Plan Review Stops For Permit 23020041 |
Review Stop |
AD |
ADDRESSING |
Rev No |
2 |
Status |
P |
Date |
2023-05-17 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2023-05-17 |
Time |
13:35 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2023-05-17 |
Time |
13:35 |
Sent To |
|
|
Notes |
2023-05-17 13:35:55 | PARCEL READRESSED 1040, 1060 & 1080 N RAILROAD AVE |
|
|
Review Stop |
AD |
ADDRESSING |
Rev No |
1 |
Status |
F |
Date |
2023-02-04 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2023-02-04 |
Time |
06:25 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2023-02-04 |
Time |
06:25 |
Sent To |
|
|
Notes |
2023-02-04 06:26:41 | PARCEL NEEDS TO BE READDRESSED SO THAT THE ENTRANCES ON | | THE GROUND FLOOR FALLS IN LINE WITH THE CITY'S ROAD | | CENTER LINES. ADDRESSES THAT NEED TO BE ESTABLISHED | | WOULD BE FOR THE BUILDING ITSELF, THE GROUND FLOOR | | COMMERCIAL SPACE AND THE UNITS ON THE UPPER FLOORS. | | PLEASE CONTACT [email protected] OR CALL 561-805-6659 TO | | WORK ON THE READDRESSING ISSUES. |
|
|
Review Stop |
AIPP |
ART IN PUBLIC PLACES |
Rev No |
1 |
Status |
P |
Date |
2023-03-10 |
|
|
Cont ID |
|
Sent By |
swelter |
Date |
2023-03-10 |
Time |
12:44 |
Rev Time |
|
Received By |
swelter |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2023-03-10 12:44:38 | SEE MASTER PERMIT# 23020041 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2023-07-21 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2023-07-21 |
Time |
12:33 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2023-07-21 |
Time |
11:34 |
Sent To |
|
|
Notes |
2023-07-21 11:44:31 | NEW COMMERCIAL BUILDING | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected] | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | AMENDMENT | | | | CORRECTIONS NEEDED - | | | | 1) PLEASE SHOW THE STORM WATER DRAINAGE AWAY FROM THE | | BUILDING AND AWAY FROM THE ADJACENT PROPERTY - PROVIDE | | THE CIVIL PLANS IF THEY WILL PROVIDE THE INFO NEEDED - | | PLEASE SHOW THE FOLLOWING ITEMS ON THE SITE PLAN PER - | | FBC WPB 107.2.5 SITE PLAN. THE CONSTRUCTION DOCUMENTS | | SUBMITTED WITH THE APPLICATION FOR PERMIT SHALL BE | | ACCOMPANIED BY A SITE PLAN SHOWING TO SCALE THE SIZE | | AND LOCATION OF NEW CONSTRUCTION AND EXISTING | | STRUCTURES ON THE SITE, DISTANCES FROM LOT LINES, THE | | ESTABLISHED STREET GRADES AND THE PROPOSED FINISHED | | GRADES, DEPICTING THE PROPOSED LOT DRAINAGE AND, AS | | APPLICABLE, FLOOD HAZARD AREAS, FLOODWAYS, AND DESIGN | | FLOOD ELEVATIONS; AND IT SHALL BE DRAWN IN ACCORDANCE | | WITH AN ACCURATE AND INCLUDED ON A BOUNDARY LINE | | SURVEY. (PLEASE PROVIDE CUT SECTIONS FOR ANY PROPOSED | | WATER RETAINING SWALES) | | | | 2) PLEASE SHOW THE SOUTH EXTERIOR WALL TO BE 1 HR FIRE | | RATED PER - FBC TABLE 602 | | | | 3) PLEASE SHOW THE PERCENTAGE CALCULATIONS FOR THE | | EXTERIOR SOUTH WALL SQUARE FOOTAGE VERSES THE OPENINGS | | TO COMPLY WITH FBC 705.8.1 ALLOWABLE AREA OF OPENINGS. | | THE MAXIMUM AREA OF UNPROTECTED AND PROTECTED OPENINGS | | PERMITTED IN AN EXTERIOR WALL IN ANY STORY OF A | | BUILDING SHALL NOT EXCEED THE PERCENTAGES SPECIFIED IN | | TABLE 705.8. (PER STORY) | | | | | | | | | | | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2023-05-19 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2023-05-19 |
Time |
09:40 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2023-05-19 |
Time |
09:03 |
Sent To |
|
|
Notes |
2023-05-19 09:37:32 | NEW COMMERCIAL BUILDING | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected] | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | AMENDMENT | | | | CORRECTIONS NEEDED - | | | | 1) PROVIDE THE CIVIL PLANS IF THEY WILL PROVIDE THE | | INFO NEEDED - PLEASE SHOW THE FOLLOWING ITEMS ON THE | | SITE PLAN PER - FBC WPB 107.2.5 SITE PLAN. THE | | CONSTRUCTION DOCUMENTS SUBMITTED WITH THE APPLICATION | | FOR PERMIT SHALL BE ACCOMPANIED BY A SITE PLAN SHOWING | | TO SCALE THE SIZE AND LOCATION OF NEW CONSTRUCTION AND | | EXISTING STRUCTURES ON THE SITE, DISTANCES FROM LOT | | LINES, THE ESTABLISHED STREET GRADES AND THE PROPOSED | | FINISHED GRADES, DEPICTING THE PROPOSED LOT DRAINAGE | | AND, AS APPLICABLE, FLOOD HAZARD AREAS, FLOODWAYS, AND | | DESIGN FLOOD ELEVATIONS; AND IT SHALL BE DRAWN IN | | ACCORDANCE WITH AN ACCURATE AND INCLUDED ON A BOUNDARY | | LINE SURVEY. (PLEASE PROVIDE CUT SECTIONS FOR ANY | | PROPOSED WATER RETAINING SWALES) | | | | 2) ACCESSIBLE PARKING SPACE LOCATION PLEASE SHOW THE | | ACCESSIBLE PATH FROM THE ACCESSIBLE PARKING SPACE TO | | THE ACCESSIBLE ENTRY - FBC A208.3.1 PARKING SPACES | | COMPLYING WITH 502 THAT SERVE A PARTICULAR BUILDING OR | | FACILITY SHALL BE LOCATED ON THE SHORTEST ACCESSIBLE | | ROUTE FROM PARKING TO AN ENTRANCE COMPLYING WITH 206.4. | | | | 3) CANNOT HAVE A RAMP IN THE 5 FOOT PARKING ACCESS | | AISLE - FBC A 502.4 FLOOR OR GROUND SURFACES. | | PARKING SPACES AND ACCESS AISLES SERVING THEM SHALL | | COMPLY WITH 302. ACCESS AISLES SHALL BE AT THE SAME | | LEVEL AS THE PARKING SPACES THEY SERVE. CHANGES IN | | LEVEL ARE NOT PERMITTED. | | | | 4) DRAWING A.104 SHOWS THE RESTROOM WALL COVERING AS | | "WPT" (TILE) - DRAWING A.600 SHOWS THE RESTROOM WALL | | COVERING AS "WVP" (WOOD) - PLEASE CLEARIFY THE DRAWINGS | | SHOULD MATCH - IF USING "WOOD" PLEASE PROVIDE DOCUMENTS | | THAT SHOW THE WOOD VENEER COMPLIES WITH FBC 1210.2.2 | | WALLS AND PARTITIONS. WALLS AND PARTITIONS WITHIN 2 | | FEET (610 MM) OF SERVICE SINKS, URINALS AND WATER | | CLOSETS SHALL HAVE A SMOOTH, HARD, NONABSORBENT | | SURFACE, TO A HEIGHT OF NOT LESS THAN 4 FEET (1219 MM) | | ABOVE THE FLOOR, | | | | 5) DRAWINGS SHOW THE BUILDING CONSTRUCTION TYPE AS IIB | | - PLEASE PROVIDE A NOTE ON THE DRAWINGS THAT THE | | EXTERIOR WOOD SHEATHING USED ON THE EXTERIOR WALL NEEDS | | TO BE FIRE RETARDANT PER FBC 603.1 | | | | 6) DRAWINGS LS.101, LS.102, A.101, A.102, A.600, A.602 | | DO NOT SHOW AS DIGITALLY SIGNED IN ADOBE READER - | | | | SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE | | DIGITALLY/ELECTRONICALLY SIGNED TO BE USED IN | | ELECTRONIC PLAN REVIEW. (A CERTIFICATE-BASED DIGITAL | | SIGNATURE (OFTEN JUST CALLED A DIGITAL SIGNATURE) IS A | | SPECIFIC TYPE OF E-SIGNATURE). | | | | | | | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2023-02-16 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2023-02-16 |
Time |
11:36 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2023-02-16 |
Time |
08:25 |
Sent To |
|
|
Notes |
2023-02-16 11:32:37 | NEW COMMERCIAL BUILDING | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected] | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | AMENDMENT | | | | CORRECTIONS NEEDED - | | | | 1) DOORS AND WINDOWS SHALL NOT OPEN OR PROJECT INTO THE | | PUBLIC RIGHT-OF-WAY. FBC 3202.2 | | | | 2) DRAWING A-103 - BOTTOM AND TOP STAIR RAIL EXTENSIONS | | ARE SHOWN AS TURNING - STAIR HANDRAIL EXTENSIONS CANNOT | | TURN IF THE STAIRS DO NOT CONTINUE - WHERE HANDRAILS | | ARE NOT CONTINUOUS BETWEEN FLIGHTS, THE HANDRAILS SHALL | | EXTEND HORIZONTALLY FBC 1014.6 | | | | 3) PLEASE SHOW EXTERIOR "CASEMENT COMPOSITE WALL PANEL | | SYSTEM" ATTACHMENT DETAILS OR PROVIDE A PRODUCT | | APPROVAL. FBC 1609 | | | | 4) PLEASE SHOW EXTERIOR "METAL WALL PANEL" ATTACHMENT | | DETAILS OR PROVIDE A PRODUCT APPROVAL. FBC 1609 | | | | 5) PLEASE SHOW THE FOLLOWING ITEMS ON THE SITE PLAN PER | | - FBC WPB 107.2.5 SITE PLAN. THE CONSTRUCTION DOCUMENTS | | SUBMITTED WITH THE APPLICATION FOR PERMIT SHALL BE | | ACCOMPANIED BY A SITE PLAN SHOWING TO SCALE THE SIZE | | AND LOCATION OF NEW CONSTRUCTION AND EXISTING | | STRUCTURES ON THE SITE, DISTANCES FROM LOT LINES, THE | | ESTABLISHED STREET GRADES AND THE PROPOSED FINISHED | | GRADES, DEPICTING THE PROPOSED LOT DRAINAGE AND, AS | | APPLICABLE, FLOOD HAZARD AREAS, FLOODWAYS, AND DESIGN | | FLOOD ELEVATIONS; AND IT SHALL BE DRAWN IN ACCORDANCE | | WITH AN ACCURATE AND INCLUDED ON A BOUNDARY LINE | | SURVEY. (PLEASE PROVIDE CUT SECTIONS FOR ANY PROPOSED | | WATER RETAINING SWALES) | | | | 6) ACCESSIBLE PARKING SPACE LOCATION - FBC A208.3.1 | | PARKING SPACES COMPLYING WITH 502 THAT SERVE A | | PARTICULAR BUILDING OR FACILITY SHALL BE LOCATED ON THE | | SHORTEST ACCESSIBLE ROUTE FROM PARKING TO AN ENTRANCE | | COMPLYING WITH 206.4. | | | | 7) ACCESSIBLE RESTROOM = DRAWING A-104 MENS ROOM DOOR | | IS SHOWN SWINGING INTO THE CLEAR FLOOR SPACE - FBC | | 603.2.3 WHERE THE TOILET ROOM OR BATHING ROOM IS FOR | | INDIVIDUAL USE AND A CLEAR FLOOR SPACE COMPLYING WITH | | 305.3 IS PROVIDED WITHIN THE ROOM BEYOND THE ARC OF THE | | DOOR SWING. | | | | 8) PLEASE PROVIDE A SURVEY. | | | | 9) SEPARATE PERMITS ARE REQUIRED FOR - DUMPSTER | | ENCLOSURE, PARKING LOT. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2023-07-28 |
|
|
Cont ID |
|
Sent By |
mpeterso |
Date |
2023-07-28 |
Time |
13:15 |
Rev Time |
0.00 |
Received By |
mpeterso |
Date |
2023-07-28 |
Time |
13:15 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2023-05-26 |
|
|
Cont ID |
|
Sent By |
mpeterso |
Date |
2023-05-26 |
Time |
11:00 |
Rev Time |
0.00 |
Received By |
mpeterso |
Date |
2023-05-26 |
Time |
10:48 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2023-02-15 |
|
|
Cont ID |
|
Sent By |
mpeterso |
Date |
2023-02-15 |
Time |
08:24 |
Rev Time |
0.00 |
Received By |
mpeterso |
Date |
2023-02-15 |
Time |
08:24 |
Sent To |
|
|
Notes |
2023-02-15 08:35:28 | ELECTRIC REVIEW FAILED | | | | 1) PLEASE PROVIDE AN ELECTRIC RISER DIAGRAM. NEC 215.5 | | | | 2) PLEASE PROVIDE AN ELECTRIC LOAD CALCULATION. NEC | | 215.5 | | | | 3) PLEASE PROVIDE AN ELECTRIC LIGHTING PLAN. FBC 107.2 | | | | 4) PLEASE PROVIDE A NOTE STAING , LOW VOLTAGE, FIRE | | ALRM, ACCESS CONTOL, SECURITY, AUDIO, VIDEO, SITE | | LIGHTING, SIGN, AND OTHER LOW VOLTAGE SYSTEM WIRING | | REQUIRE A SEPARATE PERMIT. | | | | 5) PROVIDE A ROOF POWER PLAN AS APPLICABLE. FBC 107.2 | | | | 6) PROVIDE ACTUAL GROUNDING ELECTRODE AND OTHER | | GROUNDING CONDUCTOR SIZES FOR ELECTRICAL SERVICE. NOT | | JUST NEC CODE REFERENCES. NEC 250 FBC 107.2 | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. | | | | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | BUILDING CODE 2020 7TH ED. | | FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020 | | 7TH EDITION | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | 7TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION | | NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | V/R, | | | | MICHAEL PETERSON | | ELECTRICAL PLANS EXAMINER | | [email protected] | | 561-805-6746 | | |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
3 |
Status |
|
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
Received By |
|
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
2 |
Status |
P |
Date |
2023-05-25 |
|
|
Cont ID |
|
Sent By |
lquinone |
Date |
2023-05-25 |
Time |
07:20 |
Rev Time |
0.00 |
Received By |
lquinone |
Date |
2023-05-25 |
Time |
07:20 |
Sent To |
|
|
Notes |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
1 |
Status |
P |
Date |
2023-02-07 |
|
|
Cont ID |
|
Sent By |
rrossano |
Date |
2023-02-07 |
Time |
|
Rev Time |
|
Received By |
rrossano |
Date |
2023-02-07 |
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
P |
Date |
2023-07-20 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2023-07-20 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2023-07-20 |
Time |
10:04 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2023-05-19 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2023-05-19 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2023-05-19 |
Time |
14:42 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2023-02-06 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2023-02-06 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2023-02-06 |
Time |
11:04 |
Sent To |
|
|
Notes |
2023-02-06 11:26:20 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | 1) SHEET LS 101- THERE APPEARS TO BE AN OCCUPANY LOAD | | OF 150 WITHIN THE PLAN LEGEND. | | | | PER NFPA 101, CH 12 NEW ASSEMBLY & CH 7 MEANS OF | | EGRESS, THE OCCUPANY CLACULATION IS SQ FT / EITHER 7 OR | | 15. | | | | EACH ASSEMBLY SPACE IS REQUIRED TO BE CALCULATED | | SEPARATLY AND RECORDED. | | | | PLEASE REVIEW AND PROVIDE THE SEPARATE CALCULATIONS OF | | THE AREA SERVED. | | | | | | | | 2) THERE ARE INDICATIONS WITHIN THE DOOR SCHEDULE THAT | | DO NOT APPEAR TO MEET THE NFPA 101 CH 7, MEANS OF | | EGRESS & CH 12 NEW ASSEMBLY REQUIREMENTS FOR ASSEMBLY | | OCCUPANCIES. | | | | 7.2.1.7* PANIC HARDWARE AND FIRE EXIT HARDWARE. | | | | 7.2.1.7.1 WHERE A SIDE-HINGED OR PIVOTED-SWINGING DOOR | | ASSEMBLY IS | | REQUIRED TO BE EQUIPPED WITH PANIC OR FIRE EXIT | | HARDWARE, SUCH HARDWARE | | SHALL MEET ALL OF THE FOLLOWING CRITERIA: | | (1) IT SHALL CONSIST OF A CROSS BAR OR A PUSH PAD, WITH | | THE LENGTH OF THE | | ACTUATING PORTION OF THE CROSS BAR OR PUSH PAD NOT LESS | | THAN ONE-HALF | | OF THE WIDTH OF THE DOOR LEAF. | | (2) IT SHALL BE MOUNTED AS FOLLOWS: | | (A) NEW INSTALLATIONS SHALL BE NOT LESS THAN 34 IN. | | (865 MM), AND | | NOT MORE THAN 48 IN. (1220 MM), ABOVE THE FLOOR. | | (B) EXISTING INSTALLATIONS SHALL BE NOT LESS THAN 30 | | IN. (760 MM), | | AND NOT MORE THAN 48 IN. (1220 MM), ABOVE THE FLOOR. | | (3) IT SHALL BE CONSTRUCTED SO THAT A HORIZONTAL FORCE | | NOT TO EXCEED 15 LBF | | (66 N) ACTUATES THE CROSS BAR OR PUSH PAD AND LATCHES | | | | 7.2.1.7.3 REQUIRED PANIC HARDWARE AND FIRE EXIT | | HARDWARE, IN OTHER THAN | | DETENTION AND CORRECTIONAL OCCUPANCIES AS OTHERWISE | | PROVIDED IN CHAP TERS 22 AND 23, SHALL NOT BE EQUIPPED | | WITH ANY LOCKING DEVICE, SET SCREW, | | OR OTHER ARRANGEMENT THAT PREVENTS THE RELEASE OF THE | | LATCH WHEN PRESSURE | | IS APPLIED TO THE RELEASING DEVICE | | | | 12.2.2.2 DOORS. | | 12.2.2.2.1 DOORS COMPLYING WITH 7.2.1 SHALL BE | | PERMITTED | | | | 12.2.2.2.3 ANY DOOR IN A REQUIRED MEANS OF EGRESS FROM | | AN AREA HAVING | | AN OCCUPANT LOAD OF 100 OR MORE PERSONS SHALL BE | | PERMITTED TO BE PRO VIDED WITH A LATCH OR LOCK ONLY IF | | THE LATCH OR LOCK IS PANIC HARDWARE OR | | FIRE EXIT HARDWARE COMPLYING WITH 7.2.1.7, UNLESS | | OTHERWISE PERMITTED | | BY ONE OF THE FOLLOWING: | | (1) THIS REQUIREMENT SHALL NOT APPLY TO DELAYED-EGRESS | | ELECTRICAL LOCK ING SYSTEMS AS PERMITTED IN 12.2.2.2.5. | | (2) THIS REQUIREMENT SHALL NOT APPLY TO SENSOR-RELEASE | | OF ELECTRICAL | | LOCKING SYSTEMS AS PERMITTED IN 12.2.2.2.6 | | | | 12.2.2.2.4 LOCKING DEVICES COMPLYING WITH 7.2.1.5.5 | | SHALL BE PERMITTED | | TO BE USED ON A SINGLE DOOR OR A SINGLE PAIR OF DOORS | | IF BOTH OF THE FOL LOWING CONDITIONS APPLY: | | (1) THE DOOR OR PAIR OF DOORS SERVE AS THE MAIN EXIT | | AND THE ASSEMBLY | | OCCUPANCY HAS AN OCCUPANT LOAD NOT GREATER THAN 500. | | (2) ANY LATCHING DEVICES ON SUCH A DOOR(S) FROM AN | | ASSEMBLY OCCU PANCY HAVING AN OCCUPANT LOAD OF 100 OR | | MORE ARE RELEASED BY | | PANIC HARDWARE OR FIRE EXIT HARDWARE. | | | | PLEASE REVIEW AND ENSURE THE PROPER EXIT HARDWARE IS | | PROVIDED AT EACH DOOR. | | | | | | | | 3) SHEET LS 101- THERE IS AN INDICATION REGARDING THE | | KNOX BOX LOCATION BEING COORDINATED WITH PBC FIRE | | RESCUE. | | | | THAT IS THE INCORRECT JURISDICTION. WEST PALM BEACH | | FIRE DEPARTMENT IS THE CORRECT JURISDICTION. | | | | PLEASE REVIEW AND CORRECT. | | | | | | 4) SHEETS FP - THERE IS AN INDICATION OF A FIRST FLOOR | | FIRE PROTECTION PLAN BUT NO INDICATION OF A SECOND | | FLOOR PLAN. | | | | FOR CLARIFICATION PURPOSES PLEASE PROVIDE A SECOND | | FLOOR PLAN OR JUSTIFICATION WHY FIRE SPRINKLER | | PROTECTION IS NOT BEING PROVIDED WITH CODE REFERENCES. | | | | | | | | 5) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | ABOVE. | | | | | | 6) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | RE-SUBMITTAL OF THE ABOVE. DELINEATE | | | | | | PETER LEDUC | | FIRE MARSHAL | | 561-804-4709 | | [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
|
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
Received By |
amcgrego |
Date |
2023-07-19 |
Time |
11:20 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2023-06-09 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2023-06-09 |
Time |
09:11 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2023-05-17 |
Time |
17:34 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2023-03-13 |
|
|
Cont ID |
|
Sent By |
aoliver |
Date |
2023-03-13 |
Time |
08:39 |
Rev Time |
0.00 |
Received By |
aoliver |
Date |
2023-02-03 |
Time |
14:54 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2023-02-16 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2023-02-16 |
Time |
11:36 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2023-02-16 |
Time |
11:36 |
Sent To |
|
|
Notes |
2023-02-16 11:37:02 | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF | | | | UPON APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE | | RECEIPT TO YOUR PROJECT OR EMAIL IT TO | | [email protected] . | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2023-08-07 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2023-08-07 |
Time |
09:10 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2023-08-07 |
Time |
08:51 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2023-06-09 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2023-06-09 |
Time |
09:08 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2023-06-09 |
Time |
07:02 |
Sent To |
|
|
Notes |
2023-06-09 09:07:15 | PLAN DENIED | | 1) PROVIED A EQUIPMENT SCHEDULE FOR THE AIR | | CONDITIONING | | UNITS ON THE PLAN SECTION 107. | | 2) THERE WAS NO 2ND FLOOR MECHANICAL PLAN SUBMITTED. | | 3) REFER TO SECTION 607.5.3 FIRE PARTITIONS FBC (M). | | MISSING A NUMBER OF FIRE DAMPERS. | | PLAN REVIEW BY HAROLD MOSER | | [email protected] | | OFFICE 561-805-6732 | | FAX 561-805-6676 | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2023-02-24 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2023-02-07 |
Time |
06:31 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2023-02-07 |
Time |
06:31 |
Sent To |
|
|
Notes |
2023-02-07 06:32:25 | 1ST REVIEW FMC | | PERMIT: 23020041 | | | | CODES IN EFFECT: 2020 | | | | FBC- FLORIDA BUILDING CODE | | FMC- FLORIDA MECHANICAL CODE | | FEC- FLORIDA ENERGY CONSERVATION | | FGC- FLORIDA FUEL GAS | | FEX- FLORIDA EXISTING BUILDING CODE | | FRC- FLORIDA RESIDENTIAL BUILDING CODE | | F.S.- FLORIDA STATUTES | | FAC- FLORIDA ACCESSIBILITY CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) PROVIDE THE MECHANICAL DRAWINGS THAT SHOW THE | | SYSTEMS AND DUCTWORK THAT IS SPECIFIED ON SHEET M-600. | | FBC 107.3.5 | | | | 2) PROVIDE THE ENERGY CALCULATIONS FOR THE MECHANICAL | | DESIGN FOR THIS SHELL. FEC C402 | | | | 3) PROVIDE THE MECHANICAL EQUIPMENT SIZING CALCULATIONS | | FOR THIS SHELL DESIGN. FEC C403.2.1 | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM. | | | | MICHAEL EDWARDS | | MECHANICAL EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL. 33401 | | 561-805-6728 | | [email protected] | | | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2023-07-20 |
|
|
Cont ID |
|
Sent By |
rwbrown |
Date |
2023-07-20 |
Time |
10:37 |
Rev Time |
0.00 |
Received By |
rwbrown |
Date |
2023-07-20 |
Time |
10:37 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2023-05-22 |
|
|
Cont ID |
|
Sent By |
rwbrown |
Date |
2023-05-22 |
Time |
07:46 |
Rev Time |
0.00 |
Received By |
rwbrown |
Date |
2023-05-22 |
Time |
07:45 |
Sent To |
|
|
Notes |
2023-05-22 07:51:45 | 1ST PLUMBING REVIEW | | | | THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED | | BY RYAN BROWN WITH THE FOLLOWING COMMENTS. | | | | 1. DONE | | | | 2. DONE | | | | 3. DONE | | | | 4. DONE | | | | 5. ENGINEERING PERMITS ARE FOR THE RIGHT-OF-WAYS AND DO | | NOT REPLACE THE REQUIREMENTS FOR BUILDING PERMITS - | | 2017 WPB AMENDS 107.3.5.1.3 - BE AWARE THAT IF | | IRRIGATION IS INSTALLED, IT WILL REQUIRE A SEPARATE | | PERMIT. | | | | 6. ENGINEERING PERMITS ARE FOR THE RIGHT-OF-WAYS AND DO | | NOT REPLACE THE REQUIREMENTS FOR BUILDING PERMITS - | | 2017 WPB AMENDS 107.3.5.1.3 - SITE PLAN SHOWING THE | | LOCATION OF THE WATER SERVICE, SEWER SERVICE, GREASE | | TRAPS, BACKFLOWS, ETC. | | | | 7. DONE | | | | 8. ENGINEERING PERMITS ARE FOR THE RIGHT-OF-WAYS AND DO | | NOT REPLACE THE REQUIREMENTS FOR BUILDING PERMITS - | | 2017 WPB AMEND - 105.1/107.3 -- THE BACKFLOW DEVICE AT | | THE UTILITY CONNECTION AND THE GREASE TRAP REQUIRE | | SEPARATE PERMITS THAT ARE REQUIRED TO BE APPLIED FOR | | PRIOR TO ISSUANCE OF THE PRIMARY PERMIT (AS | | APPLICABLE). YOU CAN SUBMIT AN APPLICATION "TBD" (TO BE | | DETERMINED) IF YOU DO NOT HAVE A CONTRACTOR SELECTED BY | | EMAILING A COMPLETED PERMIT APPLICATION TO | | [email protected]. AFTER YOU HAVE THE PERMIT(S) | | GENERATED, NOTIFY ME VIA EMAIL OR NOTE IN THE RESPONSE | | LETTER AND I WILL COMPLY THIS COMMENT. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM. | | | | | | RYAN W. BROWN | | CHIEF PLUMBING INSPECTOR | | OFFICE: 561-805-6692 | | CELL: 561-517-4293 | | EMAIL: [email protected] | | | | | | V7 FPC - 2020 FLORIDA PLUMBING CODE | | V7 FGC - 2020 FLORIDA FUEL GAS | | V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE | | V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE | | V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE | | V7 FEC - 2020 FLORIDA ENERGY CONSERVATION | | 2021 F.S. - 2021 FLORIDA STATUTES | | 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE | | 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE | | FBC CHAPTER 1 | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2023-02-09 |
|
|
Cont ID |
|
Sent By |
rwbrown |
Date |
2023-02-09 |
Time |
12:45 |
Rev Time |
0.00 |
Received By |
rwbrown |
Date |
2023-02-09 |
Time |
12:45 |
Sent To |
|
|
Notes |
2023-02-09 13:02:37 | 1ST PLUMBING REVIEW | | | | THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED | | BY RYAN BROWN WITH THE FOLLOWING COMMENTS. | | | | 1. 2020 FPC 403.1.1 - PLEASE SHOW THE FIXTURE | | CALCULATIONS AND THE SHOW THAT YOU ARE PROVIDING THE | | MINIMUM NUMBER OF FIXTURES. | | | | 2. 2017 WPB AMENDS 107.3.5.1.3 - SHOW A RISER DIAGRAM | | THAT INCLUDES THE DRAIN, WASTE AND VENT SYSTEM AND THE | | WATER DISTRIBUTION SYSTEM. | | | | 3. 2017 WPB AMENDS 107.3.5.1.3 - SHOW THE LOCATION OF | | THE WATER HEATER AND INCLUDE DETAILS FOR A MIXING VALVE | | PER FPC 607.1.1 INSTALLED AT THE HEAT SOURCE PER 613.1. | | | | 4. 2017 WPB AMENDS 107.3.5.1.3 - SHOW A ROOF DRAINAGE | | PLAN INCLUDE GALLONS PER MINUTE, LEADER/DRAIN SIZES. | | DRAIN PIPING PLAN, OVERFLOW/SCUPPER SIZES ETC. | | | | 5. 2017 WPB AMENDS 107.3.5.1.3 - BE AWARE THAT IF | | IRRIGATION IS INSTALLED, IT WILL REQUIRE A SEPARATE | | PERMIT. | | | | 6. 2017 WPB AMENDS 107.3.5.1.3 - SITE PLAN SHOWING THE | | LOCATION OF THE WATER SERVICE, SEWER SERVICE, GREASE | | TRAPS, BACKFLOWS, ETC. | | | | 7. 2020 FPC 607.2 - PROVIDE A CIRCULATING LOOP IF THE | | LENGTH OF THE HOT WATER SUPPLY EXCEEDS 50 FEET. IF A | | RETURN LOOP IS PROVIDED, THE RETURN SHALL BE IN | | COMPLIANCE WITH 2020 FPC 607.2.2 AND RETURN TO THE COLD | | WATER INLET PIPE OF THE WATER HEATER AND THE COLD WATER | | INLET PIPE OR THE HOT WATER RETURN CONNECTION OF THE | | THERMOSTATIC MIXING VALVE. | | | | 8. 2017 WPB AMEND - 105.1/107.3 -- THE BACKFLOW DEVICE | | AT THE UTILITY CONNECTION AND THE GREASE TRAP REQUIRE | | SEPARATE PERMITS THAT ARE REQUIRED TO BE APPLIED FOR | | PRIOR TO ISSUANCE OF THE PRIMARY PERMIT (AS | | APPLICABLE). YOU CAN SUBMIT AN APPLICATION "TBD" (TO BE | | DETERMINED) IF YOU DO NOT HAVE A CONTRACTOR SELECTED BY | | EMAILING A COMPLETED PERMIT APPLICATION TO | | [email protected]. AFTER YOU HAVE THE PERMIT(S) | | GENERATED, NOTIFY ME VIA EMAIL OR NOTE IN THE RESPONSE | | LETTER AND I WILL COMPLY THIS COMMENT. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM. | | | | | | RYAN W. BROWN | | CHIEF PLUMBING INSPECTOR | | OFFICE: 561-805-6692 | | CELL: 561-517-4293 | | EMAIL: [email protected] | | | | | | V7 FPC - 2020 FLORIDA PLUMBING CODE | | V7 FGC - 2020 FLORIDA FUEL GAS | | V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE | | V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE | | V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE | | V7 FEC - 2020 FLORIDA ENERGY CONSERVATION | | 2021 F.S. - 2021 FLORIDA STATUTES | | 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE | | 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE | | FBC CHAPTER 1 | | |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
N |
Date |
2023-02-16 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2023-02-16 |
Time |
11:37 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2023-02-16 |
Time |
11:37 |
Sent To |
|
|
Notes |
2023-02-16 11:37:32 | ROOFING SYSTEM TO BE DEFERRED |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
3 |
Status |
P |
Date |
2023-07-21 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2023-07-21 |
Time |
12:33 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2023-07-21 |
Time |
12:33 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
F |
Date |
2023-05-19 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2023-05-19 |
Time |
10:18 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2023-05-19 |
Time |
10:18 |
Sent To |
|
|
Notes |
2023-05-19 10:20:30 | SIGNATURE REVIEW | | | | CORRECTIONS NEEDED - | | | | 1) DRAWINGS LS.101, LS.102, A.101, A.102, A.600, A.602 | | DO NOT SHOW AS DIGITALLY SIGNED IN ADOBE READER - | | | | SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE | | DIGITALLY/ELECTRONICALLY SIGNED TO BE USED IN | | ELECTRONIC PLAN REVIEW. (A CERTIFICATE-BASED DIGITAL | | SIGNATURE (OFTEN JUST CALLED A DIGITAL SIGNATURE) IS A | | SPECIFIC TYPE OF E-SIGNATURE). | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2023-02-15 |
|
|
Cont ID |
|
Sent By |
mpeterso |
Date |
2023-02-15 |
Time |
08:40 |
Rev Time |
0.00 |
Received By |
mpeterso |
Date |
2023-02-15 |
Time |
08:40 |
Sent To |
|
|
Notes |
2023-02-15 08:41:53 | SIGNATURE REVIEW FAILED | | 1) SHEET A 602 DOES NOT DETAIL THE REQUIRED DIGITAL | | SIGNATURE OF THE EOR/AOR AS REQUIRED. PLEASE CORRECT AS | | OUTLINED BELOW. | | | | FS471/FS481 DOCUMENTS PREPARED BY ARCHITECT/ENGINEER OF | | RECORD AND SUBMITTED FOR PUBLIC RECORD ARE TO BE | | DIGITALLY SEALED AND SIGNED. | | | | PLEASE SUBMIT DIGITALLY SEALED AND SIGNED PLANS | | FOLLOWING PROJECTDOX INSTRUCTIONS | | | | MICHAEL PETERSON | | ELECTRICAL PLANS EXAMINER | | [email protected] | | 561-805-6746 | | | 2023-02-07 06:34:27 | MECHANICAL DIGITAL SIGNATURES APPROVED ME |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
|
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
Received By |
|
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2023-05-30 |
|
|
Cont ID |
|
Sent By |
ckimmerl |
Date |
2023-05-30 |
Time |
10:22 |
Rev Time |
0.00 |
Received By |
ckimmerl |
Date |
2023-05-30 |
Time |
10:20 |
Sent To |
|
|
Notes |
2023-05-30 10:22:48 | PROPOSAL FOR 444 10TH STREET HAS BEEN SUBMITTED FOR | | FORMAL SITE PLAN APPROVAL AND HAS NOT RECEIVED SAID | | APPROVAL . | | ZONING STAFF CANNOT REVIEW OR APPROVE OF THE BUILDING | | PERMIT WITHOUT FIRST RESUBMITTING AND OBTAINING THE | | SITE PLAN APPROVAL FOR FSPR 22-17 - (Z22070024). | | | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2023-03-10 |
|
|
Cont ID |
|
Sent By |
CKimmerl |
Date |
2023-03-10 |
Time |
16:35 |
Rev Time |
0.00 |
Received By |
ckimmerl |
Date |
2023-03-10 |
Time |
16:32 |
Sent To |
|
|
Notes |
2023-03-10 16:34:19 | SCOPE OF PROJECT DEMONSTRATES SUBSTANTIAL CHANGE IN | | STRUCTURE AND TRIGGERS THE PROVISIONS OF ARTICLE IV - | | SEC. 94-124 AND THE NONCOMFORMITIES SECTION OF ARTICLE | | XVI SEC. 94-515. | | THIS IS AN ALTERATION OR DEMOLITION WITH CONSTRUCTION | | OF 'NEW' STRUCTURE, THE NEW MUST BE BUILT IN COMPLIANCE | | WITH CODE PROVISIONS OF THE BPD-R DISTRICT. | | | | 1. PLEASE PROVIDE A SITE SURVEY. | | | | 2. PLEASE PROVIDE A SITE PLAN WITH SETBACKS ILLUSTRATED | | AND PROVIDE TABULAR DATA OR CALCULATIONS FOR BPD-R | | STANDARDS. RENOVATION AND ALTERATION MUST MEET | | SETBACKS, HEIGHT, BUILDING FOOTPRINT, ETC. FOR | | SUBDISTRICT. | | | | 3. PROJECT PROPOSAL APPEARS TO DEMOLISH SINGLE-FAMILY | | STRUCTURE, PLEASE PROVIDE DEMOLITION SHEETS DETAILING | | FULL SCOPE. | | | | PROPOSAL FOR 444 10TH STREET HAS BEEN SUBMITTED FOR | | FORMAL SITE PLAN APPROVAL AND HAS NOT RECEIVED SAID | | APPROVAL . | | ZONING STAFF CANNOT REVIEW OR APPROVE OF THE BUILDING | | PERMIT WITHOUT FIRST RESUBMITTING AND OBTAINING THE | | SITE PLAN APPROVAL FOR FSPR 22-17 - (Z22070024). | | | | | | CHRIS KIMMERLY, AICP | | URBAN DESIGN PLANNER | | 822-1426 [email protected] |
|
|