Plan Review Stops For Permit 23010434 |
Review Stop |
AD |
ADDRESSING |
Rev No |
2 |
Status |
P |
Date |
2023-03-22 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2023-03-22 |
Time |
13:35 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2023-03-22 |
Time |
13:35 |
Sent To |
|
|
Notes |
2023-03-22 13:36:18 | THE BUILDING TO BE DEMOLISHED DOESN'T HAVE IT'S OWN | | ADDRESS, PRIMARY ADDRESS OF 1501 N AUSTRALIAN AVE OK | | FOR PROJECT. |
|
|
Review Stop |
AD |
ADDRESSING |
Rev No |
1 |
Status |
F |
Date |
2023-01-31 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2023-01-31 |
Time |
08:24 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2023-01-31 |
Time |
08:24 |
Sent To |
|
|
Notes |
2023-01-31 08:36:51 | PLEASE CONTACT [email protected] OR CALL | | 561-805-6659 TO DISCUSS ADDRESSING THE BUILDING |
|
|
Review Stop |
AIPP |
ART IN PUBLIC PLACES |
Rev No |
1 |
Status |
P |
Date |
2023-03-01 |
|
|
Cont ID |
|
Sent By |
swelter |
Date |
2023-03-01 |
Time |
13:31 |
Rev Time |
0.00 |
Received By |
swelter |
Date |
2023-03-01 |
Time |
13:33 |
Sent To |
|
|
Notes |
2023-03-01 13:33:23 | WORKING WITH PARKS AND RECREATION ON PUBLIC ART |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2023-05-11 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2023-05-11 |
Time |
08:37 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2023-05-11 |
Time |
08:37 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2023-04-18 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2023-04-18 |
Time |
11:40 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2023-04-18 |
Time |
11:38 |
Sent To |
|
|
Notes |
2023-04-18 11:40:32 | TENNIS CENTER | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected] | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | AMENDMENT | | | | CORRECTIONS NEEDED - | | | | 1) DRAWINGS - COV-1, S-2.2.0, S-2.3.0, S-2.4.0, | | S-2.5.0, SP-2 DO NOT SHOW AS DIGITALLY SIGNED IN ADOBE | | READER - SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED | | TO BE DIGITALLY/ELECTRONICALLY SIGNED TO BE USED IN | | ELECTRONIC PLAN REVIEW. (A CERTIFICATE-BASED DIGITAL | | SIGNATURE (OFTEN JUST CALLED A DIGITAL SIGNATURE) IS A | | SPECIFIC TYPE OF E-SIGNATURE). |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2023-03-24 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2023-03-24 |
Time |
11:18 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2023-03-24 |
Time |
11:18 |
Sent To |
|
|
Notes |
2023-03-24 11:18:35 | TENNIS CENTER | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected] | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | AMENDMENT | | | | CORRECTIONS NEEDED - | | | | 1) DRAWINGS - COV-1, GN-1, DM-1, DM-2, DM-3, PGD-1, | | PGD-2, PGD-3, UT-1,UT-2, UT-3, DET-1,DET-2,DET-3, HD-1, | | HD-2, HD-3, HD-4, LT-1, LT-2, LT-3 AND ALL OF THE | | STRUCTURAL DRAWINGS DO NOT SHOW AS DIGITALLY SIGNED IN | | ADOBE READER - SIGNED AND SEALED DRAWINGS IN PROJECTDOX | | NEED TO BE DIGITALLY/ELECTRONICALLY SIGNED TO BE USED | | IN ELECTRONIC PLAN REVIEW. (A CERTIFICATE-BASED DIGITAL | | SIGNATURE (OFTEN JUST CALLED A DIGITAL SIGNATURE) IS A | | SPECIFIC TYPE OF E-SIGNATURE). |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2023-02-27 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2023-02-27 |
Time |
16:38 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2023-02-27 |
Time |
16:20 |
Sent To |
|
|
Notes |
2023-02-27 16:31:28 | TENNIS CENTER | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected] | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | AMENDMENT | | | | CORRECTIONS NEEDED - | | | | 1) PLEASE PROVIDE A SOIL REPORT. FBC 1803.1 | | | | 2) PLEASE SHOW THE STRUCTURAL STEEL ROOF DECK | | ATTACHMENTS - TYPE AND ON CENTER SPACING - FBC 1609.5.1 | | | | 3) PRODUCT APPROVAL FL17682 R6 FOR THE SWING DOOR - THE | | FRONT PAGE OF THE PRODUCT APPROVAL SAYS - "PENDING | | APPROVAL" THE STATUS SHOULD SAY "APPROVED". | | | | 4) SEPARATE PERMITS ARE REQUIRED FOR - EXISTING | | BUILDING DEMOLITION, BENCH SHADE STRUCTURE, PICNIC AREA | | SHADE STRUCTURE, SITE LIGHTING, TENNIS COURTS, FENCES. | | | | 5) DRAWINGS - COV-1, GN-1, DM-1, DM-2, DM-3, PGD-1, | | PGD-2, PGD-3, UT-1,UT-2, UT-3, DET-1,DET-2,DET-3, HD-1, | | HD-2, HD-3, HD-4, LT-1, LT-2, LT-3 AND ALL OF THE | | STRUCTURAL DRAWINGS DO NOT SHOW AS DIGITALLY SIGNED IN | | ADOBE READER - SIGNED AND SEALED DRAWINGS IN PROJECTDOX | | NEED TO BE DIGITALLY/ELECTRONICALLY SIGNED TO BE USED | | IN ELECTRONIC PLAN REVIEW. (A CERTIFICATE-BASED DIGITAL | | SIGNATURE (OFTEN JUST CALLED A DIGITAL SIGNATURE) IS A | | SPECIFIC TYPE OF E-SIGNATURE). |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2023-05-09 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2023-05-09 |
Time |
11:31 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2023-05-09 |
Time |
11:17 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2023-02-21 |
|
|
Cont ID |
|
Sent By |
mpeterso |
Date |
2023-02-21 |
Time |
15:08 |
Rev Time |
0.00 |
Received By |
mpeterso |
Date |
2023-02-21 |
Time |
15:08 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E-LOWVOLT |
ELECTRICAL LOW VOLTAGE |
Rev No |
1 |
Status |
P |
Date |
2023-05-09 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2023-05-09 |
Time |
12:10 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2023-05-09 |
Time |
12:10 |
Sent To |
|
|
Notes |
2023-05-09 12:11:23 | VOICE AND DATA AS PER PLANS JLEAHY |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
3 |
Status |
P |
Date |
2023-05-19 |
|
|
Cont ID |
|
Sent By |
lquinone |
Date |
2023-05-19 |
Time |
15:21 |
Rev Time |
0.00 |
Received By |
lquinone |
Date |
2023-05-19 |
Time |
15:21 |
Sent To |
|
|
Notes |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
2 |
Status |
P |
Date |
2023-04-21 |
|
|
Cont ID |
|
Sent By |
lquinone |
Date |
2023-04-21 |
Time |
15:24 |
Rev Time |
0.00 |
Received By |
lquinone |
Date |
2023-04-21 |
Time |
15:24 |
Sent To |
|
|
Notes |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
1 |
Status |
P |
Date |
2023-01-30 |
|
|
Cont ID |
|
Sent By |
rrossano |
Date |
2023-01-30 |
Time |
|
Rev Time |
|
Received By |
rrossano |
Date |
2023-01-30 |
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2023-01-27 |
|
|
Cont ID |
|
Sent By |
cwalker |
Date |
2023-01-27 |
Time |
|
Rev Time |
|
Received By |
cwalker |
Date |
2023-01-27 |
Time |
|
Sent To |
|
|
Notes |
2023-01-27 14:09:42 | FIRE REVIEW COMMENTS: | | | | LIFE SAFETY SYSTEM WORK (FIRE SPRINKLER AND/OR FIRE | | ALARM) SHALL BE PERFORMED UNDER SEPARATE PERMITS AND | | SHOP DRAWINGS BY PROPERLY QUALIFIED CONTRACTORS. | | | | C. WALKER | | | | 561-804-4762 | | | | [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2023-05-22 |
|
|
Cont ID |
|
Sent By |
aoliver |
Date |
2023-05-22 |
Time |
12:05 |
Rev Time |
0.00 |
Received By |
aoliver |
Date |
2023-05-10 |
Time |
17:48 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2023-05-09 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2023-05-09 |
Time |
12:11 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2023-04-14 |
Time |
08:29 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2023-04-10 |
|
|
Cont ID |
|
Sent By |
aoliver |
Date |
2023-04-10 |
Time |
07:40 |
Rev Time |
0.00 |
Received By |
aoliver |
Date |
2023-03-20 |
Time |
07:57 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2023-03-02 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2023-03-02 |
Time |
08:12 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2023-01-25 |
Time |
11:10 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
P |
Date |
2023-06-02 |
|
|
Cont ID |
|
Sent By |
aoliver |
Date |
2023-06-02 |
Time |
16:44 |
Rev Time |
0.00 |
Received By |
aoliver |
Date |
2023-05-22 |
Time |
12:10 |
Sent To |
|
|
Notes |
2023-05-22 12:11:22 | EMAILED IMPACT FOR REVIEW-AO |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2023-02-27 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2023-02-27 |
Time |
16:33 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2023-02-27 |
Time |
16:33 |
Sent To |
|
|
Notes |
2023-02-27 16:37:54 | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF | | | | UPON APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE | | RECEIPT TO YOUR PROJECT OR EMAIL IT TO | | [email protected] . | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
4 |
Status |
P |
Date |
2023-05-11 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2023-05-11 |
Time |
13:06 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2023-05-11 |
Time |
13:06 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
F |
Date |
2023-05-02 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2023-05-02 |
Time |
16:52 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2023-05-02 |
Time |
16:52 |
Sent To |
|
|
Notes |
2023-05-02 16:54:32 | THE ADJUSTED VENTILATION CALCULATIONS WERE NOT IN TIS | | SUBMITTAL. PLEASE SUBMIT THESE IN THE NEXT REVIEW | | CYCLE. FMC TABLE 403.3.1.1 | | | | MICHAEL EDWARDS | | MECHANICAL EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL. 33401 | | 561-805-6728 | | [email protected] | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2023-04-07 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2023-04-07 |
Time |
13:46 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2023-04-07 |
Time |
13:46 |
Sent To |
|
|
Notes |
2023-04-07 13:46:45 | 1ST REVIEW FMC | | PERMIT: 23010434 | | | | CODES IN EFFECT: 2020 | | | | FBC- FLORIDA BUILDING CODE | | FMC- FLORIDA MECHANICAL CODE | | FEC- FLORIDA ENERGY CONSERVATION | | FGC- FLORIDA FUEL GAS | | FEX- FLORIDA EXISTING BUILDING CODE | | FRC- FLORIDA RESIDENTIAL BUILDING CODE | | F.S.- FLORIDA STATUTES | | FAC- FLORIDA ACCESSIBILITY CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) THE BATHROOM EXHAUST SHALL MEET FMC TABLE 403.3.1.1 | | WHICH IS 50 CFM PER WATER CLOSET OR URINAL IF THE FAN | | RUNS CONTINUOUSLY WHILE OCCUPIED OR 70 CFM PER WATER | | CLOSET OR URINAL IF THE FAN RUNS INTERMITTENTLY. PLEASE | | SPECIFY THE DESIGN OF THE EXHAUST FAN FOR THE | | BATHROOMS. ALSO, THE CFM???S REQUIRED IF THE FAN RUNS | | CONTINUOUSLY IS 750 CFM. EF-2 IS 700 CFM PLEASE MAKE | | SURE THE EF-2 MEETS THE MINIMUM EXHAUST REQUIREMENTS | | FOR THE BATHROOM EXHAUST. | | | | 2) THIS COMMENT WAS NOT ADDRESSED IN THE FIRST CYCLE | | RESUBMITTAL: PROVIDE DETAILS FOR THE WARMING KITCHEN, | | INCLUDE ALL COOKING AND WARMING APPLIANCES. FBC 107.3.5 | | | | 3) THE OUTDOOR AIR CALCULATION SHOULD BE ADJUSTED FOR | | THE CORRECTED OCCUPANT COUNT TAKEN FROM FMC TABLE | | 403.3.1.1 AND NOT THE ARCHITECT???S OCCUPANT COUNT. FMC | | 403.3.1.1 3RD SENTENCE. | | | | CLASSROOM SHOULD BE 8 OCCUPANTS | | MULTIPURPOSE ASSEMBLY SHOULD BE 66 OCCUPANTS | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM. | | | | MICHAEL EDWARDS | | MECHANICAL EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL. 33401 | | 561-805-6728 | | [email protected] | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2023-02-17 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2023-02-17 |
Time |
11:44 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2023-02-17 |
Time |
11:44 |
Sent To |
|
|
Notes |
2023-02-17 11:45:08 | 1ST REVIEW FMC | | PERMIT: 23010434 | | | | CODES IN EFFECT: 2020 | | | | FBC- FLORIDA BUILDING CODE | | FMC- FLORIDA MECHANICAL CODE | | FEC- FLORIDA ENERGY CONSERVATION | | FGC- FLORIDA FUEL GAS | | FEX- FLORIDA EXISTING BUILDING CODE | | FRC- FLORIDA RESIDENTIAL BUILDING CODE | | F.S.- FLORIDA STATUTES | | FAC- FLORIDA ACCESSIBILITY CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | PLAN REVIEW RESULTS: DENIED. | | A COMPLETE REVIEW COULD NOT BE COMPLETED AS THERE WERE | | DOCUMENTS MISSING FROM THIS SUBMITTAL. | | | | 1 PROVIDE THE ENERGY CALCULATIONS. FEC C402 | | | | 2) PROVIDE THE MECHANICAL EQUIPMENT SIZING | | CALCULATIONS. FEC C403.2.1 | | | | 3) PROVIDE THE OUTDOOR AIR CALCULATIONS FOR EACH USE OF | | SPACE IN THIS BUILDING. FMC 403.3.1.1 AND TABLE | | 403.3.1.1 | | | | 4) PROVIDE DETAILS FOR THE WARMING KITCHEN, INCLUDING | | ALL COOKING AND WARMING APPLIANCES. FBC 107.3.5 | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM. | | | | MICHAEL EDWARDS | | MECHANICAL EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL. 33401 | | 561-805-6728 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2023-04-24 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2023-04-24 |
Time |
12:06 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2023-04-24 |
Time |
11:19 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2023-04-06 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2023-04-06 |
Time |
15:29 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2023-04-06 |
Time |
07:12 |
Sent To |
|
|
Notes |
2023-04-06 15:29:41 | 2ND REVIEW FBC-2020 PLUMBING | | PERMIT- 23010434 | | 4/6/2023 | | CODES IN EFFECT: | | | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020 | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | PLAN REVIEW RESULTS: DENIED. FAILED COMMENTS FROM THE | | 1ST REVIEW ARE LISTED BELOW WITH SOME ADDITIONAL NOTES. | | | | 1) 2ND REQUEST. PLEASE NOTE A SEPARATE PERMIT IS | | REQUIRED FOR THE POTABLE WATER SERVICE BACKFLOW | | PREVENTER AND THE PERMIT APPLICATION FOR THE DEVICE | | SHALL BE SUBMITTED PRIOR TO PLUMBING PLAN APPROVAL FOR | | THE BUILDING. YOU CAN SUBMIT AN APPLICATION TBD (TO BE | | DETERMINED) IF YOU DO NOT HAVE A CONTRACTOR SELECTED BY | | EMAILING A COMPLETED PERMIT APPLICATION TO | | [email protected]. YOU WILL RECEIVE INSTRUCTIONS | | TO PAY FEES AND UPLOAD PLANS. YOU MAY UPLOAD PLANS AND | | PAY FEES AT A FUTURE DATE, BUT THE APPLICATION IS | | REQUIRED AT THIS TIME. WE RECOMMEND THAT YOU PAY FEES | | AND UPLOAD PLANS AT THE SAME TIME. AFTER YOU HAVE THE | | PERMIT GENERATED, NOTIFY ME VIA EMAIL AND I WILL CHANGE | | THE REVIEW STATUS TO PASS. | | | | | | 8) 2ND REQUEST. P2.1.0 & P.2.2: INDICATE THE MEANS OF | | PROVIDING TEMPERED WATER DELIVERY FROM THE PUBLIC | | LAVATORIES- SEC. 419.5 FBC P. PLEASE NOTE TEMPERED | | WATER MIXING VALVES SHALL CONFORM TO ASSE 1070- SEC. | | 607.1.2 FBC P. | | | | THE ARCHITECT???S RESPONSE TO THE COMMENT INDICATES THE | | MASTER THERMOSTATIC MIXING VALVE IS SUPPLYING THE | | TEMPERED WATER. AS PREVIOUSLY NOTED TEMPERED WATER | | MIXING VALVES SHALL CONFORM TO ASSE 1070- SEC. 607.1.2 | | FBC P. THE MANUFACTURER???S SPECIFICATIONS FOR THE | | SELECTED MASTER THERMOSTATIC MIXING VALVE INDICATE | | CONFORMANCE TO ASSE 1017. PLEASE PROVIDE POINT OF USE | | MIXING VALVES AT THE LAVATORIES. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. | | | | CHRISTOPHER L. COLE | | MECHANICAL/PLUMBING PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2023-02-03 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2023-02-03 |
Time |
13:35 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2023-02-02 |
Time |
16:41 |
Sent To |
|
|
Notes |
2023-02-03 13:37:36 | 1ST REVIEW FBC-2020 PLUMBING | | PERMIT- 23010434 | | CODES IN EFFECT: | | | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020 | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) PLEASE NOTE A SEPARATE PERMIT IS REQUIRED FOR THE | | POTABLE WATER SERVICE BACKFLOW PREVENTER AND THE PERMIT | | APPLICATION FOR THE DEVICE SHALL BE SUBMITTED PRIOR TO | | PLUMBING PLAN APPROVAL FOR THE BUILDING. YOU CAN SUBMIT | | AN APPLICATION TBD (TO BE DETERMINED) IF YOU DO NOT | | HAVE A CONTRACTOR SELECTED BY EMAILING A COMPLETED | | PERMIT APPLICATION TO [email protected]. YOU WILL | | RECEIVE INSTRUCTIONS TO PAY FEES AND UPLOAD PLANS. YOU | | MAY UPLOAD PLANS AND PAY FEES AT A FUTURE DATE, BUT THE | | APPLICATION IS REQUIRED AT THIS TIME. WE RECOMMEND THAT | | YOU PAY FEES AND UPLOAD PLANS AT THE SAME TIME. AFTER | | YOU HAVE THE PERMIT GENERATED, NOTIFY ME VIA EMAIL AND | | I WILL CHANGE THE REVIEW STATUS TO PASS. | | | | 2) PLEASE NOTE SEPARATE PERMITS ARE REQUIRED FOR BOTH | | THE IRRIGATION SYSTEM AND THE SYSTEM BACKFLOW | | PREVENTER, HOWEVER THESE PERMITS MAY BE SUBMITTED AT A | | LATER DATE AND WILL NOT IMPACT ISSUANCE OF THE MAIN | | BUILDING PERMIT- SECS. 105.1 & 107.2.1 WPB. | | | | 3) SHEETS P2.1.0 & P.2.2.0: PLEASE CORRECT THE SANITARY | | VENTING PER ITEMS A & B- FBC P. | | | | A) THE EWC1 FIXTURE DRAIN CANNOT BE VENTED BY THE L1 | | COMMON DRY VENT FOR THE BATHROOM HORIZONTAL WET VENT | | SYSTEM- SECS. 912.1 & 912.2.1. AN INDIVIDUAL VENT IS | | REQUIRED FOR THE EWC1 AND THE FIXTURE DRAIN SHALL | | CONNECT TO THE BUILDING DRAIN DOWNSTREAM OF THE | | BATHROOM HORIZONTAL WET VENT CONNECTION. | | | | B) THE FIXTURE DRAIN FOR SH1 IN WOMEN'S SHOWER IS NOT | | BEING VENTED BY THE BATHROOM WET VENT BRANCH UPSTREAM | | OF IT AND IS MAKING AN INDIVIDUAL CONNECTION TO THE | | BUILDING DRAIN. EITHER RELOCATE THE DRAIN CONNECTION TO | | THE BRANCH DRAIN OR PROVIDE AN INDIVIDUAL VENT- SECS. | | 910.1 & 912.1. | | | | 4) P2.1.0 & P.2.2.0: PROVIDE TRAP SEAL PROTECTION FOR | | THE FLOOR DRAINS- SEC. 1002.4.1.1 FBC P. | | | | 5) P2.1.0 & P.2.2.0: SHOW THE LOCATION OF THE REQUIRED | | EWH THERMAL EXPANSION CONTROL DEVICE AND PIPING | | CONNECTION- SEC. 607.3 FBC P. | | | | 6) P2.1.0 & P2.2.0: DETAIL EWH RELIEF VALVE DISCHARGE | | SYSTEM- DISCHARGE PIPE, PAN, PAN DRAIN PIPE, AND DRAIN | | TERMINATION LOCATION- SECS. 504.4- 504.7.2 FBC P. | | | | 7) P2.0.0: PLEASE PROVIDE AN EQUIPMENT SCHEDULE FOR THE | | MASTER THERMOSTATIC MIXING VALVE- SEC. 607.1.1 & 613.1 | | FBC P. | | | | 8) P2.1.0 & P.2.2: INDICATE THE MEANS OF PROVIDING | | TEMPERED WATER DELIVERY FROM THE PUBLIC LAVATORIES- | | SEC. 419.5 FBC P. PLEASE NOTE TEMPERED WATER MIXING | | VALVES SHALL CONFORM TO ASSE 1070- SEC. 607.1.2 FBC P. | | | | 9) P2.1.0 & P.2.2: THE 1/2-INCH FIXTURE SUPPLY PIPES TO | | THE LAVATORIES ARE EXCEEDING THEIR MAXIMUM ALLOWABLE | | LENGTHS BASED ON TABLE C404.5.1 FBC ENERGY. PROVIDE | | EITHER A RECIRCULATION PUMP FOR THE SYSTEM WITH | | RECIRCULATION LOOPS TO THE LAVS, OR POINT OF USE WATER | | HEATERS AT EACH LAV LOCATION. | | | | 10) SHEETS A-2.1.3, P2.1.0 P.2.2.0: PLEASE PROVIDE ROOF | | DRAINAGE GPM FLOW CALCULATIONS BASED ON THE RATE FALL | | RATE AND ROOF SQUARE FOOT AREAS- SECS. 1106.1 & 1106.2 | | FBC P. | | | | 11) P2.1.0: THE PLAN SHOWS A WARMING KITCHEN WITH A | | SINK. PLEASE DETAIL WHAT TYPE OF FOOD PREP OR COOKING | | OPERATIONS WILL BE CONDUCTED IN THE KITCHEN IN ORDER TO | | DETERMINE IF GREASE WASTE REMOVAL WILL BE REQUIRED- | | REFER TO SECS. 1003.3.1 FBC P. | | | | 12) A2.1.1 & P2.0.0: THE WIDTHS OF THE STANDARD WATER | | CLOSET COMPARTMENTS SHALL BE 30-INCHES, AND THE DEPTHS | | SHALL BE 60-INCHES FOR FLOOR MOUNTED WATER CLOSETS- | | SEC. 405.3.1 FBC P. THE FLOOR PLAN DOES NOT PROVIDE THE | | WIDTH MEASUREMENTS AND THE DEPTHS ARE UNDERSIZED AT | | 4FT. 6-INCHES. | | | | 13) A2.1.1: PLEASE SHOW THE DEPTHS OF THE MEN'S AND | | WOMEN'S SHOWERS- SEC. 608.2.2 FBC ACC. | | | | 14) A2.1.1 & A2.4.1: PLEASE SHOW THE CENTERLINE | | MEASUREMENTS OF THE ACCESSIBLE WATER CLOSETS FROM THE | | ADJACENT SIDE WALLS- SEC. 604.2 FBC P. | | | | 15) A2.1.1, A2.4.1: PLEASE SHOW THE HEIGHTS OF THE | | ACCESSIBLE WATER CLOSET SEATS FROM THE FINISHED FLOORS- | | SEC. 604.4 FBC ACC. | | | | 16) A2.4.1 DETAIL 2: IT APPEARS THE SHOWER SPRAY HANDLE | | IS LOCATED ABOVE THE MAXIMUM 48-INCHES HEIGHT ALLOWABLE | | PER SEC. 608.5.2 FBC ACC. | | | | 17) A2.4.1: THE DRINKING FOUNTAINS APPEAR TO BE | | PROTRUDING INTO THE CIRCULATION PATH WHICH IS NOT IN | | COMPLIANCE WITH SEC. 307.2 FBC ACC. | | | | 18) A2.4.1: PLEASE DETAIL ACCESSIBLE DRINKING FOUNTAIN | | COMPLIANCES PER ITEMS A, B, & C- FBC ACC. | | | | A) CLEAR FLOOR SPACE APPROACH DIAGRAM AND DIMENSIONS | | FOR THE WHEELCHAIR ACCESSIBLE FOUNTAIN - SEC. 602.2. | | | | B) KNEE AND TOE CLEARANCES FOR THE WHEELCHAIR | | ACCESSIBLE FOUNTAIN- SEC. 602.2. | | | | C) SPOUT HEIGHTS FOR THE WHEELCHAIR ACCESSIBLE FOUNTAIN | | AND THE FOUNTAIN FOR STANDING PERSONS- SEC. 602.4 & | | 602.7. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. | | | | CHRISTOPHER L. COLE | | MECHANICAL/PLUMBING PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
2 |
Status |
P |
Date |
2023-03-24 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2023-03-24 |
Time |
11:19 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2023-03-24 |
Time |
11:19 |
Sent To |
|
|
Notes |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
P |
Date |
2023-02-27 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2023-02-27 |
Time |
16:33 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2023-02-27 |
Time |
16:33 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
4 |
Status |
P |
Date |
2023-05-11 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2023-05-11 |
Time |
08:42 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2023-05-11 |
Time |
08:42 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
3 |
Status |
F |
Date |
2023-04-18 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2023-04-18 |
Time |
11:41 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2023-04-18 |
Time |
11:41 |
Sent To |
|
|
Notes |
2023-04-18 11:41:56 | SIGNATURE REVIEW | | | | CORRECTIONS NEEDED | | | | 1) DRAWINGS - COV-1, S-2.2.0, S-2.3.0, S-2.4.0, | | S-2.5.0, SP-2 DO NOT SHOW AS DIGITALLY SIGNED IN ADOBE | | READER - SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED | | TO BE DIGITALLY/ELECTRONICALLY SIGNED TO BE USED IN | | ELECTRONIC PLAN REVIEW. (A CERTIFICATE-BASED DIGITAL | | SIGNATURE (OFTEN JUST CALLED A DIGITAL SIGNATURE) IS A | | SPECIFIC TYPE OF E-SIGNATURE). |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
F |
Date |
2023-03-24 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2023-03-24 |
Time |
11:19 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2023-03-24 |
Time |
11:19 |
Sent To |
|
|
Notes |
2023-03-24 11:19:33 | SIGNATURE REVIEW | | | | CORRECTIONS NEEDED - | | | | DRAWINGS - COV-1, GN-1, DM-1, DM-2, DM-3, PGD-1, PGD-2, | | PGD-3, UT-1,UT-2, UT-3, DET-1,DET-2,DET-3, HD-1, HD-2, | | HD-3, HD-4, LT-1, LT-2, LT-3 AND ALL OF THE STRUCTURAL | | DRAWINGS DO NOT SHOW AS DIGITALLY SIGNED IN ADOBE | | READER - SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED | | TO BE DIGITALLY/ELECTRONICALLY SIGNED TO BE USED IN | | ELECTRONIC PLAN REVIEW. (A CERTIFICATE-BASED DIGITAL | | SIGNATURE (OFTEN JUST CALLED A DIGITAL SIGNATURE) IS A | | SPECIFIC TYPE OF E-SIGNATURE). | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2023-02-27 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2023-02-27 |
Time |
16:56 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2023-02-27 |
Time |
16:56 |
Sent To |
|
|
Notes |
2023-02-27 16:57:29 | SIGNATURE REVIEW | | | | CORRECTIONS NEEDED - | | | | DRAWINGS - COV-1, GN-1, DM-1, DM-2, DM-3, PGD-1, PGD-2, | | PGD-3, UT-1,UT-2, UT-3, DET-1,DET-2,DET-3, HD-1, HD-2, | | HD-3, HD-4, LT-1, LT-2, LT-3 AND ALL OF THE STRUCTURAL | | DRAWINGS DO NOT SHOW AS DIGITALLY SIGNED IN ADOBE | | READER - SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED | | TO BE DIGITALLY/ELECTRONICALLY SIGNED TO BE USED IN | | ELECTRONIC PLAN REVIEW. (A CERTIFICATE-BASED DIGITAL | | SIGNATURE (OFTEN JUST CALLED A DIGITAL SIGNATURE) IS A | | SPECIFIC TYPE OF E-SIGNATURE). | 2023-02-17 11:45:55 | MECHANICAL DIGITAL SIGNATURES APPROVED ME | 2023-02-03 13:46:53 | DIG-SIGS ON PLUMBING PLANS PASSED. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
4 |
Status |
P |
Date |
2023-05-12 |
|
|
Cont ID |
|
Sent By |
kdefranc |
Date |
2023-05-12 |
Time |
16:28 |
Rev Time |
0.00 |
Received By |
kdefranc |
Date |
2023-05-12 |
Time |
16:27 |
Sent To |
|
|
Notes |
2023-05-12 16:28:01 | 5/12/23 ??? PASSED | | | | PREVIOUS REVIEW COMMENTS TO BE ADDRESSED: | | 1. PLEASE PROVIDE A CURRENT SURVEY OF THE SUBJECT | | PROPERTY. [SATISFIED] | | 2. PLEASE PROVIDE THE CONDITIONAL APPROVAL LETTER FOR | | FORMAL SITE PLAN REVIEW (FSPR) 22-09 (Z22060027). | | [SATISFIED] | | 3. PLEASE PROVIDE THE APPROVED SITE PLANS AND DETAILS | | SHEETS ASSOCIATED WITH FSPR 22-09 (Z22060027). | | [SATISFIED] | | | | ADDITIONAL REVIEW COMMENT TO BE ADDRESSED: | | 4. IT HAS BEEN IDENTIFIED THAT SOME OF THE INFORMATION | | DEMONSTRATED/INDICATED ON THE HARDSCAPE ??? TENNIS | | COURTS PLAN (DRAWING NUMBER HD-2) IS NOT CONSISTENT | | WITH THE INFORMATION DEMONSTRATED/INDICATED ON THE | | APPROVED TENNIS CENTER SITE PLAN (DRAWING NUMBER SP-2) | | PER FSPR 22-09 (Z22060027). THEREFORE, PLEASE UPLOAD | | THE TENNIS CENTER SITE PLAN (DRAWING NUMBER SP-2) AS A | | SEPARATE DRAWINGS FILE SHEET FOR THE SUBJECT PERMIT | | APPLICATION FILE. [SATISFIED] | | | | | | KEVIE DEFRANC | | SENIOR PLANNER ??? PLANNING DIVISION | | [email protected] | | 561-822-1449 | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2023-04-19 |
|
|
Cont ID |
|
Sent By |
kdefranc |
Date |
2023-04-19 |
Time |
13:23 |
Rev Time |
0.00 |
Received By |
kdefranc |
Date |
2023-04-19 |
Time |
13:21 |
Sent To |
|
|
Notes |
2023-04-19 13:21:25 | 4/19/23 ??? PASSED | | | | PREVIOUS REVIEW COMMENTS TO BE ADDRESSED: | | 1. PLEASE PROVIDE A CURRENT SURVEY OF THE SUBJECT | | PROPERTY. [SATISFIED] | | 2. PLEASE PROVIDE THE CONDITIONAL APPROVAL LETTER FOR | | FORMAL SITE PLAN REVIEW (FSPR) 22-09 (Z22060027). | | [SATISFIED] | | 3. PLEASE PROVIDE THE APPROVED SITE PLANS AND DETAILS | | SHEETS ASSOCIATED WITH FSPR 22-09 (Z22060027). | | [SATISFIED] | | | | ADDITIONAL REVIEW COMMENT TO BE ADDRESSED: | | 4. IT HAS BEEN IDENTIFIED THAT SOME OF THE INFORMATION | | DEMONSTRATED/INDICATED ON THE HARDSCAPE ??? TENNIS | | COURTS PLAN (DRAWING NUMBER HD-2) IS NOT CONSISTENT | | WITH THE INFORMATION DEMONSTRATED/INDICATED ON THE | | APPROVED TENNIS CENTER SITE PLAN (DRAWING NUMBER SP-2) | | PER FSPR 22-09 (Z22060027). THEREFORE, PLEASE UPLOAD | | THE TENNIS CENTER SITE PLAN (DRAWING NUMBER SP-2) AS A | | SEPARATE DRAWINGS FILE SHEET FOR THE SUBJECT PERMIT | | APPLICATION FILE. [SATISFIED] | | | | | | KEVIE DEFRANC | | SENIOR PLANNER ??? PLANNING DIVISION | | [email protected] | | 561-822-1449 | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2023-04-05 |
|
|
Cont ID |
|
Sent By |
kdefranc |
Date |
2023-04-05 |
Time |
15:22 |
Rev Time |
0.00 |
Received By |
kdefranc |
Date |
2023-04-05 |
Time |
15:21 |
Sent To |
|
|
Notes |
2023-04-05 15:22:09 | 4/5/23 ??? FAILED | | | | PREVIOUS REVIEW COMMENTS TO BE ADDRESSED: | | 1. PLEASE PROVIDE A CURRENT SURVEY OF THE SUBJECT | | PROPERTY. [SATISFIED] | | 2. PLEASE PROVIDE THE CONDITIONAL APPROVAL LETTER FOR | | FORMAL SITE PLAN REVIEW (FSPR) 22-09 (Z22060027). | | [SATISFIED] | | 3. PLEASE PROVIDE THE APPROVED SITE PLANS AND DETAILS | | SHEETS ASSOCIATED WITH FSPR 22-09 (Z22060027). | | [SATISFIED] | | | | ADDITIONAL REVIEW COMMENT TO BE ADDRESSED: | | 4. IT HAS BEEN IDENTIFIED THAT SOME OF THE INFORMATION | | DEMONSTRATED/INDICATED ON THE HARDSCAPE ??? TENNIS | | COURTS PLAN (DRAWING NUMBER HD-2) IS NOT CONSISTENT | | WITH THE INFORMATION DEMONSTRATED/INDICATED ON THE | | APPROVED TENNIS CENTER SITE PLAN (DRAWING NUMBER SP-2) | | PER FSPR 22-09 (Z22060027). THEREFORE, PLEASE UPLOAD | | THE TENNIS CENTER SITE PLAN (DRAWING NUMBER SP-2) AS A | | SEPARATE DRAWINGS FILE SHEET FOR THE SUBJECT PERMIT | | APPLICATION FILE. | | | | | | KEVIE DEFRANC | | SENIOR PLANNER ??? PLANNING DIVISION | | [email protected] | | 561-822-1449 | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2023-02-06 |
|
|
Cont ID |
|
Sent By |
KDefranc |
Date |
2023-02-06 |
Time |
12:03 |
Rev Time |
0.00 |
Received By |
kdefranc |
Date |
2023-02-06 |
Time |
12:02 |
Sent To |
|
|
Notes |
2023-02-06 12:03:00 | 2/6/23 ??? FAILED | | | | REVIEW COMMENTS TO BE ADDRESSED: | | 1. PLEASE PROVIDE A CURRENT SURVEY OF THE SUBJECT | | PROPERTY. | | 2. PLEASE PROVIDE THE CONDITIONAL APPROVAL LETTER FOR | | FORMAL SITE PLAN REVIEW (FSPR) 22-09 (Z22060027). | | 3. PLEASE PROVIDE THE APPROVED SITE PLANS AND DETAILS | | SHEETS ASSOCIATED WITH FSPR 22-09 (Z22060027). | | | | | | KEVIE DEFRANC | | SENIOR PLANNER ??? PLANNING DIVISION | | [email protected] | | 561-822-1449 | | |
|
|