Plan Review Details - Permit 23011118
Plan Review Stops For Permit 23011118
Review Stop AD ADDRESSING
Rev No 3 Status P Date 2023-02-02 Cont ID  
Sent By cpuell Date 2023-02-02 Time 16:07 Rev Time 0.00
Received By cpuell Date 2023-02-02 Time 16:07 Sent To  
Notes
2023-02-02 16:08:10ZONING NOT ALLOWING A SECONDARY UNIT, AS SUCH NO
 ADDITION ADDRESS IS REQUIRED

Review Stop AD ADDRESSING
Rev No 2 Status F Date 2023-01-31 Cont ID  
Sent By cpuell Date 2023-01-31 Time 07:36 Rev Time 0.00
Received By cpuell Date 2023-01-31 Time 07:36 Sent To  
Notes
2023-01-31 07:36:50A SECONDARY ADDRESS MAY NEED TO BE ASSIGNED IF ZONING
 APPROVES A SECONDARY UNIT. PLEASE CONTACT
 [email protected] OR CALL 561-805-6659 ONCE ZONING
 APPROVES THEIR REVIEW.

Review Stop AD ADDRESSING
Rev No 1 Status F Date 2023-01-26 Cont ID  
Sent By cpuell Date 2023-01-26 Time 07:24 Rev Time 0.00
Received By cpuell Date 2023-01-26 Time 07:24 Sent To  
Notes
2023-01-26 07:36:06THIS PARCEL CURRENTLY HAS A BUILDING ON IT, PLEASE
 PROVIDE A SITE PLAN SHOWING WHERE THE NEW DETACHED UNIT
 WILL BE LOCATED ON THE PARCEL.A SECONDARY ADDRESS MAY
 NEED TO BE ASSIGNED IF ZONING APPROVES A SECONDARY
 UNIT. PLEASE CONTACT [email protected] OR CALL
 561-805-6659 ONCE ZONING APPROVES THEIR REVIEW.

Review Stop B BUILDING (STRUCTURAL)
Rev No 7 Status P Date 2023-06-01 Cont ID  
Sent By rmcphers Date 2023-06-01 Time 07:59 Rev Time 0.00
Received By rmcphers Date 2023-06-01 Time 07:59 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 6 Status F Date 2023-05-31 Cont ID  
Sent By rmcphers Date 2023-05-31 Time 12:43 Rev Time 0.00
Received By rmcphers Date 2023-05-31 Time 12:43 Sent To  
Notes
2023-05-31 12:45:58POOL HOUSE
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
  
 1) REVISED DRAWING A1.0 DOES NOT SHOW AS DIGITALLY
 SIGNED BY THE ARCHITECT IN ADOBE READER - SIGNED AND
 SEALED DRAWINGS IN PROJECTDOX NEED TO BE
 DIGITALLY/ELECTRONICALLY SIGNED TO BE USED IN
 ELECTRONIC PLAN REVIEW. (A CERTIFICATE-BASED DIGITAL
 SIGNATURE (OFTEN JUST CALLED A DIGITAL SIGNATURE) IS A
 SPECIFIC TYPE OF E-SIGNATURE).
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status P Date 2023-05-10 Cont ID  
Sent By rmcphers Date 2023-05-10 Time 14:29 Rev Time 0.00
Received By rmcphers Date 2023-05-10 Time 14:29 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status F Date 2023-05-05 Cont ID  
Sent By rmcphers Date 2023-05-05 Time 08:41 Rev Time 0.00
Received By rmcphers Date 2023-05-05 Time 08:18 Sent To  
Notes
2023-05-05 08:25:32POOL HOUSE
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
  
 1) (THE PRODUCT APPROVAL PROVIDED FOR THE FOAM IS FOR A
 FOAM ROOFING SYSTEM THE DRAWINGS SHOW THE ROOFING
 SYSTEM TO BE SHINGLES). PLEASE PROVIDE DOCUMENTATION
 FOR THE SPRAY FOAM INSULATION (ICC - ES EVALUATION
 REPORT) - FBC R316.3 SURFACE BURNING CHARACTERISTICS.
 UNLESS OTHERWISE ALLOWED IN SECTION R316.5, FOAM
 PLASTIC OR FOAM PLASTIC CORES USED AS A COMPONENT IN
 MANUFACTURED ASSEMBLIES USED IN BUILDING CONSTRUCTION
 SHALL HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 75 AND
 SHALL HAVE A SMOKE-DEVELOPED INDEX OF NOT MORE THAN 450
 WHEN TESTED IN THE MAXIMUM THICKNESS AND DENSITY
 INTENDED FOR USE IN ACCORDANCE WITH ASTM E84 OR UL 723.
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2023-04-18 Cont ID  
Sent By rmcphers Date 2023-04-18 Time 15:48 Rev Time 0.00
Received By rmcphers Date 2023-04-18 Time 15:27 Sent To  
Notes
2023-04-18 15:45:05POOL HOUSE
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
  
 1) SEE DRAWING A-1.0 GENERAL NOTE NUMBER 7 - (NOTE
 NUMBER 7 CAN BE CHANGED TO STATE THE SOIL BEARING
 CAPACITY IS 2500 PSF OR MORE) - PLEASE PROVIDE A SOIL
 REPORT (GEOTECHNICAL REPORT) FBC 1803.2
  
 2) PLEASE PROVIDE COMPLETE (FRONT PAGES AND THE
 INSTALLATION INSTRUCTIONS) MIAMI DADE OR FLORIDA STATE
 PRODUCT APPROVALS FOR THE EXTERIOR SLIDING GLASS DOOR -
 ALL PRODUCT APPROVALS NEED TO BE REVIEWED AND MARKED
 APPROVED BY THE BUILDING DESIGNER OF RECORD FBC WPB
 107.3.4
  
 3) A PRODUCT APPROVAL HAS BEEN PROVIDED FOR A SINGLE
 HUNG WINDOW - THE DRAWINGS DO NOT SHOW A LOCATION FOR A
 SINGLE HUNG WINDOW.
  
 4) PRODUCT APPROVAL (FL11136 - R8) FOR THE SWING DOOR
 IS FOR THE 2017 FBC CODE VERSION - YOU NEED TO PROVIDE
 A DOOR PRODUCT APPROVAL FOR THE 2020 FBC CODE VERSION.
  
 5) PLEASE PROVIDE DOCUMENTATION FOR THE SPRAY FOAM
 INSULATION (ICC - ES EVALUATION REPORT) - FBC R316.3
 SURFACE BURNING CHARACTERISTICS.
 UNLESS OTHERWISE ALLOWED IN SECTION R316.5, FOAM
 PLASTIC OR FOAM PLASTIC CORES USED AS A COMPONENT IN
 MANUFACTURED ASSEMBLIES USED IN BUILDING CONSTRUCTION
 SHALL HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 75 AND
 SHALL HAVE A SMOKE-DEVELOPED INDEX OF NOT MORE THAN 450
 WHEN TESTED IN THE MAXIMUM THICKNESS AND DENSITY
 INTENDED FOR USE IN ACCORDANCE WITH ASTM E84 OR UL 723.
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2023-03-08 Cont ID  
Sent By rmcphers Date 2023-03-08 Time 11:21 Rev Time 0.00
Received By rmcphers Date 2023-03-08 Time 11:21 Sent To  
Notes
2023-03-08 11:25:35POOL HOUSE
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
  
 1) PLEASE PROVIDE A SOIL REPORT (GEOTECHNICAL REPORT)
 FBC 1803.2
  
 2) PLEASE PROVIDE COMPLETE (FRONT PAGES AND THE
 INSTALLATION INSTRUCTIONS) MIAMI DADE OR FLORIDA STATE
 PRODUCT APPROVALS FOR THE EXTERIOR SLIDING GLASS DOOR,
 EXTERIOR SWING DOOR AND THE ROOFING SYSTEMS - ALL
 PRODUCT APPROVALS NEED TO BE REVIEWED AND MARKED
 APPROVED BY THE BUILDING DESIGNER OF RECORD FBC WPB
 107.3.4
  
 3) PLEASE SHOW THE ROOF SHEATHING TYPE AND THICKNESS -
 FBC WPB 107.2.1
  
 4) PLEASE PROVIDE DOCUMENTATION FOR THE SPRAY FOAM
 INSULATION (ICC - ES EVALUATION REPORT) - FBC R316.3
 SURFACE BURNING CHARACTERISTICS.
 UNLESS OTHERWISE ALLOWED IN SECTION R316.5, FOAM
 PLASTIC OR FOAM PLASTIC CORES USED AS A COMPONENT IN
 MANUFACTURED ASSEMBLIES USED IN BUILDING CONSTRUCTION
 SHALL HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 75 AND
 SHALL HAVE A SMOKE-DEVELOPED INDEX OF NOT MORE THAN 450
 WHEN TESTED IN THE MAXIMUM THICKNESS AND DENSITY
 INTENDED FOR USE IN ACCORDANCE WITH ASTM E84 OR UL 723.
  
 5) PLEASE SHOW THE STORM WATER FLOW AWAY FROM THE
 BUILDING AND AWAY FROM THE ADJACENT PROPERTY - FBC WPB
 107.2.5 SITE PLAN. THE CONSTRUCTION DOCUMENTS SUBMITTED
 WITH THE APPLICATION FOR PERMIT SHALL BE ACCOMPANIED BY
 A SITE PLAN SHOWING TO SCALE THE SIZE AND LOCATION OF
 NEW CONSTRUCTION AND EXISTING STRUCTURES ON THE SITE,
 DISTANCES FROM LOT LINES, THE ESTABLISHED STREET GRADES
 AND THE PROPOSED FINISHED GRADES, DEPICTING THE
 PROPOSED LOT DRAINAGE AND, AS APPLICABLE, FLOOD HAZARD
 AREAS, FLOODWAYS, AND DESIGN FLOOD ELEVATIONS; AND IT
 SHALL BE DRAWN IN ACCORDANCE WITH AN ACCURATE AND
 INCLUDED ON A BOUNDARY LINE SURVEY. (PLEASE PROVIDE CUT
 SECTIONS FOR ANY PROPOSED WATER RETAINING SWALES)

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2023-02-02 Cont ID  
Sent By rmcphers Date 2023-02-02 Time 13:38 Rev Time 0.00
Received By rmcphers Date 2023-02-02 Time 12:53 Sent To  
Notes
2023-02-02 13:30:31POOL HOUSE
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
  
 1) PLEASE PROVIDE A SOIL REPORT (GEOTECHNICAL REPORT)
 FBC 1803.2
  
 2) PLEASE PROVIDE COMPLETE (FRONT PAGES AND THE
 INSTALLATION INSTRUCTIONS) MIAMI DADE OR FLORIDA STATE
 PRODUCT APPROVALS FOR THE EXTERIOR SLIDING GLASS DOOR,
 EXTERIOR SWING DOOR AND THE ROOFING SYSTEMS - ALL
 PRODUCT APPROVALS NEED TO BE REVIEWED AND MARKED
 APPROVED BY THE BUILDING DESIGNER OF RECORD FBC WPB
 107.3.4
  
 3) PLEASE SHOW THE ROOF SHEATHING TYPE AND THICKNESS -
 FBC WPB 107.2.1
  
 4) DRAWING A-1.01 TYPICAL WALL SECTION SHOWS ATTIC
 VENTILATION AND SPRAY FOAM INSULATION - SHOULD NOT HAVE
 ATTIC VENTILATION WITH FOAM ATTACHED TO THE UNDERSIDE
 OF THE ROOF SHEATHING. SEE FOAM INSULATION INSTRUCTIONS
 AND PROVIDE THOSE INSTRUCTIONS. (ICC - ES EVALUATION
 REPORT) - FBC R316.3 SURFACE BURNING CHARACTERISTICS.
 UNLESS OTHERWISE ALLOWED IN SECTION R316.5, FOAM
 PLASTIC OR FOAM PLASTIC CORES USED AS A COMPONENT IN
 MANUFACTURED ASSEMBLIES USED IN BUILDING CONSTRUCTION
 SHALL HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 75 AND
 SHALL HAVE A SMOKE-DEVELOPED INDEX OF NOT MORE THAN 450
 WHEN TESTED IN THE MAXIMUM THICKNESS AND DENSITY
 INTENDED FOR USE IN ACCORDANCE WITH ASTM E84 OR UL 723.
  
 5) PLEASE SHOW THE STORM WATER FLOW AWAY FROM THE
 BUILDING AND AWAY FROM THE ADJACENT PROPERTY - FBC WPB
 107.2.5 SITE PLAN. THE CONSTRUCTION DOCUMENTS SUBMITTED
 WITH THE APPLICATION FOR PERMIT SHALL BE ACCOMPANIED BY
 A SITE PLAN SHOWING TO SCALE THE SIZE AND LOCATION OF
 NEW CONSTRUCTION AND EXISTING STRUCTURES ON THE SITE,
 DISTANCES FROM LOT LINES, THE ESTABLISHED STREET GRADES
 AND THE PROPOSED FINISHED GRADES, DEPICTING THE
 PROPOSED LOT DRAINAGE AND, AS APPLICABLE, FLOOD HAZARD
 AREAS, FLOODWAYS, AND DESIGN FLOOD ELEVATIONS; AND IT
 SHALL BE DRAWN IN ACCORDANCE WITH AN ACCURATE AND
 INCLUDED ON A BOUNDARY LINE SURVEY. (PLEASE PROVIDE CUT
 SECTIONS FOR ANY PROPOSED WATER RETAINING SWALES)

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2023-03-14 Cont ID  
Sent By rperdomo Date 2023-03-14 Time 12:25 Rev Time 0.00
Received By rperdomo Date 2023-03-14 Time 12:25 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2023-02-03 Cont ID  
Sent By rperdomo Date 2023-02-03 Time 13:04 Rev Time 0.00
Received By rperdomo Date 2023-02-03 Time 10:36 Sent To  
Notes
2023-02-03 13:04:21FLORIDA BUILDING CODE 2020 7TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED
 NFPA 70 2017 EDITION
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW
  
 1. PROVIDE LOAD CALCULATION AND PANEL SCHEDULE OF THE
 MAIL PANEL OR MAIL LOAD CENTER INCLUDING INCLUDING
 ADDITION AND POOL HOUSE. NEC 220.82, 408.4(A)
 2. PROVIDE INFORMATION OF THE SERVICE CONDUCTORS,
 GROUNDED CONDUCTORS, AND PROTECTIONS. NEC 230, 240, 250
 3. PROVIDE INFORMATION OF THE FEEDERS FOR SUBPANEL "A"
 (INCLUDING CONDUCTORS SIZES AND EGC). NEC 220, 310.15,
 250.122
  
 END OF COMMENTS
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
 RUBEN PEREZ PERDOMO, P.E.
 ELECTRICAL PLANS EXAMINER
 561-805-6738
 [email protected]
  

Review Stop ENG ENGINEERING CSD
Rev No 1 Status N Date 2023-04-25 Cont ID  
Sent By lquinone Date 2023-04-25 Time 13:13 Rev Time 0.00
Received By lquinone Date 2023-04-25 Time 13:13 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2023-05-31 Cont ID  
Sent By rmcphers Date 2023-05-31 Time 12:47 Rev Time 0.00
Received By rmcphers Date 2023-05-30 Time 08:27 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 5 Status P Date 2023-05-10 Cont ID  
Sent By rmcphers Date 2023-05-10 Time 14:30 Rev Time 0.00
Received By rmcphers Date 2023-05-09 Time 09:09 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2023-05-05 Cont ID  
Sent By rmcphers Date 2023-05-05 Time 08:42 Rev Time 0.00
Received By rmcphers Date 2023-05-04 Time 18:30 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2023-04-26 Cont ID  
Sent By aoliver Date 2023-04-26 Time 08:46 Rev Time 0.00
Received By aoliver Date 2023-04-13 Time 09:52 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2023-03-21 Cont ID  
Sent By asangele Date 2023-03-21 Time 14:41 Rev Time 0.00
Received By asangele Date 2023-03-21 Time 14:41 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2023-02-03 Cont ID  
Sent By jleahy Date 2023-02-03 Time 17:02 Rev Time 0.00
Received By jleahy Date 2023-01-25 Time 08:34 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2023-06-13 Cont ID  
Sent By aoliver Date 2023-06-13 Time 09:15 Rev Time 0.00
Received By aoliver Date 2023-05-10 Time 14:33 Sent To  
Notes
2023-06-13 09:14:17IMPACT FEE RECEIPT MU-2023-0022407-0000 $2,457.78 PAID
 -AO
2023-05-10 14:33:435/10/23 EMAILED IMPACT OFFICE TO REVIEW. LEM

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2023-02-02 Cont ID  
Sent By rmcphers Date 2023-02-02 Time 13:35 Rev Time 0.00
Received By rmcphers Date 2023-02-02 Time 13:35 Sent To  
Notes
2023-02-02 13:36:58PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF
  
 UPON APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE
 RECEIPT TO YOUR PROJECT OR EMAIL IT TO
 [email protected] .
  

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2023-04-24 Cont ID  
Sent By medwards Date 2023-04-24 Time 16:06 Rev Time 0.00
Received By medwards Date 2023-04-24 Time 16:06 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2023-03-07 Cont ID  
Sent By medwards Date 2023-03-07 Time 13:29 Rev Time 0.00
Received By medwards Date 2023-03-07 Time 13:29 Sent To  
Notes
2023-03-07 13:30:482ND ATTEMPT, SEE BELOW:
  
 1) PROVIDE A MECHANICAL DESIGN THAT WOULD INCLUDE A
 DRAWING WITH THE UNITS INSTALLED, THE CONDENSING UNIT
 TIED DOWN DETAIL, THE CONDENSATE DRAIN TERMINATION
 LOCATION AND THE SPEC SHEETS FOR THE MECHANICAL SYSTEM.
 FBC 107.3.5
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2023-01-27 Cont ID  
Sent By medwards Date 2023-01-27 Time 12:43 Rev Time 0.00
Received By medwards Date 2023-01-27 Time 12:43 Sent To  
Notes
2023-01-27 12:43:421ST REVIEW FMC
 PERMIT: 23011118
  
 CODES IN EFFECT: 2020
  
 FBC- FLORIDA BUILDING CODE
 FMC- FLORIDA MECHANICAL CODE
 FEC- FLORIDA ENERGY CONSERVATION
 FGC- FLORIDA FUEL GAS
 FEX- FLORIDA EXISTING BUILDING CODE
 FRC- FLORIDA RESIDENTIAL BUILDING CODE
 F.S.- FLORIDA STATUTES
 FAC- FLORIDA ACCESSIBILITY CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) PROVIDE A MECHANICAL DESIGN THAT WOULD INCLUDE A
 DRAWING WITH THE UNITS INSTALLED, THE CONDENSING UNIT
 TIED DOWN DETAIL, THE CONDENSATE DRAIN TERMINATION
 LOCATION AND THE SPEC SHEETS FOR THE MECHANICAL SYSTEM.
 FBC 107.3.5
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop P PLUMBING
Rev No 4 Status P Date 2023-05-05 Cont ID  
Sent By rwbrown Date 2023-05-05 Time 07:39 Rev Time 0.00
Received By rwbrown Date 2023-05-05 Time 07:39 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status F Date 2023-04-17 Cont ID  
Sent By rwbrown Date 2023-04-17 Time 10:13 Rev Time 0.00
Received By rwbrown Date 2023-04-17 Time 10:10 Sent To  
Notes
2023-04-17 10:13:263RD PLUMBING REVIEW
  
 THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED
 BY RYAN BROWN WITH THE FOLLOWING COMMENTS.
  
 1. DONE
  
  
 2. POOL HOUSE - 2020 FRC P3108.2.1 - THE SHOWER AND
 WATER CLOSET ARE BOTH UPSTREAM OF THE LAVATORY
 CONNECTION. ONLY ONE TRAPPED FIXTURE IS ALLOWED TO BE
 UPSTREAM OF THE VENTED FIXTURE'S CONNECTION TO THE
 HORIZONTAL BRANCH DRAIN BEING WET VENTED.
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
  
 RYAN W. BROWN
 CHIEF PLUMBING INSPECTOR
 OFFICE: 561-805-6692
 CELL: 561-517-4293
 EMAIL: [email protected]
  
  
 V7 FPC - 2020 FLORIDA PLUMBING CODE
 V7 FGC - 2020 FLORIDA FUEL GAS
 V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE
 V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE
 V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE
 V7 FEC - 2020 FLORIDA ENERGY CONSERVATION
 2021 F.S. - 2021 FLORIDA STATUTES
 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE
 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE
 FBC CHAPTER 1
  

Review Stop P PLUMBING
Rev No 2 Status F Date 2023-03-07 Cont ID  
Sent By rwbrown Date 2023-03-07 Time 06:36 Rev Time 0.00
Received By rwbrown Date 2023-03-07 Time 06:36 Sent To  
Notes
2023-03-07 06:37:382ND PLUMBING REVIEW
  
 THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED
 BY RYAN BROWN WITH THE FOLLOWING COMMENTS.
  
 1. COMMENT NOT ADDRESSED - THE KITCHEN SINK IS NOT A
 BATHROOM GROUP FIXTURE. ONLY BATHROOM GROUP FIXTURES
 ARE ALLOWED TO BE INCLUDED WITHIN THE WET VENT FOR THE
 BATHROOM. THE KITCHEN SINK MUST DISCHARGE DOWNSTREAM OF
 THE LAST BATHROOM GROUP FIXTURE BEING WET VENTED.
 POOL HOUSE DIAGRAM - 2020 FRC P3108.1 - THE KITCHEN
 SINK CANNOT BE THE VENTED FIXTURE THAT CREATES THE WET
 VENT FOR THE BATHROOM GROUP FIXTURES. THE KITCHEN SINK
 WOULD NEED TO DISCHARGE DOWNSTREAM OF THE WET VENT
 SYSTEM IF A WET VENT IS USED.
  
 2. ADDITIONAL COMMENT - ADDTION WASTE DIAGRAM - 2020
 FRC P3108.2.1 - THE TUB AND SHOWER ARE BOTH UPSTREAM OF
 THE LAVATORY CONNECTION. ONLY ONE TRAPPED FIXTURE IS
 ALLOWED TO BE UPSTREAM OF THE VENTED FIXTURE'S
 CONNECTION TO THE HORIZONTAL BRANCH DRAIN BEING WET
 VENTED.
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
  
 RYAN W. BROWN
 CHIEF PLUMBING INSPECTOR
 OFFICE: 561-805-6692
 CELL: 561-517-4293
 EMAIL: [email protected]
  
  
 V7 FPC - 2020 FLORIDA PLUMBING CODE
 V7 FGC - 2020 FLORIDA FUEL GAS
 V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE
 V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE
 V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE
 V7 FEC - 2020 FLORIDA ENERGY CONSERVATION
 2021 F.S. - 2021 FLORIDA STATUTES
 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE
 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE
 FBC CHAPTER 1
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2023-01-26 Cont ID  
Sent By rwbrown Date 2023-01-26 Time 11:29 Rev Time 0.00
Received By rwbrown Date 2023-01-26 Time 11:29 Sent To  
Notes
2023-01-26 11:31:361ST PLUMBING REVIEW
  
 THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED
 BY RYAN BROWN WITH THE FOLLOWING COMMENTS.
  
 1. 2020 FRC P3108.1 - THE KITCHEN SINK CANNOT BE THE
 VENTED FIXTURE THAT CREATES THE WET VENT FOR THE
 BATHROOM GROUP FIXTURES. THE KITCHEN SINK WOULD NEED TO
 DISCHARGE DOWNSTREAM OF THE WET VENT SYSTEM IF A WET
 VENT IS USED.
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
  
 RYAN W. BROWN
 CHIEF PLUMBING INSPECTOR
 OFFICE: 561-805-6692
 CELL: 561-517-4293
 EMAIL: [email protected]
  
  
 V7 FPC - 2020 FLORIDA PLUMBING CODE
 V7 FGC - 2020 FLORIDA FUEL GAS
 V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE
 V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE
 V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE
 V7 FEC - 2020 FLORIDA ENERGY CONSERVATION
 2021 F.S. - 2021 FLORIDA STATUTES
 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE
 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE
 FBC CHAPTER 1
  

Review Stop R ROOF PLAN REVIEW
Rev No 4 Status P Date 2023-05-05 Cont ID  
Sent By rmcphers Date 2023-05-05 Time 08:42 Rev Time 0.00
Received By rmcphers Date 2023-05-05 Time 08:42 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status P Date 2023-04-18 Cont ID  
Sent By rmcphers Date 2023-04-18 Time 15:45 Rev Time 0.00
Received By rmcphers Date 2023-04-18 Time 15:45 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status F Date 2023-03-08 Cont ID  
Sent By rmcphers Date 2023-03-08 Time 11:25 Rev Time 0.00
Received By rmcphers Date 2023-03-08 Time 11:25 Sent To  
Notes
2023-03-08 11:26:15SEE BUILDING PLAN REVIEW

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2023-02-02 Cont ID  
Sent By rmcphers Date 2023-02-02 Time 13:30 Rev Time 0.00
Received By rmcphers Date 2023-02-02 Time 13:30 Sent To  
Notes
2023-02-02 13:31:41SEE BUILDING PLAN REVIEW

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 6 Status P Date 2023-06-01 Cont ID  
Sent By rmcphers Date 2023-06-01 Time 08:00 Rev Time 0.00
Received By rmcphers Date 2023-06-01 Time 08:00 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 5 Status F Date 2023-05-31 Cont ID  
Sent By rmcphers Date 2023-05-31 Time 12:46 Rev Time 0.00
Received By rmcphers Date 2023-05-31 Time 12:46 Sent To  
Notes
2023-05-31 12:46:51SIGNATURE REVIEW
  
 CORRECTIONS NEEDED -
  
 1) REVISED DRAWING A1.0 DOES NOT SHOW AS DIGITALLY
 SIGNED BY THE ARCHITECT IN ADOBE READER - SIGNED AND
 SEALED DRAWINGS IN PROJECTDOX NEED TO BE
 DIGITALLY/ELECTRONICALLY SIGNED TO BE USED IN
 ELECTRONIC PLAN REVIEW. (A CERTIFICATE-BASED DIGITAL
 SIGNATURE (OFTEN JUST CALLED A DIGITAL SIGNATURE) IS A
 SPECIFIC TYPE OF E-SIGNATURE).

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 4 Status P Date 2023-05-05 Cont ID  
Sent By rmcphers Date 2023-05-05 Time 08:42 Rev Time 0.00
Received By rmcphers Date 2023-05-05 Time 08:42 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2023-04-18 Cont ID  
Sent By rmcphers Date 2023-04-18 Time 15:47 Rev Time 0.00
Received By rmcphers Date 2023-04-18 Time 15:47 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2023-03-08 Cont ID  
Sent By rmcphers Date 2023-03-08 Time 11:32 Rev Time 0.00
Received By rmcphers Date 2023-03-08 Time 11:31 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2023-02-02 Cont ID  
Sent By rmcphers Date 2023-02-02 Time 13:38 Rev Time 0.00
Received By rmcphers Date 2023-02-02 Time 13:38 Sent To  
Notes
2023-02-02 13:39:47SIGNATURE REVIEW
  
 CORRECTIONS NEEDED -
  
 1) DRAWING A-6.0 DOES NOT SHOW AS DIGITALLY SIGNED IN
 ADOBE READER -
  
 SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE
 DIGITALLY/ELECTRONICALLY SIGNED TO BE USED IN
 ELECTRONIC PLAN REVIEW. (A CERTIFICATE-BASED DIGITAL
 SIGNATURE (OFTEN JUST CALLED A DIGITAL SIGNATURE) IS A
 SPECIFIC TYPE OF E-SIGNATURE).
  

Review Stop Z ZONING
Rev No 3 Status P Date 2023-04-14 Cont ID  
Sent By asangele Date 2023-04-14 Time 17:32 Rev Time 0.00
Received By asangele Date 2023-04-14 Time 17:32 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2023-03-21 Cont ID  
Sent By asangele Date 2023-03-21 Time 14:41 Rev Time 0.00
Received By asangele Date 2023-03-21 Time 14:41 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2023-02-01 Cont ID  
Sent By ASangele Date 2023-02-01 Time 14:14 Rev Time 0.00
Received By asangele Date 2023-02-01 Time 14:14 Sent To  
Notes
2023-02-01 14:22:40FAILED
 2/1/2023
  
 A 240 OUTLET CANNOT BE INSTALLED BECAUSE A STOVE IS NOT
 ALLOWED TO BE INSTALLED
 PROPERTY DOESNT MEET THE MINIMUM STANDARDS TO HAVE A
 SECOND UNIT ON PROPERTY.
  
 ARTICLE III. SECTION 94-75
 MINIMUM LOT DIMENSIONS.
 A.LOT AREA FOR ONE OR TWO DWELLING UNITS: 6,000 SQUARE
 FEET;
 B.LOT AREAS FOR THREE OR MORE DWELLING UNITS: 3,000
 SQUARE FEET PER UNIT; NOT TO EXCEED A MAXIMUM OF 14.52
 DWELLING UNITS PER ACRE;
 C.LOT WIDTH: 60 FEET;
  
 PLEASE PROVIDE REAR SETBACK ON SITE PLAN
  
 ALEXIS SANGELEER
 PLANNER
 [email protected]
  
  