Plan Review Details - Permit 23010830
Plan Review Stops For Permit 23010830
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2023-03-09 Cont ID  
Sent By jbrooks Date 2023-03-09 Time 11:02 Rev Time 0.00
Received By jbrooks Date 2023-03-09 Time 07:57 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2023-02-28 Cont ID  
Sent By jbrooks Date 2023-02-28 Time 12:24 Rev Time 0.00
Received By jbrooks Date 2023-02-28 Time 08:02 Sent To  
Notes
2023-02-28 12:25:37JONATHAN BROOKS JR.
 BUILDING PLANS EXAMINER
 WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM
 PHONE (561) 805-6656
 EMAIL: [email protected]
  
 1ST REVIEW: FBC 2020 7TH EDITION
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
 TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT
 CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX.
  
 1. FBC B 107.2.1 SUBMITTED PRODUCT APPROVAL FL14317-R13
 COVERS MULTIPLE ATTACHMENT LIMITATIONS. SELECT
 ATTACHMENT LIMITATION SYSTEM USED FROM 5.8.3.1
 DIRECT-TO-DECK PAGES #4 OR #5. SYSTEM SELECTED MUST
 MEET OR EXCEED -70 MAXIMUM DESIGN PRESSURE. ALL
 APPLICABLE DETAILS AND ATTACHMENTS MUST BE CLEARLY
 IDENTIFIED ON THE PRODUCT APPROVAL DRAWINGS. THIRD
 REQUEST.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2023-02-03 Cont ID  
Sent By jbrooks Date 2023-02-03 Time 11:19 Rev Time 0.00
Received By jbrooks Date 2023-02-03 Time 08:04 Sent To  
Notes
2023-02-03 11:20:32JONATHAN BROOKS JR.
 BUILDING PLANS EXAMINER
 WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM
 PHONE (561) 805-6656
 EMAIL: [email protected]
  
 1ST REVIEW: FBC 2020 7TH EDITION
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
 TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT
 CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX.
  
 1. FBC B 107.2.1 SUBMITTED PRODUCT APPROVAL FL14317-R13
 COVERS MULTIPLE ATTACHMENT LIMITATIONS. SELECT
 ATTACHMENT LIMITATION SYSTEM USED FROM 5.8.3.1
 DIRECT-TO-DECK PAGES #4 OR #5. SYSTEM SELECTED MUST
 MEET OR EXCEED -70 MAXIMUM DESIGN PRESSURE. ALL
 APPLICABLE DETAILS AND ATTACHMENTS MUST BE CLEARLY
 IDENTIFIED ON THE PRODUCT APPROVAL DRAWINGS. SECOND
 REQUEST.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2023-01-23 Cont ID  
Sent By jbrooks Date 2023-01-23 Time 11:26 Rev Time 0.00
Received By jbrooks Date 2023-01-23 Time 08:02 Sent To  
Notes
2023-01-23 11:27:12JONATHAN BROOKS JR.
 BUILDING PLANS EXAMINER
 WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM
 PHONE (561) 805-6656
 EMAIL: [email protected]
  
 1ST REVIEW: FBC 2020 7TH EDITION
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
 TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT
 CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX.
  
 1. FBC B 107.2.1 SUBMITTED PRODUCT APPROVAL FL22854-R1
 IS NOT APPROVED FOR USE OUTSIDE HVHZ. CITY OF WEST PALM
 BEACH IS NOT LOCATED IN A HVHZ. YOU MIGHT CONSIDER
 USING FL7473-R9.
 2. FBC B 107.2.1 SUBMITTED PRODUCT APPROVAL FL14317-R13
 COVERS MULTIPLE ATTACHMENT LIMITATIONS. SELECT
 ATTACHMENT LIMITATION SYSTEM USED FROM 5.8.3.1
 DIRECT-TO-DECK PAGES #4 OR #5. SYSTEM SELECTED MUST
 MEET OR EXCEED -70 MAXIMUM DESIGN PRESSURE. ALL
 APPLICABLE DETAILS AND ATTACHMENTS MUST BE CLEARLY
 IDENTIFIED ON THE PRODUCT APPROVAL DRAWINGS.
 3. FBC R 301 FAC9N-3 SUBMITTED FLORIDA DBPR PRODUCT
 APPROVAL FL14826-R6 COVERS MULTIPLE DESIGN PRESSURE
 RATINGS. PLEASE SELECT CORRECT PLYWOOD SPECIES GROUP,
 ANCHOR QUANTITY PAGE #1 OF THE INSTALLATION
 INSTRUCTIONS THAT MEET OR EXCEED THE MINIMUM DESIGN
 PRESSURE REQUIREMENT FOR ZONE 3 EXPOSURE CATEGORY C
 AREAS. (-70). ALL APPLICABLE DETAILS AND ATTACHMENTS
 MUST BE CLEARLY IDENTIFIED ON THE PRODUCT APPROVAL
 DRAWINGS. DETAILS AND ATTACHMENTS NOT SPECIFICALLY
 COVERED IN PRODUCT APPROVALS WILL NEED SITE-SPECIFIC
 ENGINEERING.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2023-03-09 Cont ID  
Sent By jbrooks Date 2023-03-09 Time 11:02 Rev Time 0.00
Received By jbrooks Date 2023-03-01 Time 16:04 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2023-02-28 Cont ID  
Sent By jbrooks Date 2023-02-28 Time 12:25 Rev Time 0.00
Received By jbrooks Date 2023-02-14 Time 07:04 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2023-02-03 Cont ID  
Sent By jbrooks Date 2023-02-03 Time 11:22 Rev Time 0.00
Received By jbrooks Date 2023-01-23 Time 13:53 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2023-01-23 Cont ID  
Sent By jbrooks Date 2023-01-23 Time 11:27 Rev Time 0.00
Received By jbrooks Date 2023-01-20 Time 09:47 Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy