 |
Plan Review Details - Permit 23020018
Plan Review Stops For Permit 23020018 |
Review Stop |
AD |
ADDRESSING |
Rev No |
3 |
Status |
P |
Date |
2023-07-18 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2023-07-18 |
Time |
17:07 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2023-07-18 |
Time |
17:07 |
Sent To |
|
|
Notes |
2023-07-18 17:13:26 | PRIMARY ADDRESS FOR THE PARCEL IS NOW 130 QUADRILLE | | PLAZA DR , UPDATED PERMIT, THE FOLLOWING ADDRESSES HAVE | | ALSO BEEN APPROVED: 144 QUADRILLE PLAZA DR, 508 | | CLEMATIS ST, 510 CLEMATIS ST, 512 CLEMATIS ST. 516 | | CLEMATIS ST AND 130 QUADRILLE PLAZA DR UNITS | | 201,202,203,204,205,206,207,208,209,210, | | 211,212,213,214,215,216,217,218,219,220,221,222,301,302 | | ,303,304,305,306,307,308,309,310,311,312,313,314,315,31 | | 6,317,318,319,320,401,402, | | 403,404,405,406,407,408,409,410,411,412,413,414,415,416 | | ,417,418,419,420,421,422,423. | | |
|
|
Review Stop |
AD |
ADDRESSING |
Rev No |
2 |
Status |
F |
Date |
2023-05-16 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2023-05-16 |
Time |
15:23 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2023-05-16 |
Time |
15:23 |
Sent To |
|
|
Notes |
2023-05-16 15:24:19 | RESPONCE LETTER DATED 4.17.23 IS RESPONDING TO COMMENTS | | FROM THE HEALTH DEPARTMENT, MY COMMENTS ARE ABOUT THE | | ADDRESSES ASSOCIATED WITH THE PARCEL AND BUILD, PLEASE | | SEE MY COMMENTS: | | | | PER YOUR PPRC COMMENTS BY ROBERT BROWN: | | 8. BUILDING ADDRESS. EACH SEPARATE BUILDING, AND UNIT | | WITH AN INDEPENDENT ENTRANCE FROM THE STREET, SHALL | | HAVE A SEPARATE ADDRESS. FOR STREET ADDRESSING, CONTACT | | CAROLINE PUELL, ADDRESSING COORDINATOR, AT (561) 805 | | 6659, OR BY EMAIL: [email protected] | | | | _______________________________________________________ | | ___________________________________________ | | | | PARCEL NEEDS TO BE READDRESSED SO THAT THE ENTRANCES ON | | THE GROUND FLOOR FALLS IN LINE WITH THE CITY'S ROAD | | CENTER LINES. ADDRESSES THAT NEED TO BE ESTABLISHED | | WOULD BE FOR THE BUILDING ITSELF, THE GROUND FLOOR | | COMMERCIAL SPACE (IF APPLICABLE) AND THE UNITS ON THE | | UPPER FLOORS. PLEASE CONTACT [email protected] OR CALL | | 561-805-6659 TO WORK ON THE READDRESSING ISSUES. | | | | | | |
|
|
Review Stop |
AD |
ADDRESSING |
Rev No |
1 |
Status |
F |
Date |
2023-02-07 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2023-02-07 |
Time |
12:53 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2023-02-07 |
Time |
12:53 |
Sent To |
|
|
Notes |
2023-02-07 12:56:41 | PER YOUR PPRC COMMENTS BY ROBERT BROWN: | | 8. BUILDING ADDRESS. EACH SEPARATE BUILDING, AND UNIT | | WITH AN INDEPENDENT ENTRANCE FROM THE STREET, SHALL | | HAVE A SEPARATE ADDRESS. FOR STREET ADDRESSING, CONTACT | | CAROLINE PUELL, ADDRESSING COORDINATOR, AT (561) 805 | | 6659, OR BY EMAIL: [email protected] | | | | _______________________________________________________ | | ___________________________________________ | | | | PARCEL NEEDS TO BE READDRESSED SO THAT THE ENTRANCES ON | | THE GROUND FLOOR FALLS IN LINE WITH THE CITY'S ROAD | | CENTER LINES. ADDRESSES THAT NEED TO BE ESTABLISHED | | WOULD BE FOR THE BUILDING ITSELF, THE GROUND FLOOR | | COMMERCIAL SPACE (IF APPLICABLE) AND THE UNITS ON THE | | UPPER FLOORS. PLEASE CONTACT [email protected] OR CALL | | 561-805-6659 TO WORK ON THE READDRESSING ISSUES. | | |
|
|
Review Stop |
AIPP |
ART IN PUBLIC PLACES |
Rev No |
2 |
Status |
P |
Date |
2023-06-25 |
|
|
Cont ID |
|
Sent By |
swelter |
Date |
2023-06-25 |
Time |
17:11 |
Rev Time |
0.00 |
Received By |
swelter |
Date |
2023-06-25 |
Time |
17:11 |
Sent To |
|
|
Notes |
2023-06-25 17:11:49 | ART ASSESSMENT RCVD AND COMPLETED. |
|
|
Review Stop |
AIPP |
ART IN PUBLIC PLACES |
Rev No |
1 |
Status |
F |
Date |
2023-03-09 |
|
|
Cont ID |
|
Sent By |
swelter |
Date |
2023-03-09 |
Time |
15:26 |
Rev Time |
0.00 |
Received By |
swelter |
Date |
2023-03-09 |
Time |
15:26 |
Sent To |
|
|
Notes |
2023-03-09 15:30:01 | PROJECT MUST COMPLY WITH THE ARTLIFE ORDINANCE. | | | | ART ASSESSMENT SENT TO KEITH SPINA ON 3.9.23 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2023-06-02 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2023-06-02 |
Time |
16:43 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2023-06-02 |
Time |
16:43 |
Sent To |
|
|
Notes |
2023-06-02 16:43:08 | PLAN REVIEW COMMENTS | | | | 23020018 | | 512 CLEMATIS STREET | | 5 STORY | | III-B CONSTRUCTION TYPE | | 88 APARTMENTS | | MIXED USE | | THRESHOLD BUILDING | | | | 2ND REVIEW: FBC SEVENTH EDITION (2020) | | ROBERT MCDOUGAL, CBO | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561) 805-6714 | | [email protected] | | | | DENIED BY BUILDING | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | 1) RESOLVED. | | | | 2) [PARTIALLY RESOLVED.] THIS PROJECT IS A THRESHOLD | | BUILDING. THRESHOLD BUILDING / FL S. S. 553.71(7) | | "THRESHOLD BUILDING" MEANING ANY BUILDING WHICH IS | | GREATER THAN (3) STORIES OR 50 FT. IN HEIGHT, OR WHICH | | HAS AN ASSEMBLY OCCUPANCY CLASSIFICATION AS DEFINED IN | | THE FLORIDA BUILDING CODE WHICH EXCEEDS 5,000 SQ. FT. | | IN AREA AND AN OCCUPANT CONTENT OF GREATER THAN 500 | | PERSONS. | | | | A) RESOLVED. | | | | B) [THE REQUIRED THRESHOLD FORMS HAVE NOT BEEN | | SUBMITTED.] THRESHOLD INSPECTOR: WPB AMENDMENT 110.8.1 | | W.P.B. CONSTRUCTION SERVICES DEPARTMENT REQUEST FOR | | THRESHOLD BUILDINGS A SPECIAL INSPECTOR AS REQUIRED BY | | 553.79(5) FLORIDA STATUTES TO THE MINIMUM INSPECTIONS | | REQUIRED BY THIS CODE. THE THRESHOLD INSPECTION FORMS | | ARE REQUIRED TO BE FILED OUT BY ALL PARTIES WITH | | INTEREST, NOTARIZED AND RETURNED TO THIS OFFICE, AND | | REVIEWED AND APPROVED BEFORE PERMIT ISSUANCE WILL TAKE | | PLACE. | | | | C) [THE REQUIRED THRESHOLD BUILDING STATEMENT IS | | MISSING FROM SOME OF THE STRUCTURAL PAGES. IT IS | | REQUIRED TO BE ON ALL OF THE STRUCTURAL PLAN SHEETS.] | | THRESHOLD BLDG. REQUIRED STATEMENT: W.P.B. AMENDMENT | | 110.8.4.4 ALL PLANS FOR THE BUILDING WHICH ARE REQUIRED | | TO BE SIGNED AND SEALED BY THE ARCHITECT OR ENGINEER OF | | RECORD CONTAIN A STATEMENT THAT, TO THE BEST OF THE | | ARCHITECT'S OR ENGINEER'S KNOWLEDGE, THE PLANS AND | | SPECIFICATIONS COMPLY WITH THE APPLICABLE MINIMUM | | BUILDING CODES AND THE APPLICABLE FIRE-SAFETY STANDARDS | | AS DETERMINED BY THE LOCAL AUTHORITY IN ACCORDANCE WITH | | THIS SECTION AND CHAPTER 633 FLORIDA STATUTES. | | | | D) [THIS HAS NOT BEEN SUBMITTED.] FOR THE SPECIAL | | INSPECTOR PLEASE PROVIDE A RESUME OF INSPECTION | | EXPERIENCE ON PREVIOUS PROJECT. THE RESUME MUST BE | | ACCOMPANIED BY ALL CERTIFICATES AS SPECIFIED HEREIN. | | THE BUILDING OFFICIAL OR HIS DESIGNEE WILL REVIEW THE | | RESUME. AFTER THE RESUME IS REVIEWED, AN INTERVIEW WILL | | BE SCHEDULED. UNDER NO CIRCUMSTANCES WILL AN INSPECTOR | | BE INTERVIEWED FOR WORK WITHOUT FIRST MEETING THE ABOVE | | CRITERIA. | | | | E) [THIS HAS NOT BEEN SUBMITTED.] THE CONTRACTOR WILL | | PRODUCE A JOB SUMMARY OR HISTORY FOR THIS TYPE OF | | CONSTRUCTION. | | | | F) RESOLVED. | | | | G) [PROVISO. TO BE REVIEWED AND APPROVED BY THE | | DESIGNER OF RECORD BEFORE SUBMITTAL TO THIS OFFICE.] | | 110.8.4.3 ALL SHORING AND RESHORING PROCEDURES, PLANS | | AND DETAILS SHALL BE SUBMITTED TO THE ENFORCEMENT | | AGENCY FOR RECORDKEEPING. EACH SHORING AND RESHORING | | INSTALLATION SHALL BE SUPERVISED, INSPECTED AND | | CERTIFIED TO BE IN COMPLIANCE WITH THE SHORING | | DOCUMENTS BY THE CONTRACTOR. | | | | H) RESOLVED. | | | | I) RESOLVED. | | | | J) PLEASE CONTACT ME WITH AN EMAIL ADDRESS AND I WILL | | BE HAPPY TO SEND YOU A COPY OF THE CURRENT (OCTOBER | | 2018) GUIDELINES AND POLICIES FOR PROJECTS CONCERNING | | THRESHOLD/SPECIAL INSPECTORS AND RESIDENT INSPECTORS IF | | YOU NEED IT. | | | | 3) [NOT RESOLVED.] SUBMIT A MANAGEMENT OF TRAFFIC (MOT) | | PLAN, INCLUDING PROTECTION OF PEDESTRIANS. FBC 3301 | | | | 4) [NOT RESOLVED.] SHOW HOW THE ADJOINING PROPERTIES | | WILL BE PROTECTED FROM DAMAGE DURING CONSTRUCTION PER | | FBC 3307. | | | | 5) RESOLVED. | | | | 6) RESOLVED. | | | | 7) RESOLVED. | | | | 8) RESOLVED. | | | | 9) RESOLVED. | | | | 10) RESOLVED. | | | | 11) RESOLVED. | | | | 12) RESOLVED. | | | | 13) RESOLVED. | | | | 14) RESOLVED. | | | | 15) RESOLVED. | | | | 16) RESOLVED. | | | | 17) [NOT RESOLVED. THE STATEMENT NEEDS TO BE ON THE | | PLANS. IT SHOULD STATE THAT THIS POOL IS LIMITED TO THE | | EXCLUSIVE USE OF RESIDENTS AND THEIR GUESTS.] SHOW HOW | | THE SPA POOL WILL COMPLY WITH FBC ACCESSIBILITY SECTION | | 242.2 SWIMMING POOLS. AT LEAST TWO ACCESSIBLE MEANS OF | | ENTRY SHALL BE PROVIDED FOR SWIMMING POOLS. ACCESSIBLE | | MEANS OF ENTRY SHALL BE SWIMMING POOL LIFTS COMPLYING | | WITH 1009.2; SLOPED ENTRIES COMPLYING WITH 1009.3; | | TRANSFER WALLS COMPLYING WITH 1009.4; TRANSFER SYSTEMS | | COMPLYING WITH 1009.5; AND POOL STAIRS COMPLYING WITH | | 1009.6. AT LEAST ONE ACCESSIBLE MEANS OF ENTRY PROVIDED | | SHALL COMPLY WITH 1009.2 OR 1009.3. | | EXCEPTIONS: | | 1. WHERE A SWIMMING POOL HAS LESS THAN 300 LINEAR FEET | | (91 M) OF SWIMMING POOL WALL, NO MORE THAN ONE | | ACCESSIBLE MEANS OF ENTRY SHALL BE REQUIRED PROVIDED | | THAT THE ACCESSIBLE MEANS OF ENTRY IS A SWIMMING POOL | | LIFT COMPLYING WITH 1009.2 OR SLOPED ENTRY COMPLYING | | WITH 1009.3. | | 2. WAVE ACTION POOLS, LEISURE RIVERS, SAND BOTTOM | | POOLS, AND OTHER POOLS WHERE USER ACCESS IS LIMITED TO | | ONE AREA SHALL NOT BE REQUIRED TO PROVIDE MORE THAN ONE | | ACCESSIBLE MEANS OF ENTRY PROVIDED THAT THE ACCESSIBLE | | MEANS OF ENTRY IS A SWIMMING POOL LIFT COMPLYING WITH | | 1009.2, A SLOPED ENTRY COMPLYING WITH 1009.3, OR A | | TRANSFER SYSTEM COMPLYING WITH 1009.5. | | 3. CATCH POOLS SHALL NOT BE REQUIRED TO PROVIDE AN | | ACCESSIBLE MEANS OF ENTRY PROVIDED THAT THE CATCH POOL | | EDGE IS ON AN ACCESSIBLE ROUTE. | | | | COMMUNITY POOLS THAT ARE ASSOCIATED WITH A PRIVATE | | RESIDENTIAL COMMUNITY THAT DO NOT RECEIVE GOVERNMENTAL | | FINANCIAL ASSISTANCE OR SPONSORSHIP AND ARE LIMITED TO | | THE EXCLUSIVE OF RESIDENTS AND THEIR GUESTS ARE NOT | | COVERED BY THE ADA ACCESSIBILITY REQUIREMENTS, | | INCLUDING PROVISIONS FOR POOL LIFTS OR SLOPED ENTRIES. | | IF A SWIMMING POOL LOCATED IN A RESIDENTIAL COMMUNITY | | IS MADE AVAILABLE TO THE PUBLIC FOR RENTAL OR USE IT IS | | REQUIRED TO COMPLY WITH TITLE II OF THE ADA. SPECIFY ON | | THE PLANS THE FORMER OR SHOW COMPLIANCE WITH THE LATTER | | STATEMENTS. SEE DECLARATORY STATEMENT, DS 2013-011. | | | | 18) [NOT RESOLVED.] SUBMIT A DETAILED COST BREAKDOWN | | FOR THIS PROJECT. THIS WILL PREVENT US FROM CHARGING | | YOU DOUBLE FOR ITEMS THAT REQUIRE SEPARATE PERMITS. | | BUILDING PERMIT VALUATION. FOR PERMITTING PURPOSES, | | VALUATION OF FBC 109.3 BUILDINGS AND SYSTEMS SHALL BE | | TOTAL REPLACEMENT VALUE TO INCLUDE STRUCTURAL, | | ELECTRIC, PLUMBING, MECHANICAL, INTERIOR FINISH, | | RELATIVE SITE WORK, ARCHITECTURAL AND DESIGN FEES, | | MARKETING COSTS, OVERHEAD AND PROFIT; EXCLUDING ONLY | | LAND VALUE. VALUATION REFERENCES MAY INCLUDE THE LATEST | | PUBLISHED DATA OF NATIONAL CONSTRUCTION COST ANALYSIS | | SERVICES (MARSHALL-SWIFT, MEANS, ETC.), AS PUBLISHED BY | | INTERNATIONAL CODE CONGRESS. FINAL BUILDING PERMIT | | VALUATION SHALL BE SET BY THE BUILDING OFFICIAL. | | | | 19) [PROVISO.] COMPONENT & CLADDING PRODUCT APPROVALS | | REVIEWED BY DESIGNER OF RECORD ARE TO BE SUBMITTED TO | | THE BUILDING DIVISION, REVIEWED AND ISSUED PRIOR TO | | INSTALLATION. CONFIRM COMPLIANCE WITH PRESSURES SHOWN | | ON THE STRUCTURAL PLANS PRIOR TO SUBMITTAL. IF PRODUCT | | APPROVAL OFFERS OPTIONS, INDICATE OPTION PROPOSED, | | ESPECIALLY IF NOT ALL OPTIONS COMPLY WITH MINIMUM | | DESIGN PRESSURES. | | | | B. SEPARATE PERMITS (APPLICATIONS, PLANS, AND FEES) ARE | | REQUIRED FOR: | | LIGHT POLES/SITE LIGHTING | | FIRE ALARM | | FIRE SPRINKLER | | LOW VOLTAGE | | ACCESS | | LANDSCAPING | | IRRIGATION | | PARKING LOT | | SWIMMING POOLS AND SPAS | | GENERATORS | | ALL OTHER ITEMS OTHER THAN BMEP | | | | C. AIPP COMPLIANCE REQUIRED; VERIFICATION REQUIRED | | PRIOR TO C.O. | | | | D. SHORING/RESHORE ENGINEERING IS REQUIRED TO BE | | SUBMITTED TO THE BUILDING DIVISION FOR REVIEW. THE | | ENGINEERING IS TO BE SUBMITTED, REVIEWED AND ISSUED | | PRIOR TO CONCRETE POUR. | | | | E. A CONSTRUCTION GUARD RAIL ENGINEERED DETAIL IS | | REQUIRED TO BE PROVIDED PRIOR TO INSTALLATION. | | | | F. CONSTRUCTION HOURS - 7AM TO 7PM MON-FRI, 8AM TO 8PM | | SAT-SUN | | | | 20) RESOLVED. | | | | 21) [PARTIALLY RESOLVED. THE 12' DISTANCE FROM THE | | BUILDING TO THE CENTERLINE OF THE ALLEY IS SHOWN ON | | SHEET SP.0.1, NOT A1.1.2. THE RESPONSE LETTER STATES | | THAT THE OPENING AREA CALCULATIONS FOR THE SOUTH | | ELEVATION IS ON SHEET A3.0.1, HOWEVER, SHEET A8.1.1 WAS | | UPLOADED IN THE FILE FOR THIS SHEET. BASED ON THE 12' | | DISTANCE TO THE ALLY CENTERLINE THE PERCENT OF WALL | | AREA OPENINGS IS 45 PERCENT PER STORY.] SHOW THE | | CALCULATIONS FOR THE ALLOWABLE AREA OF OPENINGS FOR | | EACH STORY OF THE SOUTH ELEVATION AS REQUIRED BY FBC | | 705.8.1. SHOW THE DISTANCE FROM THE WEST WALL TO THE | | CENTER OF THE ALLY ON THE PLANS. | | | | 22) [NOT RESOLVED. THE AREA BREAKDOWN OF THE THIRD | | FLOOR IS MISSING SOME OF THE R-2 UNITS.] PROVIDE A | | FLOOR AREA BREAKDOWN BY OCCUPANCY TYPE FOR EACH FLOOR | | OF THE PROPOSED BUILDING. FBC 107.2.1 & 503.1 | | | | 23) PLEASE SUBMIT A RESPONSE LETTER INDICATING HOW EACH | | OF THE REVIEW COMMENTS HAS BEEN ADDRESSED. THE | | RESPONSES TO THESE COMMENTS MAY RESULT IN ADDITIONAL | | COMMENTS. | | | | NEW COMMENTS: | | | | 24) THE ENERGY COMPLIANCE DOCUMENT HAS THE NUMBER OF | | STORIES AS ONE AND THIS IS A FIVE STORY BUILDING. FBC | | 107.2.1 | | | | 25) THERE APPEARS TO BE SOME DISCREPANCIES BETWEEN THE | | GROSS BUILDING AREA (68,296 SQFT) SPECIFIED ON THE | | PLANS AND THE TOTAL AREA (98,073 SQFT) ON THE ENERGY | | FORM. FBC 107.2.1 | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2023-03-29 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2023-03-29 |
Time |
09:39 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2023-03-08 |
Time |
16:06 |
Sent To |
|
|
Notes |
2023-03-27 11:27:14 | PLAN REVIEW COMMENTS | | | | 23020018 | | 512 CLEMATIS STREET | | 5 STORY | | III-B CONSTRUCTION TYPE | | 88 APARTMENTS | | MIXED USE | | | | 1ST REVIEW: FBC SEVENTH EDITION (2020) | | ROBERT MCDOUGAL, CBO | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561) 805-6714 | | [email protected] | | | | DENIED BY BUILDING | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | 1) SUBMIT A SIGNED AND SEALED GEOTECHNICAL SOILS REPORT | | IN ACCORDANCE WITH FBC 1801.2. | | | | 2) THIS PROJECT IS A THRESHOLD BUILDING. THRESHOLD | | BUILDING / FL S. S. 553.71(7) "THRESHOLD BUILDING" | | MEANING ANY BUILDING WHICH IS GREATER THAN (3) STORIES | | OR 50 FT. IN HEIGHT, OR WHICH HAS AN ASSEMBLY OCCUPANCY | | CLASSIFICATION AS DEFINED IN THE FLORIDA BUILDING CODE | | WHICH EXCEEDS 5,000 SQ. FT. IN AREA AND AN OCCUPANT | | CONTENT OF GREATER THAN 500 PERSONS. | | | | A) FBC (CITY AMENDMENTS)110.8.1 THRESHOLD INSPECTION | | PLAN. THE ENFORCING AGENCY SHALL REQUIRE A SPECIAL | | INSPECTOR TO PERFORM STRUCTURAL INSPECTIONS ON A | | THRESHOLD BUILDING PURSUANT TO A STRUCTURAL INSPECTION | | PLAN PREPARED BY THE ENGINEER OF RECORD. THE STRUCTURAL | | INSPECTION PLAN MUST BE SUBMITTED TO THE ENFORCING | | AGENCY PRIOR TO THE ISSUANCE OF A BUILDING PERMIT FOR | | THE CONSTRUCTION OF A THRESHOLD BUILDING. THE PURPOSE | | OF THE STRUCTURAL INSPECTION PLAN IS TO PROVIDE | | SPECIFIC INSPECTION PROCEDURES AND SCHEDULES SO THAT | | THE BUILDING CAN BE ADEQUATELY INSPECTED FOR COMPLIANCE | | WITH THE PERMITTED DOCUMENTS. | | | | B) THRESHOLD INSPECTOR: WPB AMENDMENT 110.8.1 W.P.B. | | CONSTRUCTION SERVICES DEPARTMENT REQUEST FOR THRESHOLD | | BUILDINGS A SPECIAL INSPECTOR AS REQUIRED BY 553.79(5) | | FLORIDA STATUTES TO THE MINIMUM INSPECTIONS REQUIRED BY | | THIS CODE. THE THRESHOLD INSPECTION FORMS ARE REQUIRED | | TO BE FILED OUT BY ALL PARTIES WITH INTEREST, NOTARIZED | | AND RETURNED TO THIS OFFICE, AND REVIEWED AND APPROVED | | BEFORE PERMIT ISSUANCE WILL TAKE PLACE. | | | | C) THRESHOLD BLDG. REQUIRED STATEMENT: W.P.B. AMENDMENT | | 110.8.4.4 ALL PLANS FOR THE BUILDING WHICH ARE REQUIRED | | TO BE SIGNED AND SEALED BY THE ARCHITECT OR ENGINEER OF | | RECORD CONTAIN A STATEMENT THAT, TO THE BEST OF THE | | ARCHITECT'S OR ENGINEER'S KNOWLEDGE, THE PLANS AND | | SPECIFICATIONS COMPLY WITH THE APPLICABLE MINIMUM | | BUILDING CODES AND THE APPLICABLE FIRE-SAFETY STANDARDS | | AS DETERMINED BY THE LOCAL AUTHORITY IN ACCORDANCE WITH | | THIS SECTION AND CHAPTER 633 FLORIDA STATUTES. | | | | D) FOR THE SPECIAL INSPECTOR PLEASE PROVIDE A RESUME OF | | INSPECTION EXPERIENCE ON PREVIOUS PROJECT. THE RESUME | | MUST BE ACCOMPANIED BY ALL CERTIFICATES AS SPECIFIED | | HEREIN. THE BUILDING OFFICIAL OR HIS DESIGNEE WILL | | REVIEW THE RESUME. AFTER THE RESUME IS REVIEWED, AN | | INTERVIEW WILL BE SCHEDULED. UNDER NO CIRCUMSTANCES | | WILL AN INSPECTOR BE INTERVIEWED FOR WORK WITHOUT FIRST | | MEETING THE ABOVE CRITERIA. | | | | E) THE CONTRACTOR WILL PRODUCE A JOB SUMMARY OR HISTORY | | FOR THIS TYPE OF CONSTRUCTION. | | | | F) NOTE: FOR DIGITAL PLANS, AFTER PERMIT ISSUANCE, | | PLEASE E-MAIL THE PERMIT LIBRARIAN OF THE PERMIT BEING | | ISSUED, THE PERMIT LIBRARIAN WILL THEN E-MAIL YOU THE | | APPROVED AND BATCH STAMPED PLANS SO YOU MAY PRINT YOUR | | PLANS, TWO SETS OF PLANS WILL NEED TO BE PRINTED IN | | COLOR, (1) FOR THE THRESHOLD INSPECTOR, THE OTHER FOR | | THE MEP INSPECTORS OTHER PLANS YOU WISH TO PRINT MAYBE | | IN BLACK & WHITE. | | | | G) 110.8.4.3 ALL SHORING AND RESHORING PROCEDURES, | | PLANS AND DETAILS SHALL BE SUBMITTED TO THE ENFORCEMENT | | AGENCY FOR RECORDKEEPING. EACH SHORING AND RESHORING | | INSTALLATION SHALL BE SUPERVISED, INSPECTED AND | | CERTIFIED TO BE IN COMPLIANCE WITH THE SHORING | | DOCUMENTS BY THE CONTRACTOR. | | | | H) PLEASE CALL THE CITY OF WEST PALM BEACH'S AUTOMATED | | TELEPHONE INSPECTIONS LINE (561) 805-6700 FOR ALL | | BUILDING INSPECTIONS FOR AUDITING OF JOBSITE | | INSPECTIONS WITHOUT THIS THE PERMIT EXPIRES IN 6 | | MONTHS, ABANDONMENT OF JOB, NO INSPECTION ACTIVITY. | | | | I) 110.8 THRESHOLD BUILDINGS, OPERATING GUIDELINES FOR | | THRESHOLD INSPECTORS #25. ASSURE THAT THE DESIGNER HAS | | REQUIRED ON THE PLANS OR SPECIFICATIONS ONE MATERIAL, | | APPROVED FOR FIRE STOPPING PENETRATIONS, FOR WALLS AND | | CEILINGS. | | | | J) PLEASE CONTACT ME WITH AN EMAIL ADDRESS AND I WILL | | BE HAPPY TO SEND YOU A COPY OF THE CURRENT (OCTOBER | | 2018) GUIDELINES AND POLICIES FOR PROJECTS CONCERNING | | THRESHOLD/SPECIAL INSPECTORS AND RESIDENT INSPECTORS IF | | YOU NEED IT. | | | | 3) SUBMIT A MANAGEMENT OF TRAFFIC (MOT) PLAN, INCLUDING | | PROTECTION OF PEDESTRIANS. FBC 3301 | | | | 4) SHOW HOW THE ADJOINING PROPERTIES WILL BE PROTECTED | | FROM DAMAGE DURING CONSTRUCTION PER FBC 3307. | | | | 5) ON SHEET SP-1, THERE ARE SOME ERRORS. UNDER | | APPLICABLE CODES THE FBC EXISTING BUILDING IS LISTED | | AND THIS IS NEW CONSTRUCTION. PLEASE REMOVE. FBC | | 107.2.1 | | | | 6) ON SHEET SP-1, THE CONSTRUCTION TYPE IS SPECIFIED AS | | IB. IT IS SPECIFIED AS TYPE IIIB ON THE OTHER SHEETS. | | PLEASE CORRECT. FBC 602.1 | | | | 7) ON SHEET ALS.0.1, THE FIRE RESISTANCE RATING IN | | TABLE 602 FOR 10' TO LESS THAN 30' FOR 3B CONSTRUCTION | | SHOULD BE 1 HOUR PER FBC TABLE 602. | | | | 8) THE PRODUCT APPROVALS FOR THE ROOFING MATERIALS IS | | NOT SPECIFED IN THE LIST OF DEFERRED SUBMITTALS ON | | SHEET ALS.0.1. FBC 107.3.4 | | | | 9) ON SHEET ALS.1.1, THE GROUND FLOOR LIFE SAFETY PLAN | | HAS EXIT CORRIDORS 100 AND 103. THESE ARE EXIT | | PASSAGEWAYS PER THE DEFINITION IN CHAPTER 2 OF THE FBC | | AND ARE CONSIDERED EXTENSIONS OF THE EXIT STAIRWAYS. | | PLEASE LABEL THEM ACCORDINGLY AND ENSURE THAT THEY | | COMPLY WITH FBC SECTION 1024. | | | | 10) PLEASE CLARIFY IF THE PARKING SPACES PROVIDED IN | | THE ENCLOSED PARKING GARAGE ARE FOR THE APARTMENTS OR | | THE BUSINESS AND MERCANTILE OCCUPANCIES. FBC 107.2.1 | | | | 11) THERE IS ONE REQUIRED ACCESSIBLE PARKING SPACE | | PROVIDED IN THE ENCLOSED PARKING GARAGE PER FBC | | ACCESSIBILITY TABLE 208.2. FBC ACCESSIBILITY 208.2.4 | | REQUIRES AT LEAST ONE VAN ACCESSIBLE PARKING SPACE FOR | | EVERY SIX OR FRACTION OF SIX PARKING SPACES REQUIRED BY | | 208.2 THAT COMPLIES WITH 502. SHOW THAT THE ONE | | ACCESSIBLE SPACE COMPLIES WITH FBC ACCESSIBILITY 502. | | | | 12) SHOW ON THE PLANS THAT A VERTICAL CLEARANCE OF 98" | | (8' 2") WILL BE PROVIDED FOR THE VAN PARKING SPACE AND | | ACCESS ISLE AND THE VEHICULAR ROUTE SERVING IT. FBC | | ACCESSIBILITY 502.5 | | | | 13) ON SHEET ALS.4.1, THE UNIT IN THE SOUTH EAST CORNER | | IS LABELED KITCHEN. PLEASE CORRECT. FBC 107.2.1 | | | | 14) ON SHEET ALS.4.1, LIFE SAFETY PLAN IS LABELED FIFTH | | FLOOR. IT SHOULD BE LABELED FOURTH AND FIFTH FLOOR. FBC | | 107.2.1 | | | | 15) ON SHEET ALS.4.1, THE THREE UNITS IN THE NORTHEAST | | CORNER HAVE ONLY ONE MEANS OF EGRESS AND MUST PASS BY | | THE ELEVATORS TO GET TO THE EXIT STAIRWAY. FBC 1006 | | | | 16) SHOW COMPLIANCE WITH 3002.4 ELEVATOR CAR TO | | ACCOMMODATE AMBULANCE STRETCHER. ANY BUILDING THAT IS | | MORE THAN THREE STORIES HIGH OR IN WHICH THE VERTICAL | | DISTANCE BETWEEN THE BOTTOM TERMINAL LANDING AND THE | | TOP TERMINAL LANDING EXCEEDS 25 FEET (7620 MM), MUST BE | | CONSTRUCTED TO CONTAIN AT LEAST ONE PASSENGER ELEVATOR | | THAT IS OPERATIONAL FOR BUILDING OCCUPANTS AND FIRE | | DEPARTMENT EMERGENCY ACCESS TO ALL FLOORS. THE ELEVATOR | | CAR SHALL BE OF SUCH A SIZE AND ARRANGEMENT TO | | ACCOMMODATE AN AMBULANCE STRETCHER 24 INCHES BY 76 | | INCHES (610 MM BY 1950 MM) WITH NOT LESS THAN 5-INCH | | (127 MM) RADIUS CORNERS, IN THE HORIZONTAL, OPEN | | POSITION AND SHALL BE IDENTIFIED BY THE INTERNATIONAL | | SYMBOL FOR EMERGENCY MEDICAL SERVICES (STAR OF LIFE). | | THE SYMBOL SHALL BE NOT LESS THAN 3 INCHES (76 MM) IN | | HEIGHT AND SHALL BE PLACED INSIDE ON BOTH SIDES OF THE | | HOISTWAY DOOR FRAME. | | | | 17) SHOW HOW THE SPA POOL WILL COMPLY WITH FBC | | ACCESSIBILITY SECTION 242.2 SWIMMING POOLS. AT LEAST | | TWO ACCESSIBLE MEANS OF ENTRY SHALL BE PROVIDED FOR | | SWIMMING POOLS. ACCESSIBLE MEANS OF ENTRY SHALL BE | | SWIMMING POOL LIFTS COMPLYING WITH 1009.2; SLOPED | | ENTRIES COMPLYING WITH 1009.3; TRANSFER WALLS COMPLYING | | WITH 1009.4; TRANSFER SYSTEMS COMPLYING WITH 1009.5; | | AND POOL STAIRS COMPLYING WITH 1009.6. AT LEAST ONE | | ACCESSIBLE MEANS OF ENTRY PROVIDED SHALL COMPLY WITH | | 1009.2 OR 1009.3. | | EXCEPTIONS: | | 1. WHERE A SWIMMING POOL HAS LESS THAN 300 LINEAR FEET | | (91 M) OF SWIMMING POOL WALL, NO MORE THAN ONE | | ACCESSIBLE MEANS OF ENTRY SHALL BE REQUIRED PROVIDED | | THAT THE ACCESSIBLE MEANS OF ENTRY IS A SWIMMING POOL | | LIFT COMPLYING WITH 1009.2 OR SLOPED ENTRY COMPLYING | | WITH 1009.3. | | 2. WAVE ACTION POOLS, LEISURE RIVERS, SAND BOTTOM | | POOLS, AND OTHER POOLS WHERE USER ACCESS IS LIMITED TO | | ONE AREA SHALL NOT BE REQUIRED TO PROVIDE MORE THAN ONE | | ACCESSIBLE MEANS OF ENTRY PROVIDED THAT THE ACCESSIBLE | | MEANS OF ENTRY IS A SWIMMING POOL LIFT COMPLYING WITH | | 1009.2, A SLOPED ENTRY COMPLYING WITH 1009.3, OR A | | TRANSFER SYSTEM COMPLYING WITH 1009.5. | | 3. CATCH POOLS SHALL NOT BE REQUIRED TO PROVIDE AN | | ACCESSIBLE MEANS OF ENTRY PROVIDED THAT THE CATCH POOL | | EDGE IS ON AN ACCESSIBLE ROUTE. | | | | COMMUNITY POOLS THAT ARE ASSOCIATED WITH A PRIVATE | | RESIDENTIAL COMMUNITY THAT DO NOT RECEIVE GOVERNMENTAL | | FINANCIAL ASSISTANCE OR SPONSORSHIP AND ARE LIMITED TO | | THE EXCLUSIVE OF RESIDENTS AND THEIR GUESTS ARE NOT | | COVERED BY THE ADA ACCESSIBILITY REQUIREMENTS, | | INCLUDING PROVISIONS FOR POOL LIFTS OR SLOPED ENTRIES. | | IF A SWIMMING POOL LOCATED IN A RESIDENTIAL COMMUNITY | | IS MADE AVAILABLE TO THE PUBLIC FOR RENTAL OR USE IT IS | | REQUIRED TO COMPLY WITH TITLE II OF THE ADA. SPECIFY ON | | THE PLANS THE FORMER OR SHOW COMPLIANCE WITH THE LATTER | | STATEMENTS. SEE DECLARATORY STATEMENT, DS 2013-011. | | | | 18) SUBMIT A DETAILED COST BREAKDOWN FOR THIS PROJECT. | | THIS WILL PREVENT US FROM CHARGING YOU DOUBLE FOR ITEMS | | THAT REQUIRE SEPARATE PERMITS. BUILDING PERMIT | | VALUATION. FOR PERMITTING PURPOSES, VALUATION OF FBC | | 109.3 BUILDINGS AND SYSTEMS SHALL BE TOTAL REPLACEMENT | | VALUE TO INCLUDE STRUCTURAL, ELECTRIC, PLUMBING, | | MECHANICAL, INTERIOR FINISH, RELATIVE SITE WORK, | | ARCHITECTURAL AND DESIGN FEES, MARKETING COSTS, | | OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE. | | VALUATION REFERENCES MAY INCLUDE THE LATEST PUBLISHED | | DATA OF NATIONAL CONSTRUCTION COST ANALYSIS SERVICES | | (MARSHALL-SWIFT, MEANS, ETC.), AS PUBLISHED BY | | INTERNATIONAL CODE CONGRESS. FINAL BUILDING PERMIT | | VALUATION SHALL BE SET BY THE BUILDING OFFICIAL. | | | | 19) A. DEFERRED SUBMITTALS REQUESTED BY ARCHITECT, SEE | | FOLLOWING LIST (MAY NOT BE A COMPLETE LIST); DOCUMENTS | | SHOWING COMPLIANCE ARE TO BE REVIEWED BY DESIGNER OF | | RECORD PRIOR TO SUBMITTAL (ARCHITECT OR ENGINEER FOR | | PRODUCT APPROVALS AND OTHER SPECIFICATION DOCUMENTS, | | STRUCTURAL ENGINEER OF RECORD APPROVAL AND REVIEW IS | | REQUIRED FOR DELEGATED ENGINEERING). SUBMITTAL, REVIEW | | AND APPROVAL ARE REQUIRED PRIOR TO INSTALLATION. | | | | COMPONENT & CLADDING PRODUCT APPROVALS (COMPLY WITH | | PRESSURES SHOWN ON SHEET S0.0.5) | | | | COMPONENT & CLADDING PRODUCT APPROVALS REVIEWED BY | | DESIGNER OF RECORD ARE TO BE SUBMITTED TO THE BUILDING | | DIVISION, REVIEWED AND ISSUED PRIOR TO INSTALLATION. | | CONFIRM COMPLIANCE WITH PRESSURES SHOWN ON SHEET S0.0.5 | | PRIOR TO SUBMITTAL. IF PRODUCT APPROVAL OFFERS OPTIONS, | | INDICATE OPTION PROPOSED, ESPECIALLY IF NOT ALL OPTIONS | | COMPLY WITH MINIMUM DESIGN PRESSURES. | | | | B. SEPARATE PERMITS (APPLICATIONS, PLANS, AND FEES) ARE | | REQUIRED FOR: | | LIGHT POLES/SITE LIGHTING | | FIRE ALARM | | FIRE SPRINKLER | | LOW VOLTAGE | | ACCESS | | LANDSCAPING | | IRRIGATION | | PARKING LOT | | SWIMMING POOLS AND SPAS | | GENERATORS | | ALL OTHER ITEMS OTHER THAN BMEP | | | | C. AIPP COMPLIANCE REQUIRED; VERIFICATION REQUIRED | | PRIOR TO C.O. | | | | D. SHORING/RESHORE ENGINEERING IS REQUIRED TO BE | | SUBMITTED TO THE BUILDING DIVISION FOR REVIEW. THE | | ENGINEERING IS TO BE SUBMITTED, REVIEWED AND ISSUED | | PRIOR TO CONCRETE POUR. | | | | E. A CONSTRUCTION GUARD RAIL ENGINEERED DETAIL IS | | REQUIRED TO BE PROVIDED PRIOR TO INSTALLATION. | | | | F. CONSTRUCTION HOURS - 7AM TO 7PM MON-FRI, 8AM TO 8PM | | SAT-SUN | | | | 20) THE WEST ELEVATION ON SHEET A3.0.2 APPEARS TO SHOW | | WINDOWS WHERE OPENINGS ARE NOT PERMITTED PER FBC | | 705.8.1. PLEASE CLARIFY. | | | | 21) SHOW THE CALCULATIONS FOR THE ALLOWABLE AREA OF | | OPENINGS FOR EACH STORY OF THE SOUTH ELEVATION AS | | REQUIRED BY FBC 705.8.1. SHOW THE DISTANCE FROM THE | | WEST WALL TO THE CENTER OF THE ALLY ON THE PLANS. | | | | 22) PROVIDE A FLOOR AREA BREAKDOWN BY OCCUPANCY TYPE | | FOR EACH FLOOR OF THE PROPOSED BUILDING. FBC 107.2.1 & | | 503.1 | | | | 23) PLEASE SUBMIT A RESPONSE LETTER INDICATING HOW EACH | | OF THE REVIEW COMMENTS HAS BEEN ADDRESSED. THE | | RESPONSES TO THESE COMMENTS MAY RESULT IN ADDITIONAL | | COMMENTS. | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2023-06-02 |
|
|
Cont ID |
|
Sent By |
mpeterso |
Date |
2023-06-02 |
Time |
14:27 |
Rev Time |
0.00 |
Received By |
mpeterso |
Date |
2023-06-02 |
Time |
09:43 |
Sent To |
|
|
Notes |
2023-06-02 14:31:19 | ELECTRIC REVIEW FAILED | | | | 1) GENERATOR IS STILL DETAILED ON GROUND FLOOR PLAN | | ALTHOUGH IT WAS REMOVED. PLEASE REMOVE ALL REFERENCES | | TO GENERATOR. FBC 107.2 | | | | 2) RISER DOES NOT DETAIL PANEL P, RISER INDICATES PANEL | | P WITH A MLO SYMBOL, RISER INDICATES PANEL P ON 5TH | | FLOOR, HOWEVER, PANEL P IS SHOWN TO BE LOCATED POOL | | EQUIPMENT RM 242, PANEL P OCP IS NOT SHOWN ON THE RISER | | AS BEING IN THE MDP PANEL, PANEL OPG IS DETAILED IN MDP | | PANEL SCHEDULE WITH 600 OCP OTHER SCHEDULES AND RISER | | INDICATE 400 AMP. NEC 215.5 | | | | 3) PLEASE CHANGE THE NAME IN THE SUBMITTAL FOR SHEET | | E7.03 FROM FIRE ALARM RISER DIAGRAM TO BUILDING | | ELECTRIC LOAD CALCULATIONS IN THE SUBMITTAL. | | | | 4) PLEASE PROVIDE PANEL SCHEDULES FOR PANELS EP4, WP2 | | ANDWP4. FBC 107.2 | | | | 5) COMPLETE MOTOR/EQUIPMENT CIRCUIT SCHEDULE TO INCLUDE | | PANEL ORIGIN FOR EQUIPMENT SHOWN. PLEASE REMOVE FP AS | | IT DOES NOT EXIST. FBC 107.2 | | | | 6) PLEASE DETAIL THAT EV CHARGING STATIONS PROVIDE ONE | | EV CHARGING STATION STRIPED AS AN ACCESSIBLE PARKING | | SPACE. ONE SUCH SPACE IS REQUIRED FOR EVERY 25 EV | | CHARGING STATIONS PROVIDED. SECTION 208 OF FLORIDA | | ACCESSIBILITY CODE REQUIRES THAT EACH TYPE OF PARKING | | FACILITY (SUCH AS COVERED PARKING, PARKING WITH | | CHARGING STATION, ETC.) MUST ALSO INCLUDE ACCESSIBLE | | PARKING, AND THE NUMBER OF ACCESSIBLE SPACES REQUIRED | | IS DETERMINED BY HOW MANY REGULAR (NON-ACCESSIBLE) | | PARKING SPACES OF THAT TYPE ARE PROVIDED. IF THERE ARE | | BETWEEN 1 - 25 PARKING SPACES PROVIDED WITH CHARGING | | STATIONS (I.E. PARKING FACILITY), THEN 1 SUCH SPACE | | MUST BE ACCESSIBLE | | | | 7) APARTMENT ELECTRIC FLOOR PLANS AND PANEL SCHEDULES | | DO NOT DETAIL THE REQUIRED 2 SMALL APPLIANCE CIRCUITS | | IN ACCORDANCE WITH NEC 21O.11(C)(1) | | | | 8) PLEASE LOCATE POOL ALL POOL EQUIPMENT, PUMP, HEATER, | | ETC. ON ELECTRIC FLOOR PLANS. FBC 107.2 | | | | 9) PLEASE INDICATE DISTANCE OF RECEPTACLE NEAR POOL AS | | BEING COMPLIANT WITH NEC 680.22(A)(1) | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. | | | | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | BUILDING CODE 2020 7TH ED. | | FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020 | | 7TH EDITION | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | 7TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION | | NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | V/R, | | | | MICHAEL PETERSON | | ELECTRICAL PLANS EXAMINER | | [email protected] | | 561-805-6746 | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2023-02-13 |
|
|
Cont ID |
|
Sent By |
mpeterso |
Date |
2023-02-13 |
Time |
12:21 |
Rev Time |
0.00 |
Received By |
mpeterso |
Date |
2023-02-08 |
Time |
07:57 |
Sent To |
|
|
Notes |
2023-02-13 12:25:08 | ELECTRIC REVIEW FAILED | | | | 1) THERE ARE MANY CONFLICTS WITH PANEL SCHEDULE | | DESCRIPTION TITLE BLOCKS. EXAMPLES ARE, SCHEDULES | | INCORRECTLY DETAILING, MLO, MB, BUS SIZE. IN ADDITION, | | MANY SCHEDULES OR RISER DETAIL INCORRECT SUB PANEL | | BREAKER SIZES WHICH ARE IN CONFLICT WITH RISER DIAGRAM. | | PLEASE PROVIDE CORRECTIONS TO ALL PANEL SCHEDULES AND | | RISER AS APPLICABLE. | | | | FBC 107.2, CONSTRUCTION DOCUMENTS SHALL BE OF | | SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE AND | | EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT IT | | WILL CONFORM TO THE PROVISIONS OF THIS CODE AND | | RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS | | DETERMINED BY THE BUILDING OFFICIAL. | | | | NEC 215.5 DIAGRAMS OF FEEDERS. IF REQUIRED BY THE | | AUTHORITY HAVING | | JURISDICTION, A DIAGRAM SHOWING FEEDER DETAILS SHALL BE | | PROVIDED | | PRIOR TO THE INSTALLATION OF THE FEEDERS. | | | | 2) PLEASE DETAIL CONDUCTOR, AND CORRECT OVERCURRENT | | PROTECTION SIZE FOR PANEL OPG BOTH ON RISER AND PANEL | | SCHEDULE. FBC 107.2 AND NEC 215.5 | | | | 3) PLEASE DETAIL OVERCURRENT PROTECTION TO PANEL OP5 | | FROM MPD-1 ON RISER DIAGRAM. FBC 107.2 AND NEC 215.5 | | | | 4) PLEASE DETAIL GENERATOR CONTROL CONDUIT TO FIRE PUMP | | CONTROLLER, EITHER BY NOTE OR PLANS TO BE INSTALLED AS | | PER NEC 695.14 GENERATOR CONTROL WIRING METHODS, | | INTEGRITY AND FIRE RATING | | | | 5) PLEASE DETAIL IN RISER DIAGRAM COMPLIANCE WITH | | EMERGENCY SYSTEMS, NEC 700.3 (F) TEMPORARY SOURCE OF | | POWER FOR MAINTENANCE OR REPAIR OF THE ALTERNATE SOURCE | | OF POWER. | | | | 6) PLEASE DETAIL GENERATOR SUPPLIED NATURAL GAS TO BE | | SUPPLIED BY ALTERNATE FUEL SOURCE AS REQUIRED PER NEC | | 700.12 (B)(3) DUAL SUPPLIES. PRIME MOVERS SHALL NOT BE | | SOLELY DEPENDENT ON A PUBLIC UTILITY GAS SYSTEM FOR | | THEIR FUEL SUPPLY OR MUNICIPAL WATER SUPPLY FOR THEIR | | COOLING SYSTEMS. MEANS SHALL BE PROVIDED FOR | | AUTOMATICALLY TRANSFERRING FROM ONE FUEL SUPPLY TO | | ANOTHER WHERE DUAL FUEL SUPPLIES ARE USED. | | | | 7) PLEASE DETAIL ALL PANIC HARDWARE FOR MAIN ELECTRIC | | ROOM DOORS AS REQUIRED OF NEC 110.26(C)(3) | | | | 8) PLEASE PROVIDE BY NOTE COMPLIANCE WITH NEC 408.4(B) | | FIELD IDENTIFICATION REQUIRED FOR SOURCE OF SUPPLY FOR | | SWITCH AND PANEL BOARDS | | | | 9) PLEASE PROVIDE AN ENTIRE BUILDING ELECTRIC LOAD | | CALCULATION. | | | | NEC 215.5 AND NEC 215.2 FEEDER CONDUCTORS SHALL HAVE AN | | AMPACITY NOT LESS THAN REQUIRED TO SUPPLY THE LOAD | | | | 10) PLEASE PROVIDE INFORMATION ON THE USE OF GROUND | | FLOOR ROOM 102 LABELED METER ROOM. FBC 107.2 | | | | 11) PLEASE CALL OUT ALL GROUNDING ELECTRODE CONDUCTOR | | SIZES, NOT CODE ARTICLES, AS REQUIRED BY NEC 250.66 | | | | 12) MANY APARTMENT PANEL SCHEDULES ARE MISSING ELECTRIC | | LOADS, IE WATER HEATERS AND AIR CONDITIONING. FBC 107.2 | | | | 13) PLEASE DETAIL ALL RECEPTACLES IN COMMON AREAS, AS | | APPLICABLE AND REQUIRED BY NEC 210.8 (B)(2)(KITCHENS) | | AS GFI PROTECTED | | | | 14) MANY CIRCUITS IN APARTMENT PANEL SCHEDULES ARE NOT | | DETAILED AS ARC FAULT PROTECTED, AS REQUIRED BY NEC. | | 210.13 PLEASE CORRECT AS APPLICABLE | | | | 15) PLEASE CORRECT LABELING ON SHEET E-400, OF ROOM | | DETAILED AS DOMESTIC AN FIRE PUMP ROOM AS APPLICABLE. | | FBC 107.2 | | | | 16) PLEASE PROVIDE A NOTE STATING, LIGHTNING | | PROTECTION, VOICE, DATA, SECURITY, AUDIO, VIDEO, FIRE | | ALARM, ACCESS CONTROL, ENERGY MANAGEMENT, GENERATOR, | | SIGN, SITE LIGHTING, POOL AND BDA WIRING REQUIRE | | SEPARATE PERMITS | | | | 17) PLEASE DETAIL ALL SMOKE/CARBON ALARMS IN ALL UNITS | | AS REQUIRED BY FBC R314 AND R315 | | | | 18) PLEASE DETAIL FAN TEF ON ROOF POWER PLAN. FBC 107.2 | | | | 19) PLEASE DETAIL (2) ELEVATOR CONTROLLER ON ROOF POWER | | PLAN. FBC 107.2 | | | | 20) PLEASE DETAIL GFI PROTECTION OF APPROPRIATE LOADS | | IN PANEL OF, IE DRINKING FOUNTAIN, KITCHEN AREAS | | | | 21) PLEASE DETAIL ROOF LIGHTS ON ROOF POWER PLAN. FBC | | 107.2 | | | | 22) PLEASE PROVIDE ALL ELECTRIC ROOM DETAILS AS ALL ARE | | NOT THE SAME. PLEASE INCLUDE ALL EQUIPMENT AND | | DIMENSIONS TO ENSURE COMPLIANCE WITH WORKING CLEARANCES | | AS REQUIRED BY NEC 110.26 | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. | | | | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | BUILDING CODE 2020 7TH ED. | | FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020 | | 7TH EDITION | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | 7TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION | | NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | V/R, | | | | MICHAEL PETERSON | | ELECTRICAL PLANS EXAMINER | | [email protected] | | 561-805-6746 | | |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
2 |
Status |
F |
Date |
2023-05-19 |
|
|
Cont ID |
|
Sent By |
lquinone |
Date |
2023-05-19 |
Time |
15:20 |
Rev Time |
0.00 |
Received By |
lquinone |
Date |
2023-05-19 |
Time |
15:20 |
Sent To |
|
|
Notes |
2023-05-19 15:20:43 | UNDER FORMAL ENG SUBMITTAL REVIEW. |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
1 |
Status |
F |
Date |
2023-02-13 |
|
|
Cont ID |
|
Sent By |
rrossano |
Date |
2023-02-13 |
Time |
|
Rev Time |
|
Received By |
rrossano |
Date |
2023-02-13 |
Time |
|
Sent To |
|
|
Notes |
2023-02-13 12:12:32 | UNDER FORMAL ENGINEERING SUBMITTAL REVIEW. | | | | THANKS, | | RICK ROSSANO, SENIOR PROJECT COORD., WPB ENG. SERVICES | | DEPT., 561-494-1098, FAX: 561-494-1116 [email protected] |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2023-05-19 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2023-05-19 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2023-05-15 |
Time |
11:52 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2023-02-10 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2023-02-10 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2023-02-08 |
Time |
10:02 |
Sent To |
|
|
Notes |
2023-02-09 10:55:09 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | 1) SHEET C 3 - THERE IS AN INDICATION OF FIRE LINE | | UNDERGROUND, INCLUDING A DDCV. | | | | ALL FIRE LINE UNDEERGROUND WORK SHALL BE INSTALLED, | | INSPECTED & TESTED UNDER SEPARATE BUILDING PERMIT(NOT | | JUST AN ENGINEERING PERMIT) WITH SHOP DRAWINGS AND | | MANUFACTURES SPECIFICATION SHEETS AND COMPLY WITH NFPA | | 24 & MANUFACTURE SPECIFICATIONS. | | | | PLEASE RVIEW, ENSURE COMPLIANCE AND PROVIDE A NOTE OF | | ACKNOWLEDGMENT. | | | | | | 2) SHEET ALS 1.1 & EL 1.00 - THE ALS PLAN INDICATES AN | | EXIT SIGN OVER THE STAIR # 2 DOOR AND RECEPTION 107 | | DOUBLE DOORS; HOWEVER THE EL PLAN DOES NOT. | | | | PER NFPA 101 CH. MEANS OF EGRESS | | | | 7.10.1.2 EXITS. | | 7.10.1.2.1* EXITS, OTHER THAN MAIN EXTERIOR EXIT DOORS | | THAT OBVIOUSLY | | AND CLEARLY ARE IDENTIFIABLE AS EXITS, SHALL BE MARKED | | BY AN APPROVED | | SIGN THAT IS READILY VISIBLE FROM ANY DIRECTION OF EXIT | | ACCESS | | | | PLEASE REVIEW AND CORRECT PER THE CODE REQUIRMENTS. | | | | | | 3) SHEET EL 1.00 - THE BIKE STORAGE ROOM HAS | | INDICATIONS OF EXIT SIGNS OVER BOTH DOORS; HOWEVER, ONE | | DOOR LEADS INTO THE TRASH ROOM. | | | | PER NFPA 101 CH 30, NEW APARTMENT OCCUPANCIES | | | | 30.2.5 ARRANGEMENT OF MEANS OF EGRESS. | | 30.2.5.1 ACCESS TO ALL REQUIRED EXITS SHALL BE IN | | ACCORDANCE WITH SEC TION 7.5, AS MODIFIED BY 30.2.5.2. | | | | 7.5.1.6 EXIT ACCESS FROM ROOMS OR SPACES SHALL BE | | PERMITTED TO BE | | THROUGH ADJOINING OR INTERVENING ROOMS OR AREAS, | | PROVIDED THAT SUCH | | ROOMS OR AREAS ARE ACCESSORY TO THE AREA SERVED. | | FOYERS, LOBBIES, AND | | RECEPTION ROOMS CONSTRUCTED AS REQUIRED FOR CORRIDORS | | SHALL NOT BE CON STRUED AS INTERVENING ROOMS. EXIT | | ACCESS SHALL BE ARRANGED SO THAT IT IS | | NOT NECESSARY TO PASS THROUGH ANY AREA IDENTIFIED UNDER | | PROTECTION FROM | | HAZARDS IN CHAPTERS 11 THROUGH 43 | | | | AN ADDITIONAL EXIT SIGN MAY BE NEEDED SO IT IS SEEN | | FROM THE ENTIRE LENGTH OF THE BIKE STORAGE ROOM ( OR | | THAT EXIT SIGN CAN BE RELOCATED SO IT IS SEEN WITH A | | CHEVRON TO THE DOOR) | | | | PLEASE REVIEW AND CORRECT. | | | | | | 4) SHEETS EL 1.01 THROUGH EL 1.04 - THERE DOES NOT | | APPEAR TO BE INDICATIONS OF EXIT SIGNAGE AND EMERGENCY | | LIGHTING WITHIN THE TWO TENANT STORGAGE ROOMS ON EACH | | FLOOR. | | | | PER NFPA 101 CH 30 & CH 7 | | | | 30.2.9 EMERGENCY LIGHTING. EMERGENCY LIGHTING IN | | ACCORDANCE WITH | | SECTION 7.9 SHALL BE PROVIDED IN ALL BUILDINGS FOUR OR | | MORE STORIES IN | | HEIGHT, OR WITH MORE THAN 12 DWELLING UNITS, UNLESS | | EVERY DWELLING UNIT | | HAS A DIRECT EXIT TO THE OUTSIDE OF THE BUILDING AT THE | | FINISHED GROUND LEVEL. | | 30.2.10 MARKING OF MEANS OF EGRESS. MEANS OF EGRESS | | SHALL HAVE | | SIGNS IN ACCORDANCE WITH SECTION 7.10 IN ALL BUILDINGS | | REQUIRING MORE | | THAN ONE EXIT. | | | | PLEASE REVIEW AND CORRECT. | | | | | | 5) SHEET ALS 3.1 & EL 1.02 - THERE ARE INDICATIONS OF 2 | | EXITS FROM THE TERRACE ARE, HOWEVER, THERE APPEARS TO | | BE A GATE SEPARATING TWO AREAS. | | | | THERE IS NO IINDICATIONS OF THE LOCK/LATCH OF THIS GATE | | THAT MEETS THE REQUIREMENTS OF NFPA 101 CH 7. | | | | 7.2.1.5.10* A LATCH OR OTHER FASTENING DEVICE ON A DOOR | | LEAF SHALL BE | | PROVIDED WITH A RELEASING DEVICE THAT HAS AN OBVIOUS | | METHOD OF OPERATION | | AND THAT IS READILY OPERATED UNDER ALL LIGHTING | | CONDITIONS. | | | | 7.2.1.5.10.1 THE RELEASING MECHANISM FOR ANY LATCH | | SHALL BE LOCATED AS | | FOLLOWS: | | (1) NOT LESS THAN 34 IN. (865 MM) ABOVE THE FINISHED | | FLOOR FOR OTHER | | THAN EXISTING INSTALLATIONS | | (2) NOT MORE THAN 48 IN. (1220 MM) ABOVE THE FINISHED | | FLOOR | | | | PLEASE REVIEW AND PROVIDE FOR THE REQUIREMENTS. | | | | | | | | | | 5A) SHEET ALS 3.1 & EL 1.02 - THERE IS NO INDICATION OF | | AN EXIT SIGN OVER THIS GATE ON EITHER SIDE. | | | | PLEASE REVIEW AND PROVIDE FOR THE REQUIREMENTS OF | | PROVIDE A NARRATIVE AND CODE REFERENCES FOR EIXT SIGN | | EXCLUSION IN THIS AREA. | | | | | | | | 6) LIFE SAFETY SHEETS - THERE IS NO INDICATIONS OF | | AREAS OF REFUGE. | | | | THERE APPEARS TO BE LARGE STAIRWAY LANDINGS IN STAIRWAY | | 2. IS THIS PROPOSED TO BE THE AREA OF REFUGE? | | | | PLEASE REVIEW AND PROVIDE CLARIFICATIONS. | | | | | | | | 6A) LIFE SAFETY SHEETS - THERE ARE NO INDICATIONS OF | | AREA OF REFUGE INDICATORS/EQUIPMENT. | | | | PER # 6 ABOVE PLEASE, IF APPLICABLE, PROVIDE FOR THE | | REQUIREMENTS OF NFPA 101 CH 7, 7.2.12 AREAS OF REFUGE. | | | | PROVIDE JUSTIFICATION WITH DETAILED NARRATIVE AND CODE | | REFERENCES IF NOT APPLICABLE. | | | | | | | | 7) FIRE PROECTECTION SHEETS - THERE IS AN INDICATION OF | | AN ELECTRIC FIRE PUMP. FOR CLARIFICATION PURPOSES | | PLEASE PROVIDE THE BACK UP POWER SOURCE AND FUEL SOURCE | | OF THE BACK UP POWER SOURCE PER NFPA 20 & 70. | | | | NFPA 20 | | 9.3 ALTERNATE POWER. 9.3.1 EXCEPT FOR AN ARRANGEMENT | | DESCRIBED IN 9.3.3, AT LEAST ONE ALTERNATE SOURCE OF | | POWER SHALL BE PROVIDED WHERE THE HEIGHT OF THE | | STRUCTURE IS BEYOND THE PUMPING CAPACITY OF THE FIRE | | DEPARTMENT APPARATUS. 9.3.2* OTHER SOURCES. EXCEPT FOR | | AN ARRANGEMENT DESCRIBED IN 9.3.3, AT LEAST ONE | | ALTERNATE SOURCE OF POWER SHALL BE PROVIDED WHERE THE | | NORMAL SOURCE IS NOT RELIABLE. 9.3.3 AN ALTERNATE | | SOURCE OF POWER FOR THE PRIMARY FIRE PUMP SHALL NOT BE | | REQUIRED WHERE A BACKUP ENGINE-DRIVEN FIRE PUMP, BACKUP | | STEAM TURBINE-DRIVEN FIRE PUMP, OR BACKUP ELECTRIC | | MOTOR???DRIVEN FIRE PUMP WITH INDEPENDENT POWER SOURCE | | MEETING 9.2.2 IS INSTALLED IN ACCORDANCE WITH THIS | | STANDARD. 9.3.4 WHERE PROVIDED, THE ALTERNATE SOURCE OF | | POWER SHALL BE SUPPLIED FROM ONE OF THE FOLLOWING | | SOURCES: (1) A GENERATOR INSTALLED IN ACCORDANCE WITH | | SECTION 9.6 (2) ONE OF THE SOURCES IDENTIFIED IN | | 9.2.2(1), 9.2.2(2), 9.2.2(3), OR 9.2.2(5) WHERE THE | | POWER IS PROVIDED INDEPENDENT OF THE NORMAL SOURCE OF | | POWER 9.3.5 WHERE PROVIDED, THE ALTERNATE SUPPLY SHALL | | BE ARRANGED SO THAT THE POWER TO THE FIRE PUMP IS NOT | | DISRUPTED WHEN OVERHEAD LINES ARE DE-ENERGIZED FOR FIRE | | DEPARTMENT OPERATIONS | | | | NFPA 70 | | ARTICLE 695 FIRE PUMPS | | (2) ON-SITE POWER PRODUCTION FACILITY. A FIRE PUMP | | SHALL BE PERMITTED TO BE SUPPLIED BY AN ON-SITE POWER | | PRODUCTION FACILITY. THE SOURCE FACILITY SHALL BE | | LOCATED AND PROTECTED TO MINIMIZE THE POSSIBILITY OF | | DAMAGE BY FIRE. | | (3) DEDICATED FEEDER. A DEDICATED FEEDER SHALL BE | | PERMIT TED WHERE IT IS DERIVED FROM A SERVICE | | CONNECTION AS DESCRIBED IN 695.3(A)(1). | | (B) MULTIPLE SOURCES. IF RELIABLE POWER CANNOT BE | | OBTAINED FROM A SOURCE DESCRIBED IN 695.3(A), POWER | | SHALL BE SUPPLIED BY ONE OF THE FOLLOWING: | | (1) INDIVIDUAL SOURCES. AN APPROVED COMBINATION OF TWO | | OR MORE OF THE SOURCES FROM 695.3(A). (2) INDIVIDUAL | | SOURCE AND ON-SITE STANDBY GENERATOR. AN APPROVED | | COMBINATION OF ONE OR MORE OF THE SOURCES IN 695.3(A) | | AND AN ON-SITE STANDBY GENERATOR COMPLYING WITH | | 695.3(D). | | (D) ON-SITE STANDBY GENERATOR AS ALTERNATE SOURCE. AN | | ON-SITE STANDBY GENERATOR(S) USED AS AN ALTERNATE | | SOURCE OF POWER SHALL COMPLY WITH (D)(1) THROUGH | | (D)(3). | | (1) CAPACITY. THE GENERATOR SHALL HAVE SUFFICIENT | | CAPACITY TO ALLOW NORMAL STARTING AND RUNNING OF THE | | MOTOR(S) DRIVING THE FIRE PUMP(S) WHILE SUPPLYING ALL | | OTHER SIMULTANEOUSLY OPERATED LOAD(S) | | | | PLEASE REVIEW AND PROVIDE SPECIFIC DETAILS IN | | COMPLIANCE. | | | | | | | | | | 8) SHEET A 2.0.1 - THERE APPEARS TO BE AN INDICATION OF | | A ROOF ACCESS HATCH; HOWEVER, THERE ARE NO INDICATIONS | | OF THE SIZE/DIMENSIONS OF THE HATCH, NOR A LADDER/STAIR | | PULL DOWN, FOR ACCESS PURPOSES. | | | | PLEASE REVIEW AND PROVIDE DETAILS THAT ARE IN | | COMPLIANCE WITH THE REQUIREMENTS OF THE CODE. | | | | | | | | 9) SHEET ALS 2.1 - THERE IS AN INDICATION OF DOUBLE | | DOORS FROM THE CLUBROOM OPENING OUT INTO THE COURTYARD | | THAT APPEAR TO RESTRICT THE EGRESS WIDTH AT THE CLUMN | | ON THE RIGHT SIDE AND THE BRICK WALL ON THE LEFT SIDE. | | | | PER NFPA 101 CHAPTER 7, MEANS OF EGRESS | | 7.2.1.4.3 DOOR LEAF ENCROACHMENT | | 7.2.1.4.3.1 DURING ITS SWING, ANY DOOR LEAF IN A MEANS | | OF EGRESS SHALL | | LEAVE NOT LESS THAN ONE-HALF OF THE REQUIRED WIDTH OF | | AN AISLE, A CORRIDOR, | | A PASSAGEWAY, OR A LANDING UNOBSTRUCTED, UNLESS BOTH OF | | THE FOLLOWING | | CONDITIONS ARE MET: | | (1) THE DOOR OPENING PROVIDES ACCESS TO A STAIR IN AN | | EXISTING | | BUILDING. | | (2) THE DOOR OPENING MEETS THE REQUIREMENT OF | | 7.2.1.4.3.2. | | 7.2.1.4.3.2 WHEN FULLY OPEN, ANY DOOR LEAF IN A MEANS | | OF EGRESS SHALL | | NOT PROJECT MORE THAN 7 IN. (180 MM) INTO THE REQUIRED | | WIDTH OF AN AISLE, | | A CORRIDOR, A PASSAGEWAY, OR A LANDING, UNLESS THE DOOR | | LEAF IS EQUIPPED | | WITH AN APPROVED SELF-CLOSING DEVICE AND IS NOT | | REQUIRED BY THE PROVISIONS | | OF 7.2.1.4.2 TO SWING IN THE DIRECTION OF EGRESS | | TRAVEL. | | | | PLEASE REVIEW AND ENSURE THAT THE DIMENSION MEETS THE | | MINIUMUM WIDTH REQUIREMENT OF THE EGRESS PATH. | | | | | | | | 10) ELECTRICAL SHEETS - THERE ARE NO INDICATIONS FOUND | | OF SMOKE ALARMS WITHIN THE UNITS. | | | | PER NFPA 101 CH 30 | | | | 30.3.4.5* SMOKE ALARMS. SMOKE ALARMS SHALL BE INSTALLED | | IN ACCORDANCE WITH 9.6.2.10 IN EVERY SLEEPING AREA, | | OUTSIDE EVERY SLEEPING AREA | | IN THE IMMEDIATE VICINITY OF THE BEDROOMS, AND ON ALL | | LEVELS OF THE DWELLING UNIT, INCLUDING BASEMENTS. | | | | PLEASE REVIEW, ENSURE COMPLIANCE, AND CORRECT. | | | | | | 11) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | ABOVE. | | | | | | 12) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | RE-SUBMITTAL OF THE ABOVE. DELINEATE | | | | | | PETER LEDUC | | FIRE MARSHAL | | 561-804-4709 | | [email protected] | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
2 |
Status |
P |
Date |
2023-05-12 |
|
|
Cont ID |
|
Sent By |
rwbrown |
Date |
2023-05-12 |
Time |
10:19 |
Rev Time |
0.00 |
Received By |
rwbrown |
Date |
2023-05-12 |
Time |
10:19 |
Sent To |
|
|
Notes |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
F |
Date |
2023-02-14 |
|
|
Cont ID |
|
Sent By |
rwbrown |
Date |
2023-02-14 |
Time |
14:05 |
Rev Time |
0.00 |
Received By |
rwbrown |
Date |
2023-02-14 |
Time |
13:59 |
Sent To |
|
|
Notes |
2023-02-14 14:05:05 | 1ST GAS REVIEW | | | | THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED | | BY RYAN BROWN WITH THE FOLLOWING COMMENTS. | | | | 1. 2017 WPB AMENDS 107.3.5.1.5 - INDICATE THE INTENDED | | GAS SUPPLY PRESSURE FROM FPU. | | | | 2. 2017 WPB AMENDS 107.3.5.1.5 - INDICATE THE INTENDED | | GAS LINE MATERIAL | | | | 3. 2017 WPB AMENDS 107.3.5.1.5 - SHOW A DETAIL FOR THE | | GAS ISOMETRIC WITH PIPE SIZES AND PRESSURES. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM. | | | | | | RYAN W. BROWN | | CHIEF PLUMBING INSPECTOR | | OFFICE: 561-805-6692 | | CELL: 561-517-4293 | | EMAIL: [email protected] | | | | | | V7 FPC - 2020 FLORIDA PLUMBING CODE | | V7 FGC - 2020 FLORIDA FUEL GAS | | V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE | | V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE | | V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE | | V7 FEC - 2020 FLORIDA ENERGY CONSERVATION | | 2021 F.S. - 2021 FLORIDA STATUTES | | 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE | | 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE | | FBC CHAPTER 1 | | |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
P |
Date |
2023-03-23 |
|
|
Cont ID |
|
Sent By |
amhamilt |
Date |
2023-03-23 |
Time |
09:51 |
Rev Time |
0.00 |
Received By |
amhamilt |
Date |
2023-03-23 |
Time |
09:51 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2023-06-26 |
|
|
Cont ID |
|
Sent By |
aoliver |
Date |
2023-06-26 |
Time |
07:29 |
Rev Time |
0.00 |
Received By |
aoliver |
Date |
2023-05-10 |
Time |
16:49 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2023-03-30 |
|
|
Cont ID |
|
Sent By |
aoliver |
Date |
2023-03-30 |
Time |
12:39 |
Rev Time |
0.00 |
Received By |
aoliver |
Date |
2023-02-07 |
Time |
07:31 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2023-03-08 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2023-03-08 |
Time |
16:03 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2023-03-08 |
Time |
16:03 |
Sent To |
|
|
Notes |
2023-03-08 16:04:27 | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON | | APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE RECEIPT TO | | YOUR PROJECT OR EMAIL IT TO [email protected] . |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2023-06-15 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2023-06-15 |
Time |
08:34 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2023-06-14 |
Time |
13:19 |
Sent To |
|
|
Notes |
2023-06-15 08:34:23 | PLAN DENIED | | 1) PAGE M1.00 REFER TO SECTION 503.1 EXHAUST DISCHARGE. | | EF-2 IS DISCHARGEING INTO THE GARAGE. | | 2) PAGE M1.01 WHAT IS THE 10X8 DUCT IN THE CORRIDOR? | | IS THAT THE AIR HANDLER OR SOME KIND OF EXHAUST. THE | | LEGEND THE SIMBOL SAYS EXHAUST. SECTION 107 FBC | | 3) REFER TO SECTION 402.2 VENTILATION AREA REQUIRED. | | 2020FBC (M) FOR LIVE IN UNITS. | | 4) PAGE M6.00 CAN'T READ THE NATURL VEMTILATION | | CALCULATIONS FOR THE LIVE IN UNITS SECTION 107 FBC | | 5) REFER TO SECTION 504.8.4.1 SPECIFIED LENGTH | | AND TABLE 504.8.4.1 2020 FBC (M). CLOTHES | | DRYER EXHAUXT DUCT. | | PLAN REVIEW BY HAROLD MOSER | | [email protected] | | OFFICE 561-805-6732 | | FAX 561-805-6676 | | | | | | | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2023-03-01 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2023-03-01 |
Time |
06:27 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2023-02-28 |
Time |
13:06 |
Sent To |
|
|
Notes |
2023-03-01 06:27:24 | 1ST REVIEW FMC | | PERMIT: 23020018 | | | | CODES IN EFFECT: 2020 | | | | FBC- FLORIDA BUILDING CODE | | FMC- FLORIDA MECHANICAL CODE | | FEC- FLORIDA ENERGY CONSERVATION | | FGC- FLORIDA FUEL GAS | | FEX- FLORIDA EXISTING BUILDING CODE | | FRC- FLORIDA RESIDENTIAL BUILDING CODE | | F.S.- FLORIDA STATUTES | | FAC- FLORIDA ACCESSIBILITY CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) PROVIDE A KEY PLAN FOR THIS PROJECT INDICATING THE | | LOCATION OF THE PROJECT TO INDICATE THE AIR INTAKES AND | | EXHAUST TERMINATION LOCATIONS WILL MEET THE | | REQUIREMENTS OF FMC 401 INTAKES AND FMC 501 EXHAUST | | TERMINATION LOCATIONS. | | | | 2) ADD A NOTE ON THE MECHANICAL DRAWING STATING THAT | | THE GENERATOR WILL REQUIRE A SEPARATE APPLICATION WITH | | DOCUMENTS AND SEPARATE PLAN REVIEW AS THE GENERATOR | | WILL NOT BE REVIEWED UNDER THIS PERMIT. | | | | 3) SHOW THAT THE PARKING GARAGE WILL MEET THE | | VENTILATION REQUIREMENTS OF FMC 404.1 AND PROVIDE THE | | DRAWING SHOWING THE DESIGN. | | | | 4) SHOW THE GARAGE EXHAUST FANS MEET THE EXHAUST | | DISCHARGE REQUIREMENTS OF 10 FEET FROM OPERABLE | | OPENINGS. FMC 501.3 EXCEPTION 2. | | | | 5) SHEET M600: THE FOLLOWING OCCUPANCY CLASSIFICATIONS | | SHOULD BE CALCULATED WITH THE OCCUPANT DENSITY FROM FMC | | 403.3.1.1 AND NOT THE ARCHITECT???S EGRESS COUNT. | | FITNESS, LOUNGE, CONFERENCE. ALSO SPECIFY THE FITNESS | | ROOM, IS IT AEROBICS OR WEIGHTS? FMC 403.3.1.1 | | | | 6) THE OCCUPANT COUNT FOR THE BREAKROOM SHOULD ALSO BE | | CALCULATED BY USING THE OCCUPANCY CLASSIFICATION THAT | | MOST RESEMBLES THE USE OF SPACE AS DETERMINED IN FMC | | TABLE 403.3.1.1. A BREAKROOM IS NORMALLY ASSOCIATED AS | | A PLACE FOR EMPLOYEES TO USE DURING A BREAK FROM WORK, | | AS TO RELAX, SOCIALIZE OR EAT. FMC 403.3.1.1 | | | | 7) SHEET M600: AHU-1 AND AHU-2 ARE SHOWN IN THE | | MECHANICAL EQUIPMENT SIZING CALCULATIONS. AHU???S | | 3A,3B,3C AND 3D ARE NOT INCLUDED IN THE MECHANICAL | | EQUIPMENT SIZING CALCULATIONS. PROVIDE THESE AHU???S IN | | THE MECHANICAL EQUIPMENT SIZING CALCULATIONS. FEC | | C403.2.1 | | | | 8) SHEET M1.00: EXPLAIN HOW THE GENERATOR ROOM WILL BE | | PROVIDED WITH MAKE UP AIR FOR THE EXHAUSTED AIR. FMC | | 501.4 | | | | 9) SHEET M1.00: EXPLAIN THE 48 X 22 DUCT THAT IS GOING | | UP TO THE COURTYARD. WHAT IS THE USE OF THIS DUCTWORK? | | FBC 107.3.5 | | | | 10) SHOW THE PENETRATION PROTECTION REQUIRED FOR THE 10 | | X 10 O/A DUCT WORK AT THE FLOOR/CEILING OF FIRST FLOOR. | | FMC 607 | | | | 11) SHEET M4.00: SHOW THE OUTDOOR AIR DUCTWORK FOR THE | | AHU???S 3C AND 3D. FMC 403.3.1.1 | | | | 12) PROVIDE THE VENTILATION METHOD, NATURAL OR | | MECHANICAL, FOR EACH UNIT. IF NATURAL SHOW THE | | CALCULATIONS, IF MECHANICAL SHOW THE DUCTWORK FOR THE | | OUTDOOR AIR. FMC 402 OR 403. | | | | 13) PROVIDE THE DRYER DUCT LENGTHS FOR THE UNIT DRYERS. | | FMC 504.8.5 | | | | 14) SHOW THE CFM???S OF EXHAUST FOR THE DRYERS AND IF | | NEEDED SHOW HOW THE MAKEUP AIR WILL BE BROUGHT INTO THE | | DRYER CLOSET. FMC 504.6 | | | | 15) ADD A NOTE STATING THAT ALL ENVIRONMENTAL AIR WILL | | TERMINATE A MINIMUM OF 3 FEET FROM ALL OPERABLE | | OPENINGS INTO THE BUILDING. FMC 501.3 EXCEPTION 3 | | | | 16) SHOW THE RETURN AIR PATH FROM THE BEDROOMS OF THE | | UNITS THAT HAVE A DOOR SEPARATING THE BEDROOM FROM THE | | LIVING SPACE. FMC 601.6 | | | | 17) SHOW THE DOORS FOR THE AHU CLOSETS WILL MEET THE | | RETURN AIR AND THE MATERIAL OF THE DOORS WILL MEET FMC | | 602.2.1 MATERIALS IN PLENUMS. | | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM. | | | | MICHAEL EDWARDS | | MECHANICAL EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL. 33401 | | 561-805-6728 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2023-05-12 |
|
|
Cont ID |
|
Sent By |
rwbrown |
Date |
2023-05-12 |
Time |
11:29 |
Rev Time |
0.00 |
Received By |
rwbrown |
Date |
2023-05-12 |
Time |
10:32 |
Sent To |
|
|
Notes |
2023-05-12 11:29:12 | 1ST PLUMBING REVIEW | | | | THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED | | BY RYAN BROWN WITH THE FOLLOWING COMMENTS. | | | | 1. NOT ADDRESSED. A BACKFLOW PERMIT AND AN INTERCEPTOR | | PERMIT MUST BE APPLIED FOR BEFORE THIS COMMENT CAN BE | | RELEASED. 2017 WPB AMEND - 105.1/107.3 -- THE BACKFLOW | | DEVICE AT THE UTILITY CONNECTION AND THE GREASE TRAP | | REQUIRE SEPARATE PERMITS THAT ARE REQUIRED TO BE | | APPLIED FOR PRIOR TO ISSUANCE OF THE PRIMARY PERMIT (AS | | APPLICABLE). YOU CAN SUBMIT AN APPLICATION "TBD" (TO BE | | DETERMINED) IF YOU DO NOT HAVE A CONTRACTOR SELECTED BY | | EMAILING A COMPLETED PERMIT APPLICATION TO | | [email protected]. AFTER YOU HAVE THE PERMIT(S) | | GENERATED, NOTIFY ME VIA EMAIL OR NOTE IN THE RESPONSE | | LETTER AND I WILL COMPLY THIS COMMENT. | | A) DONE | | B) UNDETERMINED -- | | THE GREASE WASTE HAS ONLY ONE RISER. IF IT IS THE | | INTENT TO PROVIDE GREASE WASTE ACCESS TO ALL THREE | | STORE FRONTS, SHOW CONTINUATION TO ALL THREE . | | | | 2. DONE | | | | 3. DONE | | | | 4. DONE | | | | 5. DONE | | | | 6. DONE | | | | 7. DONE | | | | 8. DONE | | | | 9. DONE | | | | 10. DONE | | | | 11. DONE | | | | 12. DONE | | | | 13. DONE | | | | 14. DONE | | | | 15. DONE | | | | 16. DONE | | | | 17. DONE | | | | 18. DONE | | | | 19. NEW COMMENT - 2017 WPB AMENDS 107.3.5.1.3 - PLEASE | | ADD A DETAIL OF THE INTERCEPTOR INTENDED TO BE | | UTILIZED. EVEN THOUGH A SEPARATE PERMIT IS REQUIRED, | | THESE DETAILS ARE INCLUDED IN THIS REVIEW. | | | | 20. NEW COMMENT - 2020 FPC 607.1.1/613.1 - PAGE #P500 - | | DETAIL #5 -- ALL WATER HEATER THAT ARE NOT | | "RESIDENTIAL" ARE REQUIRED TO HAVE A THERMOSTATIC | | MIXING DEVICE INSTALLED AT THE WATER HEATER. THE | | THERMOSTATIC MIXING DEVICE FOR THIS REQUIREMENT SHOULD | | MEET THE ASSE 1017 STANDARD. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM. | | | | | | RYAN W. BROWN | | CHIEF PLUMBING INSPECTOR | | OFFICE: 561-805-6692 | | CELL: 561-517-4293 | | EMAIL: [email protected] | | | | | | V7 FPC - 2020 FLORIDA PLUMBING CODE | | V7 FGC - 2020 FLORIDA FUEL GAS | | V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE | | V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE | | V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE | | V7 FEC - 2020 FLORIDA ENERGY CONSERVATION | | 2021 F.S. - 2021 FLORIDA STATUTES | | 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE | | 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE | | FBC CHAPTER 1 | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2023-02-15 |
|
|
Cont ID |
|
Sent By |
rwbrown |
Date |
2023-02-15 |
Time |
14:37 |
Rev Time |
0.00 |
Received By |
rwbrown |
Date |
2023-02-14 |
Time |
08:36 |
Sent To |
|
|
Notes |
2023-02-14 11:44:55 | 1ST PLUMBING REVIEW | | | | THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED | | BY RYAN BROWN WITH THE FOLLOWING COMMENTS. | | | | 1. 2017 WPB AMEND - 105.1/107.3 -- THE BACKFLOW DEVICE | | AT THE UTILITY CONNECTION AND THE GREASE TRAP REQUIRE | | SEPARATE PERMITS THAT ARE REQUIRED TO BE APPLIED FOR | | PRIOR TO ISSUANCE OF THE PRIMARY PERMIT (AS | | APPLICABLE). YOU CAN SUBMIT AN APPLICATION "TBD" (TO BE | | DETERMINED) IF YOU DO NOT HAVE A CONTRACTOR SELECTED BY | | EMAILING A COMPLETED PERMIT APPLICATION TO | | [email protected]. AFTER YOU HAVE THE PERMIT(S) | | GENERATED, NOTIFY ME VIA EMAIL OR NOTE IN THE RESPONSE | | LETTER AND I WILL COMPLY THIS COMMENT. | | A) PLEASE PROVIDE A PROJECTED GREASE CALCULATION WITH | | INTERCEPTOR DETAILS | | B) THE GREASE WASTE HAS ONLY ONE RISER. IF IT IS THE | | INTENT TO PROVIDE GREASE WASTE ACCESS TO ALL THREE | | STORE FRONTS, SHOW CONTINUATION TO ALL THREE . | | | | 2. PAGE P4.01 - DETAIL #4/PAGE P7.04 - DETAIL #2 - UNIT | | K -- BATHROOM GROUP - 2020 FPC 912.2.1 - ONLY ONE | | FIXTURE IS ALLOWED TO BE UPSTREAM OF THE VENTED | | FIXTURE'S CONNECTION TO THE HORIZONTAL WET VENT. | | CURRENTLY, THE SHOWER AND WATER CLOSET ARE BOTH | | UPSTREAM. | | | | 3. PAGE P4.01 - DETAIL #5/PAGE P7.04 - DETAIL #3 - UNIT | | L -- BATHROOM GROUP - 2020 FPC 912.2.1 - ONLY ONE | | FIXTURE IS ALLOWED TO BE UPSTREAM OF THE VENTED | | FIXTURE'S CONNECTION TO THE HORIZONTAL WET VENT. | | CURRENTLY, THE SHOWER AND WATER CLOSET ARE BOTH | | UPSTREAM. | | | | 4. PAGE P4.01 - DETAIL #5/PAGE P7.04 - DETAIL #3 - UNIT | | L - S-1 -- 2020 FPC 909.2 - THE KITCHEN DRAIN IS | | NON-COMPLIANT. THE FALL OF THE FIXTURE DRAIN CANNOT | | EXCEED THE DIAMETER OF THE PIPE, NOR CAN THE VENT | | CONNECTION BE BELOW THE WEIR OF THE TRAP. ALSO, THE | | VENT CONNECTION FROM THE DRAIN TO THE VENT STACK MUST | | RISE VERTICALLY 6" ABOVE THE FLOOD RIM OF THE | | FIXTURE(S) SERVED BEFORE GOING HORIZONTAL PER 905.4. | | | | 5. PAGE P4.01 - DETAIL #6/PAGE P7.04 - DETAIL #4 - UNIT | | M -- BATHROOM GROUP - THE FLOOR PLAN ON PAGE 4.01 #6 | | DOES NOT MATCH THE ISOMETRIC ON PAGE P7.01 - THE FLOOR | | PLAN HAS THIS PROBLEM BUT THE ISOMETRIC IS DRAWN | | CORRECTLY. CORRECT THE DRAWING ON P4.01 TO HAVE ONLY | | ONE TRAP UPSTREAM OF THE VENTED FIXTURE'S CONNECTION. | | 2020 FPC 912.2.1 - ONLY ONE FIXTURE IS ALLOWED TO BE | | UPSTREAM OF THE VENTED FIXTURE'S CONNECTION TO THE | | HORIZONTAL WET VENT. CURRENTLY, THE SHOWER AND WATER | | CLOSET ARE BOTH UPSTREAM. | | | | 6. SEVERAL PLACES THROUGHOUT THE WATER RISERS THE HW | | AND CW ARE MISLABLED AND CRISS CROSSED. CHECK FOR | | ACCURACY. | | | | 7. P7.00 DETAIL #1 - OVERALL SANITARY RISER - PLEASE | | ADD THE VENT STACKS TO THE SANITARY RISER. | | | | 8. P7.01 DETAIL #1 -- 2017 WPB AMENDS 107.3.5.1.3 - FOR | | CLARITY, WHERE DO THE CONDENSATE RISERS TERMINATE? THEY | | NEED TO BE VENTED AND VENTS NEED TO TERMINATE IN | | ACCORDANCE WITH 903, | | | | 9. 2017 WPB AMENDS 107.3.5.1.3 - PLEASE DETAIL THE | | STORM RISERS FOR ROOF DRAINAGE AND INCLUDE THE GPM FOR | | EACH RISER AND HORIZONTAL. | | | | 10. 2017 WPB AMENDS 107.3.5.1.3 - SHOW A DETAIL FOR THE | | SUMP PUMP FOR THE ELEVATOR SHAFTS THAT INCLUDES THE OIL | | ALARM OR INTERCEPTOR REQUIRED BY 1003.4. | | | | 11. 2020 FPC 403.1.1 - FLOORS 1 APPEARS TO HAVE A | | REQUIREMENT FOR TWO BATHROOMS, 1 MALE AND 1 FEMALE. | | ONLY ONE IS PROVIDED. PER 403.2.1 - YOU COULD PROVIDE | | FAMILY OR ASSISTED-USE TOILET FACILITIES, BUT STILL ARE | | REQUIRED TO PROVIDE 2 BATHROOMS. | | | | 12. 2020 FPC 403.1.1 - FLOOR 2 - THE OCCUPANT LOAD | | REQUIRES MORE WATER CLOSETS THAN THOSE PROVIDED. | | | | 13. 2020 FPC 403.1.1 - FLOOR 3 - THE OCCUPANT LOAD | | TABLE HAS 2ND FLOOR IN THE COLUMN TO THE LEFT BUT IS | | FOR FLOOR 3. AND IT APPEARS THAT THE OCCUPANT LOAD | | NEEDS TO BE RECONFIGURED. IT DOES NOT APPEAR TO BE | | ACCURATE. PLEASE CHECK AND RECONFIGURE. | | | | 14. 2017 WPB AMENDS 107.3.5.1.3 - PLEASE INCLUDE THE | | HOT WATER PIPING DETAILS AND WHERE THE HOT WATER SOURCE | | WILL BE. | | | | 15. PAGE A1.2.2 - POOL EQUIP. - 2017 WPB AMENDS | | 107.3.5.1.3 - ALTHOUGH THE POOL WILL BE ON A SEPARATE | | PERMIT, PLEASE DETAIL A COMPLIANT DRAIN FOR THE | | DISCHARGE OF THE POOL EQUIPMENT. | | NOTE FOR POOL DISCHARGE: | | SEC 90 - 205 EXCEPTIONS TO DISCHARGING POOL WASTE INTO | | STORM WATER SYSTEM | | SWIMMING POOL WATER SHALL NOT BE DISCHARGED TO | | SANITARY SEWER WITHOUT PRIOR APPROVAL FROM THE PUBLIC | | UTILITIES DEPARTMENT. | | SWIMMING POOL WATER MAY BE DISCHARGED TO THE CITY | | STORM WATER SEWER ONLY IF THE WATER IS DECHLORINATED | | ACCORDING TO SECTION 90-205(1) OF THE CITY OF WEST PALM | | BEACH CODE OF ORDINANCES. SUBMIT THE MANUFACTURER'S | | SPECIFICATION FOR THE DICHLORINATION SYSTEM FOR REVIEW | | AND STAMPING BEFORE THE INSPECTION. AT THE TIME OF POOL | | WATER DISCHARGE, THE FOLLOWING WILL BE REQUIRED: | | - THE RECEIVING INLET MUST BE PROTECTED (FILTER CLOTH | | TO KEEP EXCESS SEDIMENTS FROM ROADWAY WASHING INTO THE | | INLET). | | - NO DISCHARGE HOSE CAN BE DIRECTLY INSERTED INTO THE | | INLET TO DISCHARGE EFFLUENT. | | - WHENEVER POSSIBLE, DISCHARGE EFFLUENT SHALL BE | | ALLOWED TO FILTER THROUGH GRASS AREA ON THE POOL | | OWNER'S PROPERTY BEFORE DISCHARGING ON CITY PROPERTY. | | - DISCHARGE SHALL NOT FLOOD STREETS OR NEIGHBORING | | PROPERTY. | | - FOR TECHNICAL QUESTIONS, CONTACT O&M SUPERINTENDENT | | STEPHON HARRIS AT [email protected] OR 561-822-2168. | | - FOR STORM WATER DISCHARGE COMPLIANCE QUESTIONS, | | PLEASE CONTACT CHRIS JACKSON, ENVIRONMENTAL COMPLIANCE | | SPECIALIST III, PUBLIC UTILITIES DEPARTMENT, (561) | | 822-2062 OR [email protected]. | | | | 16. 2020 FPC 607.1.2/419.5 - PLEASE ADD A DETAIL AND | | SHOW COMPLIANCE FOR THE LIMITING DEVICE REQUIRED FOR | | PUBLIC HANDWASHING FACILITIES AND TEMPERED WATER. THE | | DEVICE SHOULD CONFORM TO ASSE 1070. | | | | 17. 2017 WPB AMENDS 107.3.5.1.3 - INCLUDE IN THE | | FIXTURE SCHEDULE THE FIXTURES FOR THE RESIDENTIAL | | UNITS, WATER SUB-METERS, COMMON WATER HEATER, ETC. | | | | 18. 2017 WPB AMENDS 107.3.5.1.3 - TYPICALLY THERE ARE | | EXTERIOR HOSE BIBS, IF APPLICABLE, ADD THESE TO THE | | PLAN. | | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM. | | | | | | RYAN W. BROWN | | CHIEF PLUMBING INSPECTOR | | OFFICE: 561-805-6692 | | CELL: 561-517-4293 | | EMAIL: [email protected] | | | | | | V7 FPC - 2020 FLORIDA PLUMBING CODE | | V7 FGC - 2020 FLORIDA FUEL GAS | | V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE | | V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE | | V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE | | V7 FEC - 2020 FLORIDA ENERGY CONSERVATION | | 2021 F.S. - 2021 FLORIDA STATUTES | | 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE | | 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE | | FBC CHAPTER 1 | | |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
N |
Date |
2023-03-08 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2023-03-08 |
Time |
16:04 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2023-03-08 |
Time |
16:04 |
Sent To |
|
|
Notes |
2023-03-08 16:05:57 | ROOFING PRODUCT APPROVALS HAVE BEEN DEFERRED. |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2023-06-15 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2023-06-15 |
Time |
08:40 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2023-06-15 |
Time |
08:40 |
Sent To |
|
|
Notes |
2023-06-02 16:44:22 | SOME OF THE STRUCTURAL SHEETS ARE NOT DIGITALLY SIGNED. |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2023-03-27 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2023-03-27 |
Time |
16:48 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2023-03-27 |
Time |
16:48 |
Sent To |
|
|
Notes |
2023-03-27 16:55:33 | THE ENGINEER, GREGORY F. BOLDEN, SELF-CERTIFIED HIS | | DIGITAL SIGNATURE ON THE CIVIL DRAWINGS, SHEETS C1 THRU | | C7. THE FLORIDA BOARD OF PROFESSIONAL ENGINEERS | | REQUIRES THE DIGITAL SIGNATURE TO BE CERTIFIED BY AN | | APPROVED THIRD PARTY CERTIFICATION AGENCY. FS 471 & FAC | | 61G15 | 2023-03-01 06:28:08 | MECHANICAL DIGITAL SIGNATURES APPROVED ME |
|
|
Review Stop |
THRESHOLD |
THRESHOLD INSPECTOR DOCUMENTS |
Rev No |
2 |
Status |
F |
Date |
2023-06-02 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2023-06-02 |
Time |
15:13 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2023-06-02 |
Time |
15:13 |
Sent To |
|
|
Notes |
2023-06-02 15:14:15 | THRESHOLD DOCUMENTS HAVE NOT BEEN SUBMITTED, |
|
|
Review Stop |
THRESHOLD |
THRESHOLD INSPECTOR DOCUMENTS |
Rev No |
1 |
Status |
F |
Date |
2023-03-27 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2023-03-27 |
Time |
13:01 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2023-03-27 |
Time |
13:01 |
Sent To |
|
|
Notes |
2023-03-27 13:03:27 | PLAN REVIEW COMMENTS | | | | 1ST REVIEW: FBC SEVENTH EDITION (2020) | | ROBERT MCDOUGAL, CBO | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561) 805-6714 | | [email protected] | | | | DENIED BY BUILDING | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | SUBMIT THRESHOLD DOCUMENTS. SEE BUILDING REVIEW | | COMMENTS. | | | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2023-06-08 |
|
|
Cont ID |
|
Sent By |
cibaven |
Date |
2023-06-08 |
Time |
08:40 |
Rev Time |
0.00 |
Received By |
cibaven |
Date |
2023-06-08 |
Time |
08:39 |
Sent To |
|
|
Notes |
2023-06-08 08:40:24 | A MINOR AMENDMENT IS IN REVIEW. AS STATED ON THE FSPR | | NO. 22-01 (Z22020019) APPROVAL LETTER, THE FOLLOWING | | ITEMS SHALL BE ADDRESSED DURING THE BUILDING PERMIT | | PROCESS, PLEASE SUBMIT WRITTEN RESPONSES TO EXPLAIN IF | | YOU HAVE OR WHEN YOU WILL ADDRESS THE ITEMS: | | | | 1. FINAL ACQUISITION OF THE 500 CLEMATIS STREET | | PROPERTY FROM THE CITY OF WEST PALM BEACH. | | | | 2. THE PROPERTY SHALL BE RE-PLATTED. | | | | 3. THE DEVELOPER SHALL BE RESPONSIBLE FOR ANY | | INFRASTRUCTURE IMPROVEMENTS REQUIRED TO SERVE THE | | PROJECT. | | | | 4. ALL STREETLIGHTS, TREE GRATES, BOLLARDS, PAVERS OR | | ANY OTHER STREETSCAPE ELEMENTS INSTALLED WITHIN THE | | CITY???S ROW BY THE PROJECT SHALL COMPLY WITH CITY???S | | STANDARDS AND SHALL BE APPROVED BY THE PLANNING | | DIVISION AND THE ENGINEERING SERVICES DEPARTMENT DURING | | THE BUILDING PERMIT PROCESS. ANY FEES ASSOCIATED WITH | | THE REMOVAL OF EXISTING STREETLIGHTS SHALL BE A COST TO | | THE DEVELOPER. | | | | 5. THE PROJECT IS REQUIRED TO COMPLY WITH THE ARTLIFE | | ORDINANCE, AND A PROPOSED LOCATION FOR THE ART ELEMENT | | SHALL BE INDICATED IN THE SITE PLAN. | | | | 6. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE | | RESPONSIBLE FOR THE PERMITTING AND INSTALLATION OF THE | | STREET TREES, LANDSCAPING, IRRIGATION, LIGHTING AND | | HARDSCAPING WITHIN THE RIGHT OF WAY APPROVED WITH THIS | | PETITION. | | | | 7. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON | | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE | | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT | | SERVICES DEPARTMENT, PLANNING DIVISION. THE TREES AND | | PALMS ON SITE WILL BE REEVALUATED AT THE TIME OF | | PERMITTING TO DETERMINE THEIR CONDITION AND ANY | | MITIGATION DUE WILL BE CALCULATED. | | | | 8. THE APPLICANT SHALL PROVIDE IRRIGATION FOR THE | | ADJACENT QUADRILLE PLAZA DRIVE FROM THE PROJECT SITE. | | EXISTING IRRIGATION IS TO BE MODIFIED TO REMOVE THIS | | AREA FROM THE SYSTEM. THE APPLICANT WILL BE RESPONSIBLE | | FOR RELOCATING THE WATER METER AND BACKFLOW FROM THE | | SITE TO A LOCATION SPECIFIED BY THE CITY TO SERVICE THE | | REMAINING AREAS ON THE EAST SIDE OF THE ROAD. WATERING | | OF THE EXISTING STREET TREES SHALL BE MAINTAINED AT ALL | | TIMES DURING CONSTRUCTION. | | | | 9. FOR BUILDING PERMIT, THE SHEET L3.0 RENDERING SHALL | | BE REVISED TO MATCH THE LANDSCAPE PLAN. | | | | 10. FOR BUILDING PERMIT SUBMITTAL, SHEETS L2.1 AND L2.2 | | SHALL BE REVISED TO SHOW THE SQUARE FOOTAGE AND | | PERCENTAGE OF THE DESIGNATED TERRACE AREA THAT IS | | VEGETATED AREA TO MEET THE 20% 3 VEGETATED AREA. THE | | TOTAL PRIVATE OPEN SPACE SQUARE FOOTAGE REQUIRED, AND | | THE TOTAL PROVIDED SHALL BE SHOWN ON THE PLAN. | | | | 11. A MINIMUM OF 18 INCHES OF HORIZONTAL CLEARANCE | | SHALL BE PROVIDED BETWEEN THE BACKFLOW ASSEMBLIES AND | | ANY BUSHES. | | | | 13. ENGINEERING PERMIT SHALL BE OBTAINED BEFORE | | SUBMITTAL FOR BUILDING PERMIT. THE FOLLOWING ITEMS | | SHALL BE ADDRESSED DURING THE ENGINEERING PERMIT: | | A. THE WEST SIDE OF THE DRIVEWAY TO THE ALLEY DOES NOT | | APPEAR TO LINE UP WITH THE WALL OPENING. | | B. PROVIDE INFORMATION (RIM, INVERTS, BOTTOM | | ELEVATIONS) OF THE EXISTING CATCH BASIN THAT THE | | STORMWATER PIPE WILL CONNECT TO. | | C. SHOW AND PROVIDE INFORMATION (TYPE, SIZE, MATERIAL, | | ELEVATION) OF DRY UTILITIES IN THE ROW. | | | | 14. SIDEWALK SURFACES AND DRIVEWAYS WITHIN 10 FEET OF | | THE BUILDING FOUNDATION SHALL HAVE A MINIMUM OF 2% | | CROSS SLOPE DIRECTED AWAY FROM THE BUILDING. STORM | | WATER RUNOFF FROM THE SIDEWALK AND DRIVEWAY SHALL BE | | DIRECTED TO FLOW TO THE PROPERTY'S DRAINAGE SYSTEM OR | | TO THE STREET IF APPROVED BY THE CITY'S PUBLIC | | UTILITIES DIRECTOR OR DESIGNEE. | | | | 15. PROJECT SHALL INCREASE THE TOTAL NUMBER OF BIKE | | PARKING PROVIDED WITHIN THE PROJECT FROM 8 SPACES TO A | | MINIMUM OF 34 BIKE PARKING SPACES TO COMPLY WITH THE | | BIKE PARKING PROVISIONS FOR MICRO UNITS AND REGULAR | | UNITS (32 SPACES FOR MICROUNITS AND 2 FOR REGULAR | | UNITS). | | | | 16. PRIOR TO THE ISSUANCE OF THE FIRST BUILDING PERMIT, | | THE APPLICANT SHALL PREPARE A CONSTRUCTION SITE | | SECURITY AND MANAGEMENT PLAN FOR APPROVAL BY THE CITY | | OF WEST PALM BEACH POLICE DEPARTMENT CPTED OFFICIAL. | | | | 17. IN CASE OF PROPOSING ADDITION OF ANY NEW CAN(S) IN | | THE CITY`S RIGHT-OF-WAY , THE LOCATION AND QUANTITY OF | | THE CAN(S) SHALL BE REVIEWED AND APPROVED BY PUBLIC | | WORKS DEPARTMENT AND THE CAN(S) SHALL BE TYPE, SIZE AND | | COLOR APPROVED BY PUBLIC WORKS DEPARTMENT. THE BUILDING | | MAINTENANCE IS RESPONSIBLE TO MAINTAIN AND SERVICE THE | | CAN(S). | | | | 18. ALL THE PARKING STALL PAINTING SHALL COMPLY WITH | | THE CITY`S MUNICIPAL CODE SECTION 94-485 AND FLORIDA | | STATUES [553.5041 F.S.]. | | | | 19. SIGNAGE PLAN. ALL STRIPING AND SIGNAGE SHALL COMPLY | | WITH THE LATEST CITY OF WEST PALM BEACH STANDARD | | DETAILS AND MEET THE M.U.T.C.D. LATEST EDITION. | | | | 20. ALL PAVEMENT MARKING, SIGNING AND SIDEWALK DAMAGED | | DURING CONSTRUCTION SHALL BE RESTORED. 4 | | | | THE FOLLOWING ITEMS SHALL BE ADDRESSED PRIOR TO | | ISSUANCE OF FINAL CO: | | 21. PAVEMENT SHALL BE RESURFACED IN ACCORDANCE WITH | | CITY STANDARDS TO ANY AREA WHERE PAVEMENT MARKINGS ARE | | REMOVED, OR PAVEMENT HAS BEEN DAMAGED DURING | | CONSTRUCTION. | | | | 22. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE | | RESPONSIBLE FOR THE MAINTENANCE OF ANY HARDSCAPE, | | LANDSCAPING AND IRRIGATION, AND ANY OTHER DECORATIVE | | ELEMENT INSTALLED WITHIN THE RIGHT OF WAY BY THIS | | PROJECT. APPROVAL OF A MAINTENANCE AGREEMENT BETWEEN | | THE CITY AND THE APPLICANT, SUCCESSORS AND ASSIGNS WILL | | BE REQUIRED BEFORE FINAL CO. | | | | 23. PROJECT WILL BE REQUIRED TO CONTRIBUTE TO A TRANSIT | | FEE EQUAL TO $10/MONTH PER EACH MICRO UNIT INCLUDED IN | | THE PROJECT (TOTAL NUMBER OF MICRO UNITS PROPOSED). THE | | FIRST PAYMENT WILL BE DUE AT THE TIME OF FINAL CO. THE | | TRANSIT FEE CONTRIBUTION IS IN PERPETUITY OR FOR THE | | TIME THE MICRO UNITS EXIST. | | | | CLAUDIA D. IBAVEN | | CITY URBAN DESIGNER / ZONING AND PLANNING | | [email protected] | | 561-822-1402 | | | | | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2023-03-10 |
|
|
Cont ID |
|
Sent By |
CIbaven |
Date |
2023-03-10 |
Time |
16:15 |
Rev Time |
0.00 |
Received By |
cibaven |
Date |
2023-03-10 |
Time |
16:14 |
Sent To |
|
|
Notes |
2023-03-10 16:14:52 | A MINOR AMENDMENT NEEDS TO BE SUBMITTED FOR APPROVAL | | PRIOR REVIEWING THE BUILDING PERMIT. AS STATED ON THE | | FSPR NO. 22-01 (Z22020019) APPROVAL LETTER, THE | | FOLLOWING ITEMS SHALL BE ADDRESSED DURING THE BUILDING | | PERMIT PROCESS: | | | | 1. FINAL ACQUISITION OF THE 500 CLEMATIS STREET | | PROPERTY FROM THE CITY OF WEST PALM BEACH. | | | | 2. THE PROPERTY SHALL BE RE-PLATTED. | | | | 3. THE DEVELOPER SHALL BE RESPONSIBLE FOR ANY | | INFRASTRUCTURE IMPROVEMENTS REQUIRED TO SERVE THE | | PROJECT. | | | | 4. ALL STREETLIGHTS, TREE GRATES, BOLLARDS, PAVERS OR | | ANY OTHER STREETSCAPE ELEMENTS INSTALLED WITHIN THE | | CITY???S ROW BY THE PROJECT SHALL COMPLY WITH CITY???S | | STANDARDS AND SHALL BE APPROVED BY THE PLANNING | | DIVISION AND THE ENGINEERING SERVICES DEPARTMENT DURING | | THE BUILDING PERMIT PROCESS. ANY FEES ASSOCIATED WITH | | THE REMOVAL OF EXISTING STREETLIGHTS SHALL BE A COST TO | | THE DEVELOPER. | | | | 5. THE PROJECT IS REQUIRED TO COMPLY WITH THE ARTLIFE | | ORDINANCE, AND A PROPOSED LOCATION FOR THE ART ELEMENT | | SHALL BE INDICATED IN THE SITE PLAN. | | | | 6. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE | | RESPONSIBLE FOR THE PERMITTING AND INSTALLATION OF THE | | STREET TREES, LANDSCAPING, IRRIGATION, LIGHTING AND | | HARDSCAPING WITHIN THE RIGHT OF WAY APPROVED WITH THIS | | PETITION. | | | | 7. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON | | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE | | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT | | SERVICES DEPARTMENT, PLANNING DIVISION. THE TREES AND | | PALMS ON SITE WILL BE REEVALUATED AT THE TIME OF | | PERMITTING TO DETERMINE THEIR CONDITION AND ANY | | MITIGATION DUE WILL BE CALCULATED. | | | | 8. THE APPLICANT SHALL PROVIDE IRRIGATION FOR THE | | ADJACENT QUADRILLE PLAZA DRIVE FROM THE PROJECT SITE. | | EXISTING IRRIGATION IS TO BE MODIFIED TO REMOVE THIS | | AREA FROM THE SYSTEM. THE APPLICANT WILL BE RESPONSIBLE | | FOR RELOCATING THE WATER METER AND BACKFLOW FROM THE | | SITE TO A LOCATION SPECIFIED BY THE CITY TO SERVICE THE | | REMAINING AREAS ON THE EAST SIDE OF THE ROAD. WATERING | | OF THE EXISTING STREET TREES SHALL BE MAINTAINED AT ALL | | TIMES DURING CONSTRUCTION. | | | | 9. FOR BUILDING PERMIT, THE SHEET L3.0 RENDERING SHALL | | BE REVISED TO MATCH THE LANDSCAPE PLAN. | | | | 10. FOR BUILDING PERMIT SUBMITTAL, SHEETS L2.1 AND L2.2 | | SHALL BE REVISED TO SHOW THE SQUARE FOOTAGE AND | | PERCENTAGE OF THE DESIGNATED TERRACE AREA THAT IS | | VEGETATED AREA TO MEET THE 20% 3 VEGETATED AREA. THE | | TOTAL PRIVATE OPEN SPACE SQUARE FOOTAGE REQUIRED, AND | | THE TOTAL PROVIDED SHALL BE SHOWN ON THE PLAN. | | | | 11. A MINIMUM OF 18 INCHES OF HORIZONTAL CLEARANCE | | SHALL BE PROVIDED BETWEEN THE BACKFLOW ASSEMBLIES AND | | ANY BUSHES. | | | | 13. ENGINEERING PERMIT SHALL BE OBTAINED BEFORE | | SUBMITTAL FOR BUILDING PERMIT. THE FOLLOWING ITEMS | | SHALL BE ADDRESSED DURING THE ENGINEERING PERMIT: | | A. THE WEST SIDE OF THE DRIVEWAY TO THE ALLEY DOES NOT | | APPEAR TO LINE UP WITH THE WALL OPENING. | | B. PROVIDE INFORMATION (RIM, INVERTS, BOTTOM | | ELEVATIONS) OF THE EXISTING CATCH BASIN THAT THE | | STORMWATER PIPE WILL CONNECT TO. | | C. SHOW AND PROVIDE INFORMATION (TYPE, SIZE, MATERIAL, | | ELEVATION) OF DRY UTILITIES IN THE ROW. | | | | 14. SIDEWALK SURFACES AND DRIVEWAYS WITHIN 10 FEET OF | | THE BUILDING FOUNDATION SHALL HAVE A MINIMUM OF 2% | | CROSS SLOPE DIRECTED AWAY FROM THE BUILDING. STORM | | WATER RUNOFF FROM THE SIDEWALK AND DRIVEWAY SHALL BE | | DIRECTED TO FLOW TO THE PROPERTY???S DRAINAGE SYSTEM OR | | TO THE STREET IF APPROVED BY THE CITY???S PUBLIC | | UTILITIES DIRECTOR OR DESIGNEE. | | | | 15. PROJECT SHALL INCREASE THE TOTAL NUMBER OF BIKE | | PARKING PROVIDED WITHIN THE PROJECT FROM 8 SPACES TO A | | MINIMUM OF 34 BIKE PARKING SPACES TO COMPLY WITH THE | | BIKE PARKING PROVISIONS FOR MICRO UNITS AND REGULAR | | UNITS (32 SPACES FOR MICROUNITS AND 2 FOR REGULAR | | UNITS). | | | | 16. PRIOR TO THE ISSUANCE OF THE FIRST BUILDING PERMIT, | | THE APPLICANT SHALL PREPARE A CONSTRUCTION SITE | | SECURITY AND MANAGEMENT PLAN FOR APPROVAL BY THE CITY | | OF WEST PALM BEACH POLICE DEPARTMENT CPTED OFFICIAL. | | | | 17. IN CASE OF PROPOSING ADDITION OF ANY NEW CAN(S) IN | | THE CITY`S RIGHT-OF-WAY , THE LOCATION AND QUANTITY OF | | THE CAN(S) SHALL BE REVIEWED AND APPROVED BY PUBLIC | | WORKS DEPARTMENT AND THE CAN(S) SHALL BE TYPE, SIZE AND | | COLOR APPROVED BY PUBLIC WORKS DEPARTMENT. THE BUILDING | | MAINTENANCE IS RESPONSIBLE TO MAINTAIN AND SERVICE THE | | CAN(S). | | | | 18. ALL THE PARKING STALL PAINTING SHALL COMPLY WITH | | THE CITY`S MUNICIPAL CODE SECTION 94-485 AND FLORIDA | | STATUES [553.5041 F.S.]. | | | | 19. SIGNAGE PLAN. ALL STRIPING AND SIGNAGE SHALL COMPLY | | WITH THE LATEST CITY OF WEST PALM BEACH STANDARD | | DETAILS AND MEET THE M.U.T.C.D. LATEST EDITION. | | | | 20. ALL PAVEMENT MARKING, SIGNING AND SIDEWALK DAMAGED | | DURING CONSTRUCTION SHALL BE RESTORED. 4 | | | | THE FOLLOWING ITEMS SHALL BE ADDRESSED PRIOR TO | | ISSUANCE OF FINAL CO: | | 21. PAVEMENT SHALL BE RESURFACED IN ACCORDANCE WITH | | CITY STANDARDS TO ANY AREA WHERE PAVEMENT MARKINGS ARE | | REMOVED, OR PAVEMENT HAS BEEN DAMAGED DURING | | CONSTRUCTION. | | | | 22. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE | | RESPONSIBLE FOR THE MAINTENANCE OF ANY HARDSCAPE, | | LANDSCAPING AND IRRIGATION, AND ANY OTHER DECORATIVE | | ELEMENT INSTALLED WITHIN THE RIGHT OF WAY BY THIS | | PROJECT. APPROVAL OF A MAINTENANCE AGREEMENT BETWEEN | | THE CITY AND THE APPLICANT, SUCCESSORS AND ASSIGNS WILL | | BE REQUIRED BEFORE FINAL CO. | | | | 23. PROJECT WILL BE REQUIRED TO CONTRIBUTE TO A TRANSIT | | FEE EQUAL TO $10/MONTH PER EACH MICRO UNIT INCLUDED IN | | THE PROJECT (TOTAL NUMBER OF MICRO UNITS PROPOSED). THE | | FIRST PAYMENT WILL BE DUE AT THE TIME OF FINAL CO. THE | | TRANSIT FEE CONTRIBUTION IS IN PERPETUITY OR FOR THE | | TIME THE MICRO UNITS EXIST. | | | | CLAUDIA D. IBAVEN | | CITY URBAN DESIGNER / ZONING AND PLANNING | | [email protected] | | 561-822-1402 | | | | | | |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |