Plan Review Stops For Permit 23011162 |
Review Stop |
AD |
ADDRESSING |
Rev No |
2 |
Status |
P |
Date |
2023-05-17 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2023-05-17 |
Time |
12:47 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2023-05-17 |
Time |
12:47 |
Sent To |
|
|
Notes |
2023-05-17 12:47:48 | PARCEL UPDATED 1005 AND 1015 N RAILROAD AVE |
|
|
Review Stop |
AD |
ADDRESSING |
Rev No |
1 |
Status |
F |
Date |
2023-02-03 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2023-02-03 |
Time |
13:40 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2023-02-03 |
Time |
13:40 |
Sent To |
|
|
Notes |
2023-02-03 13:43:37 | THIS PARCEL CURRENTLY HAS TWO ADDRESSES 925 N RAILROAD | | AVE AND 1003 N RAILROAD AVE, I ALSO NOTICED THAT THE | | NEW BUILDING WILL HAVE AN UPSTIRS AND DOWNSTAIRS | | TENANT, ADDRESSES WILL NEED TO BE WORKED ON FOR THE | | PERMIT. PLEASE CONTACT [email protected] OR CALL | | 561-805-6659 TO DISCUSS ADDRESSES |
|
|
Review Stop |
AIPP |
ART IN PUBLIC PLACES |
Rev No |
1 |
Status |
P |
Date |
2023-03-07 |
|
|
Cont ID |
|
Sent By |
swelter |
Date |
2023-03-07 |
Time |
10:34 |
Rev Time |
0.00 |
Received By |
swelter |
Date |
2023-03-10 |
Time |
12:46 |
Sent To |
|
|
Notes |
2023-03-07 10:36:37 | SEE MASTER PERMIT # 22120561 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2023-07-06 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2023-07-06 |
Time |
13:44 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2023-07-06 |
Time |
13:23 |
Sent To |
|
|
Notes |
2023-07-06 13:34:11 | NEW BUILDING | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected] | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | AMENDMENT | | | | CORRECTIONS NEEDED - | | | | 1) PLEASE SHOW ON THE FLOOR PLAN THE NORTH EXTERIOR | | WALL WHICH IS 7' 6" FROM THE PROPERTY LINE TO BE 1 HOUR | | FIRE RATED - FBC TABLE 602 | | | | 2) PLEASE SHOW THE CALCULATIONS FOR THE UNPROTECTED | | OPENINGS IN THE NORTH EXTERIOR WALL WHICH IS 7' 6" FROM | | THE PROPERTY LINES - PER FBC TABLE 705.8 | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2023-05-10 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2023-05-10 |
Time |
11:22 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2023-05-10 |
Time |
11:04 |
Sent To |
|
|
Notes |
2023-05-10 11:11:57 | NEW BUILDING | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected] | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | AMENDMENT | | | | CORRECTIONS NEEDED - | | | | 1) PLEASE SHOW THE BUILDING SETBACK DIMENSIONS FROM THE | | PROPERTY LINES.- FBC WPB 107.2.5 SITE PLAN. THE | | CONSTRUCTION DOCUMENTS SUBMITTED WITH THE APPLICATION | | FOR PERMIT SHALL BE ACCOMPANIED BY A SITE PLAN SHOWING | | TO SCALE THE SIZE AND LOCATION OF NEW CONSTRUCTION AND | | EXISTING STRUCTURES ON THE SITE, DISTANCES FROM LOT | | LINES, THE ESTABLISHED STREET GRADES AND THE PROPOSED | | FINISHED GRADES, DEPICTING THE PROPOSED LOT DRAINAGE | | AND, AS APPLICABLE, FLOOD HAZARD AREAS, FLOODWAYS, AND | | DESIGN FLOOD ELEVATIONS; AND IT SHALL BE DRAWN IN | | ACCORDANCE WITH AN ACCURATE AND INCLUDED ON A BOUNDARY | | LINE SURVEY. (PLEASE PROVIDE CUT SECTIONS FOR ANY | | PROPOSED WATER RETAINING SWALES) | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2023-02-09 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2023-02-09 |
Time |
16:12 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2023-02-09 |
Time |
13:08 |
Sent To |
|
|
Notes |
2023-02-09 16:06:33 | NEW BUILDING | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected] | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | AMENDMENT | | | | CORRECTIONS NEEDED - | | | | 1) PLEASE PROVIDE A SITE PLAN SHOWING THE FOLLOWING - | | FBC WPB 107.2.5 SITE PLAN. THE CONSTRUCTION DOCUMENTS | | SUBMITTED WITH THE APPLICATION FOR PERMIT SHALL BE | | ACCOMPANIED BY A SITE PLAN SHOWING TO SCALE THE SIZE | | AND LOCATION OF NEW CONSTRUCTION AND EXISTING | | STRUCTURES ON THE SITE, DISTANCES FROM LOT LINES, THE | | ESTABLISHED STREET GRADES AND THE PROPOSED FINISHED | | GRADES, DEPICTING THE PROPOSED LOT DRAINAGE AND, AS | | APPLICABLE, FLOOD HAZARD AREAS, FLOODWAYS, AND DESIGN | | FLOOD ELEVATIONS; AND IT SHALL BE DRAWN IN ACCORDANCE | | WITH AN ACCURATE AND INCLUDED ON A BOUNDARY LINE | | SURVEY. (PLEASE PROVIDE CUT SECTIONS FOR ANY PROPOSED | | WATER RETAINING SWALES) | | | | 2) PLEASE PROVIDE A SURVEY | | | | 3) DRAWING T.100 UNDER PROJECT DATA - BUILDING SQUARE | | FOOT FOR OCCUPANT LOAD APPEARS TO BE INCORRECT - PLEASE | | CORRECT. | | | | 4) DRAWING T.100 STATES THAT A RESTROOM IS PROVIDED - A | | RESTROOM IS NOT SHOWN ON THE PLAN. | | | | 5) RISK CATEGORY SHOWN IS "II" - FOR A BUILDING WITH AN | | ASSEMBLY OCCUPANCY OVER 300 WILL BE A RISK CATEGORY III | | WITH WIND DESIGN SPEED OF 180MPH PER FBC TABLE 1604.5 | | | | 6) PLEASE SHOW THE ADJACENT BUILDING OCCUPANCY | | CLASSIFICATION FBC TABLE 706.4 | | | | 7) DOORS CANNOT SWING BEYOND THE PROPERTY LINE - FBC | | 3202.2 DOORS AND WINDOWS SHALL NOT OPEN OR PROJECT INTO | | THE PUBLIC RIGHT-OF-WAY. | | | | 8) PLEASE SHOW THAT THE BUILDING ENTRIES ARE ACCESSIBLE | | - FBC 206.2.1 | | AT LEAST ONE ACCESSIBLE ROUTE SHALL BE PROVIDED WITHIN | | THE SITE FROM ACCESSIBLE PARKING SPACES AND ACCESSIBLE | | PASSENGER LOADING ZONES; PUBLIC STREETS AND SIDEWALKS; | | AND PUBLIC TRANSPORTATION STOPS TO THE ACCESSIBLE | | BUILDING OR FACILITY ENTRANCE THEY SERVE. - 206.2.4 | | SPACES AND ELEMENTS. | | AT LEAST ONE ACCESSIBLE ROUTE SHALL CONNECT ACCESSIBLE | | BUILDING OR FACILITY ENTRANCES WITH ALL ACCESSIBLE | | SPACES AND ELEMENTS WITHIN THE BUILDING OR FACILITY | | WHICH ARE OTHERWISE CONNECTED BY A CIRCULATION PATH | | | | 9) A SEPARATE PERMIT IS REQUIRED FOR - EXISTING | | BUILDING DEMO. | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2023-07-13 |
|
|
Cont ID |
|
Sent By |
mpeterso |
Date |
2023-07-13 |
Time |
13:43 |
Rev Time |
0.00 |
Received By |
mpeterso |
Date |
2023-07-13 |
Time |
13:39 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2023-02-06 |
|
|
Cont ID |
|
Sent By |
mpeterso |
Date |
2023-02-06 |
Time |
13:27 |
Rev Time |
0.00 |
Received By |
mpeterso |
Date |
2023-02-03 |
Time |
11:01 |
Sent To |
|
|
Notes |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
2 |
Status |
P |
Date |
2023-07-13 |
|
|
Cont ID |
|
Sent By |
cseifer |
Date |
2023-07-13 |
Time |
08:15 |
Rev Time |
0.00 |
Received By |
cseifer |
Date |
2023-07-13 |
Time |
08:15 |
Sent To |
|
|
Notes |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
1 |
Status |
P |
Date |
2023-02-07 |
|
|
Cont ID |
|
Sent By |
rrossano |
Date |
2023-02-07 |
Time |
|
Rev Time |
|
Received By |
rrossano |
Date |
2023-02-07 |
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
P |
Date |
2023-07-10 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2023-07-10 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2023-07-10 |
Time |
13:35 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2023-05-09 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2023-05-09 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2023-05-09 |
Time |
09:43 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2023-02-02 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2023-02-02 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2023-02-02 |
Time |
10:40 |
Sent To |
|
|
Notes |
2023-02-02 11:18:35 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | 1) THERE ARE REAR EXITS INDICATED ON THE LIFE SAFETY | | PLANS, | | | | PER NFPA 101, CH 12 NEW ASSEMBLY, 38 NEW BUSINESS, & CH | | 7 MEANS OF EGRESS. | | | | 7.7 DISCHARGE FROM EXITS | | 7.7.1* EXIT TERMINATION. EXITS SHALL TERMINATE | | DIRECTLY, AT A PUBLIC | | WAY OR AT AN EXTERIOR EXIT DISCHARGE, UNLESS OTHERWISE | | PROVIDED IN 7.7.1.2 | | THROUGH 7.7.1.4. | | | | THERE MAY BE A SERVICE ROAD NEXT TO THE RR, HOWEVER, I | | BELIEVE A FENCE IS BEING PROPOSED THAT MAY | | LIMIT/RESTRICT PASSAGE IN EITHER DIRECTION. | | | | THERE MAY ALSO BE GATES ALONG THIS FENCE THAT NEEDS TO | | BE ACCESSIBLE. | | | | AN ADDITIONAL CONCERN IS THAT THERE MAY BE UNPROTECTED | | OPENINGS ALONG ALL THE VARIOUS OCCUPANCIES ALONG THE | | FENCE LINE THAT COULD EXPOSE PEDESTRIANS TO THE EFFECTS | | OF FIRE AND SMOKE. | | | | PLEASE PROVIDE DETAILS IN COMPLIANCE WITH THE REQUIRED | | CODE. | | | | | | | | 2) SHEET LS 101 - THERE IS AN INDICATION REGARDING THE | | KNOX BOX LOCATION WITH A REFERENCE TO COORDINATE | | LOCATION WITH PBC FIRE RESCUE. | | | | THE JURISDICTION IS WEST PALM BEACH FIRE DEPARTMENT. | | | | PLEASE CORRECT AND CONTACT MY OFFICE AND/OR MY FIRE | | INSPECTOR FOR LOCATION. | | | | | | 3) SHEET A 600 - WITHIN THE DOOR SCHEDULE, DOOR 103 HAS | | AN INDICATION OF DOOR SET 05. | | | | THIS APPEARS TO INDICATE THE EXIT BAR WITHIN THE LOBBY | | AND LVER SET WITHIN THE STAIRWELL. | | | | PLEASE REVIEW AND CORRECT AS APPLICABLE. | | | | | | | | 4) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | ABOVE. | | | | | | 5) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | RE-SUBMITTAL OF THE ABOVE. DELINEATE | | | | | | PETER LEDUC | | FIRE MARSHAL | | 561-804-4709 | | [email protected] | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
2 |
Status |
N |
Date |
2023-05-09 |
|
|
Cont ID |
|
Sent By |
rwbrown |
Date |
2023-05-09 |
Time |
07:01 |
Rev Time |
0.00 |
Received By |
rwbrown |
Date |
2023-05-09 |
Time |
07:01 |
Sent To |
|
|
Notes |
2023-05-09 07:01:40 | SEPARATE PERMIT PER NOTES ON P-100 |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
F |
Date |
2023-02-02 |
|
|
Cont ID |
|
Sent By |
rwbrown |
Date |
2023-02-02 |
Time |
14:39 |
Rev Time |
0.00 |
Received By |
rwbrown |
Date |
2023-02-02 |
Time |
14:39 |
Sent To |
|
|
Notes |
2023-02-02 14:40:30 | 1ST GAS REVIEW | | | | THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED | | BY RYAN BROWN WITH THE FOLLOWING COMMENTS. | | | | 1. 2017 WPB AMEND 107.3.5.3 (13) - I DID NOT SEE A GAS | | DETAIL. DO YOU PLAN TO ROUGH IN GAS. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM. | | | | | | RYAN W. BROWN | | CHIEF PLUMBING INSPECTOR | | OFFICE: 561-805-6692 | | CELL: 561-517-4293 | | EMAIL: [email protected] | | | | | | V7 FPC - 2020 FLORIDA PLUMBING CODE | | V7 FGC - 2020 FLORIDA FUEL GAS | | V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE | | V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE | | V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE | | V7 FEC - 2020 FLORIDA ENERGY CONSERVATION | | 2021 F.S. - 2021 FLORIDA STATUTES | | 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE | | 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE | | FBC CHAPTER 1 | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
|
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
Received By |
amcgrego |
Date |
2023-07-05 |
Time |
09:33 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2023-05-31 |
|
|
Cont ID |
|
Sent By |
aoliver |
Date |
2023-05-31 |
Time |
07:44 |
Rev Time |
0.00 |
Received By |
aoliver |
Date |
2023-05-08 |
Time |
08:09 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2023-03-07 |
|
|
Cont ID |
|
Sent By |
aoliver |
Date |
2023-03-07 |
Time |
08:54 |
Rev Time |
0.00 |
Received By |
aoliver |
Date |
2023-01-31 |
Time |
15:55 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2023-02-09 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2023-02-09 |
Time |
16:12 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2023-02-09 |
Time |
16:12 |
Sent To |
|
|
Notes |
2023-02-09 16:12:40 | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF | | | | UPON APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE | | RECEIPT TO YOUR PROJECT OR EMAIL IT TO | | [email protected] . | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2023-07-20 |
|
|
Cont ID |
|
Sent By |
cmontell |
Date |
2023-07-20 |
Time |
13:34 |
Rev Time |
0.00 |
Received By |
cmontell |
Date |
2023-07-20 |
Time |
13:34 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2023-05-09 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2023-05-09 |
Time |
15:08 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2023-05-09 |
Time |
15:08 |
Sent To |
|
|
Notes |
2023-05-09 15:10:39 | IT APPEARS THAT THE MECHAICAL COMMENTS FOR THIS PROJECT | | GOT MIXED UP WITH ANOTHER PROJECT WHEN YOU RESUBMITTED. | | PLEASE ADDRESS THE COMMET BELOOW AS THIS PROJECT HAS | | THE LOBBIES AND VENTILATION ISSUES, NOT THE RATED | | WALLS. | | | | 1ST REVIEW FMC | | PERMIT: 23011162 | | | | CODES IN EFFECT: 2020 | | | | FBC- FLORIDA BUILDING CODE | | FMC- FLORIDA MECHANICAL CODE | | FEC- FLORIDA ENERGY CONSERVATION | | FGC- FLORIDA FUEL GAS | | FEX- FLORIDA EXISTING BUILDING CODE | | FRC- FLORIDA RESIDENTIAL BUILDING CODE | | F.S.- FLORIDA STATUTES | | FAC- FLORIDA ACCESSIBILITY CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) SHEET M-600: IN THE VENTILATION RATES SCHEDULE THE | | ROOMS ARE IDENTIFIED AS LOBBY ON BOTH FLOORS. TABLE | | 403.3.1.1 INDICATES LOBBIES TO BE CALCULATED WITH AN | | OCCUPANCY DENSITY OF 150 WITH A PERSON CFM OF 7.5 AND | | THE BREATHING ZONE CFM/SQ FT. OF 0.06. WITH USING | | LOBBIES FROM TABLE 403.3.1.1 THE OUTDOOR AIR | | CALCULATION FOR BOTH LOBBIES ARE LOW. PLEASE PROVIDE | | THE CORRECTED VENTILATION RATES FOR THESE SPACES. FMC | | 403.3.1.1 AND TABLE 403.3.1.1 | | | | 2) THESE DRAWINGS INDICATE THAT THIS IS ONLY THE | | BUILDING SHELL. SHEET T.100 INDICATES THIS DESIGN OF | | THIS BUILDING IS FOR WORST CASE SCENARIO WHICH IS | | ASSEMBLY A-2 BUT SHEET M-600 IN THE BASIS OF DESIGN FOR | | FUTURE TENANTS DOES NOT REFLECT THE OUTDOOR AIR OR | | EXHAUST REQUIREMENTS FOR THE WORST CASE SCENARIO. | | EITHER REMOVE ALL COMMENTS AND TABLES FOR THE FUTURE | | USE OR PROVIDE THE CORRECTED SCHEDULES REQUIRED FOR THE | | ASSEMBLY A-2 THAT IS STATED ON SHEET T.100. FMC | | 403.3.1.1; TABLE 403.3.1.1 AND FBC 107.3.5 | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM. | | | | MICHAEL EDWARDS | | MECHANICAL EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL. 33401 | | 561-805-6728 | | [email protected] | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2023-02-02 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2023-02-02 |
Time |
10:31 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2023-02-02 |
Time |
10:31 |
Sent To |
|
|
Notes |
2023-02-02 10:31:49 | 1ST REVIEW FMC | | PERMIT: 23011162 | | | | CODES IN EFFECT: 2020 | | | | FBC- FLORIDA BUILDING CODE | | FMC- FLORIDA MECHANICAL CODE | | FEC- FLORIDA ENERGY CONSERVATION | | FGC- FLORIDA FUEL GAS | | FEX- FLORIDA EXISTING BUILDING CODE | | FRC- FLORIDA RESIDENTIAL BUILDING CODE | | F.S.- FLORIDA STATUTES | | FAC- FLORIDA ACCESSIBILITY CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) SHEET M-600: IN THE VENTILATION RATES SCHEDULE THE | | ROOMS ARE IDENTIFIED AS LOBBY ON BOTH FLOORS. TABLE | | 403.3.1.1 INDICATES LOBBIES TO BE CALCULATED WITH AN | | OCCUPANCY DENSITY OF 150 WITH A PERSON CFM OF 7.5 AND | | THE BREATHING ZONE CFM/SQ FT. OF 0.06. WITH USING | | LOBBIES FROM TABLE 403.3.1.1 THE OUTDOOR AIR | | CALCULATION FOR BOTH LOBBIES ARE LOW. PLEASE PROVIDE | | THE CORRECTED VENTILATION RATES FOR THESE SPACES. FMC | | 403.3.1.1 AND TABLE 403.3.1.1 | | | | 2) THESE DRAWINGS INDICATE THAT THIS IS ONLY THE | | BUILDING SHELL. SHEET T.100 INDICATES THIS DESIGN OF | | THIS BUILDING IS FOR WORST CASE SCENARIO WHICH IS | | ASSEMBLY A-2 BUT SHEET M-600 IN THE BASIS OF DESIGN FOR | | FUTURE TENANTS DOES NOT REFLECT THE OUTDOOR AIR OR | | EXHAUST REQUIREMENTS FOR THE WORST CASE SCENARIO. | | EITHER REMOVE ALL COMMENTS AND TABLES FOR THE FUTURE | | USE OR PROVIDE THE CORRECTED SCHEDULES REQUIRED FOR THE | | ASSEMBLY A-2 THAT IS STATED ON SHEET T.100. FMC | | 403.3.1.1; TABLE 403.3.1.1 AND FBC 107.3.5 | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM. | | | | MICHAEL EDWARDS | | MECHANICAL EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL. 33401 | | 561-805-6728 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2023-07-07 |
|
|
Cont ID |
|
Sent By |
rwbrown |
Date |
2023-07-07 |
Time |
07:31 |
Rev Time |
0.00 |
Received By |
rwbrown |
Date |
2023-07-07 |
Time |
07:31 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2023-05-09 |
|
|
Cont ID |
|
Sent By |
rwbrown |
Date |
2023-05-09 |
Time |
06:55 |
Rev Time |
0.00 |
Received By |
rwbrown |
Date |
2023-05-09 |
Time |
06:55 |
Sent To |
|
|
Notes |
2023-05-09 07:01:00 | 1ST PLUMBING REVIEW | | | | THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED | | BY RYAN BROWN WITH THE FOLLOWING COMMENTS. | | | | 1. ENGINEERING PERMITS DO NOT REPLACE THE NEED FOR | | BUILDING PERMITS FOR THE BACKFLOWS AND GREASE TRAPS - | | 2017 WPB AMEND - 105.1/107.3 -- THE BACKFLOW DEVICE AT | | THE UTILITY CONNECTION AND THE GREASE TRAP REQUIRE | | SEPARATE PERMITS THAT ARE REQUIRED TO BE APPLIED FOR | | PRIOR TO ISSUANCE OF THE PRIMARY PERMIT (AS | | APPLICABLE). YOU CAN SUBMIT AN APPLICATION "TBD" (TO BE | | DETERMINED) IF YOU DO NOT HAVE A CONTRACTOR SELECTED BY | | EMAILING A COMPLETED PERMIT APPLICATION TO | | [email protected] . AFTER YOU HAVE THE PERMIT(S) | | GENERATED, NOTIFY ME VIA EMAIL OR NOTE IN THE RESPONSE | | LETTER AND I WILL COMPLY THIS COMMENT. | | | | 2. DONE | | | | 3. DONE | | | | 4. DONE | | | | 5. DONE | | | | 6. DONE | | | | 7. DONE | | | | 8. DONE | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM. | | | | | | RYAN W. BROWN | | CHIEF PLUMBING INSPECTOR | | OFFICE: 561-805-6692 | | CELL: 561-517-4293 | | EMAIL: [email protected] | | | | | | V7 FPC - 2020 FLORIDA PLUMBING CODE | | V7 FGC - 2020 FLORIDA FUEL GAS | | V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE | | V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE | | V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE | | V7 FEC - 2020 FLORIDA ENERGY CONSERVATION | | 2021 F.S. - 2021 FLORIDA STATUTES | | 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE | | 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE | | FBC CHAPTER 1 | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2023-02-02 |
|
|
Cont ID |
|
Sent By |
rwbrown |
Date |
2023-02-02 |
Time |
12:55 |
Rev Time |
0.00 |
Received By |
rwbrown |
Date |
2023-02-02 |
Time |
12:41 |
Sent To |
|
|
Notes |
2023-02-02 14:32:20 | 1ST PLUMBING REVIEW | | | | THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED | | BY RYAN BROWN WITH THE FOLLOWING COMMENTS. | | | | 1. 2017 WPB AMEND - 105.1/107.3 -- THE BACKFLOW DEVICE | | AT THE UTILITY CONNECTION AND THE GREASE TRAP REQUIRE | | SEPARATE PERMITS THAT ARE REQUIRED TO BE APPLIED FOR | | PRIOR TO ISSUANCE OF THE PRIMARY PERMIT (AS | | APPLICABLE). YOU CAN SUBMIT AN APPLICATION "TBD" (TO BE | | DETERMINED) IF YOU DO NOT HAVE A CONTRACTOR SELECTED BY | | EMAILING A COMPLETED PERMIT APPLICATION TO | | [email protected] . AFTER YOU HAVE THE PERMIT(S) | | GENERATED, NOTIFY ME VIA EMAIL OR NOTE IN THE RESPONSE | | LETTER AND I WILL COMPLY THIS COMMENT. | | | | 2. 2020 FPC 607.1.1/613.1 - THE WATER HEATER AT THE | | JANITOR SINK SHALL HAVE A MIXING VALVE. ALL HOT WATER | | SHALL BE LIMITED BY SOMETHING OTHER THAN THE THERMOSTAT | | ON THE WATER HEATER. | | | | 3. 2020 FPC 901.2.1 - PROVIDE A VENT FOR THE JANITOR | | SINK. | | | | 4. 2020 FPC 906.1 - IT APPEARS THAT ACCORDING TO TABLE | | 906.1, YOU NEED AT THE MINIMUM A 3" VENT STACK TO THE | | DOWNSTAIRS TENANT. 4" DRAINS WITH THAT MANY DFU'S | | CANNOT BE VENTED OFF OF 2". PLEASE RECALCULATE THE | | FUTURE VENT SIZING. | | | | 5. 2020 FPC 1003.4 - PLEASE SHOW THE OIL ALARM OR OIL | | SEPARATOR FOR THE SUMP IN THE ELEVATOR SHAFT. | | | | 6. 2020 FPC 712.3.2/906.5 - PLEASE DETAIL A VENT FOR | | THE SUMP PIT. | | | | 7. 2020 FPC 606.2 - ADD A SHUT OFF ON THE SUPPLY LINE | | TO THE HOSE BIB. | | | | 8. 2017 WPB AMENDS 107.3.5.1.3 - PLEASE ADD A DETAIL | | FOR THE SCUPPERS | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM. | | | | | | RYAN W. BROWN | | CHIEF PLUMBING INSPECTOR | | OFFICE: 561-805-6692 | | CELL: 561-517-4293 | | EMAIL: [email protected] | | | | | | V7 FPC - 2020 FLORIDA PLUMBING CODE | | V7 FGC - 2020 FLORIDA FUEL GAS | | V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE | | V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE | | V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE | | V7 FEC - 2020 FLORIDA ENERGY CONSERVATION | | 2021 F.S. - 2021 FLORIDA STATUTES | | 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE | | 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE | | FBC CHAPTER 1 | | |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
N |
Date |
2023-02-09 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2023-02-09 |
Time |
16:13 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2023-02-09 |
Time |
16:12 |
Sent To |
|
|
Notes |
2023-02-09 16:13:31 | ROOFING SYSTEMS TO BE DEFERRED |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
3 |
Status |
P |
Date |
2023-07-06 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2023-07-06 |
Time |
13:54 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2023-07-06 |
Time |
13:54 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2023-05-10 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2023-05-10 |
Time |
11:23 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2023-05-10 |
Time |
11:23 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
P |
Date |
2023-02-06 |
|
|
Cont ID |
|
Sent By |
mpeterso |
Date |
2023-02-06 |
Time |
13:32 |
Rev Time |
0.00 |
Received By |
mpeterso |
Date |
2023-02-06 |
Time |
13:32 |
Sent To |
|
|
Notes |
2023-02-06 13:32:42 | ALL PLANS PASSED SIGNATURE REVIEW | 2023-02-02 10:38:39 | MECHANICAL DIGITAL SIGNATURES APPROVED ME |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
|
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
Received By |
|
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2023-05-30 |
|
|
Cont ID |
|
Sent By |
ckimmerl |
Date |
2023-05-30 |
Time |
10:19 |
Rev Time |
0.00 |
Received By |
ckimmerl |
Date |
2023-05-30 |
Time |
10:19 |
Sent To |
|
|
Notes |
2023-05-30 10:19:21 | PROPOSAL FOR 925 N RAILROAD AVENUE HAS BEEN SUBMITTED | | FOR FORMAL SITE PLAN APPROVAL AND HAS NOT RECEIVED SAID | | APPROVAL. | | ZONING STAFF CAN NOT REVIEW OR APPROVE OF THE BUILDING | | PERMIT WITHOUT FIRST RESUBMITTING AND OBTAINING THE | | SITE PLAN APPROVAL FOR FSPR 22-23 (Z22090018). | | | | CHRIS KIMMERLY, AICP | | URBAN DESIGN PLANNER | | [email protected] 822-1426 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2023-03-06 |
|
|
Cont ID |
|
Sent By |
CKimmerl |
Date |
2023-03-06 |
Time |
14:41 |
Rev Time |
0.00 |
Received By |
ckimmerl |
Date |
2023-03-06 |
Time |
14:37 |
Sent To |
|
|
Notes |
2023-03-06 14:41:53 | PROPOSAL FOR 925 N RAILROAD AVENUE HAS BEEN SUBMITTED | | FOR FORMAL SITE PLAN APPROVAL AND HAS NOT RECEIVED SAID | | APPROVAL. | | ZONING STAFF CAN NOT REVIEW OR APPROVE OF THE BUILDING | | PERMIT WITHOUT FIRST RESUBMITTING AND OBTAINING THE | | SITE PLAN APPROVAL FOR FSPR 22-23 (Z22090018). | | | | CHRIS KIMMERLY, AICP | | URBAN DESIGN PLANNER | | [email protected] 822-1426 |
|
|