Plan Review Details - Permit 23011480
Plan Review Stops For Permit 23011480
Review Stop AD ADDRESSING
Rev No 1 Status P Date 2023-02-03 Cont ID  
Sent By cpuell Date 2023-02-03 Time 13:03 Rev Time 0.00
Received By cpuell Date 2023-02-03 Time 13:03 Sent To  
Notes
2023-02-03 13:17:40WORK TO BE DONE ON BLDGS 855 N RAILROAD AVE AND 875 N
 RAILROAD AVE UPDATED PERMIT PARCEL READDRESSED

Review Stop AIPP ART IN PUBLIC PLACES
Rev No 1 Status P Date 2023-03-10 Cont ID  
Sent By swelter Date 2023-03-10 Time 12:41 Rev Time 0.00
Received By swelter Date 2023-03-10 Time 12:42 Sent To  
Notes
2023-03-10 12:42:09SEE MASTER PERMIT # 22120561

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 3 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 2 Status F Date 2023-05-30 Cont ID  
Sent By pvalenti Date 2023-05-30 Time 14:52 Rev Time 0.00
Received By pvalenti Date 2023-05-30 Time 14:23 Sent To  
Notes
2023-05-30 15:13:42PETER E VALENTI
 BUILDING PLANS EXAMINER II/INSPECTOR
 [email protected]
 561 805 6673
  
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC M = FBC MECHANICAL
 FBC FG = FBC FUEL GAS
  
 FAILED ASBESTOS PLAN REVIEW:
  
 PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS
 REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE:
  
 HTTPS://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVIC
 ES/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION
 -RENOVATION.HTML
  
 IT APPEARS THAT THERE IS AN ASBESTOS ACKNOWLEDGEMENT
 LETTER BY THE CONTRACTOR (HEDRICKS BROTHERS) UNDER THE
 PARTIAL DEMO PERMIT. PLEASE PROVIDE/UPLOAD TO THIS
 DIGITAL PORTAL UNDER THIS PERMIT THE SAME TYPE OF
 LETTER BUT FOR THIS ADDRESS.
  

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status F Date 2023-02-22 Cont ID  
Sent By jwitmer Date 2023-02-22 Time 09:48 Rev Time 0.00
Received By jwitmer Date 2023-02-22 Time 09:46 Sent To  
Notes
2023-02-22 09:48:18COMMERCIAL ASBESTOS
 TO THE BUILDING CONTRACTOR:
 PALM BEACH COUNTY HEALTH DEPARTMENT NEEDS VERIFICATION
 THE CONTRACTORS ARE AWARE OF THIS FL. STATE STATUTE.
 PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS
 REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  
 THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO
 [email protected]. THE INFORMATION SHOULD BE IN
 PDF FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE
 INCLUDE THE PERMIT NUMBER AND "ASBESTOS" IN THE SUBJECT
 LINE.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2023-07-18 Cont ID  
Sent By jwitmer Date 2023-07-17 Time 11:01 Rev Time 0.00
Received By jwitmer Date 2023-07-17 Time 10:33 Sent To  
Notes
2023-07-17 10:41:353RD REVIEW
 DATE: MON. JULY 17TH/23
 ACTION: PASSED/ BUILDING PROVISOS/ DEFERRED SUBMITTALS
  
 1) BUILDING PROVISO: SHEET S.002 HAS HEADING DEALING
 WITH WELDING & STRUCTURAL STEEL FOR THE PROJECT. WELDED
 OR BOLTED CONNECTIONS. THIS BUILDING CONTAINS EITHER
 BOLTED AND OR WELDED CONNECTIONS. THE CONTRACTOR IS
 REQUIRED TO PROVIDE WELD PROCEDURE SPECIFICATIONS &
 WELDER OPERATOR PERFORMANCE QUALIFICATION RECORDS IN
 ACCORDANCE WITH THE REFERENCED STANDARDS AT TIME OF
 INSPECTION FOR FIELD WIELDING, ON THE JOB-SITE
 WIELDING. THIRD PARTY CERTIFICATION WILL BE REQUIRED.
 THE OWNER MAY JUST HIRE A 3RD PARTY ENGINEERING FIRM TO
 COMPLETE AND APPROVE THE FORMER INSPECTIONS. REPORTS
 SUBMITTED TO BUILDING INSPECTOR AT TIME OF FRAMING
 INSPECTION.
 2020 FBC-B 2204.1 WELDING
 1. WELD PROCEDURES SPECIFICATIONS
 2. QUALIFICATIONS OF WELDING PERSONAL
 2017 FBC-B 2204.2 BOLTING.
 IF FURTHER CLARIFICATION AND OR QUESTIONS IS REQUIRED,
 PLEASE CONTACT THE CHIEF BUILDING INSPECTOR RICHARD
 BRUNELLE AT 561-805-6670.
  
 2) BUILDING PROVISO/ DEFERRED SUBMITTALS/ COMPONENTS &
 CLADDING.
 COMPONENTS & CLADDING. PLEASE SUBMIT THE COMPONENTS AND
 CLADDING PRODUCT APPROVALS. 2020 FBC-B 1609.1.2
 PROTECTION OF OPENINGS, 1609.6.4.4.1 COMPONENTS &
 CLADDING. FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS,
 ADMINISTRATIVE CODE 61G20-3.005, RULE 9N-3 NOV. 01/
 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION
 SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS:
 (31)(A) EXTERIOR DOORS, MULLIONS & ROOF HATCHES.
 (B) WINDOWS & MULLIONS
 (C) PANEL WALLS: STOREFRONTS, CURTAIN WALLS, WALL
 LOUVERS, EFIS SYSTEMS,
 (D) ROOFING PRODUCTS AND ASSEMBLIES, LIGHTWEIGHT
 CONCRETE INSULATION, ROOF TOP VENTILATORS
 (G) PRE-ENGINEERED A/C STANDS
  
 3A) W. P. B. 107.3.4. PRODUCT APPROVALS. THOSE PRODUCTS
 WHICH ARE REGULATED BY FLORIDA ADMINISTRATIVE CODE RULE
 61G20 SHALL BE REVIEWED AND APPROVED IN WRITING (SHOP
 DRAWING STAMP OF APPROVAL) BY THE DESIGNER OF RECORD
 PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL.
 FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR
 SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS,
 SHOP DRAWINGS ETC.
  
 3B) DELEGATED ENGINEERING. 61G15-30.003 ENGINEERING
 DOCUMENT CLASSIFICATION. FL 61G-15-30.006 (3) THE
 DELEGATED ENGINEER SHALL FORWARD THE DELEGATED
 ENGINEERING DOCUMENTS TO THE ENGINEER OF RECORD FOR
 REVIEW.
  
 3C) IDENTIFY GLAZING/ MULLIONS. PLEASE IDENTIFY IN THE
 PRODUCT APPROVAL BEFORE SUBMITTING TO DESIGNER OF
 RECORD AND BEFORE SUBMISSION TO THE BUILDING
 DEPARTMENT. FOR ALL PRODUCTS WITH GLAZING, PLEASE
 IDENTIFY THE OPENING WIDTH & HEIGHT, SILL HEIGTH, TYPE
 OF GLAZING, MULLION SIZE, LENGTH IF UNREINFORCED OR
 REINFORCED INFORMATION IF REQUIRED, ATTACHMENTS AND
 ASSOCIATE PRESSURES FOR EACH OPENING SIZE. 2020 FBC-B
 1405.13.1 INSTALLATION. WINDOWS AND DOORS SHALL BE
 INSTALLED IN ACCORDANCE WITH APPROVED MANUFACTURER???S
 INSTRUCTIONS. FASTENER SIZE AND SPACING SHALL BE
 PROVIDED IN SUCH INSTRUCTIONS AND SHALL BE CALCULATED
 BASED ON MAXIMUM LOADS AND SPACING USED IN THE TESTS.
  
 3D) 2020 FBC-BUILDING CODE SECTION 1405.4. FLASHINGS
 SHALL BE INSTALLED AT THE PERIMETERS OF EXTERIOR DOORS
 & WINDOW ASSEMBLIES. WHEN SELF-ADHERED MEMBRANES ARE
 USED AS FLASHINGS IN WALL ASSEMBLIES, THOSE
 SELF-ADHERED FLASHINGS SHALL COMPLY WITH AAMA-711.
  
 3E) ROOFING: FOR ALL ROOFING PRODUCTS PLEASE IDENTIFY
 ALL ROOFING SUB-SYSTEMS AND THEIR ASSOCIATED PRESSURES
 FOR ROOF ZONE # 1. REVIEW THE PRODUCT APPROVAL
 LIMITATIONS, IF ENHANCED FASTENING IS ALLOWED FOR ROOF
 ZONES 2 & 3. FASTENER DENSITIES SHALL BE INCREASED FOR
 BOTH INSULATION & THE BASE SHEET AS CALCULATED IN
 COMPLIANCE WITH ROOFING APPLICATION STANDARDS RAS 117.
 CALCULATION PREPARED, SIGNED AND
 SEALED BY A FLORIDA REGISTERED PROFESSIONAL ENGINEER OR
 REGISTERED ARCHITECT. 1609.6.4.4.1 COMPONENTS &
 CLADDING.
  
 JAMES A. WITMER BN, PX, SFP, CBO/ SENIOR COMMERCIAL
 COMBINATION PLANS EXAMINER
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2023-05-31 Cont ID  
Sent By pvalenti Date 2023-05-31 Time 17:02 Rev Time 0.00
Received By pvalenti Date 2023-05-30 Time 14:23 Sent To  
Notes
2023-05-31 17:04:11PETER E VALENTI
 BUILDING PLANS EXAMINER II/INSPECTOR
 [email protected]
 561 805 6673
  
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC M = FBC MECHANICAL
 FBC FG = FBC FUEL GAS
  
 BUILDING REVIEW APPROVED WITH PROVISOS:
  
 FBC B 1609.1.2, FBC B 1609..4.4.1 & FAC RULES: FL 61G
 20, FL 61G1-23.015, FL 61G15-30, THE FOLLOWING ITEMS
 SHALL BE CONSIDERED DEFERRED SUBMITTALS: EXTERIOR
 DOORS, WINDOWS, MULLIONS, ROOF HATCHES, PANEL WALLS,
 STORE FRONTS, CURTAIN WALLS, WALL LOUVERS, EFIS
 SYSTEMS, ROOFING PRODUCTS AND ASSEMBLIES, LIGHTWEIGHT
 CONCRETE INSULATION, ROOF TOP VENTILATORS,
 PRE-ENGINEERED A/C STANDS. IF THERE ARE ANY SHOP
 DRAWINGS INVOLVED, THE DELEGATED ENGINEER SHALL FORWARD
 THE THE DELEGATED DOCUMENT TO THE ENGINEER OF RECORD
 FOR REVIEW AND SHALL PROVIDE A REVIEW STAMP ON
 DOCUMENTS. THE ARCHITECT IS RESPONSIBLE FOR SUPERVISING
 AND REVIEWING ALL PROJECT DATA, REPORTS, AND SHOP
 DRAWINGS.
  
 FBC B 107.2.1, SHEET S.002 HAS HEADING DEALING
 WITH WELDING & STRUCTURAL STEEL FOR THE PROJECT. WELDED
 OR BOLTED CONNECTIONS. THIS BUILDING CONTAINS EITHER
 BOLTED AND OR WELDED CONNECTIONS. THE CONTRACTOR IS
 REQUIRED TO PROVIDE WELD PROCEDURE SPECIFICATIONS &
 WELDER OPERATOR PERFORMANCE QUALIFICATION RECORDS IN
 ACCORDANCE WITH THE REFERENCED STANDARDS AT TIME OF
 INSPECTION FOR FIELD WIELDING, ON THE JOB???SITE
 WIELDING. THIRD PARTY CERTIFICATION WILL BE REQUIRED.
 THE OWNER MAY JUST HIRE A 3RD PARTY ENGINEERING FIRM TO
 COMPLETE AND APPROVE THE FORMER INSPECTIONS. REPORTS
 SUBMITTED TO BUILDING INSPECTOR AT TIME OF FRAMING
 INSPECTION.
 2020 FBC???B 2204.1 WELDING
 1. WELD PROCEDURES SPECIFICATIONS
 2. QUALIFICATIONS OF WELDING PERSONAL
 2017 FBC???B 2204.2 BOLTING.
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2023-02-22 Cont ID  
Sent By jwitmer Date 2023-02-22 Time 11:05 Rev Time 0.00
Received By jwitmer Date 2023-02-22 Time 09:47 Sent To  
Notes
2023-02-22 09:49:15WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION
 SERVICES/ BUILDING DIVISION
 2020 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 23011480
 ADD: 809 N RAILROAD AVE.
 CONT: HEDRICK BROTHERS CONSTRUCTION
 TEL: 561-308-2954
 E-MAIL: [email protected]
  
 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: WED. 02/22/23
 ACTION: DENIED
  
 1A) THE PLANS AS SUBMITTED LEAVE THE BUILDING AS A
 SHELL BUILDING, NOT A RENOVATION WHERE A CO OR TCO WILL
 BE REQUIRED, MISSING FLOOR SLABS, PLUMBING JUST STUBBED
 UP, NO INTERIOR WALLS OR FINISHES, THIS PERMIT SHOULD
 BE LABELED A RENOVATION TO A SHELL BUILDING.
  
 1B) SINCE THERE ARE 2 BUILDINGS ON THE SAME LOT AND
 EACH BUILDING HAS ITS OWN ADDRESS THE PROJECT SHOULD BE
 BROKEN INTO 2 PERMITS AND ASSIGNING THE NEW CMU BACK
 WALL TO ONE OF THE PERMITS. REVIEWS WOULD STILL BE ABLE
 TO RUN CONCURRENTLY. THE FEES COULD BE SPLIT BETWEEN
 THE 2 PERMITS. THE REASON FOR THE 2 PERMITS, ONE RECORD
 KEEPING DURING THE INSPECTION PHASE AND THE 2ND IS
 RECORD KEEPING AND RETRAVEL OF RECORDS IN THE FUTURE.
 107.2.1.3. QUALITY OF PLANS. THE BUILDING OFFICIAL MAY
 ESTABLISH THROUGH DEPARTMENT POLICY OTHER STANDARDS FOR
 THE PLANS AND SPECIFICATIONS IN ORDER TO PROVIDE
 CONFORMITY TO ITS RECORD RETENTION PROGRAM. THIS POLICY
 MAY INCLUDE SUCH THINGS AS MINIMUM SIZE, SHAPE,
 CONTRAST, CLARITY, OR OTHER ITEMS RELATED TO RECORD
 MANAGEMENT. ELECTRONIC MEDIA MUST BE COMPATIBLE WITH
 THE ARCHIVE REQUIREMENTS OF FLORIDA STATUTES.
 1C) THE OTHER ADVANTAGE IN SPLITTING THE SCOPE OF WORK
 BETWEEN 2 PERMITS IS CURRENTLY THE COMBINED OCCUPANT
 LOAD OF BUILDING A & B IS 381 OCCUPANTS. WITH THE WORK
 SPLIT THE OCCUPANT LOAD WOULD BE LESS THAN 300
 OTHERWISE COMMENTS 6A & 6B WOULD REMAIN.
 2 SHEET S.001:
 2A) PLEASE PROVIDE A DIGITAL SOILS REPORT BY UNIVERSAL
 ENGINEERING SCIENCES DATED FEB. 07TH/ 2022. AS STATED
 ON PLAN: THE GEOTECHNICAL INVESTIGATION REPORT
 RECOMMENDATIONS SHALL SUPERSEDE THE MINIMUM CRITERIA
 STATED IN THE STRUCTURAL GENERAL NOTES.
  
 2B) SLAB-ON-GROUND HEADING NOR THE 12 STATEMENTS
 DEALING WITH SLAB ON GROUND INDICATE COMPLIANCE WITH
 TERMITE PROTECTION FOUND IN 1816.1 OF THE 2020
 FBC-BUILDING CODE.
  
 3) BUILDING PROVISO: SHEET S.002 HAS HEADING DEALING
 WITH WELDING & STRUCTURAL STEEL FOR THE PROJECT. WELDED
 OR BOLTED CONNECTIONS. THIS BUILDING CONTAINS EITHER
 BOLTED AND OR WELDED CONNECTIONS. THE CONTRACTOR IS
 REQUIRED TO PROVIDE WELD PROCEDURE SPECIFICATIONS &
 WELDER OPERATOR PERFORMANCE QUALIFICATION RECORDS IN
 ACCORDANCE WITH THE REFERENCED STANDARDS AT TIME OF
 INSPECTION FOR FIELD WIELDING, ON THE JOB-SITE
 WIELDING. THIRD PARTY CERTIFICATION WILL BE REQUIRED.
 THE OWNER MAY JUST HIRE A 3RD PARTY ENGINEERING FIRM TO
 COMPLETE AND APPROVE THE FORMER INSPECTIONS. REPORTS
 SUBMITTED TO BUILDING INSPECTOR AT TIME OF FRAMING
 INSPECTION.
 2020 FBC-B 2204.1 WELDING
 1. WELD PROCEDURES SPECIFICATIONS
 2. QUALIFICATIONS OF WELDING PERSONAL
 2017 FBC-B 2204.2 BOLTING.
 IF FURTHER CLARIFICATION AND OR QUESTIONS IS REQUIRED,
 PLEASE CONTACT THE CHIEF BUILDING INSPECTOR RICHARD
 BRUNELLE AT 561-805-6670.
  
 4) BUILDING PROVISO/ DEFERRED SUBMITTALS/ COMPONENTS &
 CLADDING.
 COMPONENTS & CLADDING. PLEASE SUBMIT THE COMPONENTS AND
 CLADDING PRODUCT APPROVALS. 2020 FBC-B 1609.1.2
 PROTECTION OF OPENINGS, 1609.6.4.4.1 COMPONENTS &
 CLADDING. FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS,
 ADMINISTRATIVE CODE 61G20-3.005, RULE 9N-3 NOV. 01/
 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION
 SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS:
 (31)(A) EXTERIOR DOORS, MULLIONS & ROOF HATCHES.
 (B) WINDOWS & MULLIONS
 (C) PANEL WALLS: STOREFRONTS, CURTAIN WALLS, WALL
 LOUVERS, EFIS SYSTEMS,
 (D) ROOFING PRODUCTS AND ASSEMBLIES, LIGHTWEIGHT
 CONCRETE INSULATION, ROOF TOP VENTILATORS
 (G) PRE-ENGINEERED A/C STANDS
  
 4A) W. P. B. 107.3.4. PRODUCT APPROVALS. THOSE PRODUCTS
 WHICH ARE REGULATED BY FLORIDA ADMINISTRATIVE CODE RULE
 61G20 SHALL BE REVIEWED AND APPROVED IN WRITING (SHOP
 DRAWING STAMP OF APPROVAL) BY THE DESIGNER OF RECORD
 PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL.
 FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR
 SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS,
 SHOP DRAWINGS ETC.
  
 4B) DELEGATED ENGINEERING. 61G15-30.003 ENGINEERING
 DOCUMENT CLASSIFICATION. FL 61G-15-30.006 (3) THE
 DELEGATED ENGINEER SHALL FORWARD THE DELEGATED
 ENGINEERING DOCUMENTS TO THE ENGINEER OF RECORD FOR
 REVIEW.
  
 4C) IDENTIFY GLAZING/ MULLIONS. PLEASE IDENTIFY IN THE
 PRODUCT APPROVAL BEFORE SUBMITTING TO DESIGNER OF
 RECORD AND BEFORE SUBMISSION TO THE BUILDING
 DEPARTMENT. FOR ALL PRODUCTS WITH GLAZING, PLEASE
 IDENTIFY THE OPENING WIDTH & HEIGHT, SILL HEIGTH, TYPE
 OF GLAZING, MULLION SIZE, LENGTH IF UNREINFORCED OR
 REINFORCED INFORMATION IF REQUIRED, ATTACHMENTS AND
 ASSOCIATE PRESSURES FOR EACH OPENING SIZE. 2020 FBC-B
 1405.13.1 INSTALLATION. WINDOWS AND DOORS SHALL BE
 INSTALLED IN ACCORDANCE WITH APPROVED MANUFACTURER???S
 INSTRUCTIONS. FASTENER SIZE AND SPACING SHALL BE
 PROVIDED IN SUCH INSTRUCTIONS AND SHALL BE CALCULATED
 BASED ON MAXIMUM LOADS AND SPACING USED IN THE TESTS.
  
 4D) 2020 FBC-BUILDING CODE SECTION 1405.4. FLASHINGS
 SHALL BE INSTALLED AT THE PERIMETERS OF EXTERIOR DOORS
 & WINDOW ASSEMBLIES. WHEN SELF-ADHERED MEMBRANES ARE
 USED AS FLASHINGS IN WALL ASSEMBLIES, THOSE
 SELF-ADHERED FLASHINGS SHALL COMPLY WITH AAMA-711.
 4E) ROOFING: FOR ALL ROOFING PRODUCTS PLEASE IDENTIFY
 ALL ROOFING SUB-SYSTEMS AND THEIR ASSOCIATED PRESSURES
 FOR ROOF ZONE # 1. REVIEW THE PRODUCT APPROVAL
 LIMITATIONS, IF ENHANCED FASTENING IS ALLOWED FOR ROOF
 ZONES 2 & 3. FASTENER DENSITIES SHALL BE INCREASED FOR
 BOTH INSULATION & THE BASE SHEET AS CALCULATED IN
 COMPLIANCE WITH ROOFING APPLICATION STANDARDS RAS 117.
 CALCULATION PREPARED, SIGNED AND
 SEALED BY A FLORIDA REGISTERED PROFESSIONAL ENGINEER OR
 REGISTERED ARCHITECT. 1609.6.4.4.1 COMPONENTS &
 CLADDING.
  
 5) NOTE ONLY. I???VE HEARD IN TALKING WITH SUPERVISORS
 THAT THE PATIO AREA MAY IN THE FUTURE COME IN UNDER A
 SEPARATE PERMIT TO COVER THIS AREA. SINCE THIS IS A
 LARGE AREA PLEASE REVIEW SECTION 3105.3.2 2020
 FBC-BUILDING CODE DEALING WITH FABRIC AWNINGS OR
 FABRIC-COVERED FRAMES SHALL NOT EXCEED THE AREA OF THE
 BUILDING TO WHICH IT IS ATTACHED.
  
 6A) THE TITLE SHEET LIST THE OCCUPANT LOAD AS 381.
 SHEET S.001 INDICATES THE BUILDING RISK CATEGORY AS II
 AND WIND SPEED OF 170 VULT. PLEASE REVIEW THE 2020
 FBC-BUILDING CODE TABLE 1604.5. WHEN OCCUPANT LOAD IS
 GREATER THAN 300, THIS BUILDING RISK CATEGORY INCREASES
 FROM II TO III WITH INCREASED WIND DESIGN (180 VULT)
 AND ASSOCIATED PRESSURES. SEE TABLE 1604.5.
  
 6B) SHEET S.003 COMPONENTS AND CLADDING EXTERNAL
 PRESSURES IN VASD THE PRESSURES WILL INCREASE SINCE THE
 VULT WIND SPEED INCREASES TO 180 VULT. PLEASE KEEP THE
 PRESSURES IN VASD, THE SAME AS PRODUCT APPROVALS. THANK
 YOU.
  
 7A) THE LS.100 LIFE SAFETY SHEET A.101 PLEASE SHOW
 WHICH EXITS ARE GOING TO BE THE ACCESSIBLE EXITS ABLE
 TO GET THE OCCUPANTS TO THE PUBLIC WAY. 2017 FBC-B
 1007.1.1. TWO EXITS OR EXIT ACCESS DOORWAYS. WHERE 2
 EXIT OR EXIT ACCESS DOORWAYS ARE REQUIRED FROM ANY
 PORTION OF THE EXIT ACCESS, THEY SHALL BE PLACED A
 DISTANCE APART EQUAL TO NOT LESS THAN ?? THE OVERALL
 MAXIMUM OVERALL DIAGONAL DIMENSION OF THE BUILDING OR
 AREA TO BE SERVED MEASURED IN A STRAIGHT LINE BETWEEN
 THEM.
 EXCEPTION BUILDINGS EQUIPPED THROUGHOUT WITH AN
 AUTOMATIC SPRINKLER SYSTEM IN ACCORDANCE WITH SECTION
 903.3.1.1 OR 903.3.1.2, THE SEPARATION DISTANCE SHALL
 NOT BE LESS THAN 1/3RD OVERALL DIAGONAL DIMENSION OF
 THE BUILDING OR AREA TO BE SERVED MEASURED IN A
 STRAIGHT LINE BETWEEN THEM.
 2020 FBC-ACCESSIBILITY CODE SECTION 207.1 MEANS OF
 EGRESS SHALL COMPLY WITH SECTION 1003.2.13 OF THE
 INTERNATIONAL BUILDING CODE (2000 EDITION AND 2001
 SUPPLEMENT) OR SECTION 1007 OF THE INTERNATIONAL
 BUILDING CODE (2003 EDITION). 2003 IBC-B 1007.1 WHERE
 MORE THAN ONE MEANS OF EGRESS IS REQUIRED BY SECTIONS
 1014.1 OR 1018.1 FROM ANY ACCESSIBLE SPACE, EACH
 ACCESSIBLE PORTION OF THE SPACE SHALL BE SERVED BY NOT
 LESS THAN TWO MEANS OF EGRESS.
  
 7B) 2020 FBC-ACCESS. CODE CHANGES IN LEVEL 303.2 AND
 303.3. WHERE CHANGES IN LEVEL ARE PERMITTED IN THE
 FLOOR OR GROUND SURFACES, THEY SHALL COMPLY WITH
 SECTION 303. SEE 303.1 & 303.2.
  
 7C) 2020 FBC-ACCESS. CODE 404.2.5. THRESHOLDS.
 THRESHOLDS, IF PROVIDED AT DOORWAYS, SHALL BE ?? INCH
 HIGH MAXIMUM. RAISED THRESHOLDS AND CHANGES IN LEVEL AT
 DOORWAYS SHALL COMPLY WITH 302 & 303.
 8) CLOSING WHEN RESUBMITTING PLANS PLEASE INDICATE THE
 REVISION & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES
 AS NECESSARY.
  
 A TRANSMITTAL LETTER / NARRATIVE LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS
 REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT
 REVIEW CYCLE.
 PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS
 REVIEW, SUBSEQUENT
 REMARKS MAYBE MADE IN THE NEXT REVIEW CYCLE.
  
  
 MY WORK HOURS ARE USUALLY TUES. & WED. 7:30 AM- 4:30 PM
 PART-TIME/ SEMI-RETIRED.
  
 IF YOU WISH TO SPEAK WITH A PLANS EXAMINER BEFORE I GET
 BACK INTO THE OFFICE CALL
 (561)805-6700 AND ASK FOR THE PLANS EXAMINER ON-CALL.
 THANK YOU.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2023-07-13 Cont ID  
Sent By mpeterso Date 2023-07-13 Time 14:18 Rev Time 0.00
Received By mpeterso Date 2023-07-13 Time 14:15 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2023-05-12 Cont ID  
Sent By jleahy Date 2023-05-12 Time 14:37 Rev Time 0.00
Received By jleahy Date 2023-05-12 Time 10:09 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2023-02-07 Cont ID  
Sent By mpeterso Date 2023-02-07 Time 12:33 Rev Time 0.00
Received By mpeterso Date 2023-02-07 Time 11:02 Sent To  
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 3 Status P Date 2023-07-13 Cont ID  
Sent By cseifer Date 2023-07-13 Time 08:26 Rev Time 0.00
Received By cseifer Date 2023-07-13 Time 08:26 Sent To  
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 2 Status P Date 2023-05-09 Cont ID  
Sent By lquinone Date 2023-05-09 Time 11:27 Rev Time 0.00
Received By lquinone Date 2023-05-09 Time 11:27 Sent To  
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 1 Status P Date 2023-02-13 Cont ID  
Sent By rrossano Date 2023-02-13 Time   Rev Time 0.00
Received By rrossano Date 2023-02-13 Time   Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2023-07-10 Cont ID  
Sent By pleduc Date 2023-07-10 Time   Rev Time 0.00
Received By pleduc Date 2023-07-10 Time 14:20 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2023-05-04 Cont ID  
Sent By pleduc Date 2023-05-04 Time   Rev Time 0.00
Received By pleduc Date 2023-05-04 Time 10:25 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2023-02-03 Cont ID  
Sent By pleduc Date 2023-02-03 Time   Rev Time 0.00
Received By pleduc Date 2023-02-03 Time 11:51 Sent To  
Notes
2023-02-03 12:02:50THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 1) THERE ARE REAR EXITS INDICATED ON THE LIFE SAFETY
 PLANS,
  
 PER NFPA 101, CH 12 NEW ASSEMBLY, 38 NEW BUSINESS, & CH
 7 MEANS OF EGRESS.
  
 7.7 DISCHARGE FROM EXITS
 7.7.1* EXIT TERMINATION. EXITS SHALL TERMINATE
 DIRECTLY, AT A PUBLIC
 WAY OR AT AN EXTERIOR EXIT DISCHARGE, UNLESS OTHERWISE
 PROVIDED IN 7.7.1.2
 THROUGH 7.7.1.4.
  
 THERE MAY BE A SERVICE ROAD NEXT TO THE RR, HOWEVER, I
 BELIEVE A FENCE IS BEING PROPOSED THAT MAY
 LIMIT/RESTRICT PASSAGE IN EITHER DIRECTION.
  
 THERE MAY ALSO BE GATES ALONG THIS FENCE THAT NEEDS TO
 BE ACCESSIBLE.
  
 AN ADDITIONAL CONCERN IS THAT THERE MAY BE UNPROTECTED
 OPENINGS ALONG ALL THE VARIOUS OCCUPANCIES ALONG THE
 FENCE LINE THAT COULD EXPOSE PEDESTRIANS TO THE EFFECTS
 OF FIRE AND SMOKE.
  
  
 PLEASE PROVIDE DETAILS IN COMPLIANCE WITH THE REQUIRED
 CODE.
  
  
  
 2) THERE ARE INDICATIONS WITHIN THE DOOR SCHEDULE THAT
 DO NOT APPEAR TO MEET THE NFPA 101 CH 7, MEANS OF
 EGRESS & CH 12 NEW ASSEMBLY REQUIREMENTS FOR ASSEMBLY
 OCCUPANCIES.
  
 7.2.1.7* PANIC HARDWARE AND FIRE EXIT HARDWARE.
  
 7.2.1.7.1 WHERE A SIDE-HINGED OR PIVOTED-SWINGING DOOR
 ASSEMBLY IS
 REQUIRED TO BE EQUIPPED WITH PANIC OR FIRE EXIT
 HARDWARE, SUCH HARDWARE
 SHALL MEET ALL OF THE FOLLOWING CRITERIA:
 (1) IT SHALL CONSIST OF A CROSS BAR OR A PUSH PAD, WITH
 THE LENGTH OF THE
 ACTUATING PORTION OF THE CROSS BAR OR PUSH PAD NOT LESS
 THAN ONE-HALF
 OF THE WIDTH OF THE DOOR LEAF.
 (2) IT SHALL BE MOUNTED AS FOLLOWS:
 (A) NEW INSTALLATIONS SHALL BE NOT LESS THAN 34 IN.
 (865 MM), AND
 NOT MORE THAN 48 IN. (1220 MM), ABOVE THE FLOOR.
 (B) EXISTING INSTALLATIONS SHALL BE NOT LESS THAN 30
 IN. (760 MM),
 AND NOT MORE THAN 48 IN. (1220 MM), ABOVE THE FLOOR.
 (3) IT SHALL BE CONSTRUCTED SO THAT A HORIZONTAL FORCE
 NOT TO EXCEED 15 LBF
 (66 N) ACTUATES THE CROSS BAR OR PUSH PAD AND LATCHES
  
 7.2.1.7.3 REQUIRED PANIC HARDWARE AND FIRE EXIT
 HARDWARE, IN OTHER THAN
 DETENTION AND CORRECTIONAL OCCUPANCIES AS OTHERWISE
 PROVIDED IN CHAP TERS 22 AND 23, SHALL NOT BE EQUIPPED
 WITH ANY LOCKING DEVICE, SET SCREW,
 OR OTHER ARRANGEMENT THAT PREVENTS THE RELEASE OF THE
 LATCH WHEN PRESSURE
 IS APPLIED TO THE RELEASING DEVICE
  
 12.2.2.2 DOORS.
 12.2.2.2.1 DOORS COMPLYING WITH 7.2.1 SHALL BE
 PERMITTED
  
 12.2.2.2.3 ANY DOOR IN A REQUIRED MEANS OF EGRESS FROM
 AN AREA HAVING
 AN OCCUPANT LOAD OF 100 OR MORE PERSONS SHALL BE
 PERMITTED TO BE PRO VIDED WITH A LATCH OR LOCK ONLY IF
 THE LATCH OR LOCK IS PANIC HARDWARE OR
 FIRE EXIT HARDWARE COMPLYING WITH 7.2.1.7, UNLESS
 OTHERWISE PERMITTED
 BY ONE OF THE FOLLOWING:
 (1) THIS REQUIREMENT SHALL NOT APPLY TO DELAYED-EGRESS
 ELECTRICAL LOCK ING SYSTEMS AS PERMITTED IN 12.2.2.2.5.
 (2) THIS REQUIREMENT SHALL NOT APPLY TO SENSOR-RELEASE
 OF ELECTRICAL
 LOCKING SYSTEMS AS PERMITTED IN 12.2.2.2.6
  
 12.2.2.2.4 LOCKING DEVICES COMPLYING WITH 7.2.1.5.5
 SHALL BE PERMITTED
 TO BE USED ON A SINGLE DOOR OR A SINGLE PAIR OF DOORS
 IF BOTH OF THE FOL LOWING CONDITIONS APPLY:
 (1) THE DOOR OR PAIR OF DOORS SERVE AS THE MAIN EXIT
 AND THE ASSEMBLY
 OCCUPANCY HAS AN OCCUPANT LOAD NOT GREATER THAN 500.
 (2) ANY LATCHING DEVICES ON SUCH A DOOR(S) FROM AN
 ASSEMBLY OCCU PANCY HAVING AN OCCUPANT LOAD OF 100 OR
 MORE ARE RELEASED BY
 PANIC HARDWARE OR FIRE EXIT HARDWARE.
  
 3) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET
 REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE
 ABOVE.
  
  
 4) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE
 RE-SUBMITTAL OF THE ABOVE. DELINEATE
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop G GAS REVIEW
Rev No 2 Status N Date 2023-05-09 Cont ID  
Sent By ccole Date 2023-05-09 Time 11:30 Rev Time 0.00
Received By ccole Date 2023-05-09 Time 10:44 Sent To  
Notes
2023-05-09 11:31:58GAS SHALL BE UNDER SEPARATE PERMIT PER ARCHITECT'S
 REQUEST.

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2023-02-06 Cont ID  
Sent By ccole Date 2023-02-06 Time 17:22 Rev Time 0.00
Received By ccole Date 2023-02-03 Time 17:22 Sent To  
Notes
2023-02-06 17:23:591ST REVIEW FBC-2020 FUEL GAS
 PERMIT- 2301480
 2/3/23
  
 CODES IN EFFECT:
 FBC P- FLORIDA FUEL GAS CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET P-100 & P-500: THE PLANS INDICATE NEW GAS
 METERS AND SERVICES FOR FUTURE TENANTS 101 & 104.
 PLEASE PROVIDE GAS RISERS PER SEC. 107.3.5.1.5 WPB. THE
 GAS RISER DRAWINGS ARE NOT REQUIRED TO BE COMPLETE AT
 THIS TIME BUT SHALL INCLUDE THE FOLLOWING INFORMATION
 PER CHAPTER 4 FBC FG.
 A) DELIVERY PRESSURES AT THE METER.
 B) ESTIMATED TOTAL BTU LOADS.
 C) TYPES AND SIZES OF PIPING.
 D) BRANCH AND CUT PIPE LENGTH MEASUREMENTS.
 E) LOCATIONS OF SHUTOFF VALVES AND GAS TIGHT CAPS.
 F) PIPE SIZING TABLES.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By amcgrego Date 2023-07-05 Time 08:23 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2023-05-31 Cont ID  
Sent By pvalenti Date 2023-05-31 Time 18:11 Rev Time 0.00
Received By pvalenti Date 2023-05-02 Time 09:16 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2023-03-10 Cont ID  
Sent By aoliver Date 2023-03-10 Time 07:11 Rev Time 0.00
Received By aoliver Date 2023-02-02 Time 09:45 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2023-02-22 Cont ID  
Sent By jwitmer Date 2023-02-22 Time 09:47 Rev Time 0.00
Received By jwitmer Date 2023-02-22 Time 09:47 Sent To  
Notes
2023-02-22 09:47:34IMPACT FEES - DIGITAL SUBMITTALS:
 PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECT DOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON
 APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE RECEIPT TO
 YOUR PROJECT OR EMAIL IT TO [email protected].
  

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2023-07-17 Cont ID  
Sent By jbaker Date 2023-07-17 Time 12:17 Rev Time 0.00
Received By jbaker Date 2023-07-17 Time 12:13 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2023-05-09 Cont ID  
Sent By medwards Date 2023-05-09 Time 09:24 Rev Time 0.00
Received By medwards Date 2023-05-09 Time 09:24 Sent To  
Notes
2023-05-09 09:27:09APPROVED: SHELL ONLY FOR 809 N RAILROAD AVE. ME

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2023-02-07 Cont ID  
Sent By medwards Date 2023-02-07 Time 05:50 Rev Time 0.00
Received By medwards Date 2023-02-07 Time 05:50 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status P Date 2023-07-07 Cont ID  
Sent By ccole Date 2023-07-07 Time 11:16 Rev Time 0.00
Received By ccole Date 2023-07-07 Time 10:18 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2023-05-09 Cont ID  
Sent By ccole Date 2023-05-09 Time 11:32 Rev Time 0.00
Received By ccole Date 2023-05-09 Time 10:44 Sent To  
Notes
2023-05-09 11:39:432ND REVIEW FBC-2020 PLUMBING
 PERMIT- 23011480
 5/9/23
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED. COMMENT #1 FROM THE 1ST
 REVIEW PRINTED BELOW STILL EXISTS. THE ARCHITECT'S
 COMMENT RESPONSE NARRATIVE STATES THE BACKFLOW AND
 GREASE INTERCEPTOR ARE INLCLUDED IN A STREET
 IMPROVEMENT PERMIT HOWEVER AS STATED BELOW SEPARATE
 BUILDING DEPARTMENT PERMITS ARE REQUIRED.
  
 1) SHEET P-100: PLEASE NOTE SEPARATE PERMITS ARE
 REQUIRED FOR THE POTABLE WATER SERVICE BACKFLOW
 PREVENTER AND THE GREASE INTERCEPTOR AND THE PERMIT
 APPLICATIONS FOR THOSE ITEMS SHALL BE SUBMITTED PRIOR
 TO PLUMBING PLAN APPROVAL FOR THIS PERMIT. YOU CAN
 SUBMIT APPLICATIONS TBD (TO BE DETERMINED) IF YOU DO
 NOT HAVE CONTRACTORS SELECTED BY EMAILING A COMPLETED
 PERMIT APPLICATION TO [email protected]. YOU WILL
 RECEIVE INSTRUCTIONS TO PAY FEES AND UPLOAD PLANS. YOU
 MAY UPLOAD PLANS AND PAY FEES AT A FUTURE DATE, BUT THE
 APPLICATIONS ARE REQUIRED AT THIS TIME. WE RECOMMEND
 THAT YOU PAY FEES AND UPLOAD PLANS AT THE SAME TIME.
 AFTER YOU HAVE THE PERMIT GENERATED, NOTIFY ME VIA
 EMAIL AND I WILL CHANGE THE REVIEW STATUS TO PASS.
  
 NEW COMMENT BASED ON RESUBMITTED PLANS.
  
 1) SHEETS P-100, P- 700: SHOW A CLEANOUT WILL BE
 INSTALLED AT THE JUNCTION OF THE BUILING SANITARY DRAIN
 AND SEWER LINE.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2023-02-06 Cont ID  
Sent By ccole Date 2023-02-06 Time 07:21 Rev Time 0.00
Received By ccole Date 2023-02-03 Time 16:23 Sent To  
Notes
2023-02-06 07:22:261ST REVIEW FBC-2020 PLUMBING
 PERMIT- 23011480
 2/6/23
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET P-100: PLEASE NOTE SEPARATE PERMITS ARE
 REQUIRED FOR THE POTABLE WATER SERVICE BACKFLOW
 PREVENTERS AND THE GREASE INTERCEPTORS FOR FUTURE
 TENANT SPACES 101 & 104 AND THE PERMIT APPLICATIONS FOR
 THOSE ITEMS SHALL BE SUBMITTED PRIOR TO PLUMBING PLAN
 APPROVAL FOR THIS PERMIT. YOU CAN SUBMIT APPLICATIONS
 TBD (TO BE DETERMINED) IF YOU DO NOT HAVE CONTRACTORS
 SELECTED BY EMAILING A COMPLETED PERMIT APPLICATION TO
 [email protected]. YOU WILL RECEIVE INSTRUCTIONS
 TO PAY FEES AND UPLOAD PLANS. YOU MAY UPLOAD PLANS AND
 PAY FEES AT A FUTURE DATE, BUT THE APPLICATIONS ARE
 REQUIRED AT THIS TIME. WE RECOMMEND THAT YOU PAY FEES
 AND UPLOAD PLANS AT THE SAME TIME. AFTER YOU HAVE THE
 PERMIT GENERATED, NOTIFY ME VIA EMAIL AND I WILL CHANGE
 THE REVIEW STATUS TO PASS.
  
 2) P-100: NOTES 4, 5, 9, 10, & 11 REFER TO CIVIL PLANS
 WHICH ARE NOT INCLUDED IN THE PLAN SET. PLEASE PROVIDE
 THE PLANS- SEC. 107.2.1 WPB. THE CURRENT PLANS SHOW THE
 STORM, SANITARY, AND GREASE WASTE LINES TERMINATING IN
 THE CENTER PATIO SPACE.
  
 3) P-101: PLEASE LABEL ROOF AREA 2 LOCATION. THE PLAN
 SHOWS AREA 1 ONLY- SEC. 107.2.1 WPB.
  
 4) P-101 & P-701: PLEASE SHOW THE ROOF GUTTER AND
 DOWNSPOUT SIZES ON P-101 AND THE DOWNSPOUT SIZES ON THE
 RISER DRAWING- TABLES 1106.3 & 1106.6 FBC P.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
2023-07-07 11:26:37PLUMBING SIGNATURES PASSED.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2023-05-12 Cont ID  
Sent By jleahy Date 2023-05-12 Time 14:42 Rev Time 0.00
Received By jleahy Date 2023-05-12 Time 14:42 Sent To  
Notes
2023-05-09 11:58:18PLUMBING DIG/SIGS PASSED.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2023-02-07 Cont ID  
Sent By mpeterso Date 2023-02-07 Time 12:38 Rev Time 0.00
Received By mpeterso Date 2023-02-07 Time 12:38 Sent To  
Notes
2023-02-07 12:39:04ALL PLANS PASSED SIGNATURE. MP
2023-02-07 05:51:35MECHANICAL DIGITAL SIGNATURES APPROVED ME
2023-02-06 17:11:40PLUMBING PLANS PASSED.

Review Stop Z ZONING
Rev No 3 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2023-05-30 Cont ID  
Sent By ckimmerl Date 2023-05-30 Time 09:20 Rev Time 0.00
Received By ckimmerl Date 2023-05-30 Time 09:20 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2023-03-09 Cont ID  
Sent By CKimmerl Date 2023-03-09 Time 15:39 Rev Time 0.00
Received By ckimmerl Date 2023-03-09 Time 15:39 Sent To  
Notes
2023-03-09 15:39:20SCOPE OF PROJECT DEMONSTRATES SUBSTANTIAL CHANGE IN
 STRUCTURE AND TRIGGERS THE PROVISIONS OF ARTICLE IV -
 SEC. 94-124 AND THE NONCOMFORMITIES SECTION OF ARTICLE
 XVI SEC. 94-515.
 THIS IS AN ALTERATION OR DEMOLITION WITH CONSTRUCTION
 OF 'NEW' STRUCTURE, THE NEW MUST BE BUILT IN COMPLIANCE
 WITH CODE PROVISIONS OF THE NORA -5 DISTRICT.
  
 1. PLEASE PROVIDE A SITE SURVEY.
  
 2. PLEASE PROVIDE A SITE PLAN WITH SETBACKS ILLUSTRATED
 AND PROVIDE TABULAR DATA OR CALCULATIONS FOR NORA-5
 STANDARDS. RENOVATION AND ALTERATION MUST MEET
 SETBACKS, HEIGHT, BUILDING FOOTPRINT, ETC. FOR
 SUBDISTRICT.
  
  
 CHRIS KIMMERLY, AICP
 URBAN DESIGN PLANNER
 822-1426 [email protected]
  