
Cont ID |
|
Sent By |
rwbrown |
Date |
2023-03-10 |
Time |
06:52 |
Rev Time |
0.00 |
Received By |
rwbrown |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2023-02-16 |
|
|
Cont ID |
|
Sent By |
rwbrown |
Date |
2023-02-16 |
Time |
09:58 |
Rev Time |
0.00 |
Received By |
rwbrown |
Date |
2023-02-16 |
Time |
09:58 |
Sent To |
|
|
Notes |
2023-02-16 10:00:08 | 1ST PLUMBING REVIEW | | | | THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED | | BY RYAN BROWN WITH THE FOLLOWING COMMENTS. | | | | 1. 2017 WPB AMEND 107.3.5.3 (12) - SUBMIT A FLOOR PLAN | | SHOWING THE LOCATION OF THE NEW WATER HEATER. ALSO SHOW | | WHERE THE OLD ONE WAS IF IT IS IN A DIFFERENT LOCATION | | THAN THE NEW ONE. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM. | | | | | | RYAN W. BROWN | | CHIEF PLUMBING INSPECTOR | | OFFICE: 561-805-6692 | | CELL: 561-517-4293 | | EMAIL: [email protected] | | | | | | V7 FPC - 2020 FLORIDA PLUMBING CODE | | V7 FGC - 2020 FLORIDA FUEL GAS | | V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE | | V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE | | V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE | | V7 FEC - 2020 FLORIDA ENERGY CONSERVATION | | 2021 F.S. - 2021 FLORIDA STATUTES | | 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE | | 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE | | FBC CHAPTER 1 | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
N |
Date |
2023-02-16 |
|
|
Cont ID |
|
Sent By |
rwbrown |
Date |
2023-02-16 |
Time |
10:00 |
Rev Time |
|
Received By |
rwbrown |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |