Plan Review Details - Permit 22121199
Plan Review Stops For Permit 22121199
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2023-04-03 Cont ID  
Sent By jbrooks Date 2023-04-03 Time 11:15 Rev Time 0.00
Received By jbrooks Date 2023-04-03 Time 08:53 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2023-03-22 Cont ID  
Sent By jbrooks Date 2023-03-22 Time 12:31 Rev Time 0.00
Received By jbrooks Date 2023-03-22 Time 08:02 Sent To  
Notes
2023-03-22 12:31:46JONATHAN BROOKS JR.
 BUILDING PLANS EXAMINER
 WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM
 PHONE (561) 805-6656
 EMAIL: [email protected]
  
 1ST REVIEW: FBC 2020 7TH EDITION
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
 TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT
 CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX.
  
 1. FBC EB 706.8.1 REVISE THE DETAILED COST ESTIMATE OF
 THE EVALUATION AND INSTALLATION OF CONNECTIONS TO
 INCLUDE ONLY THE COST OF IMPROVING THE GABLE ENDS OR
 ALL CORNERS THAT WILL EXCEED 15% OF THE COST OF THE
 ROOF REPLACEMENT WHEN COMPLETED.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2023-02-28 Cont ID  
Sent By lbond Date 2023-02-28 Time 14:31 Rev Time 0.00
Received By lbond Date 2023-02-28 Time 14:31 Sent To  
Notes
2023-02-28 14:36:54BUILDING REVIEW COMMENTS:
  
 W.P.B. PERMIT: 22121199
 REVIEWED: FEBRUARY 28, 2023
  
 FLORIDA BUILDING CODE,7TH EDITION (2020)
 FBC[AMENDED] = 2017 CHAPTER 1 WPB AMENDMENTS (SEE LINK
 BELOW)
 HTTPS://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/
 BUILDING-PERMIT-FORMS
 FBC BUILDING
 FBC EXISTING BUILDING
 FBC EB 706.8
  
 COMMENTS:
  
 1) PLEASE PROVIDE STRAP DETAILS.
 2) INCLUDE ENGINEERING PLAN WITH STRAP LOCATION.
  
 IF YOU HAVE ANY QUESTIONS OR CONCERNS, PLEASE DO NOT
 HESITATE TO CONTACT ME
  
 LOUIS BOND, AIA
 BUILDING PLANS EXAMINER II
 DEVELOPMENT SERVICES DEPT.
 BUILDING DIVISION
 401 CLEMATIS STREET
 WEST PALM BEACH, FLORIDA 33401
 PH: 561-805-6729
 FX: 561-805-6676
 EMAIL: [email protected]
  
  
 NOTES:
 PLEASE PROVIDE COMMENT RESPONSE SHEET TO EXPLAIN HOW
 EACH COMMENT IS BEING ADDRESSED.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2022-12-29 Cont ID  
Sent By jbrooks Date 2022-12-29 Time 09:12 Rev Time 0.00
Received By jbrooks Date 2022-12-29 Time 07:42 Sent To  
Notes
2022-12-29 09:13:13JONATHAN BROOKS JR.
 BUILDING PLANS EXAMINER
 WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM
 PHONE (561) 805-6656
 EMAIL: [email protected]
  
 1ST REVIEW: FBC 2020 7TH EDITION
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
 TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT
 CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX.
  
 1. FBC B 107.2.1. REVISE SUBMITTED FASTENER DENSITY
 CALCULATIONS PREPARED, SIGNED AND SEALED BY A FLORIDA
 REGISTERED PROFESSIONAL ENGINEER; TO THE CORRECT
 PROJECT ADDRESS 308 MONROE DR. WEST PALM BEACH, FLORIDA
 33405
 2. FBC B 107.2.1 FBC EB 706.1 SUBMITTED ROOF
 DRAWING/SKETCH LISTS FLAT/LOW ROOF SLOPE AS 0:12 IN
 AREAS B & C; LOW SLOPE ROOFS MUST SHOW POSITIVE
 DRAINAGE. PROVIDE METHOD OF PROVIDING POSITIVE
 DRAINAGE.
 3. FBC EB 706.8. SHOW THAT THE VALUE OF THE STRUCTURE
 IS LESS THAN $300,000.00 OR SPECIFY HOW THE ROOF TO
 WALL CONNECTIONS WILL BE IMPROVED.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  

Review Stop HIST HISTORICAL
Rev No 2 Status N Date 2023-01-31 Cont ID  
Sent By jbrooks Date 2023-01-31 Time 14:46 Rev Time 0.00
Received By jbrooks Date 2023-01-31 Time 14:45 Sent To  
Notes
2023-01-31 14:46:43*FLAT ROOF ONLY*

Review Stop HIST HISTORICAL
Rev No 1 Status N Date 2022-12-29 Cont ID  
Sent By jbrooks Date 2022-12-29 Time 09:13 Rev Time 0.00
Received By jbrooks Date 2023-01-31 Time 14:47 Sent To  
Notes
2022-12-29 09:13:52*FLAT ROOF ONLY*

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2023-04-03 Cont ID  
Sent By jbrooks Date 2023-04-03 Time 11:15 Rev Time 0.00
Received By jbrooks Date 2023-03-23 Time 15:17 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2023-03-22 Cont ID  
Sent By jbrooks Date 2023-03-22 Time 12:31 Rev Time 0.00
Received By jbrooks Date 2023-03-13 Time 16:05 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2023-02-16 Cont ID  
Sent By aoliver Date 2023-02-16 Time 09:43 Rev Time 0.00
Received By aoliver Date 2023-02-15 Time 11:23 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2023-01-31 Cont ID  
Sent By jbrooks Date 2023-01-31 Time 14:47 Rev Time 0.00
Received By jbrooks Date 2023-01-18 Time 11:04 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-12-29 Cont ID  
Sent By jbrooks Date 2022-12-29 Time 09:14 Rev Time 0.00
Received By jbrooks Date 2022-12-28 Time 08:04 Sent To  
Notes
***NONE***

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 3 Status P Date 2023-02-27 Cont ID  
Sent By dbattles Date 2023-02-27 Time 16:52 Rev Time 0.00
Received By dbattles Date 2023-02-27 Time 16:52 Sent To  
Notes
2023-02-27 16:53:25PRIVATE PROVIDER INSPECTIONS ONLY.

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 2 Status F Date 2023-02-16 Cont ID  
Sent By jbaker Date 2023-02-16 Time 08:55 Rev Time 0.00
Received By jbaker Date 2023-02-16 Time 08:51 Sent To  
Notes
2023-02-16 08:54:49SEE 1.24/23 CTHROOP COMMENTS: THESE COMMENTS HAVE NOT
 BEEN SATISFIED.
  
 AFFIDAVIT DOES NOT IDENTIFY EACH SHEET REVIEWED. THE
 AFFIDAVIT ONLY GIVES A NUMERICAL VALUE OF 4 SHEETS
 REVIEWED, BUT DOES NOT IDENTIFY THEM.

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 1 Status F Date 2023-01-24 Cont ID  
Sent By cthroop Date 2023-01-24 Time 16:49 Rev Time 0.00
Received By cthroop Date 2023-01-24 Time 16:31 Sent To  
Notes
2023-01-24 16:55:09PRIVATE PROVIDER PER F.S. 553.791
  
 CHRISTOPHER S. THROOP, C.B.O., CFM
 PLANS EXAMINER II PX3169/SFP306
 BU1635 BN4338
 ASFPM CFM US-21-11935
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 NFPA 70 2017 EDITION NEC 2017
  
 1ST REVIEW
  
 RESULTS: CORRECTIONS NEEDED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. PROVIDE A LIST OF THE PLAN SHEETS REVIEWED ON THE
 PLAN COMPLIANCE AFFIDAVIT.
 PRIVATE PROVIDER PER F.S. 553.791
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2023-02-28 Cont ID  
Sent By lbond Date 2023-02-28 Time 14:30 Rev Time 0.00
Received By lbond Date 2023-02-28 Time 14:30 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2022-12-29 Cont ID  
Sent By jbrooks Date 2022-12-29 Time 08:54 Rev Time 0.00
Received By jbrooks Date 2022-12-29 Time 08:49 Sent To  
Notes
2022-12-29 08:54:53JONATHAN BROOKS JR.
 BUILDING PLANS EXAMINER
 WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM
 PHONE (561) 805-6656
 EMAIL: [email protected]
  
 1ST REVIEW: FBC 2020 7TH EDITION
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC
 RESULTS: DENIED
  
 SUBMITTED SIGNED AND SEALED ENHANCED NAILING
 CALCULATIONS CAN NOT BE VERIFIED IT APPEARS TO BE A
 COPY OF A DIGITALLY SIGNED DOCUMENT. PLEASE UPLOAD A
 VALID ELECTRONICALLY SIGNED PLAN/DOCUMENT TO
 PROJECTDOX.
  
 FS471, DOCUMENTS PREPARED BY AN ENGINEER AND SUBMITTED
 FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED, DATED
 ORIGINALS. A SCAN OF A SIGNED PLAN IS NOT CONSIDERED AN
 ORIGINAL.
 PLEASE UPLOAD A VALID ELECTRONICALLY SIGNED
 PLAN/DOCUMENT TO PROJECTDOX
 PAPER PLANS/DOCUMENTS FOR SIGNATURE REVIEW WILL NO
 LONGER BE ACCEPTED BY THE CITY OF WEST PALM BEACH
 BUILDING DEPRTMENT.
  
 FEEL FREE TO CONTACT ME IF YOU WISH TO DISCUSS,
 561-805-6656.
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved