Plan Review Stops For Permit 22120545 |
Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
Rev No |
1 |
Status |
P |
Date |
2022-12-21 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2022-12-21 |
Time |
15:38 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2022-12-21 |
Time |
15:33 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2023-01-24 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2023-01-24 |
Time |
07:41 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2023-01-24 |
Time |
07:14 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2022-12-21 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2022-12-21 |
Time |
15:39 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2022-12-21 |
Time |
15:33 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2023-01-25 |
|
|
Cont ID |
|
Sent By |
mpeterso |
Date |
2023-01-25 |
Time |
09:25 |
Rev Time |
0.00 |
Received By |
mpeterso |
Date |
2023-01-25 |
Time |
09:25 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2022-12-28 |
|
|
Cont ID |
|
Sent By |
mpeterso |
Date |
2022-12-28 |
Time |
13:49 |
Rev Time |
0.00 |
Received By |
mpeterso |
Date |
2022-12-28 |
Time |
13:45 |
Sent To |
|
|
Notes |
2022-12-28 13:58:23 | ELECTRIC REVIEW FAILED | | 1) ELECTRIC PANEL LOCATION DOES NOT COMPLY WITH NEC | | 110.26 CLEARANCES | | 2) ELECTRIC PLAN INDICATES VARIOUS ELECTRICAL | | RECEPTACLES, PLEASE INDICATE WHETHER THESE ARE | | EXISTING, NEW, MODIFIED OR REPLACED. FBC 107.2 | | 3) PLEASE DETAIL NEW KITCHEN LIGHTS AND OTHER WIRING TO | | BE ARC FAULT PROTECTED. NEC 210.12 | | 4) PLEASE PROVIDE A PANEL SCHEDULE INDICATING ALL THE | | REQUIRED CIRCUITS AS PER NEC 210.11 | | 5) VALUE FOR WORK STATED ON PERMIT APPLICATION APPEARS | | LOW. PROVIDE A BREAKDOWN OF ALL MATERIALS AND LABOR, | | OR, AT YOUR DISCRETION, PROVIDE A SIGNED CONTRACTOR | | PROVIDE A REASONABLE VALUE. WPB F.B.C. 109.3 | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. | | | | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | BUILDING CODE 2020 7TH ED. | | FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020 | | 7TH EDITION | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | 7TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION | | NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | V/R, | | | | MICHAEL PETERSON | | ELECTRICAL PLANS EXAMINER | | [email protected] | | 561-805-6746 | | | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2023-01-19 |
|
|
Cont ID |
|
Sent By |
cwalker |
Date |
2023-01-19 |
Time |
|
Rev Time |
0.00 |
Received By |
cwalker |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2022-12-14 |
|
|
Cont ID |
|
Sent By |
cwalker |
Date |
2022-12-14 |
Time |
|
Rev Time |
|
Received By |
cwalker |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2023-01-25 |
|
|
Cont ID |
|
Sent By |
mpeterso |
Date |
2023-01-25 |
Time |
09:35 |
Rev Time |
0.00 |
Received By |
mpeterso |
Date |
2023-01-18 |
Time |
08:30 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2022-12-28 |
|
|
Cont ID |
|
Sent By |
mpeterso |
Date |
2022-12-28 |
Time |
13:58 |
Rev Time |
0.00 |
Received By |
mpeterso |
Date |
2022-12-13 |
Time |
08:07 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
N |
Date |
2022-12-21 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2022-12-21 |
Time |
15:39 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2022-12-21 |
Time |
15:33 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2023-01-19 |
|
|
Cont ID |
|
Sent By |
rwbrown |
Date |
2023-01-19 |
Time |
14:59 |
Rev Time |
0.00 |
Received By |
rwbrown |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2022-12-20 |
|
|
Cont ID |
|
Sent By |
rwbrown |
Date |
2022-12-20 |
Time |
14:25 |
Rev Time |
|
Received By |
rwbrown |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2023-01-19 |
|
|
Cont ID |
|
Sent By |
mpeterso |
Date |
2023-01-19 |
Time |
11:01 |
Rev Time |
0.00 |
Received By |
mpeterso |
Date |
2023-01-19 |
Time |
10:59 |
Sent To |
|
|
Notes |
2023-01-19 11:02:27 | 1/19/23 SIGNATURE REVIEW OF PAPER PLANS/DOCUMENTS | | PASSED AND ROUTED TO STORAGE.MP |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
P |
Date |
2022-12-13 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2022-12-13 |
Time |
14:50 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2022-12-13 |
Time |
14:50 |
Sent To |
|
|
Notes |
2022-12-13 14:51:31 | SIGNED AND SEALED DRAWINGS SENT TO STORAGE. |
|
|