Plan Review Stops For Permit 22120578 |
Review Stop |
AD |
ADDRESSING |
Rev No |
1 |
Status |
P |
Date |
2022-12-13 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2022-12-13 |
Time |
11:18 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2022-12-13 |
Time |
11:18 |
Sent To |
|
|
Notes |
2022-12-13 11:19:30 | SIGN IS IN THE COMMON AREA, PRIMARY ADDRESS APPROPRIATE |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
7 |
Status |
P |
Date |
2023-07-11 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2023-07-11 |
Time |
09:43 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2023-07-11 |
Time |
09:23 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
6 |
Status |
F |
Date |
2023-06-16 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2023-06-16 |
Time |
14:28 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2023-06-15 |
Time |
17:41 |
Sent To |
|
|
Notes |
2023-06-16 14:29:12 | SEVENTH BUILDING REVIEW COMMENTS | | CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS. | | PERMIT #22120578 | | 6200 S DIXIE HWY | | | | NEW COMMENT BASED ON DRAWINGS SUBMITTED: | | | | 1- THE DESIGN CRITERIA SHOWN ON THE RIGHT HAND SIDE OF | | ALL THE DRAWINGS DOESN'T MATCH THE DESIGN CRITERIA | | CONSIDERED IN THE CALCULATIONS FOR THE FREE STANDING | | SIGNS SUBMITTED. ENGINEER TO REVISE INFORMATION AS | | REQUIRED TO MATCH | | SEC. 1603.1.4 FBC-BUILDING, SEC. 1609.1 FBC-BUILDING. | | | | 2- DIGITAL SIGNATURE: ENGINEER'S DIGITAL SIGNATURE | | DOESN'T COMPLY WITH THE REQUIREMENTS OF FBPE. | | | | A) THE TEXT BOX LANGUAGE MUST NOT BE A PART OF THE | | DIGITAL SIGNATURE ITSELF. | | SEE FBPE.ORG/LEGAL/SIGNING-AND-SEALING-ENGINEERING-DOCU | | MENTS/ AND REVISE AS REQUIRED. | | | | B) THE TEXT BOX LANGUAGE MUST BE IDENTICAL TO THE | | SAMPLES PUBLISHED BY FBPE. SEE FBPE.ORG/LEGAL/SIGNING-A | | ND-SEALING-ENGINEERING-DOCUMENTS/ AND REVISE AS | | REQUIRED TO MATCH. | | | | 61G15-23.004 PROCEDURES FOR DIGITALLY SIGNING AND | | SEALING ELECTRONICALLY TRANSMITTED PLANS, | | SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS. | | | | NOTE: | | THESE COMMENTS WERE VERIFIED WITH THE FBPE | | INVESTIGATOR. THE TEXT BOX REQUIREMENTS APPLY | | | | | | WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE | | ORIGINAL REVIEW COMMENT WITH A DESCRIPTION OF WHERE AND | | HOW THE COMMENT WAS ADDRESSED WILL HELP TO EXPEDITE THE | | REVIEW PROCESS. THANK YOU FOR YOUR ANTICIPATED | | COOPERATION. | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | QUESTIONS REGARDING THESE COMMENTS, | | | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
F |
Date |
2023-05-16 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2023-05-16 |
Time |
10:38 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2023-05-16 |
Time |
10:02 |
Sent To |
|
|
Notes |
2023-05-16 10:41:27 | FIFTH BUILDING REVIEW COMMENTS | | CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS. | | PERMIT #22120578 | | 6200 S DIXIE HWY | | | | | | PREVIOUS COMMENT: | | 1-ENGINEER TO PROVIDE COMPLETE DETAIL/SPECIFICATIONS | | FOR CONSTRUCTION AND ATTACHMENT OF ALL THE ALUMINUM | | FACES AND LETTERS SHOWN ON DRAWING SUBMITTED. SPECIFY | | ALL FRAMING MEMBERS AND FASTENERS. SEC. 1609.1 | | FBC-BUILDING. | | | | PROPOSED SIGN IS COMPLETELY DIFFERENT THAN EXISTING | | ONE. THIS IS NOT A REPLACEMENT. SEE EXISTING SIGN AND | | PROPOSED SIGN. ENGINEER TO PROVIDE COMPLETE | | DETAIL/SPECIFICATIONS FOR CONSTRUCTION AND ATTACHMENT | | OF SIGNS. | | | | PREVIOUS RESPONSE: | | A)ENGINEER STILL DOESN'T PROVIDE COMPLETE | | DETAILS/SPECIFICATIONS FOR THE INSTALLATION OF THE NEW | | SIGN ON THE EXISTING POSTS. | | B)ENGINEER TO SIGN AND SEAL ALL DRAWINGS SHOWING THE | | PROPOSED SIGN. NOTE: INCLUDING EXISTING AND PROPOSED | | SIGN DRAWING. | | C)ENGINEER TO REVISE THE WIND LOAD CALCULATIONS. SIZE | | OF PROPOSED SIGN DOESN'T MATCH SIZE SHOWN ON PLANS | | SUBMITTED. | | | | | | NEW RESPONSE: | | A)ENGINEER TO UPDATE CODES & SPECIFICATIONS | | INFORMATION. THE CURRENT CODE IS 2020 FBC AND THE | | CURRENT ASCE7 IS ASCE 7-16 NOT ASCE 7-10. | | SEC. 553.73 F.S. | | | | B) SUBMIT EACH DRAWING INDIVIDUALLY. | | | | C) ALL DRAWINGS TO BE SIGNED AND SEALED BY THE ENGINEER | | OF RECORD. | | CHAPTER 471 F.S. | | NOTE: PLEASE DON'T UPLOAD ANY DRAWING TO THE SIGNATURE | | FOLDER. UPLOAD ONLY IN THE DRAWINGS FOLDER. | | | | WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE | | ORIGINAL REVIEW COMMENT WITH A DESCRIPTION OF WHERE AND | | HOW THE COMMENT WAS ADDRESSED WILL HELP TO EXPEDITE THE | | REVIEW PROCESS. THANK YOU FOR YOUR ANTICIPATED | | COOPERATION. | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | QUESTIONS REGARDING THESE COMMENTS, | | | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
F |
Date |
2023-04-19 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2023-04-20 |
Time |
18:44 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2023-04-19 |
Time |
17:29 |
Sent To |
|
|
Notes |
2023-04-19 18:46:34 | FOURTH BUILDING REVIEW COMMENTS | | CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS. | | PERMIT #22120578 | | 6200 S DIXIE HWY | | | | | | PREVIOUS COMMENT: | | 1-ENGINEER TO PROVIDE COMPLETE DETAIL/SPECIFICATIONS | | FOR CONSTRUCTION AND ATTACHMENT OF ALL THE ALUMINUM | | FACES AND LETTERS SHOWN ON DRAWING SUBMITTED. SPECIFY | | ALL FRAMING MEMBERS AND FASTENERS. SEC. 1609.1 | | FBC-BUILDING. | | | | PROPOSED SIGN IS COMPLETELY DIFFERENT THAN EXISTING | | ONE. THIS IS NOT A REPLACEMENT. SEE EXISTING SIGN AND | | PROPOSED SIGN. ENGINEER TO PROVIDE COMPLETE | | DETAIL/SPECIFICATIONS FOR CONSTRUCTION AND ATTACHMENT | | OF SIGNS. | | | | RESPONSE: | | A)ENGINEER STILL DOESN'T PROVIDE COMPLETE | | DETAILS/SPECIFICATIONS FOR THE INSTALLATION OF THE NEW | | SIGN ON THE EXISTING POSTS. | | B)ENGINEER TO SIGN AND SEAL ALL DRAWINGS SHOWING THE | | PROPOSED SIGN. NOTE: INCLUDING EXISTING AND PROPOSED | | SIGN DRAWING. | | C)ENGINEER TO REVISE THE WIND LOAD CALCULATIONS. SIZE | | OF PROPOSED SIGN DOESN'T MATCH SIZE SHOWN ON PLANS | | SUBMITTED. | | | | WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE | | ORIGINAL REVIEW COMMENT WITH A DESCRIPTION OF WHERE AND | | HOW THE COMMENT WAS ADDRESSED WILL HELP TO EXPEDITE THE | | REVIEW PROCESS. THANK YOU FOR YOUR ANTICIPATED | | COOPERATION. | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | QUESTIONS REGARDING THESE COMMENTS, | | | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] | | | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2023-03-02 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2023-03-02 |
Time |
17:25 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2023-03-02 |
Time |
17:19 |
Sent To |
|
|
Notes |
2023-03-02 17:29:53 | THIRD BUILDING REVIEW COMMENTS | | CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS. | | PERMIT #22120578 | | 6200 S DIXIE HWY | | | | | | ARCHITECTS-ENGINEERS | | FLORIDA STATUTE 553.80(2)(B): | | ARCHITECTS WITH RESPECT TO EVALUATION OF DESIGN | | PROFESSIONALS DOCUMENTS, IF A LOCAL GOVERNMENT FINDS IT | | NECESSARY, IN ORDER TO ENFORCE COMPLIANCE WITH THE | | FLORIDA BUILDING CODE AND ISSUE A PERMIT, TO REJECT | | DESIGN DOCUMENTS REQUIRED BY THE CODE THREE OR MORE | | TIMES FOR FAILURE TO CORRECT A CODE VIOLATION | | SPECIFICALLY AND CONTINUOUSLY NOTED IN EACH REJECTION, | | INCLUDING, BUT NOT LIMITED TO, EGRESS, FIRE PROTECTION, | | STRUCTURAL STABILITY, ENERGY, ACCESSIBILITY, LIGHTING, | | VENTILATION, ELECTRICAL, MECHANICAL, PLUMBING, AND GAS | | SYSTEMS, OR OTHER REQUIREMENTS IDENTIFIED BY RULE OF | | THE FLORIDA BUILDING COMMISSION ADOPTED PURSUANT TO | | CHAPTER 120, THE LOCAL GOVERNMENT SHALL IMPOSE, EACH | | TIME AFTER THE THIRD SUCH REVIEW THE PLANS ARE REJECTED | | FOR THAT CODE VIOLATION, A FEE OF FOUR TIMES THE AMOUNT | | OF THE PROPORTION OF THE PERMIT FEE ATTRIBUTED TO PLANS | | REVIEW | | | | PREVIOUS COMMENT: | | 1-ENGINEER TO PROVIDE COMPLETE DETAIL/SPECIFICATIONS | | FOR CONSTRUCTION AND ATTACHMENT OF ALL THE ALUMINUM | | FACES AND LETTERS SHOWN ON DRAWING SUBMITTED. SPECIFY | | ALL FRAMING MEMBERS AND FASTENERS. SEC. 1609.1 | | FBC-BUILDING. | | | | RESPONSE: | | PROPOSED SIGN IS COMPLETELY DIFFERENT THAN EXISTING | | ONE. THIS IS NOT A REPLACEMENT. ENGINEER TO SHOW | | EXISTING SIGN AND PROPOSED SIGN. ENGINEER TO PROVIDE | | COMPLETE DETAIL/SPECIFICATIONS FOR CONSTRUCTION AND | | ATTACHMENT OF SIGNS. | | NOTE: 4X PLAN REVIEW FEES WILL APPLY FOR FUTURE | | SUBMITTALS. SEE FLORIDA STATUTE 553.80(2)(B) ABOVE. | | | | ENGINEER OF RECORD TO PROVIDE A SIGNED AND SEALED | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | WITH A DESCRIPTION OF WHERE AND HOW THE COMMENT WAS | | ADDRESSED TO AVOID 4X PLAN REVIEW FEES PER FLORIDA | | STATUTE 553.80(2)(B) ABOVE. PLEASE FEEL FREE TO CONTACT | | ME IF YOU HAVE ANY QUESTIONS REGARDING THESE COMMENTS, | | | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2023-02-23 |
|
|
Cont ID |
|
Sent By |
lbond |
Date |
2023-02-23 |
Time |
13:58 |
Rev Time |
0.00 |
Received By |
lbond |
Date |
2023-02-23 |
Time |
13:31 |
Sent To |
|
|
Notes |
2023-02-23 14:00:26 | PREVIOUS COMMENTS NOT ADDRESSED-DETAILS, ATTACHEMENTS | | OF ALL NEW SIGN ELEMENTS. | | CONTACT INFO: | | | | LOUIS BOND, AIA | | BUILDING PLANS EXAMINER II | | DEVELOPMENT SERVICES DEPT. | | BUILDING DIVISION | | 401 CLEMATIS STREET | | WEST PALM BEACH, FLORIDA 33401 | | PH: 561-805-6729 | | FX: 561-805-6676 | | EMAIL: [email protected] | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2023-01-13 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2023-01-13 |
Time |
14:11 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2023-01-13 |
Time |
13:51 |
Sent To |
|
|
Notes |
2023-01-13 14:59:36 | BUILDING REVIEW COMMENTS | | CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS. | | PERMIT #22120578 | | 6200 S DIXIE HWY | | | | 1-ENGINEER TO PROVIDE COMPLETE DETAIL/SPECIFICATIONS | | FOR CONSTRUCTION AND ATTACHMENT OF ALL THE ALUMINUM | | FACES AND LETTERS SHOWN ON DRAWING SUBMITTED. SPECIFY | | ALL FRAMING MEMBERS AND FASTENERS. SEC. 1609.1 | | FBC-BUILDING. | | | | WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE | | ORIGINAL REVIEW COMMENT WITH A DESCRIPTION OF WHERE AND | | HOW THE COMMENT WAS ADDRESSED WILL HELP TO EXPEDITE THE | | REVIEW PROCESS. THANK YOU FOR YOUR ANTICIPATED | | COOPERATION. | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | QUESTIONS REGARDING THESE COMMENTS, | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
6 |
Status |
P |
Date |
2023-07-10 |
|
|
Cont ID |
|
Sent By |
mpeterso |
Date |
2023-07-10 |
Time |
08:52 |
Rev Time |
0.00 |
Received By |
mpeterso |
Date |
2023-07-10 |
Time |
08:50 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
5 |
Status |
P |
Date |
2023-06-14 |
|
|
Cont ID |
|
Sent By |
mpeterso |
Date |
2023-06-14 |
Time |
09:12 |
Rev Time |
0.00 |
Received By |
mpeterso |
Date |
2023-06-14 |
Time |
09:11 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
P |
Date |
2023-04-19 |
|
|
Cont ID |
|
Sent By |
mpeterso |
Date |
2023-04-19 |
Time |
09:58 |
Rev Time |
0.00 |
Received By |
mpeterso |
Date |
2023-04-19 |
Time |
09:58 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2023-03-13 |
|
|
Cont ID |
|
Sent By |
mpeterso |
Date |
2023-03-13 |
Time |
08:03 |
Rev Time |
0.00 |
Received By |
mpeterso |
Date |
2023-03-13 |
Time |
08:00 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2023-02-21 |
|
|
Cont ID |
|
Sent By |
mpeterso |
Date |
2023-02-21 |
Time |
10:53 |
Rev Time |
0.00 |
Received By |
mpeterso |
Date |
2023-02-21 |
Time |
10:50 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2022-12-30 |
|
|
Cont ID |
|
Sent By |
mpeterso |
Date |
2022-12-30 |
Time |
13:28 |
Rev Time |
0.00 |
Received By |
mpeterso |
Date |
2022-12-30 |
Time |
13:21 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
7 |
Status |
N |
Date |
2023-07-11 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2023-07-11 |
Time |
09:43 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2023-06-28 |
Time |
08:10 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2023-06-16 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2023-06-16 |
Time |
14:29 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2023-06-05 |
Time |
09:05 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2023-05-16 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2023-05-16 |
Time |
10:41 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2023-05-16 |
Time |
10:02 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2023-04-19 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2023-04-19 |
Time |
18:49 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2023-04-11 |
Time |
10:30 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2023-03-13 |
|
|
Cont ID |
|
Sent By |
mpeterso |
Date |
2023-03-13 |
Time |
08:04 |
Rev Time |
0.00 |
Received By |
mpeterso |
Date |
2023-02-27 |
Time |
08:45 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2023-02-23 |
|
|
Cont ID |
|
Sent By |
lbond |
Date |
2023-02-23 |
Time |
14:01 |
Rev Time |
0.00 |
Received By |
lbond |
Date |
2023-02-13 |
Time |
16:56 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2023-01-13 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2023-01-13 |
Time |
14:11 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2022-12-14 |
Time |
11:37 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
6 |
Status |
P |
Date |
2023-07-11 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2023-07-11 |
Time |
09:42 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2023-07-11 |
Time |
09:42 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
5 |
Status |
F |
Date |
2023-06-16 |
|
|
Cont ID |
|
Sent By |
mpeterso |
Date |
2023-06-14 |
Time |
09:15 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2023-06-14 |
Time |
09:15 |
Sent To |
|
|
Notes |
2023-06-16 14:39:27 | 1- DIGITAL SIGNATURE: ENGINEER'S DIGITAL SIGNATURE | | DOESN'T COMPLY WITH THE REQUIREMENTS OF FBPE. | | | | A) THE TEXT BOX LANGUAGE MUST NOT BE A PART OF THE | | DIGITAL SIGNATURE ITSELF. | | SEE FBPE.ORG/LEGAL/SIGNING-AND-SEALING-ENGINEERING-DOCU | | MENTS/ AND REVISE AS REQUIRED. | | | | B) THE TEXT BOX LANGUAGE MUST BE IDENTICAL TO THE | | SAMPLES PUBLISHED BY FBPE. SEE FBPE.ORG/LEGAL/SIGNING-A | | ND-SEALING-ENGINEERING-DOCUMENTS/ AND REVISE AS | | REQUIRED TO MATCH. | | | | 61G15-23.004 PROCEDURES FOR DIGITALLY SIGNING AND | | SEALING ELECTRONICALLY TRANSMITTED PLANS, | | SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS. | | | | NOTE: | | THESE COMMENTS WERE VERIFIED WITH THE FBPE | | INVESTIGATOR. THE TEXT BOX REQUIREMENTS APPLY | | | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
4 |
Status |
P |
Date |
2023-04-19 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2023-04-19 |
Time |
18:49 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2023-04-19 |
Time |
18:46 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
3 |
Status |
P |
Date |
2023-03-13 |
|
|
Cont ID |
|
Sent By |
mpeterso |
Date |
2023-03-13 |
Time |
08:04 |
Rev Time |
0.00 |
Received By |
mpeterso |
Date |
2023-03-13 |
Time |
08:03 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2023-02-21 |
|
|
Cont ID |
|
Sent By |
mpeterso |
Date |
2023-02-21 |
Time |
10:55 |
Rev Time |
0.00 |
Received By |
mpeterso |
Date |
2023-02-21 |
Time |
10:53 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
P |
Date |
2022-12-30 |
|
|
Cont ID |
|
Sent By |
mpeterso |
Date |
2022-12-30 |
Time |
13:28 |
Rev Time |
0.00 |
Received By |
mpeterso |
Date |
2022-12-30 |
Time |
13:28 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
6 |
Status |
P |
Date |
2023-07-05 |
|
|
Cont ID |
|
Sent By |
vbroglia |
Date |
2023-07-05 |
Time |
11:58 |
Rev Time |
0.00 |
Received By |
vbroglia |
Date |
2023-07-05 |
Time |
11:58 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
5 |
Status |
P |
Date |
2023-06-14 |
|
|
Cont ID |
|
Sent By |
vbroglia |
Date |
2023-06-14 |
Time |
09:32 |
Rev Time |
0.00 |
Received By |
vbroglia |
Date |
2023-06-14 |
Time |
09:32 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
4 |
Status |
F |
Date |
2023-04-17 |
|
|
Cont ID |
|
Sent By |
vbroglia |
Date |
2023-04-17 |
Time |
16:17 |
Rev Time |
0.00 |
Received By |
vbroglia |
Date |
2023-04-17 |
Time |
16:17 |
Sent To |
|
|
Notes |
2023-04-17 16:20:21 | SIGN IS WITHIN THE VISIBILITY TRIANGLE, PER THE ZONING | | CODE: | | | | | | AT ANY ROAD INTERSECTIONS, VISIBILITY SHALL NOT BE | | OBSCURED BY THE CONSTRUCTION, PLACEMENT, OR MAINTENANCE | | OF A STRUCTURE WALL, SIGN, FENCE, BERM, PLANT MATERIAL, | | SHRUBS, OR ANY SIMILAR ITEM BETWEEN 18 INCHES OR EIGHT | | FEET IN HEIGHT WITHIN A TRIANGLE BEGINNING AT THE POINT | | WHERE PROPERTY LINES MEET AT THE CORNER, THEN 20 FEET | | ALONG THE FRONT PROPERTY LINE, THENCE DIAGONALLY TO A | | POINT ALONG THE SIDE PROPERTY LINE 20 FEET FROM THE | | POINT OF BEGINNING, AND THENCE TO THE POINT OF | | BEGINNING. IN THE EVENT THE CORNER OF AN INTERSECTION | | IS ROUNDED, THE MEASUREMENT SHALL BEGIN AT THE POINT | | THE PROPERTY LINES WOULD MEET WITHOUT ROUNDING. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
F |
Date |
2023-03-09 |
|
|
Cont ID |
|
Sent By |
vbroglia |
Date |
2023-03-09 |
Time |
10:20 |
Rev Time |
0.00 |
Received By |
vbroglia |
Date |
2023-03-09 |
Time |
10:20 |
Sent To |
|
|
Notes |
2023-03-09 10:19:55 | 3/9/2023 FAILED | | | | 1. A SURVEY IS REQUIRED | | | | 2. PLEASE SHOW THE SIGN DISTANCE FROM THE RIGHT-OF-WAY | | | | 3. PLEASE SHOW THE MEASUREMENTS OF HOW FAR THE SIGN IS | | FROM THE ADJACENT PARKING SPOT, MUST SHOW THERE IS ROOM | | TO OPEN A DOOR | | | | 4. PLEASE VISIBILITY AT INTERSECTION, PE RTHE ZONING | | CODE: | | | | AT ANY ROAD INTERSECTIONS, VISIBILITY SHALL NOT BE | | OBSCURED BY THE CONSTRUCTION, PLACEMENT, OR MAINTENANCE | | OF A STRUCTURE WALL, SIGN, FENCE, BERM, PLANT MATERIAL, | | SHRUBS, OR ANY SIMILAR ITEM BETWEEN 18 INCHES OR EIGHT | | FEET IN HEIGHT WITHIN A TRIANGLE BEGINNING AT THE POINT | | WHERE PROPERTY LINES MEET AT THE CORNER, THEN 20 FEET | | ALONG THE FRONT PROPERTY LINE, THENCE DIAGONALLY TO A | | POINT ALONG THE SIDE PROPERTY LINE 20 FEET FROM THE | | POINT OF BEGINNING, AND THENCE TO THE POINT OF | | BEGINNING. IN THE EVENT THE CORNER OF AN INTERSECTION | | IS ROUNDED, THE MEASUREMENT SHALL BEGIN AT THE POINT | | THE PROPERTY LINES WOULD MEET WITHOUT ROUNDING. | | | | 5. IF PROPOSED SIGN IS NOT WITHIN THE VISIBILTY | | TRIANGLE, A LANDSCAPE BUFFER AND CURB CUT IS | | RECOMMENDED BY STAFF. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2023-02-22 |
|
|
Cont ID |
|
Sent By |
vbroglia |
Date |
2023-02-22 |
Time |
11:54 |
Rev Time |
0.00 |
Received By |
vbroglia |
Date |
2023-02-22 |
Time |
11:54 |
Sent To |
|
|
Notes |
2023-02-22 11:55:50 | 2/22/23 FAILED | | | | PLEASE SHOW THE SETBACKS | | | | SEE PREVIOUS COMMENT FOR SETBACKS REQUIERED | | | | **** REVIEWD BY **** | | VALENTINA BROGLIA | | PLANNER | | [email protected] | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2022-12-29 |
|
|
Cont ID |
|
Sent By |
vbroglia |
Date |
2022-12-29 |
Time |
14:46 |
Rev Time |
0.00 |
Received By |
vbroglia |
Date |
2022-12-29 |
Time |
14:34 |
Sent To |
|
|
Notes |
2022-12-29 14:39:06 | 12/29/2022 FAILED | | | | PLEASE SHOW THE SETBACKS OF THE PROPOSED LOCATION OF | | THE LOW FREE STANDING SIGN | | HIEGHT PERMITTED IS 10 FEET, PLEASE REDUCE HIEGHT TO | | MEET REQUIRMENTS | | SEE ZONING CODE SECTION 94-408(2) | | | | LOW FREESTANDING SIGNS. THE REQUIREMENTS FOR LOW | | FREESTANDING SIGNS SHALL BE AS FOLLOWS: | | A.CONTENT: THE NAME, LOGO, AND ADDRESS OF THE BUILDING | | AND BUILDING OCCUPANTS TO WHICH THE SIGN IS ACCESSORY | | AND OTHER RELATED INFORMATION IN ADDITION, SIGNS | | PERMITTED PURSUANT TO THIS SECTION MAY CONTAIN ANY | | NONCOMMERCIAL MESSAGE WHICH HAS NOT BEEN DECLARED BY A | | COURT OF COMPETENT JURISDICTION TO BE OBSCENE, | | DEFAMATORY, OR OTHERWISE CONTRARY TO LAW. | | B.MAXIMUM SUM TOTAL AREA OF ALL LOW FREESTANDING SIGNS | | ON FRONT STREET: ONE SQUARE FOOT FOR EACH ONE LINEAR | | FOOT OF FRONT STREET FRONTAGE OF THE LOTS ON WHICH | | LOCATED. | | C.MAXIMUM SUM TOTAL AREA OF ALL LOW FREESTANDING SIGNS | | ON SIDE STREET FRONTAGE: 0.50 SQUARE FEET FOR EACH ONE | | LINEAR FOOT OF FRONT STREET FRONTAGE OF THE LOTS ON | | WHICH LOCATED. | | D.MAXIMUM NUMBER OF ALL LOW FREESTANDING SIGNS ON EACH | | LOT: ONE SIGN FOR EACH INDIVIDUAL BUSINESS OCCUPANT ON | | THE LOT TO A MAXIMUM OF THREE SIGNS. | | | | E.MINIMUM SETBACKS: | | 1.FROM LOT LINE OF ANOTHER LOT: 24 FEET. | | 2.FROM PUBLIC RIGHT-OF-WAY LINE: FIVE FEET. | | 3.FROM INTERSECTIONS OF STREETS WITH OTHER STREETS AND | | WITH ACCESS DRIVES: AS REQUIRED BY SUBSECTION | | 94-305(E). | | 4.MAXIMUM HEIGHT: TEN FEET. | | | | **** REVIEWD BY **** | | VALENTINA BROGLIA | | ASSOCIATE PLANNER | | [email protected] | | |
|
|