Plan Review Details - Permit 23010901
Plan Review Stops For Permit 23010901
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 3 Status P Date 2023-03-10 Cont ID  
Sent By aoliver Date 2023-03-10 Time 16:36 Rev Time 0.00
Received By aoliver Date 2023-03-10 Time 16:36 Sent To  
Notes
***NONE***

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 2 Status F Date 2023-03-09 Cont ID  
Sent By pvalenti Date 2023-03-09 Time 10:33 Rev Time 0.00
Received By pvalenti Date 2023-03-09 Time 06:51 Sent To  
Notes
2023-03-09 10:36:59PETER E VALENTI
 BUILDING PLANS EXAMINER II/INSPECTOR
 [email protected]
 561 805 6673
  
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC M = FBC MECHANICAL
 FBC FG = FBC FUEL GAS
  
 2ND ASBESTOS REVIEW DENIED:
  
 PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY. THIS LETTER IS REQUIRED PRIOR TO ISSUANCE
 OF PERMIT.
  
 ADDITIONAL INFORMATION REGARDING ASBESTOS REQUIREMENTS
 CAN BE FOUND ON THEIR WEBSITE:
  
 HTTPS://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVIC
 ES/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION
 -RENOVATION.HTML
  

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status F Date 2023-01-23 Cont ID  
Sent By pvalenti Date 2023-01-23 Time 09:33 Rev Time 0.00
Received By pvalenti Date 2023-01-23 Time 06:24 Sent To  
Notes
2023-01-23 09:35:51PETER E VALENTI
 BUILDING PLANS EXAMINER II/INSPECTOR
 [email protected]
 561 805 6673
  
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC M = FBC MECHANICAL
 FBC FG = FBC FUEL GAS
  
 ASBESTOS REVIEW DENIED:
  
 PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS
 REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE:
 HTTPS://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVIC
 ES/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION
 -RENOVATION.HTML
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2023-03-09 Cont ID  
Sent By pvalenti Date 2023-03-09 Time 10:37 Rev Time 0.00
Received By pvalenti Date 2023-03-09 Time 06:51 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2023-01-23 Cont ID  
Sent By pvalenti Date 2023-01-23 Time 15:28 Rev Time 0.00
Received By pvalenti Date 2023-01-23 Time 06:24 Sent To  
Notes
2023-01-23 17:36:31PETER E VALENTI
 BUILDING PLANS EXAMINER II/INSPECTOR
 [email protected]
 561 805 6673
  
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC M = FBC MECHANICAL
 FBC FG = FBC FUEL GAS
  
 BUILDING REVIEW DENIED:
  
 1.) FBC B 107.2.1, THE ORIENTATION OF STRUCTURE ON PLAN
 SHEETS: A-1/D-1, A-2, & E-1, APPEAR TO BE OPPOSITE OF
 NORTH INDICATER. PLEASE CONFIRM THAT THE ORIENTATION OF
 STRUCTURE ON PLAN SHEETS IS CORRECT AS IS, OR ADJUST
 THE STRUCTURES TO CORRELATE WITH THE DIRECTION
 INDICATER.
 2.) FBC B 303.3 & FBC B 304, COVER SHEET (CODE SECTION)
 STATES THAT THE OCCUPANCY FOR THEIS PROJECT IS B
 (BUSINESS), BUT APPEARS TO BE AN A-2. PLEASE REVIEW AND
 ADJUST OCCUPANCY.
 3.) FBC B 107.2.1 & TABLE FBC B 1004.1.2, THE OCCUPANCY
 LOAD CALCULATIONS ON THE PLAN COVER SHEET INDICATE THE
 DINING AREA TO BE AN ASSEMBLY AREA WITHOUT FIXED SEATS
 (15 S.F. PER PERSON). HOWEVER, THE PLAN SHEET A-1
 INDICATES ASSEMBLY AREA WITH FIXED SEATS OR WITHOUT
 FIXED SEATS CONCENTRATED. PLEASE CLARIFY THE TYPES OF
 ASSEMBLY SEATING ON PLAN SHEET A-1 AND REVIEW/ADJUST
 THE DINING AREA OCCUPANCY/OCCUPANTS ON THE COVERSHEET
 (OCCUPANCY LOAD CALCULATIONS SECTION).
 4.) FBC B TABLE 601/TABLE 705.4, FBC EB 504/505, THE
 ALTERATION LEVEL FROM THE FLORIDA EXISTING BUILDING HAS
 NOT BEEN IDENTIFIED ON THE COVER SHEET. PLEASE IDENTIFY
 THE ALTERATION LEVEL PER THE FLORIDA EXISTING BUILDING
 CODE AND REVIEW TABLE 601 OF THE FLORIDA BUILDING CODE
 AS THE FIRE RATING OF THE DIMIZING WALLS MAY NEED TO BE
 ADJUSTED.
 5.) FBC B 107.2.1 & FBC A 609.4, PLAN SHEET A-2 DETAIL
 4 IS NOT CLEAR AS TO THE HEIGHT REQUIREMENT OF
 ACCESSIBLE GRAB BARS. PLEASE CLARIFY ON THIS DETAIL.
 6.) FBC B 107.2.1 & FBC A 606.3, PLAN SHEET A-2 DETAIL
 3 IS NOT CLEAR AS TO MIRROR HEIGHT REQUIREMENTS AND
 SINK HEIGHT REQUIREMENTS. PLEASE CLARIFY ON THIS
 DETAIL.
 7.) FBC B 107.2.1 & FBC A 902.3, PLAN SHEET A-2 DETAIL
 6 IS NOT CLEAR AS TO ACCESSIBLE COUNTER TOP HEIGHT OF
 34". PLEASE CLARIFY ON THIS DETAIL.
 8.) FBC A 226.2, DISPERSION. DINING SURFACES AND WORK
 SURFACES SHALL BE DISPERSED THROUGHOUT THE SPACE OR
 FACILITY CONTAINING DINING SURFACES AND WORK SURFACES.
 PLEASE SHOW ACCESSIBLE SPACES IN EACH REQUIRED AREA.
 9.) FBC B 107.2.1, FBC A 226.2, FBC A 306.2, & FBC A
 306.3. ON PLAN SHEET A-1, THIS LOCATION APPEARS TO BE
 SET BACK IN A CORNER, DOES NOT APPEAR TO HAVE THE
 REQUIRED ACCESS/TURN AROUND SPACE, AND DOES NOT APPEAR
 TO HAVE THE REQUIRED KNEE & TOE SPACE. PLEASE SHOW A
 DIFFERENT LOCATION FOR ACCESSIBLE SPACE AT COUNTER. AND
 SHOW REQUIRED CLEARANCES.
 10.) FBC B 107.2.1, PLEASE PROVIDE
 DETAILS/SPECIFICATIONS FROM MANUFACTURER OF THE THE
 GLUE LAM BEAM PROPOSED ON PLAN SHEET A-1.
 11.) FBC B TABLE 2902.1, THE NUMBER OF PLUMBING
 FIXTURES APPEARS TO BE TOO LOW. PLEASE EVALUATE THE
 MINIMUM NUMBER REQUIRED PER FBC B TABLE 2902.1.

Review Stop E ELECTRICAL
Rev No 3 Status N Date 2023-04-04 Cont ID  
Sent By rperdomo Date 2023-04-04 Time 10:11 Rev Time 0.00
Received By rperdomo Date 2023-04-04 Time 10:11 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2023-04-04 Cont ID  
Sent By rperdomo Date 2023-03-06 Time 09:21 Rev Time 0.00
Received By rperdomo Date 2023-03-06 Time 09:21 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2023-02-02 Cont ID  
Sent By rperdomo Date 2023-02-02 Time 13:33 Rev Time 0.00
Received By rperdomo Date 2023-02-02 Time 12:32 Sent To  
Notes
2023-02-02 13:32:32FLORIDA BUILDING CODE 2020 7TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED
 NFPA 70 2017 EDITION
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW
  
 1. REVIEW INFORMATION ON THE PANEL SCHEDULE (EXIST.
 PANEL-A) FOR CORRECT RATING OF THE CIRCUIT BREAKERS AND
 BRANCH-CIRCUIT CONDUCTORS SIZE (WATER HEATER, AC UNIT).
 NEC 220, 240, 310.15
  
 END OF COMMENTS
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
 RUBEN PEREZ PERDOMO, P.E.
 ELECTRICAL PLANS EXAMINER
 561-805-6738
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2023-02-28 Cont ID  
Sent By pleduc Date 2023-02-28 Time   Rev Time 0.00
Received By pleduc Date 2023-02-28 Time 12:02 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2023-01-23 Cont ID  
Sent By pleduc Date 2023-01-23 Time   Rev Time 0.00
Received By pleduc Date 2023-01-23 Time 14:06 Sent To  
Notes
2023-01-23 14:25:07THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
  
 1) SHEET CVR - THERE IS AN INDICATION WITHIN THE CODE
 RESEARCH AREA OF BUSINESS OCCUPANCY.
  
 PER THE SUBMITTED CONSTRUCTION PLAN SHEETS THE
 OCCUPANCY IS AN ASSEMBLY OCCUPANCY PER NFPA 101 AND
 SHALL COMPLY WITH THAT CODE.
  
 3.3.196.2* ASSEMBLY OCCUPANCY. AN OCCUPANCY (1) USED
 FOR A
 GATHERING OF 50 OR MORE PERSONS FOR DELIBERATION,
 WORSHIP, ENTERTAIN MENT, EATING, DRINKING, AMUSEMENT,
 AWAITING TRANSPORTATION, OR
 SIMILAR USES; OR (2) USED AS A SPECIAL AMUSEMENT
 BUILDING, REGARDLESS OF OCCUPANT LOAD. (SAF-AXM)
  
 PLEASE REVIEW AND CORRECT.
  
  
  
 2) SHEET CVR - THERE IS AN INDICATION WITHIN THE CODE
 RESEARCH AREA OF EGRESS WIDTH AND 1 EXIT REQUIRED, I
 EXIT PROVIDED.
  
 PER THE SUBMITTED CONSTRUCTION PLAN SHEETS THERE ARE
 MULTIPLE EXITS PROVIDED AND PER NFPA 101 CH 12,
 ASSEMBLY OCCUPANCIES, MORE THAN 1 EXIT IS REQUIRED.
  
 12.2.4* NUMBER OF MEANS OF EGRESS
  
 12.2.4.1 THE NUMBER OF MEANS OF EGRESS SHALL BE IN
 ACCORDANCE WITH
 SECTION 7.4, OTHER THAN EXITS FOR FENCED OUTDOOR
 ASSEMBLY OCCUPANCIES
 IN ACCORDANCE WITH 12.2.4.4
  
 7.4.1 GENERAL.
 7.4.1.1 THE NUMBER OF MEANS OF EGRESS FROM ANY BALCONY,
 MEZZANINE,
 STORY, OR PORTION THEREOF SHALL BE NOT LESS THAN TWO,
 EXCEPT UNDER ONE OF
 THE FOLLOWING CONDITIONS:
 (1) A SINGLE MEANS OF EGRESS SHALL BE PERMITTED WHERE
 PERMITTED IN
 CHAPTERS 11 THROUGH 43.
 (2) A SINGLE MEANS OF EGRESS SHALL BE PERMITTED FOR A
 MEZZANINE OR
 BALCONY WHERE THE COMMON PATH OF TRAVEL LIMITATIONS OF
 CHAP TERS 11 THROUGH 43 ARE MET.
  
 CH 12 DOES NOT PROVIDE AN EXCEPTION FOR 1 EXIT.
  
 PLEASE REVIEW AND CORRECT.
  
  
  
 3) SHEET A 2 - THERE IS AN INDICATION OF A NEW BAR AS
 WELL AS AN AREA INDICATED AS DJ.
  
 PLEASE PROVIDE A CLEAR NARRATIVE OF WHAT THE THIS
 OCCUPANCY WILL FUNCTION AS, HOURS OF OPERATION, SPECIAL
 EVENT DETAILS, DANCE FLOOR AREA, ETC.
  
  
 4) SHEET A 2 - THE PROPOSED CONSTRUCTION PLAN MAY
 REQUIRE A FIRE ALARM AND FIRE SPRINKLER SYSTEM IF THE
 NARRATIVE AND BUSINESS MODEL OF THIS OCCUPANCY IS A
 "NIGHTCLUB".
  
 12.3.5 EXTINGUISHMENT REQUIREMENTS.
 12.3.5.1 THE FOLLOWING ASSEMBLY OCCUPANCIES SHALL BE
 PROTECTED
 THROUGHOUT BY AN APPROVED, SUPERVISED AUTOMATIC
 SPRINKLER SYSTEM IN
 ACCORDANCE WITH 9.7.1.1(1):
 (1) DANCE HALLS
 (2) DISCOTHEQUES
 (3) NIGHTCLUBS
 (4) ASSEMBLY OCCUPANCIES WITH FESTIVAL SEATING
  
 DEFINITION OF NIGHTCLUB
  
 : A PLACE OF ENTERTAINMENT OPEN AT NIGHT USUALLY
 SERVING FOOD AND LIQUOR AND PROVIDING MUSIC AND SPACE
 FOR DANCING AND OFTEN HAVING A FLOOR SHOW
  
 A FIRE ALARM WILL BE REQUIRED TO MONITOR THE FIRE
 SPRINKLER SYSTEM.
  
 PLEASE EVIEW AND PROVIDE THE APPLICABLE FA & FS
 DOCUMENTS.
  
  
  
 5) SHEET A 1 & A 2 - THERE AE NO INDICATIONS OF A DOOR
 SCHEDULE NOR THE TYPE OF LOCKS/LATCHES ON THE EXIT
 DOORS.
  
 PER NFPA 101 CH 12 & CH 7 MEANS OF EGRESS -
  
 12.2.2.2 DOORS.
 12.2.2.2.1 DOORS COMPLYING WITH 7.2.1 SHALL BE
 PERMITTED.
  
 12.2.2.2.4 LOCKING DEVICES COMPLYING WITH 7.2.1.5.5
 SHALL BE PERMITTED
 TO BE USED ON A SINGLE DOOR OR A SINGLE PAIR OF DOORS
 IF BOTH OF THE FOL LOWING CONDITIONS APPLY:
 (1) THE DOOR OR PAIR OF DOORS SERVE AS THE MAIN EXIT
 AND THE ASSEMBLY
 OCCUPANCY HAS AN OCCUPANT LOAD NOT GREATER THAN 500.
 (2) ANY LATCHING DEVICES ON SUCH A DOOR(S) FROM AN
 ASSEMBLY OCCU PANCY HAVING AN OCCUPANT LOAD OF 100 OR
 MORE ARE RELEASED BY
 PANIC HARDWARE OR FIRE EXIT HARDWARE
  
 PLEASE REVIEW AND PROVIDE DETAILS IN COMPLIANCE WITH
 THE REQUIREMENTS.
  
  
 6) SHEET A 1 & A 2 - THERE IS AN INDICATION OF A REAR
 PATIO AS WELLAS THE REAR EXIT DOUBLE DOOR THAT LEADS TO
 THE REAR PATIO.
  
 EXIT DISCHARGE IS REQUIRED TO LEAD TO A PUBLIC WAY.
  
 12.2.7 DISCHARGE FROM EXITS.
 12.2.7.1 EXIT DISCHARGE SHALL COMPLY WITH SECTION 7.7.
  
 7.7 DISCHARGE FROM EXITS
 7.7.1* EXIT TERMINATION. EXITS SHALL TERMINATE
 DIRECTLY, AT A PUBLIC
 WAY OR AT AN EXTERIOR EXIT DISCHARGE, UNLESS OTHERWISE
 PROVIDED IN 7.7.1.2
 THROUGH 7.7.1.4
  
 PLEASE PROVIDE DETAILS OF THE PATIO THAT LEADS TO A
 PUBLIC WAY INCLUDING ANY PROPOSED USE OF THE PATIO,
 SEATING PLANS, GATES/FENCING, DIMENSIONS, LIGHTING,
 CANOPIES, ETC.
  
  
 7) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET
 REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE
 ABOVE.
  
  
 8) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE
 RE-SUBMITTAL OF THE ABOVE.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2023-03-09 Cont ID  
Sent By pvalenti Date 2023-03-09 Time 10:38 Rev Time 0.00
Received By pvalenti Date 2023-02-27 Time 09:08 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2023-02-06 Cont ID  
Sent By lmarchan Date 2023-02-06 Time 08:21 Rev Time 0.00
Received By lmarchan Date 2023-01-20 Time 08:04 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2023-02-28 Cont ID  
Sent By ccole Date 2023-02-28 Time 11:37 Rev Time 0.00
Received By ccole Date 2023-02-28 Time 11:21 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2023-01-25 Cont ID  
Sent By ccole Date 2023-01-25 Time 17:28 Rev Time 0.00
Received By ccole Date 2023-01-25 Time 16:38 Sent To  
Notes
2023-01-25 17:29:091ST REVIEW FBC-2020 PLUMBING
 PERMIT- 23010901
 1/25/2023
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEETS A-1 & EP-1: THE SANITARY RISER SHOWS A
 VENT-TO-RIDGE ABOVE THE NEW HAND SINK WHICH DOES NOT
 APPEAR TO BE CORRECT GIVEN THE NEW SINK IS ADJACENT TO
 A HALF-WALL AND BAR COUNTER WHICH WOULD PROVIDE NO
 MEANS OF CONCEALING THE VENT PIPE RUN THROUGH THE OPEN
 AIR TO THE ROOF. PLEASE CLARIFY IF THIS IS THE DESIGN
 INTENTION OR A DESIGN ERROR- SEC. 107.2.1 WPB.
  
 2) EP-1: A SEPARATE PERMIT IS REQUIRED FOR THE GREASE
 INTERCEPTOR AND DUE TO A CHANGE IN PROCESS, THE
 PLUMBING REVIEW CANNOT BE APPROVED UNTIL AT A MINIMUM
 AN APPLICATION IS SUBMITTED.
  
 GREASE INTERCEPTOR PERMITS ARE REQUIRED TO BE SUBMITTED
 PRIOR TO APPROVAL OF THE MAIN PLUMBING PLANS. YOU CAN
 SUBMIT AN APPLICATION ???TBD??? (TO BE DETERMINED) IF
 YOU DO NOT HAVE A CONTRACTOR SELECTED BY EMAILING A
 COMPLETED PERMIT APPLICATION TO [email protected]
 . YOU WILL RECEIVE INSTRUCTIONS TO PAY FEES AND UPLOAD
 PLANS. YOU MAY UPLOAD PLANS AND PAY FEES AT A FUTURE
 DATE, BUT THE APPLICATION IS REQUIRED AT THIS TIME. WE
 RECOMMEND THAT YOU PAY FEES AND UPLOAD PLANS AT THE
 SAME TIME. AFTER YOU HAVE THE PERMIT(S) GENERATED,
 NOTIFY ME VIA EMAIL AND I WILL CHANGE THE REVIEW STATUS
 TO PASS.
  
 3) EP1: THE GREASE INTERCEPTOR SHALL ALSO BE REVIEWED
 UNDER THIS MASTER PERMIT. PLEASE PROVIDE THE FOLLOWING
 ITEMS.
 A) MANUFACTURER'S SPECIFICATIONS- SECS.1003.3.5 OR
 1003.3.7 FBC P.
 B) EQUIPMENT SCHEDULE INDICATING THE MAKE, MODEL AND
 CAPACITY OF THE UNIT.
 C) SIZING CALCULATIONS IN ACCORDANCE WITH ASME
 A112.14.3, ASME A112.14.4, ASME A112.14.6, CSA B481.3,
 OR PDI G101 FOR HYDROMECHANICAL TYPES; OR SEC. 1003.3.7
 FOR GRAVITY TYPES.
 D) REVISE THE ISOMETRIC DRAWING OR PROVIDE AN ENLARGED
 INTERCEPTOR PIPING DIAGRAM. THE DIAGRAM SHALL SHOW THE
 LOCATIONS AND SIZES OF INLETS, OUTLETS, VENTS,
 CLEANOUTS, AND FLOW CONTROL VENTING WHERE REQUIRED BY
 THE MANUFACTURER.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2023-02-28 Cont ID  
Sent By ccole Date 2023-02-28 Time 11:37 Rev Time 0.00
Received By ccole Date 2023-02-28 Time 11:37 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2023-01-23 Cont ID  
Sent By pvalenti Date 2023-01-23 Time 09:43 Rev Time 0.00
Received By pvalenti Date 2023-01-23 Time 06:32 Sent To  
Notes
***NONE***