Plan Review Stops For Permit 22120760 |
Review Stop |
AD |
ADDRESSING |
Rev No |
1 |
Status |
P |
Date |
2023-01-24 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2023-01-24 |
Time |
15:39 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2023-01-24 |
Time |
15:39 |
Sent To |
|
|
Notes |
2023-01-24 15:41:12 | ADDRESS APPROPRIATE FOR PROJECT. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2023-03-15 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2023-03-15 |
Time |
11:02 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2023-03-15 |
Time |
11:02 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2023-03-03 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2023-03-03 |
Time |
15:38 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2023-03-03 |
Time |
15:38 |
Sent To |
|
|
Notes |
2023-03-03 15:38:43 | NEW SFR | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected] | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | AMENDMENT | | | | CORRECTIONS NEEDED - | | | | 1) PRODUCT APPROVAL 20-0729.06 FOR THE SLIDING GLASS | | DOOR NEEDS TO BE REVIEWED AND MARKED APPROVED BY THE | | BUILDING DESIGNER OF RECORD FBC WPB 107.3.4 | | | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2023-01-31 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2023-01-31 |
Time |
12:41 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2023-01-31 |
Time |
10:03 |
Sent To |
|
|
Notes |
2023-01-31 12:37:02 | NEW SFR | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected] | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | AMENDMENT | | | | CORRECTIONS NEEDED - | | | | 1) PRODUCT APPROVAL 20-0729.06 FOR THE SLIDING GLASS | | DOOR NEEDS TO BE REVIEWED AND MARKED APPROVED BY THE | | BUILDING DESIGNER OF RECORD FBC WPB 107.3.4 | | | | 2) PLEASE SHOW THE STORM WATER FLOW AWAY FROM THE | | BUILDING AND AWAY FROM THE ADJACENT PROPERTY ON THE | | SITE PLAN OR PROVIDE A STORM WATER DRAINAGE PLAN FBC | | WPB 107.2.5 SITE PLAN. THE CONSTRUCTION DOCUMENTS | | SUBMITTED WITH THE APPLICATION FOR PERMIT SHALL BE | | ACCOMPANIED BY A SITE PLAN SHOWING TO SCALE THE SIZE | | AND LOCATION OF NEW CONSTRUCTION AND EXISTING | | STRUCTURES ON THE SITE, DISTANCES FROM LOT LINES, THE | | ESTABLISHED STREET GRADES AND THE PROPOSED FINISHED | | GRADES, DEPICTING THE PROPOSED LOT DRAINAGE AND, AS | | APPLICABLE, FLOOD HAZARD AREAS, FLOODWAYS, AND DESIGN | | FLOOD ELEVATIONS; AND IT SHALL BE DRAWN IN ACCORDANCE | | WITH AN ACCURATE AND INCLUDED ON A BOUNDARY LINE | | SURVEY. (PLEASE PROVIDE CUT SECTIONS FOR ANY PROPOSED | | WATER RETAINING SWALES) | | | | 3) THE PROVIDED SOIL REPORT DOES NOT SHOW IN ADOBE | | READER AS DIGITALLY SIGNED - SIGNED AND SEALED DRAWINGS | | IN PROJECTDOX NEED TO BE DIGITALLY/ELECTRONICALLY | | SIGNED TO BE USED IN ELECTRONIC PLAN REVIEW. (A | | CERTIFICATE-BASED DIGITAL SIGNATURE (OFTEN JUST CALLED | | A DIGITAL SIGNATURE) IS A SPECIFIC TYPE OF | | E-SIGNATURE). |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2023-03-21 |
|
|
Cont ID |
|
Sent By |
rperdomo |
Date |
2023-03-21 |
Time |
14:10 |
Rev Time |
0.00 |
Received By |
rperdomo |
Date |
2023-03-21 |
Time |
13:47 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2023-03-02 |
|
|
Cont ID |
|
Sent By |
rperdomo |
Date |
2023-03-02 |
Time |
15:31 |
Rev Time |
0.00 |
Received By |
rperdomo |
Date |
2023-03-02 |
Time |
15:31 |
Sent To |
|
|
Notes |
2023-03-02 15:34:33 | FLORIDA BUILDING CODE 2020 7TH EDITION | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED | | NFPA 70 2017 EDITION | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW | | | | 1. REVIEW LOAD CALCULATION (AC UNITS). NEC 220.82 | | NOTE (A/C UNITS AT 100%) | | | | END OF COMMENTS | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM. | | | | RUBEN PEREZ PERDOMO, P.E. | | ELECTRICAL PLANS EXAMINER | | 561-805-6738 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2023-02-02 |
|
|
Cont ID |
|
Sent By |
rperdomo |
Date |
2023-02-02 |
Time |
15:47 |
Rev Time |
0.00 |
Received By |
rperdomo |
Date |
2023-02-02 |
Time |
13:38 |
Sent To |
|
|
Notes |
2023-02-02 15:47:45 | FLORIDA BUILDING CODE 2020 7TH EDITION | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED | | NFPA 70 2017 EDITION | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW | | | | 1. REVIEW LOAD CALCULATION (AC UNITS). NEC 220.82 | | 2. PROVIDE CORRECT EQUIPMENT GROUNDING CONDUCTOR (EGC) | | FOR POOL PANEL 60A POWERED FROM THE 'B' PANEL 150A. NEC | | TABLE 250.122 | | | | END OF COMMENTS | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM. | | | | RUBEN PEREZ PERDOMO, P.E. | | ELECTRICAL PLANS EXAMINER | | 561-805-6738 | | [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2023-03-22 |
|
|
Cont ID |
|
Sent By |
aoliver |
Date |
2023-03-22 |
Time |
10:08 |
Rev Time |
0.00 |
Received By |
aoliver |
Date |
2023-03-13 |
Time |
07:55 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2023-03-06 |
|
|
Cont ID |
|
Sent By |
asangele |
Date |
2023-03-06 |
Time |
16:35 |
Rev Time |
0.00 |
Received By |
asangele |
Date |
2023-03-06 |
Time |
16:35 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2023-02-06 |
|
|
Cont ID |
|
Sent By |
asangele |
Date |
2023-02-06 |
Time |
15:53 |
Rev Time |
0.00 |
Received By |
asangele |
Date |
2023-02-06 |
Time |
15:53 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
P |
Date |
2023-04-06 |
|
|
Cont ID |
|
Sent By |
aoliver |
Date |
2023-04-06 |
Time |
08:21 |
Rev Time |
0.00 |
Received By |
aoliver |
Date |
2023-03-22 |
Time |
10:09 |
Sent To |
|
|
Notes |
2023-03-31 11:55:13 | RECEIPT MU-2023-012465-0000 $459.33 PAID | 2023-03-22 10:09:44 | EMAILED IMPACT FOR REVIEW-AO |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2023-01-31 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2023-01-31 |
Time |
12:40 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2023-01-31 |
Time |
12:40 |
Sent To |
|
|
Notes |
2023-01-31 12:41:19 | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF | | | | UPON APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE | | RECEIPT TO YOUR PROJECT OR EMAIL IT TO | | [email protected] . | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2023-03-14 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2023-03-14 |
Time |
09:14 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2023-03-14 |
Time |
09:14 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2023-03-01 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2023-03-01 |
Time |
12:36 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2023-03-01 |
Time |
12:36 |
Sent To |
|
|
Notes |
2023-03-01 12:38:02 | THE DESIGNER OF THE MECHANICAL SHEET M-1 DID NOT SIGN | | THE DRAWING. PLEASE ADD YOUR SIGNATURE TO THE DRAWING. | | FBC AMENDMENT 107.2.1 | | | | MICHAEL EDWARDS | | MECHANICAL EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL. 33401 | | 561-805-6728 | | [email protected] | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2023-01-27 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2023-01-27 |
Time |
11:46 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2023-01-27 |
Time |
11:46 |
Sent To |
|
|
Notes |
2023-01-27 11:46:27 | 1ST REVIEW FMC | | PERMIT: 22120760 | | | | CODES IN EFFECT: 2020 | | | | FBC- FLORIDA BUILDING CODE | | FMC- FLORIDA MECHANICAL CODE | | FEC- FLORIDA ENERGY CONSERVATION | | FGC- FLORIDA FUEL GAS | | FEX- FLORIDA EXISTING BUILDING CODE | | FRC- FLORIDA RESIDENTIAL BUILDING CODE | | F.S.- FLORIDA STATUTES | | FAC- FLORIDA ACCESSIBILITY CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) PROVIDE THE ENERGY CALCULATIONS. FEC R101.5.1.1.1 | | | | 2) PROVIDE THE MECHANICAL EQUIPMENT SIZING | | CALCULATIONS. FEC R403.7.1 | | | | 3) SHEET M-1: THE DRYER DUCT MUST MEET THE MATERIAL | | SPECIFIED IN FRC M1502.4 | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM. | | | | MICHAEL EDWARDS | | MECHANICAL EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL. 33401 | | 561-805-6728 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2023-02-28 |
|
|
Cont ID |
|
Sent By |
rwbrown |
Date |
2023-02-28 |
Time |
09:27 |
Rev Time |
0.00 |
Received By |
rwbrown |
Date |
2023-02-28 |
Time |
09:27 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2023-01-26 |
|
|
Cont ID |
|
Sent By |
rwbrown |
Date |
2023-01-26 |
Time |
09:43 |
Rev Time |
0.00 |
Received By |
rwbrown |
Date |
2023-01-26 |
Time |
09:43 |
Sent To |
|
|
Notes |
2023-01-26 09:43:49 | 1ST PLUMBING REVIEW | | | | THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED | | BY RYAN BROWN WITH THE FOLLOWING COMMENTS. | | | | 1. ISOMETRIC - UPSTAIRS BATH #4 - 2020 FRC P3108.2.1 - | | WATER CLOSET AND SHOWER ARE NOT VENTED TO CODE. ONLY | | ONE FIXTURE IS ALLOWED UPSTREAM OF THE VENTED FIXTURE'S | | CONNECTION TO THE HORIZONTAL BRANCH. RECONFIGURE | | BATHROOM. | | | | 2. ISOMETRIC - UPSTAIRS BATH #3 - 2017 WPB AMEND | | 107.3.5.3 (12) - THE TUB SEEMS TO BE MISSING FROM THE | | ISOMETRIC. | | | | 3. ISOMETRIC - DOWNSTAIRS BATH #2 - 2020 FRC P3108.2.1 | | - WATER CLOSET AND SHOWER ARE NOT VENTED TO CODE. ONLY | | ONE FIXTURE IS ALLOWED UPSTREAM OF THE VENTED FIXTURE'S | | CONNECTION TO THE HORIZONTAL BRANCH. RECONFIGURE | | BATHROOM. | | | | 4. ISOMETRIC - DOWNSTAIRS LAUNDRY ROOM - SECTION FRC | | P3112 - THE VENT FOR THE WASHING MACHINE IS | | INACCURATELY LABELED AS A LOOP VENT. BRANCH VENT IS | | MORE ACCURATE. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM. | | | | | | RYAN W. BROWN | | CHIEF PLUMBING INSPECTOR | | OFFICE: 561-805-6692 | | CELL: 561-517-4293 | | EMAIL: [email protected] | | | | | | V7 FPC - 2020 FLORIDA PLUMBING CODE | | V7 FGC - 2020 FLORIDA FUEL GAS | | V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE | | V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE | | V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE | | V7 FEC - 2020 FLORIDA ENERGY CONSERVATION | | 2021 F.S. - 2021 FLORIDA STATUTES | | 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE | | 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE | | FBC CHAPTER 1 | | |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
P |
Date |
2023-01-31 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2023-01-31 |
Time |
12:41 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2023-01-31 |
Time |
12:41 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
3 |
Status |
P |
Date |
2023-03-15 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2023-03-15 |
Time |
11:05 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2023-03-15 |
Time |
11:05 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2023-03-03 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2023-03-03 |
Time |
15:41 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2023-03-03 |
Time |
15:41 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2023-01-31 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2023-01-31 |
Time |
12:42 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2023-01-31 |
Time |
12:42 |
Sent To |
|
|
Notes |
2023-01-31 12:44:20 | SIGNATURE REVIEW | | | | CORRECTIONS NEEDED - | | | | 1) THE PROVIDED SOIL REPORT DOES NOT SHOW AS DIGITALLY | | SIGNED BY THE ENGINEER IN ADOBE READER - | | | | SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE | | DIGITALLY/ELECTRONICALLY SIGNED TO BE USED IN | | ELECTRONIC PLAN REVIEW. (A CERTIFICATE-BASED DIGITAL | | SIGNATURE (OFTEN JUST CALLED A DIGITAL SIGNATURE) IS A | | SPECIFIC TYPE OF E-SIGNATURE). | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2023-03-06 |
|
|
Cont ID |
|
Sent By |
asangele |
Date |
2023-03-06 |
Time |
16:35 |
Rev Time |
0.00 |
Received By |
asangele |
Date |
2023-03-06 |
Time |
16:35 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2023-02-06 |
|
|
Cont ID |
|
Sent By |
ASangele |
Date |
2023-02-06 |
Time |
14:16 |
Rev Time |
0.00 |
Received By |
asangele |
Date |
2023-02-06 |
Time |
14:15 |
Sent To |
|
|
Notes |
2023-02-06 15:52:58 | FAILED | | 2/6/2023 | | | | NEW CONSTRUCTIONS ARE REQUIRED TO HAVE A SEPARATE | | LANDSCAPE PERMIT IN THE SYSTEM. | | PLEASE REACH OUT TO SMITH (LANDSCAPE PLANNER) | | 561-822-1562 | | | | | | SEPARATE PERMIT REQUIRED/ WILL NOT BE INCLUDE IN THIS | | PERMIT | | | | FENCE/GATE | | * CANNOT EXCEED 4FT IN HEIGHT THE FIRST 25FT OF THE | | FRONT SETBACK. | | | | POOL/POOL DECK | | | | POOL/MECHANICAL EQUIPMENT | | * MECHANICAL EQUIPMENT MAY NOT PROJECT MORE THAN FOUR | | FEET INTO A SETBACK. | | | | | | DRIVEWAY | | * CIRCULAR DRIVEWAYS MAX WIDTH IS 10FT FOR BOTH | | OPENINGS THERE IS A MINIMUM RADUIS OF FIVE FEET | | * LESSER OF 1,000 SQUARE FEET OR 75 PERCENT OF THE | | FRONT YARD AREA SHALL BE LANDSCAPED WITH LIVING PLANT | | MATERIAL (SUCH AS GRASS, GROUND COVER, SHRUBS, HEDGES, | | VINES OR TREES). | | | | | | | | ALEXIS SANGELEER | | PLANNER | | [email protected] | | |
|
|