Plan Review Stops For Permit 22120724 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2023-01-25 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2023-01-25 |
Time |
06:45 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2023-01-25 |
Time |
05:42 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2023-01-19 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2023-01-19 |
Time |
16:52 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2023-01-19 |
Time |
14:54 |
Sent To |
|
|
Notes |
2023-01-19 17:21:40 | 1ST BUILDING REVIEW | | RESULTS: CORRECTIONS NEEDED | | | | CHRISTOPHER S. THROOP, CBO, BN, PX, CFM | | PLANS EXAMINER II | | CITY OF WEST PALM BEACH | | (561) 805-6726 | | [email protected] | | | | CODES IN EFFECT: | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | NFPA 70 2017 EDITION NEC 2017 | | | | ADDRESS THE FOLLOWING COMMENTS AND RE-SUBMIT: | | | | NOTICE: VALUE ADJUSTED TO $265,269 PER THE ICC BUILDING | | VALUATION DATA. | | | | 1. PROVIDE A SITE DRAINAGE PLAN PER FBC R401.3 | | IT SHALL BE DRAWN IN ACCORDANCE WITH AN ACCURATE AND | | INCLUDED BOUNDARY LINE SURVEY. | | FBC R401.3 SITE DRAINAGE | | | | 2. PROVIDE CURRENT PRODUCT APPROVALS OR NOA FOR | | PROPOSED HORIZONTAL SLIDERS AND SLIDING GLASS DOORS. | | PRODUCT APPROVALS INCLUDE THE COVER SHEET, EVALUATION | | REPORT AND INSTALLATION INSTRUCTIONS. | | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | | 3. PROVIDE THE ICC-ES REPORT FOR THE ICYNENE SPRAY FOAM | | INSULATION. | | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | | 4.PROVIDE LOCATION OF ATTIC ACCESS PER R807.1.7. | | R807.1.7 BUILDINGS WITH COMBUSTIBLE CEILING OR ROOF | | CONSTRUCTION SHALL HAVE AN ATTIC ACCESS OPENING TO | | ATTIC AREAS THAT HAVE A VERTICAL HEIGHT OF 30 INCHES | | (762 MM) OR GREATER OVER AN AREA OF NOT LESS THAN 30 | | SQUARE FEET (2.8 M2). | | | | 5.PROVIDE A FLASHING DETAIL FOR WINDOWS AND EXT. DOORS | | PER R703.4 | | EXTERIOR WINDOW AND DOOR OPENINGS. FLASHING AT EXTERIOR | | WINDOW AND DOOR OPENINGS SHALL EXTEND TO THE SURFACE OF | | THE EXTERIOR WALL FINISH OR TO THE WATER-RESISTIVE | | BARRIER COMPLYING WITH SECTION 703.2 FOR SUBSEQUENT | | DRAINAGE. | | | | 6.PROVIDE SMOKE ALARMS. | | FBC 1104.1SMOKE ALARMS IN EXISTING PORTIONS OF A | | BUILDING. | | SMOKE ALARMS | | R314.2.2ALTERATIONS, REPAIRS AND ADDITIONS. | | WHERE ALTERATIONS, REPAIRS OR ADDITIONS REQUIRING A | | PERMIT OCCUR, OR WHERE ONE OR MORE SLEEPING ROOMS ARE | | ADDED OR CREATED IN EXISTING DWELLINGS, THE INDIVIDUAL | | DWELLING UNIT SHALL BE EQUIPPED WITH SMOKE ALARMS | | LOCATED AS REQUIRED FOR NEW DWELLINGS. FBC R314. | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. | | | | | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2023-01-25 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2023-01-25 |
Time |
15:42 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2023-01-25 |
Time |
15:37 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2023-01-12 |
|
|
Cont ID |
|
Sent By |
fgiaquin |
Date |
2023-01-12 |
Time |
22:46 |
Rev Time |
0.00 |
Received By |
fgiaquin |
Date |
2023-01-12 |
Time |
21:25 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2023-01-25 |
|
|
Cont ID |
|
Sent By |
aoliver |
Date |
2023-01-25 |
Time |
16:23 |
Rev Time |
0.00 |
Received By |
aoliver |
Date |
2023-01-24 |
Time |
06:30 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2023-01-20 |
|
|
Cont ID |
|
Sent By |
vbroglia |
Date |
2023-01-20 |
Time |
12:03 |
Rev Time |
0.00 |
Received By |
vbroglia |
Date |
2023-01-11 |
Time |
07:58 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
P |
Date |
2023-01-31 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2023-01-31 |
Time |
15:08 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2023-01-25 |
Time |
10:55 |
Sent To |
|
|
Notes |
2023-01-31 13:13:29 | RECEIPT MU-2023-004127 - $2280.84 PAID | 2023-01-25 10:55:50 | 1/25/23 EMAILED IMPACT OFFICE TO REVIEW. LEM |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2023-01-19 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2023-01-19 |
Time |
15:17 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2023-01-19 |
Time |
14:54 |
Sent To |
|
|
Notes |
2023-01-19 15:18:13 | IMPACT FEES | | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | DIGITALLY VIA PROJECT DOX UPON NOTIFICATION BY THIS | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON | | APPROVAL AND FEE PAYMENT (IF ANY), PLEASE UPLOAD THE | | RECEIPT TO YOUR PROJECT OR EMAIL IT TO | | [email protected] . | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2023-01-25 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2023-01-25 |
Time |
08:06 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2023-01-25 |
Time |
08:06 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2023-01-12 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2023-01-12 |
Time |
17:01 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2023-01-12 |
Time |
17:01 |
Sent To |
|
|
Notes |
2023-01-12 17:01:15 | 1ST REVIEW FMC | | PERMIT: 22120724 | | | | CODES IN EFFECT: 2020 | | | | FBC- FLORIDA BUILDING CODE | | FMC- FLORIDA MECHANICAL CODE | | FEC- FLORIDA ENERGY CONSERVATION | | FGC- FLORIDA FUEL GAS | | FEX- FLORIDA EXISTING BUILDING CODE | | FRC- FLORIDA RESIDENTIAL BUILDING CODE | | F.S.- FLORIDA STATUTES | | FAC- FLORIDA ACCESSIBILITY CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) THE MECHANICAL SIZING CALCULATIONS ARE REQUIRING A | | 5- TON UNIT, THE A/C EQUIPMENT SCHEDULE IS ALSO CALLING | | FOR A 5-TON UNIT BUT THE MECHANICAL DRAWING IS SHOWING | | A 4- TON SYSTEM IN THE ATTIC. PLEASE MAKE SURE THE | | MECHANICAL SYSTEM IS CONSISTENT ON BOTH DOCUMENTS. FBC | | 107.3.5 | | | | 2) PROVIDE THE DUCT SIZES ON ALL DUCTWORK INCLUDING THE | | SUPPLY AND RETURN DUCTS AT THE MECHANICAL UNIT. FBC | | 107.3.5 | | | | 3) THE RANGE HOOD MUST MEET THE REQUIREMENTS OF FRC | | M1503.4 | | | | 4) SHOW THE DRYER EXHAUST DUCT SIZE AND TERMINATION | | LOCATION ON THE DRAWING. FRC M1502 | | | | 5) SHOW THE CONDENSATE DRAIN PIPE SIZE AND TERMINATION | | LOCATION ON THE DRAWING. FRC M1411.3 | | | | 6) SHOW THE BATH EXHAUST FAN, DUCT AND TERMINATION | | LOCATION ON THE DRAWING FOR THE BATHROOM NEAR THE | | WASHER AND DRYER. FRC R303.3 | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM. | | | | MICHAEL EDWARDS | | MECHANICAL EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL. 33401 | | 561-805-6728 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2023-01-25 |
|
|
Cont ID |
|
Sent By |
rwbrown |
Date |
2023-01-25 |
Time |
07:30 |
Rev Time |
0.00 |
Received By |
rwbrown |
Date |
2023-01-25 |
Time |
07:30 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2023-01-12 |
|
|
Cont ID |
|
Sent By |
rwbrown |
Date |
2023-01-12 |
Time |
10:50 |
Rev Time |
0.00 |
Received By |
rwbrown |
Date |
2023-01-12 |
Time |
10:50 |
Sent To |
|
|
Notes |
2023-01-12 10:51:56 | 1ST PLUMBING REVIEW | | | | THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED | | BY RYAN BROWN WITH THE FOLLOWING COMMENTS. | | | | 1. 2020 FRC P3108.1 - THE WASHING MACHINE FIXTURE DRAIN | | CANNOT CONNECT ABOVE THE SHOWER (WITHIN THE WET VENT). | | THE WASHING MACHINE IS NOT A BATHROOM GROUP FIXTURE AND | | CANNOT CONNECT WITHIN THE WET VENT SYSTEM. IT MUST | | DISHCHARGE DOWNSTREAM OF THE LAST BATHROOM GROUP | | FIXTURE BEING WET VENTED. (DOWNSTREAM OF THE SHOWER). | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM. | | | | | | RYAN W. BROWN | | CHIEF PLUMBING INSPECTOR | | OFFICE: 561-805-6692 | | CELL: 561-517-4293 | | EMAIL: [email protected] | | | | | | V7 FPC - 2020 FLORIDA PLUMBING CODE | | V7 FGC - 2020 FLORIDA FUEL GAS | | V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE | | V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE | | V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE | | V7 FEC - 2020 FLORIDA ENERGY CONSERVATION | | 2021 F.S. - 2021 FLORIDA STATUTES | | 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE | | 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE | | FBC CHAPTER 1 | | |
|
|
Review Stop |
PRIVATEPRV |
PRIVATE PROVIDER DOCUMENTS |
Rev No |
1 |
Status |
P |
Date |
2023-01-31 |
|
|
Cont ID |
|
Sent By |
dbattles |
Date |
2023-01-31 |
Time |
13:10 |
Rev Time |
0.00 |
Received By |
dbattles |
Date |
2023-01-31 |
Time |
13:10 |
Sent To |
|
|
Notes |
2023-01-31 13:11:24 | PRIVATE PROVIDER FOR INSPECTIONS | | CREDENTIALS APPROVED | | FEES ADJUSTED | | FILES TO RECORD |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
P |
Date |
2023-01-19 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2023-01-19 |
Time |
15:18 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2023-01-19 |
Time |
14:54 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2023-01-25 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2023-01-25 |
Time |
06:45 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2023-01-25 |
Time |
05:43 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
P |
Date |
2023-01-19 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2023-01-19 |
Time |
16:42 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2023-01-19 |
Time |
14:54 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2023-01-25 |
|
|
Cont ID |
|
Sent By |
vbroglia |
Date |
2023-01-25 |
Time |
08:50 |
Rev Time |
0.00 |
Received By |
vbroglia |
Date |
2023-01-25 |
Time |
08:50 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2023-01-20 |
|
|
Cont ID |
|
Sent By |
VBroglia |
Date |
2023-01-20 |
Time |
12:01 |
Rev Time |
0.00 |
Received By |
vbroglia |
Date |
2023-01-20 |
Time |
12:01 |
Sent To |
|
|
Notes |
2023-01-20 12:03:01 | PASSED WITH PROVISO: | | | | SEPERATE PERMIT REQUIRED FOR: | | FENCE/WALL, GENERATOR, MECHANICAL/AC/POOL EQUIPMENT, | | DRIVEWAY, POOLS, IRRIGATION, LANDSCAPE, OTHER. |
|
|