Plan Review Details - Permit 23020091
Plan Review Stops For Permit 23020091
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2023-05-15 Cont ID  
Sent By pvalenti Date 2023-05-15 Time 15:07 Rev Time 0.00
Received By pvalenti Date 2023-05-15 Time 15:07 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2023-04-21 Cont ID  
Sent By jbrooks Date 2023-04-21 Time 14:36 Rev Time 0.00
Received By jbrooks Date 2023-04-21 Time 13:56 Sent To  
Notes
2023-04-21 14:36:45JONATHAN BROOKS JR.
 BUILDING PLANS EXAMINER
 WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM
 PHONE (561) 805-6656
 EMAIL: [email protected]
  
 1ST REVIEW: FBC 2020 7TH EDITION
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
 TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT
 CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX.
  
 1. PROVIDE THE FOLLOWING INFORMATION FOR MIAMI-DADE NOA
 NO.: 20-00131.01 FOR THE PROPOSED FLAT ROOF SYSTEM TO
 BE USED CORRESPONDING TO ENGINEERS CALCULATIONS. COVER
 PAGE #1, INSTALLATION INSTRUCTIONS FOR SYSTEM A (2)
 PAGE(S) #8 AND LIMITATIONS PAGE(S) #18. ALL APPLICABLE
 DETAILS AND ATTACHMENTS MUST BE CLEARLY IDENTIFIED ON
 THE PRODUCT APPROVAL DRAWINGS. NOTE: MUST BE SIGNED BY
 ARCHITECT/ENGINEER BEFORE SUBMITTING. REVIEW STAMP WITH
 INITIALS.
 2. FBC B 107.2.1. SUBMITTED MIAMI-DADE COUNTY NOA NO.
 20-0902.03 HAS EXPIRED AND IS NO LONGER VALID. PROVIDE
 A COMPLETE SET OF 2020 CODE VERSION PRODUCT
 APPROVALS/NOA'S FOR THE PROPOSED FLAT ROOF SYSTEM TO BE
 USED. ALL APPLICABLE DETAILS AND ATTACHMENTS MUST BE
 CLEARLY IDENTIFIED ON THE PRODUCT APPROVAL DRAWINGS.
 DETAILS AND ATTACHMENTS NOT SPECIFICALLY COVERED IN
 PRODUCT APPROVALS WILL NEED SITE-SPECIFIC ENGINEERING
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2023-03-31 Cont ID  
Sent By jbrooks Date 2023-03-31 Time 09:50 Rev Time 0.00
Received By jbrooks Date 2023-03-31 Time 07:32 Sent To  
Notes
2023-03-31 09:51:07JONATHAN BROOKS JR.
 BUILDING PLANS EXAMINER
 WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM
 PHONE (561) 805-6656
 EMAIL: [email protected]
  
 1ST REVIEW: FBC 2020 7TH EDITION
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
 TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT
 CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX.
  
 1. FBC B 107.2.1 PLEASE CLARIFY; SUBMITTED APPROVED
 DRAWINGS INDICATES REROOFING LOWER BARREL TILE ROOF
 ONLY. IF ADDITIONAL REROOFING/ROOFING WILL BE PERFORMED
 INDICATE ON ROOF DRAWING AND CLEARLY IDENTIFY AREAS TO
 RECEIVE NEW ROOFING WITH ROOFING SYSTEM TO BE USED.
 SECOND REQUEST
 2. FBC B 107.2.1 SUBMITTED PRODUCT APPROVAL FL11288-R21
 COVERS MULTIPLE ATTACHMENT LIMITATIONS. SELECTED
 ATTACHMENT LIMITATION SYSTEM #14 PAGE #7 DO NOT MEET OR
 EXCEED -85 MAXIMUM DESIGN PRESSURE REQUIREMENT. SELECT
 SYSTEM THAT MEETS OR EXCEEDS THIS REQUIREMENT. ALL
 APPLICABLE DETAILS AND ATTACHMENTS MUST BE CLEARLY
 IDENTIFIED ON THE PRODUCT APPROVAL DRAWINGS. SECOND
 REQUEST.
 3. FBC B 107.3.4.1. SUBMIT ALL PRODUCT
 APPROVALS/NOA???S THAT SHALL BE USED FOR THIS ROOFING
 PROJECT TO THE REGISTERED DESIGN PROFESSIONAL IN
 RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD
 THEM TO THE BUILDING OFFICIAL WITH A NOTATION
 INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE
 BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO
 THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL
 ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED
 SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING
 OFFICIAL. ALL APPLICABLE DETAILS AND ATTACHMENTS MUST
 BE CLEARLY IDENTIFIED ON THE PRODUCT APPROVAL DRAWINGS.
 NOTE: MUST BE SIGNED BY ARCHITECT/ENGINEER BEFORE
 SUBMITTING. REVIEW STAMP WITH INITIALS. SECOND REQUEST.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2023-02-06 Cont ID  
Sent By jbrooks Date 2023-02-06 Time 12:39 Rev Time 0.00
Received By jbrooks Date 2023-02-06 Time 08:13 Sent To  
Notes
2023-02-06 12:40:00JONATHAN BROOKS JR.
 BUILDING PLANS EXAMINER
 WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM
 PHONE (561) 805-6656
 EMAIL: [email protected]
  
 1ST REVIEW: FBC 2020 7TH EDITION
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
 TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT
 CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX.
  
 1. FBC B 107.2.1 PLEASE CLARIFY; SUBMITTED APPROVED
 DRAWINGS INDICATES REROOFING LOWER BARREL TILE ROOF
 ONLY. IF ADDITIONAL REROOFING/ROOFING WILL BE PERFORMED
 INDICATE ON ROOF DRAWING AND CLEARLY IDENTIFY AREAS TO
 RECEIVE NEW ROOFING WITH ROOFING SYSTEM TO BE USED.
 2. FBC B 107.2.1. PLEASE PROVIDE ENGINEER'S SIGNED AND
 SEALED FASTENER SPACING DETAIL WITH CALCULATIONS FOR
 PERIMETERS AND CORNERS AS PER PRODUCT APPROVAL
 LIMITATIONS #7 OF MIAMI-DADE NOA NO.: 20-0131.01 SYSTEM
 TYPE A (2). PLEASE NOTE THIS PROJECT IS LOCATED IN AN
 EXPOSURE D CATEGORY AREA.
 3. FBC B 107.2.1. PLEASE PROVIDE ENGINEER'S SIGNED AND
 SEALED FASTENER SPACING DETAIL WITH CALCULATIONS FOR
 PERIMETERS AND CORNERS AS PER PRODUCT APPROVAL
 LIMITATIONS #7 OF MIAMI-DADE NOA NO.: 17-1003.15 SYSTEM
 TYPE E (2). PLEASE NOTE THIS PROJECT IS LOCATED IN AN
 EXPOSURE D CATEGORY AREA.
 4. FBC R 301 FAC9N-3 SUBMITTED FLORIDA DBPR PRODUCT
 APPROVAL FL2533-R28 SYSTEM NO. W-77 DO NOT MEET THE
 MINIMUM ZONE 3 DESIGN PRESSURE REQUIREMENT OF -131.42
 FOR EXPOSURE CATEGORY D AREAS. PROVIDE SYSTEM THAT
 MEETS OR EXCEEDS ALL DESIGN PRESSURE REQUIREMENTS FOR
 EXPOSURE CATEGORY D/PROVIDE SIGNED AND SEALED
 ENGINEERED NAILING CALCULATIONS WITH AN APPROVED
 SYSTEM.
 5. FBC B 107.2.1 SUBMITTED PRODUCT APPROVAL FL11288-R21
 COVERS MULTIPLE ATTACHMENT LIMITATIONS. SELECTED
 ATTACHMENT LIMITATION SYSTEM #14 PAGE #7 DO NOT MEET OR
 EXCEED -85 MAXIMUM DESIGN PRESSURE REQUIREMENT. SELECT
 SYSTEM THAT MEETS OR EXCEEDS THIS REQUIREMENT. ALL
 APPLICABLE DETAILS AND ATTACHMENTS MUST BE CLEARLY
 IDENTIFIED ON THE PRODUCT APPROVAL DRAWINGS.
 6. FBC B 107.3.4.1. SUBMIT ALL PRODUCT
 APPROVALS/NOA???S THAT SHALL BE USED FOR THIS ROOFING
 PROJECT TO THE REGISTERED DESIGN PROFESSIONAL IN
 RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD
 THEM TO THE BUILDING OFFICIAL WITH A NOTATION
 INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE
 BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO
 THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL
 ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED
 SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING
 OFFICIAL. ALL APPLICABLE DETAILS AND ATTACHMENTS MUST
 BE CLEARLY IDENTIFIED ON THE PRODUCT APPROVAL DRAWINGS.
 NOTE: MUST BE SIGNED BY ARCHITECT/ENGINEER BEFORE
 SUBMITTING.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  

Review Stop HIST HISTORICAL
Rev No 2 Status P Date 2023-05-24 Cont ID  
Sent By amhamilt Date 2023-05-24 Time 15:28 Rev Time 0.00
Received By amhamilt Date 2023-05-24 Time 15:28 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2023-02-22 Cont ID  
Sent By amhamilt Date 2023-02-22 Time 10:44 Rev Time 0.00
Received By amhamilt Date 2023-02-22 Time 10:44 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2023-05-25 Cont ID  
Sent By pvalenti Date 2023-05-25 Time 09:17 Rev Time 0.00
Received By aoliver Date 2023-05-10 Time 08:41 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2023-04-25 Cont ID  
Sent By lmarchan Date 2023-04-25 Time 11:07 Rev Time 0.00
Received By lmarchan Date 2023-04-13 Time 08:45 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2023-03-31 Cont ID  
Sent By jbrooks Date 2023-03-31 Time 09:51 Rev Time 0.00
Received By jbrooks Date 2023-03-21 Time 08:04 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2023-02-23 Cont ID  
Sent By lmarchan Date 2023-02-23 Time 12:15 Rev Time 0.00
Received By lmarchan Date 2023-02-03 Time 08:23 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2023-04-21 Cont ID  
Sent By jbrooks Date 2023-04-21 Time 14:36 Rev Time 0.00
Received By jbrooks Date 2023-04-21 Time 14:36 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2023-03-31 Cont ID  
Sent By jbrooks Date 2023-03-31 Time 09:51 Rev Time 0.00
Received By jbrooks Date 2023-03-31 Time 09:51 Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved