Plan Review Details - Permit 23010434
Plan Review Stops For Permit 23010434
Review Stop AD ADDRESSING
Rev No 2 Status P Date 2023-03-22 Cont ID  
Sent By cpuell Date 2023-03-22 Time 13:35 Rev Time 0.00
Received By cpuell Date 2023-03-22 Time 13:35 Sent To  
Notes
2023-03-22 13:36:18THE BUILDING TO BE DEMOLISHED DOESN'T HAVE IT'S OWN
 ADDRESS, PRIMARY ADDRESS OF 1501 N AUSTRALIAN AVE OK
 FOR PROJECT.

Review Stop AD ADDRESSING
Rev No 1 Status F Date 2023-01-31 Cont ID  
Sent By cpuell Date 2023-01-31 Time 08:24 Rev Time 0.00
Received By cpuell Date 2023-01-31 Time 08:24 Sent To  
Notes
2023-01-31 08:36:51PLEASE CONTACT [email protected] OR CALL
 561-805-6659 TO DISCUSS ADDRESSING THE BUILDING

Review Stop AIPP ART IN PUBLIC PLACES
Rev No 1 Status P Date 2023-03-01 Cont ID  
Sent By swelter Date 2023-03-01 Time 13:31 Rev Time 0.00
Received By swelter Date 2023-03-01 Time 13:33 Sent To  
Notes
2023-03-01 13:33:23WORKING WITH PARKS AND RECREATION ON PUBLIC ART

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2023-05-11 Cont ID  
Sent By rmcphers Date 2023-05-11 Time 08:37 Rev Time 0.00
Received By rmcphers Date 2023-05-11 Time 08:37 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2023-04-18 Cont ID  
Sent By rmcphers Date 2023-04-18 Time 11:40 Rev Time 0.00
Received By rmcphers Date 2023-04-18 Time 11:38 Sent To  
Notes
2023-04-18 11:40:32TENNIS CENTER
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
  
 1) DRAWINGS - COV-1, S-2.2.0, S-2.3.0, S-2.4.0,
 S-2.5.0, SP-2 DO NOT SHOW AS DIGITALLY SIGNED IN ADOBE
 READER - SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED
 TO BE DIGITALLY/ELECTRONICALLY SIGNED TO BE USED IN
 ELECTRONIC PLAN REVIEW. (A CERTIFICATE-BASED DIGITAL
 SIGNATURE (OFTEN JUST CALLED A DIGITAL SIGNATURE) IS A
 SPECIFIC TYPE OF E-SIGNATURE).

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2023-03-24 Cont ID  
Sent By rmcphers Date 2023-03-24 Time 11:18 Rev Time 0.00
Received By rmcphers Date 2023-03-24 Time 11:18 Sent To  
Notes
2023-03-24 11:18:35TENNIS CENTER
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
  
 1) DRAWINGS - COV-1, GN-1, DM-1, DM-2, DM-3, PGD-1,
 PGD-2, PGD-3, UT-1,UT-2, UT-3, DET-1,DET-2,DET-3, HD-1,
 HD-2, HD-3, HD-4, LT-1, LT-2, LT-3 AND ALL OF THE
 STRUCTURAL DRAWINGS DO NOT SHOW AS DIGITALLY SIGNED IN
 ADOBE READER - SIGNED AND SEALED DRAWINGS IN PROJECTDOX
 NEED TO BE DIGITALLY/ELECTRONICALLY SIGNED TO BE USED
 IN ELECTRONIC PLAN REVIEW. (A CERTIFICATE-BASED DIGITAL
 SIGNATURE (OFTEN JUST CALLED A DIGITAL SIGNATURE) IS A
 SPECIFIC TYPE OF E-SIGNATURE).

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2023-02-27 Cont ID  
Sent By rmcphers Date 2023-02-27 Time 16:38 Rev Time 0.00
Received By rmcphers Date 2023-02-27 Time 16:20 Sent To  
Notes
2023-02-27 16:31:28TENNIS CENTER
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
  
 1) PLEASE PROVIDE A SOIL REPORT. FBC 1803.1
  
 2) PLEASE SHOW THE STRUCTURAL STEEL ROOF DECK
 ATTACHMENTS - TYPE AND ON CENTER SPACING - FBC 1609.5.1
  
 3) PRODUCT APPROVAL FL17682 R6 FOR THE SWING DOOR - THE
 FRONT PAGE OF THE PRODUCT APPROVAL SAYS - "PENDING
 APPROVAL" THE STATUS SHOULD SAY "APPROVED".
  
 4) SEPARATE PERMITS ARE REQUIRED FOR - EXISTING
 BUILDING DEMOLITION, BENCH SHADE STRUCTURE, PICNIC AREA
 SHADE STRUCTURE, SITE LIGHTING, TENNIS COURTS, FENCES.
  
 5) DRAWINGS - COV-1, GN-1, DM-1, DM-2, DM-3, PGD-1,
 PGD-2, PGD-3, UT-1,UT-2, UT-3, DET-1,DET-2,DET-3, HD-1,
 HD-2, HD-3, HD-4, LT-1, LT-2, LT-3 AND ALL OF THE
 STRUCTURAL DRAWINGS DO NOT SHOW AS DIGITALLY SIGNED IN
 ADOBE READER - SIGNED AND SEALED DRAWINGS IN PROJECTDOX
 NEED TO BE DIGITALLY/ELECTRONICALLY SIGNED TO BE USED
 IN ELECTRONIC PLAN REVIEW. (A CERTIFICATE-BASED DIGITAL
 SIGNATURE (OFTEN JUST CALLED A DIGITAL SIGNATURE) IS A
 SPECIFIC TYPE OF E-SIGNATURE).

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2023-05-09 Cont ID  
Sent By jleahy Date 2023-05-09 Time 11:31 Rev Time 0.00
Received By jleahy Date 2023-05-09 Time 11:17 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2023-02-21 Cont ID  
Sent By mpeterso Date 2023-02-21 Time 15:08 Rev Time 0.00
Received By mpeterso Date 2023-02-21 Time 15:08 Sent To  
Notes
***NONE***

Review Stop E-LOWVOLT ELECTRICAL LOW VOLTAGE
Rev No 1 Status P Date 2023-05-09 Cont ID  
Sent By jleahy Date 2023-05-09 Time 12:10 Rev Time 0.00
Received By jleahy Date 2023-05-09 Time 12:10 Sent To  
Notes
2023-05-09 12:11:23VOICE AND DATA AS PER PLANS JLEAHY

Review Stop ENG ENGINEERING CSD
Rev No 3 Status P Date 2023-05-19 Cont ID  
Sent By lquinone Date 2023-05-19 Time 15:21 Rev Time 0.00
Received By lquinone Date 2023-05-19 Time 15:21 Sent To  
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 2 Status P Date 2023-04-21 Cont ID  
Sent By lquinone Date 2023-04-21 Time 15:24 Rev Time 0.00
Received By lquinone Date 2023-04-21 Time 15:24 Sent To  
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 1 Status P Date 2023-01-30 Cont ID  
Sent By rrossano Date 2023-01-30 Time   Rev Time  
Received By rrossano Date 2023-01-30 Time   Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2023-01-27 Cont ID  
Sent By cwalker Date 2023-01-27 Time   Rev Time  
Received By cwalker Date 2023-01-27 Time   Sent To  
Notes
2023-01-27 14:09:42FIRE REVIEW COMMENTS:
  
 LIFE SAFETY SYSTEM WORK (FIRE SPRINKLER AND/OR FIRE
 ALARM) SHALL BE PERFORMED UNDER SEPARATE PERMITS AND
 SHOP DRAWINGS BY PROPERLY QUALIFIED CONTRACTORS.
  
 C. WALKER
  
 561-804-4762
  
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2023-05-22 Cont ID  
Sent By aoliver Date 2023-05-22 Time 12:05 Rev Time 0.00
Received By aoliver Date 2023-05-10 Time 17:48 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2023-05-09 Cont ID  
Sent By jleahy Date 2023-05-09 Time 12:11 Rev Time 0.00
Received By jleahy Date 2023-04-14 Time 08:29 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2023-04-10 Cont ID  
Sent By aoliver Date 2023-04-10 Time 07:40 Rev Time 0.00
Received By aoliver Date 2023-03-20 Time 07:57 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2023-03-02 Cont ID  
Sent By lmarchan Date 2023-03-02 Time 08:12 Rev Time 0.00
Received By lmarchan Date 2023-01-25 Time 11:10 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2023-06-02 Cont ID  
Sent By aoliver Date 2023-06-02 Time 16:44 Rev Time 0.00
Received By aoliver Date 2023-05-22 Time 12:10 Sent To  
Notes
2023-05-22 12:11:22EMAILED IMPACT FOR REVIEW-AO

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2023-02-27 Cont ID  
Sent By rmcphers Date 2023-02-27 Time 16:33 Rev Time 0.00
Received By rmcphers Date 2023-02-27 Time 16:33 Sent To  
Notes
2023-02-27 16:37:54PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF
  
 UPON APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE
 RECEIPT TO YOUR PROJECT OR EMAIL IT TO
 [email protected] .
  

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2023-05-11 Cont ID  
Sent By medwards Date 2023-05-11 Time 13:06 Rev Time 0.00
Received By medwards Date 2023-05-11 Time 13:06 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status F Date 2023-05-02 Cont ID  
Sent By medwards Date 2023-05-02 Time 16:52 Rev Time 0.00
Received By medwards Date 2023-05-02 Time 16:52 Sent To  
Notes
2023-05-02 16:54:32THE ADJUSTED VENTILATION CALCULATIONS WERE NOT IN TIS
 SUBMITTAL. PLEASE SUBMIT THESE IN THE NEXT REVIEW
 CYCLE. FMC TABLE 403.3.1.1
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2023-04-07 Cont ID  
Sent By medwards Date 2023-04-07 Time 13:46 Rev Time 0.00
Received By medwards Date 2023-04-07 Time 13:46 Sent To  
Notes
2023-04-07 13:46:451ST REVIEW FMC
 PERMIT: 23010434
  
 CODES IN EFFECT: 2020
  
 FBC- FLORIDA BUILDING CODE
 FMC- FLORIDA MECHANICAL CODE
 FEC- FLORIDA ENERGY CONSERVATION
 FGC- FLORIDA FUEL GAS
 FEX- FLORIDA EXISTING BUILDING CODE
 FRC- FLORIDA RESIDENTIAL BUILDING CODE
 F.S.- FLORIDA STATUTES
 FAC- FLORIDA ACCESSIBILITY CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) THE BATHROOM EXHAUST SHALL MEET FMC TABLE 403.3.1.1
 WHICH IS 50 CFM PER WATER CLOSET OR URINAL IF THE FAN
 RUNS CONTINUOUSLY WHILE OCCUPIED OR 70 CFM PER WATER
 CLOSET OR URINAL IF THE FAN RUNS INTERMITTENTLY. PLEASE
 SPECIFY THE DESIGN OF THE EXHAUST FAN FOR THE
 BATHROOMS. ALSO, THE CFM???S REQUIRED IF THE FAN RUNS
 CONTINUOUSLY IS 750 CFM. EF-2 IS 700 CFM PLEASE MAKE
 SURE THE EF-2 MEETS THE MINIMUM EXHAUST REQUIREMENTS
 FOR THE BATHROOM EXHAUST.
  
 2) THIS COMMENT WAS NOT ADDRESSED IN THE FIRST CYCLE
 RESUBMITTAL: PROVIDE DETAILS FOR THE WARMING KITCHEN,
 INCLUDE ALL COOKING AND WARMING APPLIANCES. FBC 107.3.5
  
 3) THE OUTDOOR AIR CALCULATION SHOULD BE ADJUSTED FOR
 THE CORRECTED OCCUPANT COUNT TAKEN FROM FMC TABLE
 403.3.1.1 AND NOT THE ARCHITECT???S OCCUPANT COUNT. FMC
 403.3.1.1 3RD SENTENCE.
  
 CLASSROOM SHOULD BE 8 OCCUPANTS
 MULTIPURPOSE ASSEMBLY SHOULD BE 66 OCCUPANTS
  
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2023-02-17 Cont ID  
Sent By medwards Date 2023-02-17 Time 11:44 Rev Time 0.00
Received By medwards Date 2023-02-17 Time 11:44 Sent To  
Notes
2023-02-17 11:45:081ST REVIEW FMC
 PERMIT: 23010434
  
 CODES IN EFFECT: 2020
  
 FBC- FLORIDA BUILDING CODE
 FMC- FLORIDA MECHANICAL CODE
 FEC- FLORIDA ENERGY CONSERVATION
 FGC- FLORIDA FUEL GAS
 FEX- FLORIDA EXISTING BUILDING CODE
 FRC- FLORIDA RESIDENTIAL BUILDING CODE
 F.S.- FLORIDA STATUTES
 FAC- FLORIDA ACCESSIBILITY CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
 A COMPLETE REVIEW COULD NOT BE COMPLETED AS THERE WERE
 DOCUMENTS MISSING FROM THIS SUBMITTAL.
  
 1 PROVIDE THE ENERGY CALCULATIONS. FEC C402
  
 2) PROVIDE THE MECHANICAL EQUIPMENT SIZING
 CALCULATIONS. FEC C403.2.1
  
 3) PROVIDE THE OUTDOOR AIR CALCULATIONS FOR EACH USE OF
 SPACE IN THIS BUILDING. FMC 403.3.1.1 AND TABLE
 403.3.1.1
  
 4) PROVIDE DETAILS FOR THE WARMING KITCHEN, INCLUDING
 ALL COOKING AND WARMING APPLIANCES. FBC 107.3.5
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop P PLUMBING
Rev No 3 Status P Date 2023-04-24 Cont ID  
Sent By ccole Date 2023-04-24 Time 12:06 Rev Time 0.00
Received By ccole Date 2023-04-24 Time 11:19 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2023-04-06 Cont ID  
Sent By ccole Date 2023-04-06 Time 15:29 Rev Time 0.00
Received By ccole Date 2023-04-06 Time 07:12 Sent To  
Notes
2023-04-06 15:29:412ND REVIEW FBC-2020 PLUMBING
 PERMIT- 23010434
 4/6/2023
 CODES IN EFFECT:
  
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED. FAILED COMMENTS FROM THE
 1ST REVIEW ARE LISTED BELOW WITH SOME ADDITIONAL NOTES.
  
 1) 2ND REQUEST. PLEASE NOTE A SEPARATE PERMIT IS
 REQUIRED FOR THE POTABLE WATER SERVICE BACKFLOW
 PREVENTER AND THE PERMIT APPLICATION FOR THE DEVICE
 SHALL BE SUBMITTED PRIOR TO PLUMBING PLAN APPROVAL FOR
 THE BUILDING. YOU CAN SUBMIT AN APPLICATION TBD (TO BE
 DETERMINED) IF YOU DO NOT HAVE A CONTRACTOR SELECTED BY
 EMAILING A COMPLETED PERMIT APPLICATION TO
 [email protected]. YOU WILL RECEIVE INSTRUCTIONS
 TO PAY FEES AND UPLOAD PLANS. YOU MAY UPLOAD PLANS AND
 PAY FEES AT A FUTURE DATE, BUT THE APPLICATION IS
 REQUIRED AT THIS TIME. WE RECOMMEND THAT YOU PAY FEES
 AND UPLOAD PLANS AT THE SAME TIME. AFTER YOU HAVE THE
 PERMIT GENERATED, NOTIFY ME VIA EMAIL AND I WILL CHANGE
 THE REVIEW STATUS TO PASS.
  
  
 8) 2ND REQUEST. P2.1.0 & P.2.2: INDICATE THE MEANS OF
 PROVIDING TEMPERED WATER DELIVERY FROM THE PUBLIC
 LAVATORIES- SEC. 419.5 FBC P. PLEASE NOTE TEMPERED
 WATER MIXING VALVES SHALL CONFORM TO ASSE 1070- SEC.
 607.1.2 FBC P.
  
 THE ARCHITECT???S RESPONSE TO THE COMMENT INDICATES THE
 MASTER THERMOSTATIC MIXING VALVE IS SUPPLYING THE
 TEMPERED WATER. AS PREVIOUSLY NOTED TEMPERED WATER
 MIXING VALVES SHALL CONFORM TO ASSE 1070- SEC. 607.1.2
 FBC P. THE MANUFACTURER???S SPECIFICATIONS FOR THE
 SELECTED MASTER THERMOSTATIC MIXING VALVE INDICATE
 CONFORMANCE TO ASSE 1017. PLEASE PROVIDE POINT OF USE
 MIXING VALVES AT THE LAVATORIES.
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2023-02-03 Cont ID  
Sent By ccole Date 2023-02-03 Time 13:35 Rev Time 0.00
Received By ccole Date 2023-02-02 Time 16:41 Sent To  
Notes
2023-02-03 13:37:361ST REVIEW FBC-2020 PLUMBING
 PERMIT- 23010434
 CODES IN EFFECT:
  
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) PLEASE NOTE A SEPARATE PERMIT IS REQUIRED FOR THE
 POTABLE WATER SERVICE BACKFLOW PREVENTER AND THE PERMIT
 APPLICATION FOR THE DEVICE SHALL BE SUBMITTED PRIOR TO
 PLUMBING PLAN APPROVAL FOR THE BUILDING. YOU CAN SUBMIT
 AN APPLICATION TBD (TO BE DETERMINED) IF YOU DO NOT
 HAVE A CONTRACTOR SELECTED BY EMAILING A COMPLETED
 PERMIT APPLICATION TO [email protected]. YOU WILL
 RECEIVE INSTRUCTIONS TO PAY FEES AND UPLOAD PLANS. YOU
 MAY UPLOAD PLANS AND PAY FEES AT A FUTURE DATE, BUT THE
 APPLICATION IS REQUIRED AT THIS TIME. WE RECOMMEND THAT
 YOU PAY FEES AND UPLOAD PLANS AT THE SAME TIME. AFTER
 YOU HAVE THE PERMIT GENERATED, NOTIFY ME VIA EMAIL AND
 I WILL CHANGE THE REVIEW STATUS TO PASS.
  
 2) PLEASE NOTE SEPARATE PERMITS ARE REQUIRED FOR BOTH
 THE IRRIGATION SYSTEM AND THE SYSTEM BACKFLOW
 PREVENTER, HOWEVER THESE PERMITS MAY BE SUBMITTED AT A
 LATER DATE AND WILL NOT IMPACT ISSUANCE OF THE MAIN
 BUILDING PERMIT- SECS. 105.1 & 107.2.1 WPB.
  
 3) SHEETS P2.1.0 & P.2.2.0: PLEASE CORRECT THE SANITARY
 VENTING PER ITEMS A & B- FBC P.
  
 A) THE EWC1 FIXTURE DRAIN CANNOT BE VENTED BY THE L1
 COMMON DRY VENT FOR THE BATHROOM HORIZONTAL WET VENT
 SYSTEM- SECS. 912.1 & 912.2.1. AN INDIVIDUAL VENT IS
 REQUIRED FOR THE EWC1 AND THE FIXTURE DRAIN SHALL
 CONNECT TO THE BUILDING DRAIN DOWNSTREAM OF THE
 BATHROOM HORIZONTAL WET VENT CONNECTION.
  
 B) THE FIXTURE DRAIN FOR SH1 IN WOMEN'S SHOWER IS NOT
 BEING VENTED BY THE BATHROOM WET VENT BRANCH UPSTREAM
 OF IT AND IS MAKING AN INDIVIDUAL CONNECTION TO THE
 BUILDING DRAIN. EITHER RELOCATE THE DRAIN CONNECTION TO
 THE BRANCH DRAIN OR PROVIDE AN INDIVIDUAL VENT- SECS.
 910.1 & 912.1.
  
 4) P2.1.0 & P.2.2.0: PROVIDE TRAP SEAL PROTECTION FOR
 THE FLOOR DRAINS- SEC. 1002.4.1.1 FBC P.
  
 5) P2.1.0 & P.2.2.0: SHOW THE LOCATION OF THE REQUIRED
 EWH THERMAL EXPANSION CONTROL DEVICE AND PIPING
 CONNECTION- SEC. 607.3 FBC P.
  
 6) P2.1.0 & P2.2.0: DETAIL EWH RELIEF VALVE DISCHARGE
 SYSTEM- DISCHARGE PIPE, PAN, PAN DRAIN PIPE, AND DRAIN
 TERMINATION LOCATION- SECS. 504.4- 504.7.2 FBC P.
  
 7) P2.0.0: PLEASE PROVIDE AN EQUIPMENT SCHEDULE FOR THE
 MASTER THERMOSTATIC MIXING VALVE- SEC. 607.1.1 & 613.1
 FBC P.
  
 8) P2.1.0 & P.2.2: INDICATE THE MEANS OF PROVIDING
 TEMPERED WATER DELIVERY FROM THE PUBLIC LAVATORIES-
 SEC. 419.5 FBC P. PLEASE NOTE TEMPERED WATER MIXING
 VALVES SHALL CONFORM TO ASSE 1070- SEC. 607.1.2 FBC P.
  
 9) P2.1.0 & P.2.2: THE 1/2-INCH FIXTURE SUPPLY PIPES TO
 THE LAVATORIES ARE EXCEEDING THEIR MAXIMUM ALLOWABLE
 LENGTHS BASED ON TABLE C404.5.1 FBC ENERGY. PROVIDE
 EITHER A RECIRCULATION PUMP FOR THE SYSTEM WITH
 RECIRCULATION LOOPS TO THE LAVS, OR POINT OF USE WATER
 HEATERS AT EACH LAV LOCATION.
  
 10) SHEETS A-2.1.3, P2.1.0 P.2.2.0: PLEASE PROVIDE ROOF
 DRAINAGE GPM FLOW CALCULATIONS BASED ON THE RATE FALL
 RATE AND ROOF SQUARE FOOT AREAS- SECS. 1106.1 & 1106.2
 FBC P.
  
 11) P2.1.0: THE PLAN SHOWS A WARMING KITCHEN WITH A
 SINK. PLEASE DETAIL WHAT TYPE OF FOOD PREP OR COOKING
 OPERATIONS WILL BE CONDUCTED IN THE KITCHEN IN ORDER TO
 DETERMINE IF GREASE WASTE REMOVAL WILL BE REQUIRED-
 REFER TO SECS. 1003.3.1 FBC P.
  
 12) A2.1.1 & P2.0.0: THE WIDTHS OF THE STANDARD WATER
 CLOSET COMPARTMENTS SHALL BE 30-INCHES, AND THE DEPTHS
 SHALL BE 60-INCHES FOR FLOOR MOUNTED WATER CLOSETS-
 SEC. 405.3.1 FBC P. THE FLOOR PLAN DOES NOT PROVIDE THE
 WIDTH MEASUREMENTS AND THE DEPTHS ARE UNDERSIZED AT
 4FT. 6-INCHES.
  
 13) A2.1.1: PLEASE SHOW THE DEPTHS OF THE MEN'S AND
 WOMEN'S SHOWERS- SEC. 608.2.2 FBC ACC.
  
 14) A2.1.1 & A2.4.1: PLEASE SHOW THE CENTERLINE
 MEASUREMENTS OF THE ACCESSIBLE WATER CLOSETS FROM THE
 ADJACENT SIDE WALLS- SEC. 604.2 FBC P.
  
 15) A2.1.1, A2.4.1: PLEASE SHOW THE HEIGHTS OF THE
 ACCESSIBLE WATER CLOSET SEATS FROM THE FINISHED FLOORS-
 SEC. 604.4 FBC ACC.
  
 16) A2.4.1 DETAIL 2: IT APPEARS THE SHOWER SPRAY HANDLE
 IS LOCATED ABOVE THE MAXIMUM 48-INCHES HEIGHT ALLOWABLE
 PER SEC. 608.5.2 FBC ACC.
  
 17) A2.4.1: THE DRINKING FOUNTAINS APPEAR TO BE
 PROTRUDING INTO THE CIRCULATION PATH WHICH IS NOT IN
 COMPLIANCE WITH SEC. 307.2 FBC ACC.
  
 18) A2.4.1: PLEASE DETAIL ACCESSIBLE DRINKING FOUNTAIN
 COMPLIANCES PER ITEMS A, B, & C- FBC ACC.
  
 A) CLEAR FLOOR SPACE APPROACH DIAGRAM AND DIMENSIONS
 FOR THE WHEELCHAIR ACCESSIBLE FOUNTAIN - SEC. 602.2.
  
 B) KNEE AND TOE CLEARANCES FOR THE WHEELCHAIR
 ACCESSIBLE FOUNTAIN- SEC. 602.2.
  
 C) SPOUT HEIGHTS FOR THE WHEELCHAIR ACCESSIBLE FOUNTAIN
 AND THE FOUNTAIN FOR STANDING PERSONS- SEC. 602.4 &
 602.7.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2023-03-24 Cont ID  
Sent By rmcphers Date 2023-03-24 Time 11:19 Rev Time 0.00
Received By rmcphers Date 2023-03-24 Time 11:19 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2023-02-27 Cont ID  
Sent By rmcphers Date 2023-02-27 Time 16:33 Rev Time 0.00
Received By rmcphers Date 2023-02-27 Time 16:33 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 4 Status P Date 2023-05-11 Cont ID  
Sent By rmcphers Date 2023-05-11 Time 08:42 Rev Time 0.00
Received By rmcphers Date 2023-05-11 Time 08:42 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status F Date 2023-04-18 Cont ID  
Sent By rmcphers Date 2023-04-18 Time 11:41 Rev Time 0.00
Received By rmcphers Date 2023-04-18 Time 11:41 Sent To  
Notes
2023-04-18 11:41:56SIGNATURE REVIEW
  
 CORRECTIONS NEEDED
  
 1) DRAWINGS - COV-1, S-2.2.0, S-2.3.0, S-2.4.0,
 S-2.5.0, SP-2 DO NOT SHOW AS DIGITALLY SIGNED IN ADOBE
 READER - SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED
 TO BE DIGITALLY/ELECTRONICALLY SIGNED TO BE USED IN
 ELECTRONIC PLAN REVIEW. (A CERTIFICATE-BASED DIGITAL
 SIGNATURE (OFTEN JUST CALLED A DIGITAL SIGNATURE) IS A
 SPECIFIC TYPE OF E-SIGNATURE).

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2023-03-24 Cont ID  
Sent By rmcphers Date 2023-03-24 Time 11:19 Rev Time 0.00
Received By rmcphers Date 2023-03-24 Time 11:19 Sent To  
Notes
2023-03-24 11:19:33SIGNATURE REVIEW
  
 CORRECTIONS NEEDED -
  
 DRAWINGS - COV-1, GN-1, DM-1, DM-2, DM-3, PGD-1, PGD-2,
 PGD-3, UT-1,UT-2, UT-3, DET-1,DET-2,DET-3, HD-1, HD-2,
 HD-3, HD-4, LT-1, LT-2, LT-3 AND ALL OF THE STRUCTURAL
 DRAWINGS DO NOT SHOW AS DIGITALLY SIGNED IN ADOBE
 READER - SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED
 TO BE DIGITALLY/ELECTRONICALLY SIGNED TO BE USED IN
 ELECTRONIC PLAN REVIEW. (A CERTIFICATE-BASED DIGITAL
 SIGNATURE (OFTEN JUST CALLED A DIGITAL SIGNATURE) IS A
 SPECIFIC TYPE OF E-SIGNATURE).
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2023-02-27 Cont ID  
Sent By rmcphers Date 2023-02-27 Time 16:56 Rev Time 0.00
Received By rmcphers Date 2023-02-27 Time 16:56 Sent To  
Notes
2023-02-27 16:57:29SIGNATURE REVIEW
  
 CORRECTIONS NEEDED -
  
 DRAWINGS - COV-1, GN-1, DM-1, DM-2, DM-3, PGD-1, PGD-2,
 PGD-3, UT-1,UT-2, UT-3, DET-1,DET-2,DET-3, HD-1, HD-2,
 HD-3, HD-4, LT-1, LT-2, LT-3 AND ALL OF THE STRUCTURAL
 DRAWINGS DO NOT SHOW AS DIGITALLY SIGNED IN ADOBE
 READER - SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED
 TO BE DIGITALLY/ELECTRONICALLY SIGNED TO BE USED IN
 ELECTRONIC PLAN REVIEW. (A CERTIFICATE-BASED DIGITAL
 SIGNATURE (OFTEN JUST CALLED A DIGITAL SIGNATURE) IS A
 SPECIFIC TYPE OF E-SIGNATURE).
2023-02-17 11:45:55MECHANICAL DIGITAL SIGNATURES APPROVED ME
2023-02-03 13:46:53DIG-SIGS ON PLUMBING PLANS PASSED.

Review Stop Z ZONING
Rev No 4 Status P Date 2023-05-12 Cont ID  
Sent By kdefranc Date 2023-05-12 Time 16:28 Rev Time 0.00
Received By kdefranc Date 2023-05-12 Time 16:27 Sent To  
Notes
2023-05-12 16:28:015/12/23 ??? PASSED
  
 PREVIOUS REVIEW COMMENTS TO BE ADDRESSED:
 1. PLEASE PROVIDE A CURRENT SURVEY OF THE SUBJECT
 PROPERTY. [SATISFIED]
 2. PLEASE PROVIDE THE CONDITIONAL APPROVAL LETTER FOR
 FORMAL SITE PLAN REVIEW (FSPR) 22-09 (Z22060027).
 [SATISFIED]
 3. PLEASE PROVIDE THE APPROVED SITE PLANS AND DETAILS
 SHEETS ASSOCIATED WITH FSPR 22-09 (Z22060027).
 [SATISFIED]
  
 ADDITIONAL REVIEW COMMENT TO BE ADDRESSED:
 4. IT HAS BEEN IDENTIFIED THAT SOME OF THE INFORMATION
 DEMONSTRATED/INDICATED ON THE HARDSCAPE ??? TENNIS
 COURTS PLAN (DRAWING NUMBER HD-2) IS NOT CONSISTENT
 WITH THE INFORMATION DEMONSTRATED/INDICATED ON THE
 APPROVED TENNIS CENTER SITE PLAN (DRAWING NUMBER SP-2)
 PER FSPR 22-09 (Z22060027). THEREFORE, PLEASE UPLOAD
 THE TENNIS CENTER SITE PLAN (DRAWING NUMBER SP-2) AS A
 SEPARATE DRAWINGS FILE SHEET FOR THE SUBJECT PERMIT
 APPLICATION FILE. [SATISFIED]
  
  
 KEVIE DEFRANC
 SENIOR PLANNER ??? PLANNING DIVISION
 [email protected]
 561-822-1449
  

Review Stop Z ZONING
Rev No 3 Status P Date 2023-04-19 Cont ID  
Sent By kdefranc Date 2023-04-19 Time 13:23 Rev Time 0.00
Received By kdefranc Date 2023-04-19 Time 13:21 Sent To  
Notes
2023-04-19 13:21:254/19/23 ??? PASSED
  
 PREVIOUS REVIEW COMMENTS TO BE ADDRESSED:
 1. PLEASE PROVIDE A CURRENT SURVEY OF THE SUBJECT
 PROPERTY. [SATISFIED]
 2. PLEASE PROVIDE THE CONDITIONAL APPROVAL LETTER FOR
 FORMAL SITE PLAN REVIEW (FSPR) 22-09 (Z22060027).
 [SATISFIED]
 3. PLEASE PROVIDE THE APPROVED SITE PLANS AND DETAILS
 SHEETS ASSOCIATED WITH FSPR 22-09 (Z22060027).
 [SATISFIED]
  
 ADDITIONAL REVIEW COMMENT TO BE ADDRESSED:
 4. IT HAS BEEN IDENTIFIED THAT SOME OF THE INFORMATION
 DEMONSTRATED/INDICATED ON THE HARDSCAPE ??? TENNIS
 COURTS PLAN (DRAWING NUMBER HD-2) IS NOT CONSISTENT
 WITH THE INFORMATION DEMONSTRATED/INDICATED ON THE
 APPROVED TENNIS CENTER SITE PLAN (DRAWING NUMBER SP-2)
 PER FSPR 22-09 (Z22060027). THEREFORE, PLEASE UPLOAD
 THE TENNIS CENTER SITE PLAN (DRAWING NUMBER SP-2) AS A
 SEPARATE DRAWINGS FILE SHEET FOR THE SUBJECT PERMIT
 APPLICATION FILE. [SATISFIED]
  
  
 KEVIE DEFRANC
 SENIOR PLANNER ??? PLANNING DIVISION
 [email protected]
 561-822-1449
  

Review Stop Z ZONING
Rev No 2 Status F Date 2023-04-05 Cont ID  
Sent By kdefranc Date 2023-04-05 Time 15:22 Rev Time 0.00
Received By kdefranc Date 2023-04-05 Time 15:21 Sent To  
Notes
2023-04-05 15:22:094/5/23 ??? FAILED
  
 PREVIOUS REVIEW COMMENTS TO BE ADDRESSED:
 1. PLEASE PROVIDE A CURRENT SURVEY OF THE SUBJECT
 PROPERTY. [SATISFIED]
 2. PLEASE PROVIDE THE CONDITIONAL APPROVAL LETTER FOR
 FORMAL SITE PLAN REVIEW (FSPR) 22-09 (Z22060027).
 [SATISFIED]
 3. PLEASE PROVIDE THE APPROVED SITE PLANS AND DETAILS
 SHEETS ASSOCIATED WITH FSPR 22-09 (Z22060027).
 [SATISFIED]
  
 ADDITIONAL REVIEW COMMENT TO BE ADDRESSED:
 4. IT HAS BEEN IDENTIFIED THAT SOME OF THE INFORMATION
 DEMONSTRATED/INDICATED ON THE HARDSCAPE ??? TENNIS
 COURTS PLAN (DRAWING NUMBER HD-2) IS NOT CONSISTENT
 WITH THE INFORMATION DEMONSTRATED/INDICATED ON THE
 APPROVED TENNIS CENTER SITE PLAN (DRAWING NUMBER SP-2)
 PER FSPR 22-09 (Z22060027). THEREFORE, PLEASE UPLOAD
 THE TENNIS CENTER SITE PLAN (DRAWING NUMBER SP-2) AS A
 SEPARATE DRAWINGS FILE SHEET FOR THE SUBJECT PERMIT
 APPLICATION FILE.
  
  
 KEVIE DEFRANC
 SENIOR PLANNER ??? PLANNING DIVISION
 [email protected]
 561-822-1449
  

Review Stop Z ZONING
Rev No 1 Status F Date 2023-02-06 Cont ID  
Sent By KDefranc Date 2023-02-06 Time 12:03 Rev Time 0.00
Received By kdefranc Date 2023-02-06 Time 12:02 Sent To  
Notes
2023-02-06 12:03:002/6/23 ??? FAILED
  
 REVIEW COMMENTS TO BE ADDRESSED:
 1. PLEASE PROVIDE A CURRENT SURVEY OF THE SUBJECT
 PROPERTY.
 2. PLEASE PROVIDE THE CONDITIONAL APPROVAL LETTER FOR
 FORMAL SITE PLAN REVIEW (FSPR) 22-09 (Z22060027).
 3. PLEASE PROVIDE THE APPROVED SITE PLANS AND DETAILS
 SHEETS ASSOCIATED WITH FSPR 22-09 (Z22060027).
  
  
 KEVIE DEFRANC
 SENIOR PLANNER ??? PLANNING DIVISION
 [email protected]
 561-822-1449
  