Plan Review Details - Permit 23011265
Plan Review Stops For Permit 23011265
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2023-03-24 Cont ID  
Sent By rmcphers Date 2023-03-24 Time 09:21 Rev Time 0.00
Received By rmcphers Date 2023-03-24 Time 09:21 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2023-02-17 Cont ID  
Sent By rmcphers Date 2023-02-17 Time 10:33 Rev Time 0.00
Received By rmcphers Date 2023-02-17 Time 10:33 Sent To  
Notes
2023-02-17 10:40:35REMODEL/ALTERATION
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
  
 1) SIDING IS SUBJECT TO WIND LOADS - PLEASE SHOW SIDING
 TYPE AND ATTACHMENTS OR PROVIDE A PRODUCT APPROVAL -
 FBC R703.1.2
  
 2) PLEASE SHOW THE SMOKE DETECTOR LOCATIONS - FBC
 R314.2.2 ALTERATIONS, REPAIRS AND ADDITIONS.
 WHERE ALTERATIONS, REPAIRS OR ADDITIONS REQUIRING A
 PERMIT OCCUR, OR WHERE ONE OR MORE SLEEPING ROOMS ARE
 ADDED OR CREATED IN EXISTING DWELLINGS, THE INDIVIDUAL
 DWELLING UNIT SHALL BE EQUIPPED WITH SMOKE ALARMS
 LOCATED AS REQUIRED FOR NEW DWELLINGS.

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2023-03-28 Cont ID  
Sent By rperdomo Date 2023-03-28 Time 15:04 Rev Time 0.00
Received By rperdomo Date 2023-03-28 Time 14:44 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2023-02-02 Cont ID  
Sent By rperdomo Date 2023-02-02 Time 12:10 Rev Time 0.00
Received By rperdomo Date 2023-02-02 Time 11:21 Sent To  
Notes
2023-02-02 12:10:35FLORIDA BUILDING CODE 2020 7TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED
 NFPA 70 2017 EDITION
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW
  
 1. PROVIDE INFORMATION OF THE ELECTRICAL PANEL (PANEL
 SCHEDULE), NEW LIGHTING BRANCH CIRCUITS, 240 V EV
 CHARGER OUTLET BRACH CIRCUIT. THIS INFORMATION SHALL
 INCLUDE CONDUCTORS SIZE AND PROTECTION. NEC 220, 240,
 250, 408.4(A)
  
 END OF COMMENTS
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
 RUBEN PEREZ PERDOMO, P.E.
 ELECTRICAL PLANS EXAMINER
 561-805-6738
 [email protected]
  

Review Stop G GAS REVIEW
Rev No 3 Status N Date 2023-04-07 Cont ID  
Sent By ccole Date 2023-04-07 Time 10:32 Rev Time 0.00
Received By ccole Date 2023-04-07 Time 10:32 Sent To  
Notes
2023-04-07 10:33:29CONTRACTOR HAS SENT AN EMAIL REQUEST FOR GAS TO BE
 UNDER A SEPARATE PERMIT,

Review Stop G GAS REVIEW
Rev No 2 Status F Date 2023-03-24 Cont ID  
Sent By ccole Date 2023-03-24 Time 10:53 Rev Time 0.00
Received By ccole Date 2023-03-24 Time 09:55 Sent To  
Notes
2023-03-24 10:54:10 
 2ND REVIEW FBC-2020 RES. GAS
 PERMIT- 23011265
 3/23/2023
  
 CODES IN EFFECT:
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION
 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET S1.0: THE GAS RISER IS INCOMPLETE. PROVIDE THE
 PRESSURE AT THE METER- 2PSI OR 11-INCHES W.C.?
 BASED ON THE LOW PRESSURE TABLE G2413.4(3) FBC RES THE
 ??-INCH COPPER FOR A SYSTEM WITH A 35 FT. TOTAL
 DEVELOPED LENGTH IS LIMITED TO MAXIMUM SUPPLY OF
 131,000 BTU. THE PIPE SHALL BE INCREASED TO 1-INCH FROM
 THE METER TO THE WATER HEATER RISER CONNECTION POINT.
 A) PLEASE LABEL THE PIPING AS UNDERGROUND OR
 ABOVEGROUND- SEC. 107.2.1 WPB.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
  

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2023-01-30 Cont ID  
Sent By ccole Date 2023-01-30 Time 08:16 Rev Time 0.00
Received By ccole Date 2023-01-30 Time 08:05 Sent To  
Notes
2023-01-30 08:17:32 
 1ST REVIEW FBC-2020 RES. GAS
 PERMIT- 23011265
 1/30/2023
  
 CODES IN EFFECT:
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION
 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET A1.0: SUBMIT A GAS PIPING RISER FOR
 INSTALLATION OF THE NEW TANKLESS WATER HEATER- SEC.
 107.3.5.3 WPB. THE RISER SHALL SHOW THE NEW GAS PIPING
 TO THE WATER HEATER AND ALL EXISTING GAS PIPING AND
 APPLIANCES AT THE RESIDENCE- SECTION G2412.3 & G2412.4
 FBC RES. REFER TO FBC RES. CHAPTER 24 FUEL GAS AND
 PROVIDE THE FOLLOWING INFORMATION ON THE DRAWING-
 A) TYPE OF GAS- NATURAL OR LP.
 B) DELIVERY PRESSURE AT THE METER.
 C) TOTAL BTU LOAD AND INDIVIDUAL APPLIANCE BTU LOADS.
 D) TYPES AND SIZES OF PIPING.
 E) TOTAL DEVELOPED LENGTH OF THE SYSTEM FROM THE METER
 TO THE MOST REMOTE APPLIANCE OUTLET.
 F) BRANCH AND CUT PIPE LENGTH MEASUREMENTS.
 G) LOCATIONS OF REGULATORS, SHUTOFF VALVES.
 H) OUTLET PRESSURES AT REGULATORS.
 I) LOCATIONS AND TYPES OF PIPE SLEEVES.
 K) PIPE SIZING TABLES.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop HIST HISTORICAL
Rev No 2 Status P Date 2023-04-06 Cont ID  
Sent By amhamilt Date 2023-04-06 Time 14:24 Rev Time 0.00
Received By amhamilt Date 2023-04-06 Time 14:24 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2023-02-13 Cont ID  
Sent By amhamilt Date 2023-02-13 Time 10:01 Rev Time 0.00
Received By amhamilt Date 2023-02-13 Time 10:01 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2023-04-07 Cont ID  
Sent By aoliver Date 2023-04-07 Time 07:46 Rev Time 0.00
Received By aoliver Date 2023-03-23 Time 07:22 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2023-02-17 Cont ID  
Sent By rmcphers Date 2023-02-17 Time 10:42 Rev Time 0.00
Received By rmcphers Date 2023-01-27 Time 13:03 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2023-03-24 Cont ID  
Sent By ccole Date 2023-03-24 Time 10:05 Rev Time 0.00
Received By ccole Date 2023-03-24 Time 09:55 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2023-01-30 Cont ID  
Sent By ccole Date 2023-01-30 Time 07:53 Rev Time 0.00
Received By ccole Date 2023-01-30 Time 07:36 Sent To  
Notes
2023-01-30 07:56:351ST REVIEW FBC-2020 RES. PLUMBING
 PERMIT- 23011265
 1/30/23
  
 CODES IN EFFECT:
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION
 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) THE SANITARY ISOMETRIC SHOWN ON THE S1.0 PLAN SHEET
 CANNOT BE APPROVED BECAUSE THE SHEET DOES NOT BEAR A
 VERIFIABLE DIGITAL SIGNATURE AND SEAL BY THE ARCHITECT
 OF RECORD- FL. STATUTE 481.221 AND SEC. 61G1-16.005
 FAC.
 THE DIGITAL IMPRINT ON THE PLAN APPEARS TO BE A COPY
 OIF THE ORIGINAL.
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2023-03-24 Cont ID  
Sent By rmcphers Date 2023-03-24 Time 09:24 Rev Time 0.00
Received By rmcphers Date 2023-03-24 Time 09:24 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2023-02-17 Cont ID  
Sent By rmcphers Date 2023-02-17 Time 10:40 Rev Time 0.00
Received By rmcphers Date 2023-02-17 Time 10:40 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2023-03-24 Cont ID  
Sent By rmcphers Date 2023-03-24 Time 09:24 Rev Time 0.00
Received By rmcphers Date 2023-03-24 Time 09:24 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2023-01-30 Cont ID  
Sent By ccole Date 2023-01-30 Time 07:56 Rev Time 0.00
Received By ccole Date 2023-01-30 Time 07:56 Sent To  
Notes
2023-01-30 08:05:13DIGITAL SIGNATURE REVIEW
 PERMIT- 23011265
 1/30/2023
  
 CODES IN EFFECT:
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION
 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEETS C1, D1.0, A1.0, A1.1, S1.0, & E1.0 ARE NOT
 DIGITALLY SIGNED AND SEALED BY THE ARCHITECT OF RECORD-
 FL. STATUTE 481.221 AND SEC. 61G1-16.005 FAC.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved