Plan Review Stops For Permit 22121142 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2023-04-28 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2023-04-28 |
Time |
13:08 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2023-04-28 |
Time |
13:08 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2023-04-14 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2023-04-14 |
Time |
16:31 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2023-04-14 |
Time |
16:31 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2023-04-04 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2023-04-04 |
Time |
16:34 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2023-04-04 |
Time |
16:34 |
Sent To |
|
|
Notes |
2023-04-04 16:35:44 | PLAN | | REVIEW COMMENTS | | | | 2ND REVIEW: FBC SEVENTH EDITION (2020) | | ROBERT MCDOUGAL, CBO | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561) 805-6714 | | [email protected] | | | | DENIED BY BUILDING | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | 1) NOT RESOLVED. SUBMIT GENERATOR PAD DRAWINGS WITH | | GENERATOR TO PAD ANCHORING DETAILS. IF A PREFABRICATED | | GENERATOR PAD WILL BE USED, SUBMIT SIGNED AND SEALED | | SITE SPECIFIC ENGINEERING FOR IT. FBC AMENDMENTS | | 107.2.1 | | | | 2) NOT RESOLVED. THE GENERATOR IS LOCATED IN A SPECIAL | | FLOOD HAZARD AREA. THE GENERATOR IS REQUIRED TO BE AT | | OR ABOVE THE FINISH FLOOR ELEVATION OF THE HABITABLE | | SPACE OF THE DWELLING OR THE BFE PLUS 2 FEET. THE BFE | | IS 6 FT NAVD AT THE GENERATOR'S PROPOSED LOCATION. | | | | 3) NOT RESOLVED. THE GENERATOR EXHAUST IS REQUIRED TO | | BE AT LEAST 10 FEET FROM ANY OPENINGS INTO A BUILDING. | | R303.5.1 INTAKE OPENINGS. | | MECHANICAL AND GRAVITY OUTDOOR AIR INTAKE OPENINGS | | SHALL BE LOCATED NOT LESS THAN 10 FEET (3048 MM) FROM | | ANY HAZARDOUS OR NOXIOUS CONTAMINANT, SUCH AS VENTS, | | CHIMNEYS, PLUMBING VENTS, STREETS, ALLEYS, PARKING LOTS | | AND LOADING DOCKS. | | | | 4) PLEASE SUBMIT A RESPONSE LETTER INDICATING HOW EACH | | OF THE REVIEW COMMENTS HAS BEEN ADDRESSED. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2023-02-15 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2023-02-15 |
Time |
08:39 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2023-02-15 |
Time |
08:39 |
Sent To |
|
|
Notes |
2023-02-15 09:05:20 | PLAN | | REVIEW COMMENTS | | | | 1ST REVIEW: FBC SEVENTH EDITION (2020) | | ROBERT MCDOUGAL, CBO | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561) 805-6714 | | [email protected] | | | | DENIED BY BUILDING | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | 1) SUBMIT GENERATOR PAD DRAWINGS WITH GENERATOR TO PAD | | ANCHORING DETAILS. IF A PREFABRICATED GENERATOR PAD | | WILL BE USED, SUBMIT SIGNED AND SEALED SITE SPECIFIC | | ENGINEERING FOR IT. FBC AMENDMENTS 107.2.1 | | | | 2) THE GENERATOR IS LOCATED IN A SPECIAL FLOOD HAZARD | | AREA. THE GENERATOR IS REQUIRED TO BE AT OR ABOVE THE | | FINISH FLOOR ELEVATION OF THE HABITABLE SPACE OF THE | | DWELLING OR THE BFE PLUS 2 FEET. THE BFE IS 6 FT NAVD | | AT THE GENERATOR'S PROPOSED LOCATION. | | | | 3) THE GENERATOR EXHAUST IS REQUIRED TO BE AT LEAST 10 | | FEET FROM ANY OPENINGS INTO A BUILDING. R303.5.1 INTAKE | | OPENINGS. | | MECHANICAL AND GRAVITY OUTDOOR AIR INTAKE OPENINGS | | SHALL BE LOCATED NOT LESS THAN 10 FEET (3048 MM) FROM | | ANY HAZARDOUS OR NOXIOUS CONTAMINANT, SUCH AS VENTS, | | CHIMNEYS, PLUMBING VENTS, STREETS, ALLEYS, PARKING LOTS | | AND LOADING DOCKS. | | | | 4) PLEASE SUBMIT A RESPONSE LETTER INDICATING HOW EACH | | OF THE REVIEW COMMENTS HAS BEEN ADDRESSED. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2023-04-19 |
|
|
Cont ID |
|
Sent By |
rperdomo |
Date |
2023-04-19 |
Time |
16:36 |
Rev Time |
0.00 |
Received By |
rperdomo |
Date |
2023-04-19 |
Time |
15:37 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2023-03-28 |
|
|
Cont ID |
|
Sent By |
rperdomo |
Date |
2023-03-28 |
Time |
14:42 |
Rev Time |
0.00 |
Received By |
rperdomo |
Date |
2023-03-28 |
Time |
14:31 |
Sent To |
|
|
Notes |
2023-03-28 14:42:04 | FLORIDA BUILDING CODE 2020 7TH EDITION | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED | | NFPA 70 2017 EDITION | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW | | | | 1. VALUE FOR WORK STATED ON PERMIT APPLICATION APPEARS | | LOW. PROVIDE A BREAKDOWN OF ALL MATERIALS AND LABOR, | | OR, AT YOUR DISCRETION, PROVIDE A SIGNED CONTRACTOR | | PROVIDE A | | REASONABLE VALUE. WPB F.B.C. 109.3 | | | | END OF COMMENTS | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM. | | | | RUBEN PEREZ PERDOMO, P.E. | | ELECTRICAL PLANS EXAMINER | | 561-805-6738 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2023-02-03 |
|
|
Cont ID |
|
Sent By |
rperdomo |
Date |
2023-02-03 |
Time |
13:54 |
Rev Time |
0.00 |
Received By |
rperdomo |
Date |
2023-02-03 |
Time |
13:28 |
Sent To |
|
|
Notes |
2023-02-03 13:57:40 | FLORIDA BUILDING CODE 2020 7TH EDITION | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED | | NFPA 70 2017 EDITION | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW | | | | 1. VALUE FOR WORK STATED ON PERMIT APPLICATION APPEARS | | LOW. PROVIDE A BREAKDOWN OF ALL MATERIALS AND LABOR, | | OR, AT YOUR DISCRETION, PROVIDE A SIGNED CONTRACTOR | | PROVIDE A | | REASONABLE VALUE. WPB F.B.C. 109.3 | | | | END OF COMMENTS | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM. | | | | RUBEN PEREZ PERDOMO, P.E. | | ELECTRICAL PLANS EXAMINER | | 561-805-6738 | | [email protected] | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
3 |
Status |
P |
Date |
2023-04-21 |
|
|
Cont ID |
|
Sent By |
rwbrown |
Date |
2023-04-21 |
Time |
08:19 |
Rev Time |
0.00 |
Received By |
rwbrown |
Date |
2023-04-21 |
Time |
08:19 |
Sent To |
|
|
Notes |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
2 |
Status |
P |
Date |
2023-03-21 |
|
|
Cont ID |
|
Sent By |
rwbrown |
Date |
2023-03-21 |
Time |
06:04 |
Rev Time |
0.00 |
Received By |
rwbrown |
Date |
2023-03-21 |
Time |
06:04 |
Sent To |
|
|
Notes |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
F |
Date |
2023-01-26 |
|
|
Cont ID |
|
Sent By |
rwbrown |
Date |
2023-01-26 |
Time |
08:45 |
Rev Time |
0.00 |
Received By |
rwbrown |
Date |
2023-01-26 |
Time |
08:43 |
Sent To |
|
|
Notes |
2023-01-26 08:49:37 | 1ST GAS REVIEW | | | | THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED | | BY RYAN BROWN WITH THE FOLLOWING COMMENTS. | | | | 1. 2017 WPB AMEND 107.3.5.3 (13) - GAS PLANS FOR MASTER | | PERMIT 22040542 DO NOT INCLUDE A ROUGH IN FOR A FUTURE | | GENERATOR. A GAS DRAWING WILL BE NEEDED FOR THIS PERMIT | | FOR THE ROUGH IN OF THE GAS TO THIS GENERATOR. INCLUDE | | THE EXISTING SYSTEM WITH THE NEW GAS LINE TO INCLUDE | | PIPE SIZING AND SYSTEM PRESSURES WHERE APPLICABLE FOR | | REVIEW. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM. | | | | | | RYAN W. BROWN | | CHIEF PLUMBING INSPECTOR | | OFFICE: 561-805-6692 | | CELL: 561-517-4293 | | EMAIL: [email protected] | | | | | | V7 FPC - 2020 FLORIDA PLUMBING CODE | | V7 FGC - 2020 FLORIDA FUEL GAS | | V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE | | V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE | | V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE | | V7 FEC - 2020 FLORIDA ENERGY CONSERVATION | | 2021 F.S. - 2021 FLORIDA STATUTES | | 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE | | 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE | | FBC CHAPTER 1 | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2023-04-28 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2023-04-28 |
Time |
13:09 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2023-04-20 |
Time |
17:43 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2023-04-20 |
|
|
Cont ID |
|
Sent By |
aoliver |
Date |
2023-04-20 |
Time |
07:56 |
Rev Time |
0.00 |
Received By |
aoliver |
Date |
2023-04-12 |
Time |
18:16 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2023-04-04 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2023-04-04 |
Time |
16:36 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2023-03-17 |
Time |
12:36 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2023-02-15 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2023-02-15 |
Time |
09:05 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2023-01-25 |
Time |
09:17 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
N |
Date |
2023-04-21 |
|
|
Cont ID |
|
Sent By |
rwbrown |
Date |
2023-04-21 |
Time |
08:17 |
Rev Time |
0.00 |
Received By |
rwbrown |
Date |
2023-04-21 |
Time |
08:17 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
N |
Date |
2023-03-21 |
|
|
Cont ID |
|
Sent By |
rwbrown |
Date |
2023-03-21 |
Time |
06:04 |
Rev Time |
0.00 |
Received By |
rwbrown |
Date |
2023-03-21 |
Time |
06:04 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
N |
Date |
2023-01-26 |
|
|
Cont ID |
|
Sent By |
rwbrown |
Date |
2023-01-26 |
Time |
08:44 |
Rev Time |
0.00 |
Received By |
rwbrown |
Date |
2023-01-26 |
Time |
08:43 |
Sent To |
|
|
Notes |
|
|
Review Stop |
PRIVATEPRV |
PRIVATE PROVIDER DOCUMENTS |
Rev No |
1 |
Status |
P |
Date |
2022-12-27 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2022-12-27 |
Time |
10:31 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2022-12-27 |
Time |
10:31 |
Sent To |
|
|
Notes |
2022-12-27 10:31:59 | INSPECTIONS | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
4 |
Status |
P |
Date |
2023-04-28 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2023-04-28 |
Time |
13:08 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2023-04-28 |
Time |
13:08 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
3 |
Status |
F |
Date |
2023-04-14 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2023-04-14 |
Time |
16:40 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2023-04-14 |
Time |
16:40 |
Sent To |
|
|
Notes |
2023-04-14 16:46:11 | THE DIGITAL SIGNATURES ON THE STRUCTURAL DRAWING AND | | THE SITE PLAN COULD NOT BE VERIFIED. ELECTRONICALLY | | SUBMITTED DRAWINGS ARE REQUIRED TO HAVE THE ARCHITECT | | OR ENGINEER'S DIGITAL SIGNATURE ON THEM. YOU ALSO HAVE | | THE OPTION TO SUBMIT THE SIGNED AND SEALED PAPER | | VERSION OF DRAWINGS. AFTER THE ELECTRONIC PLANS HAVE | | BEEN APPROVED, YOU CAN SUBMIT THE CORRESPONDING PAPER | | DRAWINGS AT THE BUILDING DEPARTMENT TO BE VERIFIED. THE | | ARCHITECT OR ENGINEER'S ORIGINAL HANDWRITTEN SIGNATURE | | AND SEAL IS REQUIRED TO BE ON THE DRAWINGS. NO | | PHOTOCOPY OR OTHER FACSIMILES OF THE SIGNATURE ARE | | ACCEPTABLE. FS 481 & FAC 61G1 OR FS 471 & FAC 61G15 |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2023-04-04 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2023-04-04 |
Time |
16:36 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2023-04-04 |
Time |
16:35 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2023-02-15 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2023-02-15 |
Time |
08:40 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2023-02-15 |
Time |
08:40 |
Sent To |
|
|
Notes |
2023-02-15 08:42:06 | THE ARCHITECT OR ENGINEER'S DIGITAL SIGNATURE IS | | REQUIRED ON THEIR DRAWINGS. ELECTRONICALLY SUBMITTED | | DRAWINGS ARE REQUIRED TO HAVE THE ARCHITECT OR | | ENGINEER'S DIGITAL SIGNATURE ON THEM. FS 481 & FAC 61G1 | | OR FS 471 & FAC 61G15 | | | | | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
4 |
Status |
P |
Date |
2023-04-24 |
|
|
Cont ID |
|
Sent By |
asangele |
Date |
2023-04-24 |
Time |
15:53 |
Rev Time |
0.00 |
Received By |
asangele |
Date |
2023-04-24 |
Time |
15:53 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2023-04-14 |
|
|
Cont ID |
|
Sent By |
asangele |
Date |
2023-04-14 |
Time |
16:49 |
Rev Time |
0.00 |
Received By |
asangele |
Date |
2023-04-14 |
Time |
16:49 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2023-03-27 |
|
|
Cont ID |
|
Sent By |
asangele |
Date |
2023-03-27 |
Time |
14:59 |
Rev Time |
0.00 |
Received By |
asangele |
Date |
2023-03-27 |
Time |
15:09 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2023-01-30 |
|
|
Cont ID |
|
Sent By |
asangele |
Date |
2023-01-30 |
Time |
15:38 |
Rev Time |
0.00 |
Received By |
asangele |
Date |
2023-01-30 |
Time |
15:38 |
Sent To |
|
|
Notes |
2023-01-30 15:39:19 | 1/30/2023 | | FAILED | | | | PLEASE LABEL SETBACK OF GENERATOR ON PLANS. | | | | ALEXIS SANGELEER | | PLANNER | | [email protected] |
|
|