Plan Review Stops For Permit 23010047 |
Review Stop |
AD |
ADDRESSING |
Rev No |
2 |
Status |
P |
Date |
2023-02-01 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2023-02-01 |
Time |
14:39 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2023-02-01 |
Time |
14:39 |
Sent To |
|
|
Notes |
2023-02-01 14:39:38 | SOUTH UNIT ONLY WITH THE ADDRESS OF 4300 SPRUCE AVE |
|
|
Review Stop |
AD |
ADDRESSING |
Rev No |
1 |
Status |
F |
Date |
2023-01-04 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2023-01-04 |
Time |
15:50 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2023-01-04 |
Time |
15:48 |
Sent To |
|
|
Notes |
2023-01-04 15:50:00 | IS THIS FOR THE NORTH UNIT (4302 SPRUCE AVE ) OR THE | | SOUTH UNIT (4300 SPRUCE AVE), PLEASE RESPOND TO | | [email protected] OR CALL 561-805-6659 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
P |
Date |
2023-03-23 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2023-03-23 |
Time |
13:02 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2023-03-23 |
Time |
08:08 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
F |
Date |
2023-03-15 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2023-03-15 |
Time |
13:53 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2023-03-15 |
Time |
13:41 |
Sent To |
|
|
Notes |
2023-03-15 13:53:29 | JONATHAN BROOKS JR. | | BUILDING PLANS EXAMINER | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | PHONE (561) 805-6656 | | EMAIL: [email protected] | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | FBC B = FBC BUILDING | | FBC R = FBC RESIDENTIAL | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX. | | | | 1. PLEASE ADDRESS THE SIGNATURE REVIEW COMMENTS. | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2023-03-01 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2023-03-01 |
Time |
12:01 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2023-03-01 |
Time |
08:07 |
Sent To |
|
|
Notes |
2023-03-01 12:01:30 | JONATHAN BROOKS JR. | | BUILDING PLANS EXAMINER | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | PHONE (561) 805-6656 | | EMAIL: [email protected] | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | FBC B = FBC BUILDING | | FBC R = FBC RESIDENTIAL | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX. | | | | 1. FBC R 301 FAC9N-3 SUBMITTED FLORIDA DBPR PRODUCT | | APPROVAL FL16709-R10 SELECTED OPTION FOR SYSTEM NO W-5; | | EXPOSURE (D); ENCLOSURE (OPEN); ROOF HEIGHT (H<15); | | ULTIMATE WIND SPEED (170) IS NOT CORRECT. THE CORRECT | | ENCLOSURE FOR THE LISTED ADDRESS IS ENCLOSED; THIS IS | | AN ENCLOSED STRUCTURE. PRODUCT APPROVAL FL16709-R10 | | WILL NOT SATISFY EXPOSURE CATEGORY D ENCLOSED AREAS | | WITHOUT USING INSULATION OR PROVIDING ENGINEERED. | | SECOND REQUEST. | | | | ENHANCED NAILING. PLEASE NOTE THAT SUBMITTAL OF | | ADDITIONAL AND/OR REVISED MATERIALS MAY RESULT IN NEW | | PLAN REVIEW COMMENTS. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2023-02-14 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2023-02-14 |
Time |
12:50 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2023-02-14 |
Time |
08:06 |
Sent To |
|
|
Notes |
2023-02-14 12:51:04 | JONATHAN BROOKS JR. | | BUILDING PLANS EXAMINER | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | PHONE (561) 805-6656 | | EMAIL: [email protected] | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | FBC B = FBC BUILDING | | FBC R = FBC RESIDENTIAL | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX. | | | | 1. FBC R 301 FAC9N-3 SUBMITTED FLORIDA DBPR PRODUCT | | APPROVAL FL16709-R10 SELECTED OPTION FOR SYSTEM NO W-5; | | EXPOSURE (C); ENCLOSURE (ENCLOSED); ROOF HEIGHT (H<15); | | ULTIMATE WIND SPEED (170) IS NOT CORRECT. THE CORRECT | | EXPOSURE FOR THE LISTED ADDRESS IS EXPOSURE D. PRODUCT | | APPROVAL FL16709-R10 WILL NOT SATISFY EXPOSURE CATEGORY | | D ENCLOSED AREAS WITHOUT USING INSULATION OR PROVIDING | | ENGINEERED | | 2. FBC B 107.2.1 FBC EB 706.1 SUBMITTED ROOF | | DRAWING/SKETCH LISTS FLAT/LOW ROOF SLOPE AS 0:12; LOW | | SLOPE ROOFS MUST SHOW POSITIVE DRAINAGE. PROVIDE METHOD | | OF PROVIDING POSITIVE DRAINAGE. | | | | ENHANCED NAILING. PLEASE NOTE THAT SUBMITTAL OF | | ADDITIONAL AND/OR REVISED MATERIALS MAY RESULT IN NEW | | PLAN REVIEW COMMENTS. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2023-01-31 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2023-01-31 |
Time |
12:35 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2023-01-31 |
Time |
08:08 |
Sent To |
|
|
Notes |
2023-01-31 12:36:20 | JONATHAN BROOKS JR. | | BUILDING PLANS EXAMINER | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | PHONE (561) 805-6656 | | EMAIL: [email protected] | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | FBC B = FBC BUILDING | | FBC R = FBC RESIDENTIAL | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX. | | | | 1. FBC B 107.2.1 THE CITY OF WEST PALM BEACH IS NOT | | LOCATED IN A HVHZ AND HAS NOT ADOPTED RAS 150. PROVIDE | | A COMPLETE SET OF 2020 CODE VERSION PRODUCT | | APPROVALS/NOA'S FOR THE PROPOSED FLAT ROOF SYSTEM TO BE | | USED. INCLUDE COVER PAGE, EVALUATION REPORTS AND | | INSTALLATION INSTRUCTIONS FOR SYSTEM USED. ALL | | APPLICABLE DETAILS AND ATTACHMENTS MUST BE CLEARLY | | IDENTIFIED ON THE PRODUCT APPROVAL DRAWINGS. DETAILS | | AND ATTACHMENTS NOT SPECIFICALLY COVERED IN PRODUCT | | APPROVALS WILL NEED SITE-SPECIFIC ENGINEERING. | | 2. FBC B 107.2.1 FOR CLARITY PLEASE REVISE ROOF | | DIAGRAM/SKETCH AND INCLUDE ROOF SLOPE(S), MEAN ROOF | | HEIGHT(S). FLAT/LOW SLOPE ROOFS MUST SHOW POSITIVE | | DRAINAGE. | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2023-03-23 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2023-03-23 |
Time |
13:03 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2023-03-16 |
Time |
15:49 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2023-03-15 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2023-03-15 |
Time |
13:53 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2023-03-09 |
Time |
15:32 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2023-03-01 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2023-03-01 |
Time |
12:01 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2023-02-15 |
Time |
16:25 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2023-02-14 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2023-02-14 |
Time |
12:51 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2023-02-02 |
Time |
12:43 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2023-01-31 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2023-01-31 |
Time |
12:36 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2023-01-25 |
Time |
16:25 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2023-03-23 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2023-03-23 |
Time |
13:03 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2023-03-23 |
Time |
08:08 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2023-03-15 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2023-03-15 |
Time |
13:54 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2023-03-15 |
Time |
13:49 |
Sent To |
|
|
Notes |
2023-03-15 13:54:33 | JONATHAN BROOKS JR. | | BUILDING PLANS EXAMINER | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | PHONE (561) 805-6656 | | EMAIL: [email protected] | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | FBC B = FBC BUILDING | | FBC R = FBC RESIDENTIAL | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | RESULTS: DENIED | | | | SUBMITTED SIGNED AND SEALED ENHANCED NAILING | | CALCULATIONS IS A COPY OF A WET SIGNATURE. PLEASE | | UPLOAD A VALID ELECTRONICALLY SIGNED PLAN/DOCUMENT TO | | PROJECTDOX | | | | FS471, DOCUMENTS PREPARED BY AN ENGINEER AND SUBMITTED | | FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED, DATED | | ORIGINALS. A SCAN OF A SIGNED PLAN IS NOT CONSIDERED AN | | ORIGINAL. | | PLEASE UPLOAD A VALID ELECTRONICALLY SIGNED | | PLAN/DOCUMENT TO PROJECTDOX | | PAPER PLANS/DOCUMENTS FOR SIGNATURE REVIEW WILL NO | | LONGER BE ACCEPTED BY THE CITY OF WEST PALM BEACH | | BUILDING DEPRTMENT. | | | | |
|
|