Plan Review Details - Permit 22121129
Plan Review Stops For Permit 22121129
Review Stop AD ADDRESSING
Rev No 1 Status P Date 2023-01-03 Cont ID  
Sent By cpuell Date 2023-01-03 Time 13:16 Rev Time 0.00
Received By cpuell Date 2023-01-03 Time 13:16 Sent To  
Notes
2023-01-03 13:16:46ADDRESS APPROPRIATE FOR PROJECT.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2023-01-13 Cont ID  
Sent By pvalenti Date 2023-01-13 Time 16:58 Rev Time 0.00
Received By pvalenti Date 2023-01-13 Time 16:58 Sent To  
Notes
2023-01-13 16:58:54PETER E VALENTI
 BUILDING PLANS EXAMINER II/INSPECTOR
 [email protected]
 561 805 6673
  
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC M = FBC MECHANICAL
 FBC FG = FBC FUEL GAS
  
 BUILDING REVIEW DENIED:
  
 1.) FBC B 107.2.1, PLEASE PROVIDE SQUARE FOOT SIZES FOR
 EACH LETTER FOR EACH TYPE (PYLON, TENANT MONUMENT, AND
 MONUMENT) OF SIGN. THIS INFORMATION NEEDS TO CORRELATE
 WITH THE SIGNED/SEALED ENGINEERING SHEET.
 2.) FBC B 107.2.1, ALSO PROVIDE, AN UPDATED ENGINEERING
 SHEET THAT HAS A NEW 3RD PARTY VERIFIABLE
 SIGNATURE/SEAL AS ENGINEER'S NOTE STATES, " FOR PERMIT
 USE WITHIN 14 DAYS OF DIGITAL SEAL".
 3.) A MAXIMUM HEIGHT AND A MAXIMUM WIDTH OF EACH LETTER
 OR PROVIDE A NOTE STATING THAT MAXIMUM HEIGHTS AND
 WIDTHS ARE NOT REQUIRED.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2022-12-30 Cont ID  
Sent By mpeterso Date 2022-12-30 Time 12:38 Rev Time 0.00
Received By mpeterso Date 2022-12-30 Time 11:13 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By lmarchan Date 2022-12-13 Time 13:03 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2023-01-13 Cont ID  
Sent By pvalenti Date 2023-01-13 Time 17:01 Rev Time 0.00
Received By pvalenti Date 2023-01-13 Time 17:01 Sent To  
Notes
2023-01-13 17:02:12SIGNATURE REVIEW DENIED:
  
 THE DIGITALLY SIGNED ENGINEERING SHEET IS ONLY VALID
 FOR PERMIT USE WITHIN 14 DAYS OF DIGITAL SEAL.
  
 FS 471/FS 481 DOCUMENTS PREPARED BY AN
 ENGINEER/ARCHITECT AND SUBMITTED FOR PUBLIC RECORD ARE
 TO BE SIGNED, SEALED & DATED ORIGINALS. A SCAN OF A
 SIGNED/SEALED PLAN IS NOT CONSIDERED AN ORIGINAL.
 UPLOAD OR EMAIL A DIGITALLY SIGNED (THIRD PARTY
 VERIFIED) PLAN:
  
 PETER E VALENTI
 BUILDING PLANS EXAMINER II
 BUILDING DIVISION
 CITY OF WEST PALM BEACH
 401 CLEMATIS STREET, 1ST FLOOR
 WEST PALM BEACH, FL 33401
 FEEL FREE TO CONTACT ME AT 561 805 6673.
  

Review Stop Z ZONING
Rev No 1 Status   Date   Cont ID  
Sent By ajonesva Date   Time   Rev Time 0.00
Received By ajones Date 2023-05-12 Time 12:48 Sent To  
Notes
***NONE***