Plan Review Stops For Permit 22121199 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2023-04-03 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2023-04-03 |
Time |
11:15 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2023-04-03 |
Time |
08:53 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2023-03-22 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2023-03-22 |
Time |
12:31 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2023-03-22 |
Time |
08:02 |
Sent To |
|
|
Notes |
2023-03-22 12:31:46 | JONATHAN BROOKS JR. | | BUILDING PLANS EXAMINER | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | PHONE (561) 805-6656 | | EMAIL: [email protected] | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | FBC B = FBC BUILDING | | FBC R = FBC RESIDENTIAL | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX. | | | | 1. FBC EB 706.8.1 REVISE THE DETAILED COST ESTIMATE OF | | THE EVALUATION AND INSTALLATION OF CONNECTIONS TO | | INCLUDE ONLY THE COST OF IMPROVING THE GABLE ENDS OR | | ALL CORNERS THAT WILL EXCEED 15% OF THE COST OF THE | | ROOF REPLACEMENT WHEN COMPLETED. | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2023-02-28 |
|
|
Cont ID |
|
Sent By |
lbond |
Date |
2023-02-28 |
Time |
14:31 |
Rev Time |
0.00 |
Received By |
lbond |
Date |
2023-02-28 |
Time |
14:31 |
Sent To |
|
|
Notes |
2023-02-28 14:36:54 | BUILDING REVIEW COMMENTS: | | | | W.P.B. PERMIT: 22121199 | | REVIEWED: FEBRUARY 28, 2023 | | | | FLORIDA BUILDING CODE,7TH EDITION (2020) | | FBC[AMENDED] = 2017 CHAPTER 1 WPB AMENDMENTS (SEE LINK | | BELOW) | | HTTPS://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/ | | BUILDING-PERMIT-FORMS | | FBC BUILDING | | FBC EXISTING BUILDING | | FBC EB 706.8 | | | | COMMENTS: | | | | 1) PLEASE PROVIDE STRAP DETAILS. | | 2) INCLUDE ENGINEERING PLAN WITH STRAP LOCATION. | | | | IF YOU HAVE ANY QUESTIONS OR CONCERNS, PLEASE DO NOT | | HESITATE TO CONTACT ME | | | | LOUIS BOND, AIA | | BUILDING PLANS EXAMINER II | | DEVELOPMENT SERVICES DEPT. | | BUILDING DIVISION | | 401 CLEMATIS STREET | | WEST PALM BEACH, FLORIDA 33401 | | PH: 561-805-6729 | | FX: 561-805-6676 | | EMAIL: [email protected] | | | | | | NOTES: | | PLEASE PROVIDE COMMENT RESPONSE SHEET TO EXPLAIN HOW | | EACH COMMENT IS BEING ADDRESSED. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2022-12-29 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2022-12-29 |
Time |
09:12 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2022-12-29 |
Time |
07:42 |
Sent To |
|
|
Notes |
2022-12-29 09:13:13 | JONATHAN BROOKS JR. | | BUILDING PLANS EXAMINER | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | PHONE (561) 805-6656 | | EMAIL: [email protected] | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | FBC B = FBC BUILDING | | FBC R = FBC RESIDENTIAL | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX. | | | | 1. FBC B 107.2.1. REVISE SUBMITTED FASTENER DENSITY | | CALCULATIONS PREPARED, SIGNED AND SEALED BY A FLORIDA | | REGISTERED PROFESSIONAL ENGINEER; TO THE CORRECT | | PROJECT ADDRESS 308 MONROE DR. WEST PALM BEACH, FLORIDA | | 33405 | | 2. FBC B 107.2.1 FBC EB 706.1 SUBMITTED ROOF | | DRAWING/SKETCH LISTS FLAT/LOW ROOF SLOPE AS 0:12 IN | | AREAS B & C; LOW SLOPE ROOFS MUST SHOW POSITIVE | | DRAINAGE. PROVIDE METHOD OF PROVIDING POSITIVE | | DRAINAGE. | | 3. FBC EB 706.8. SHOW THAT THE VALUE OF THE STRUCTURE | | IS LESS THAN $300,000.00 OR SPECIFY HOW THE ROOF TO | | WALL CONNECTIONS WILL BE IMPROVED. | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
2 |
Status |
N |
Date |
2023-01-31 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2023-01-31 |
Time |
14:46 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2023-01-31 |
Time |
14:45 |
Sent To |
|
|
Notes |
2023-01-31 14:46:43 | *FLAT ROOF ONLY* |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
N |
Date |
2022-12-29 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2022-12-29 |
Time |
09:13 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2023-01-31 |
Time |
14:47 |
Sent To |
|
|
Notes |
2022-12-29 09:13:52 | *FLAT ROOF ONLY* |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2023-04-03 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2023-04-03 |
Time |
11:15 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2023-03-23 |
Time |
15:17 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2023-03-22 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2023-03-22 |
Time |
12:31 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2023-03-13 |
Time |
16:05 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2023-02-16 |
|
|
Cont ID |
|
Sent By |
aoliver |
Date |
2023-02-16 |
Time |
09:43 |
Rev Time |
0.00 |
Received By |
aoliver |
Date |
2023-02-15 |
Time |
11:23 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2023-01-31 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2023-01-31 |
Time |
14:47 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2023-01-18 |
Time |
11:04 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2022-12-29 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2022-12-29 |
Time |
09:14 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2022-12-28 |
Time |
08:04 |
Sent To |
|
|
Notes |
|
|
Review Stop |
PRIVATEPRV |
PRIVATE PROVIDER DOCUMENTS |
Rev No |
3 |
Status |
P |
Date |
2023-02-27 |
|
|
Cont ID |
|
Sent By |
dbattles |
Date |
2023-02-27 |
Time |
16:52 |
Rev Time |
0.00 |
Received By |
dbattles |
Date |
2023-02-27 |
Time |
16:52 |
Sent To |
|
|
Notes |
2023-02-27 16:53:25 | PRIVATE PROVIDER INSPECTIONS ONLY. |
|
|
Review Stop |
PRIVATEPRV |
PRIVATE PROVIDER DOCUMENTS |
Rev No |
2 |
Status |
F |
Date |
2023-02-16 |
|
|
Cont ID |
|
Sent By |
jbaker |
Date |
2023-02-16 |
Time |
08:55 |
Rev Time |
0.00 |
Received By |
jbaker |
Date |
2023-02-16 |
Time |
08:51 |
Sent To |
|
|
Notes |
2023-02-16 08:54:49 | SEE 1.24/23 CTHROOP COMMENTS: THESE COMMENTS HAVE NOT | | BEEN SATISFIED. | | | | AFFIDAVIT DOES NOT IDENTIFY EACH SHEET REVIEWED. THE | | AFFIDAVIT ONLY GIVES A NUMERICAL VALUE OF 4 SHEETS | | REVIEWED, BUT DOES NOT IDENTIFY THEM. |
|
|
Review Stop |
PRIVATEPRV |
PRIVATE PROVIDER DOCUMENTS |
Rev No |
1 |
Status |
F |
Date |
2023-01-24 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2023-01-24 |
Time |
16:49 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2023-01-24 |
Time |
16:31 |
Sent To |
|
|
Notes |
2023-01-24 16:55:09 | PRIVATE PROVIDER PER F.S. 553.791 | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | PLANS EXAMINER II PX3169/SFP306 | | BU1635 BN4338 | | ASFPM CFM US-21-11935 | | CITY OF WEST PALM BEACH | | (561) 805-6726 | | [email protected] | | | | CODES IN EFFECT: | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | NFPA 70 2017 EDITION NEC 2017 | | | | 1ST REVIEW | | | | RESULTS: CORRECTIONS NEEDED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1. PROVIDE A LIST OF THE PLAN SHEETS REVIEWED ON THE | | PLAN COMPLIANCE AFFIDAVIT. | | PRIVATE PROVIDER PER F.S. 553.791 | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2023-02-28 |
|
|
Cont ID |
|
Sent By |
lbond |
Date |
2023-02-28 |
Time |
14:30 |
Rev Time |
0.00 |
Received By |
lbond |
Date |
2023-02-28 |
Time |
14:30 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2022-12-29 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2022-12-29 |
Time |
08:54 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2022-12-29 |
Time |
08:49 |
Sent To |
|
|
Notes |
2022-12-29 08:54:53 | JONATHAN BROOKS JR. | | BUILDING PLANS EXAMINER | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | PHONE (561) 805-6656 | | EMAIL: [email protected] | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | FBC B = FBC BUILDING | | FBC R = FBC RESIDENTIAL | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | RESULTS: DENIED | | | | SUBMITTED SIGNED AND SEALED ENHANCED NAILING | | CALCULATIONS CAN NOT BE VERIFIED IT APPEARS TO BE A | | COPY OF A DIGITALLY SIGNED DOCUMENT. PLEASE UPLOAD A | | VALID ELECTRONICALLY SIGNED PLAN/DOCUMENT TO | | PROJECTDOX. | | | | FS471, DOCUMENTS PREPARED BY AN ENGINEER AND SUBMITTED | | FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED, DATED | | ORIGINALS. A SCAN OF A SIGNED PLAN IS NOT CONSIDERED AN | | ORIGINAL. | | PLEASE UPLOAD A VALID ELECTRONICALLY SIGNED | | PLAN/DOCUMENT TO PROJECTDOX | | PAPER PLANS/DOCUMENTS FOR SIGNATURE REVIEW WILL NO | | LONGER BE ACCEPTED BY THE CITY OF WEST PALM BEACH | | BUILDING DEPRTMENT. | | | | FEEL FREE TO CONTACT ME IF YOU WISH TO DISCUSS, | | 561-805-6656. | | |
|
|