Plan Review Details - Permit 22121129
Plan Review Stops For Permit 22121129 |
Review Stop |
AD |
ADDRESSING |
Rev No |
1 |
Status |
P |
Date |
2023-01-03 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2023-01-03 |
Time |
13:16 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2023-01-03 |
Time |
13:16 |
Sent To |
|
|
Notes |
2023-01-03 13:16:46 | ADDRESS APPROPRIATE FOR PROJECT. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2023-01-13 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2023-01-13 |
Time |
16:58 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2023-01-13 |
Time |
16:58 |
Sent To |
|
|
Notes |
2023-01-13 16:58:54 | PETER E VALENTI | | BUILDING PLANS EXAMINER II/INSPECTOR | | [email protected] | | 561 805 6673 | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | FBC B = FBC BUILDING | | FBC R = FBC RESIDENTIAL | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC M = FBC MECHANICAL | | FBC FG = FBC FUEL GAS | | | | BUILDING REVIEW DENIED: | | | | 1.) FBC B 107.2.1, PLEASE PROVIDE SQUARE FOOT SIZES FOR | | EACH LETTER FOR EACH TYPE (PYLON, TENANT MONUMENT, AND | | MONUMENT) OF SIGN. THIS INFORMATION NEEDS TO CORRELATE | | WITH THE SIGNED/SEALED ENGINEERING SHEET. | | 2.) FBC B 107.2.1, ALSO PROVIDE, AN UPDATED ENGINEERING | | SHEET THAT HAS A NEW 3RD PARTY VERIFIABLE | | SIGNATURE/SEAL AS ENGINEER'S NOTE STATES, " FOR PERMIT | | USE WITHIN 14 DAYS OF DIGITAL SEAL". | | 3.) A MAXIMUM HEIGHT AND A MAXIMUM WIDTH OF EACH LETTER | | OR PROVIDE A NOTE STATING THAT MAXIMUM HEIGHTS AND | | WIDTHS ARE NOT REQUIRED. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2022-12-30 |
|
|
Cont ID |
|
Sent By |
mpeterso |
Date |
2022-12-30 |
Time |
12:38 |
Rev Time |
0.00 |
Received By |
mpeterso |
Date |
2022-12-30 |
Time |
11:13 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2022-12-13 |
Time |
13:03 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2023-01-13 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2023-01-13 |
Time |
17:01 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2023-01-13 |
Time |
17:01 |
Sent To |
|
|
Notes |
2023-01-13 17:02:12 | SIGNATURE REVIEW DENIED: | | | | THE DIGITALLY SIGNED ENGINEERING SHEET IS ONLY VALID | | FOR PERMIT USE WITHIN 14 DAYS OF DIGITAL SEAL. | | | | FS 471/FS 481 DOCUMENTS PREPARED BY AN | | ENGINEER/ARCHITECT AND SUBMITTED FOR PUBLIC RECORD ARE | | TO BE SIGNED, SEALED & DATED ORIGINALS. A SCAN OF A | | SIGNED/SEALED PLAN IS NOT CONSIDERED AN ORIGINAL. | | UPLOAD OR EMAIL A DIGITALLY SIGNED (THIRD PARTY | | VERIFIED) PLAN: | | | | PETER E VALENTI | | BUILDING PLANS EXAMINER II | | BUILDING DIVISION | | CITY OF WEST PALM BEACH | | 401 CLEMATIS STREET, 1ST FLOOR | | WEST PALM BEACH, FL 33401 | | FEEL FREE TO CONTACT ME AT 561 805 6673. | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
Sent By |
ajonesva |
Date |
|
Time |
|
Rev Time |
0.00 |
Received By |
ajones |
Date |
2023-05-12 |
Time |
12:48 |
Sent To |
|
|
Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy