Plan Review Stops For Permit 22120613 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2023-04-04 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2023-04-04 |
Time |
13:58 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2023-04-04 |
Time |
12:51 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2023-03-23 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2023-03-23 |
Time |
12:28 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2023-03-23 |
Time |
08:04 |
Sent To |
|
|
Notes |
2023-03-23 12:29:24 | JONATHAN BROOKS JR. | | BUILDING PLANS EXAMINER | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | PHONE (561) 805-6656 | | EMAIL: [email protected] | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | FBC B = FBC BUILDING | | FBC R = FBC RESIDENTIAL | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX. | | | | 1. FBC B 107.2.1. REVISE SUBMITTED FASTENER DENSITY | | CALCULATIONS PREPARED, SIGNED AND SEALED BY A FLORIDA | | REGISTERED DESIGN PROFESSIONAL; TO INCLUDE NOA SYSTEM | | TYPE TO BE USED. A(1), B(2), E(3) ETC. | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2023-02-10 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2023-02-10 |
Time |
12:39 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2023-02-10 |
Time |
08:09 |
Sent To |
|
|
Notes |
2023-02-10 12:40:03 | JONATHAN BROOKS JR. | | BUILDING PLANS EXAMINER | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | PHONE (561) 805-6656 | | EMAIL: [email protected] | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | FBC B = FBC BUILDING | | FBC R = FBC RESIDENTIAL | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX. | | | | 1. PROVIDE A COMPLETE SET OF 2020 CODE VERSION PRODUCT | | APPROVALS/NOA'S FOR THE PROPOSED FLAT ROOF (CRICKET | | AREA) SYSTEM TO BE USED. INCLUDE COVER PAGE, EVALUATION | | REPORTS AND INSTALLATION INSTRUCTIONS FOR SYSTEM USED. | | ALL APPLICABLE DETAILS AND ATTACHMENTS MUST BE CLEARLY | | IDENTIFIED ON THE PRODUCT APPROVAL DRAWINGS. DETAILS | | AND ATTACHMENTS NOT SPECIFICALLY COVERED IN PRODUCT | | APPROVALS WILL NEED SITE-SPECIFIC ENGINEERING. | | 2. FBC R 905.1.1 ASPHALT SHINGLE, METAL, MINERAL | | SURFACE, SLATE AND SLATE-TYPE ROOFING MUST COMPLY WITH | | NEW 2020 BUILDING CODE UNDERLAYMENT REQUIREMENTS. | | PROVIDE METHOD OF COMPLIANCE. (IF USING DOUBLE 30# FELT | | INDICATE ON ROOF DRAWING/SKETCH). PLEASE NOTE: | | SUBMITTED MIAMI-DADE NOA NO 19-0610.01 ATLAS SPEC #30 | | WILL NOT SATIFY THIS REQUIREMENT WITH ONE LAYER. | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2023-01-10 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2023-01-10 |
Time |
08:25 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2023-01-10 |
Time |
07:39 |
Sent To |
|
|
Notes |
2023-01-10 08:26:20 | JONATHAN BROOKS JR. | | BUILDING PLANS EXAMINER | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | PHONE (561) 805-6656 | | EMAIL: [email protected] | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | FBC B = FBC BUILDING | | FBC R = FBC RESIDENTIAL | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX. | | | | 1. SUBMITTED MIAMI-DADE COUNTY NOA 18-0409.06 COVERS | | MULTIPLE PRODUCTS & APPROVED ASSEMBLIES: SYSTEMS E(1) | | THROUGH E(4). SELECT PRODUCT & SYSTEM TO BE USED. ALL | | APPLICABLE DETAILS AND ATTACHMENTS MUST BE CLEARLY | | IDENTIFIED ON THE PRODUCT APPROVAL DRAWINGS. | | 2. FBC B 107.2.1 FOR CLARITY PLEASE PROVIDE A ROOF | | DIAGRAM/SKETCH WITH THE AREAS TO RECEIVE NEW ROOFING | | CLEARLY IDENTIFIED ON DRAWING; INCLUDE ROOF SLOPE(S), | | MEAN ROOF HEIGHT(S). FLAT/LOW SLOPE ROOFS MUST SHOW | | POSITIVE DRAINAGE. | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2023-04-04 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2023-04-04 |
Time |
13:58 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2023-03-28 |
Time |
10:05 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2023-03-23 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2023-03-23 |
Time |
12:29 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2023-03-15 |
Time |
16:17 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2023-02-10 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2023-02-10 |
Time |
12:40 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2023-01-27 |
Time |
16:27 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2023-01-10 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2023-01-10 |
Time |
08:26 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2023-01-09 |
Time |
09:40 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2023-04-04 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2023-04-04 |
Time |
13:58 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2023-04-04 |
Time |
12:51 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2023-03-23 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2023-03-23 |
Time |
12:28 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2023-03-23 |
Time |
12:28 |
Sent To |
|
|
Notes |
2023-03-23 12:28:22 | JONATHAN BROOKS JR. | | BUILDING PLANS EXAMINER | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | PHONE (561) 805-6656 | | EMAIL: [email protected] | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | FBC B = FBC BUILDING | | FBC R = FBC RESIDENTIAL | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | RESULTS: DENIED | | | | PENDING REVISED DENSITY CALCULATIONS | | | | FS471, DOCUMENTS PREPARED BY AN ENGINEER AND SUBMITTED | | FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED, DATED | | ORIGINALS. A SCAN OF A SIGNED PLAN IS NOT CONSIDERED AN | | ORIGINAL. | | PLEASE UPLOAD A VALID ELECTRONICALLY SIGNED | | PLAN/DOCUMENT TO PROJECTDOX | | PAPER PLANS/DOCUMENTS FOR SIGNATURE REVIEW WILL NO | | LONGER BE ACCEPTED BY THE CITY OF WEST PALM BEACH | | BUILDING DEPRTMENT. | | | | FEEL FREE TO CONTACT ME IF YOU WISH TO DISCUSS, | | 561-805-6656. | | |
|
|