Plan Review Details - Permit 22120529
Plan Review Stops For Permit 22120529
Review Stop AD ADDRESSING
Rev No 3 Status P Date 2023-04-12 Cont ID  
Sent By cpuell Date 2023-04-12 Time 12:41 Rev Time 0.00
Received By cpuell Date 2023-04-12 Time 12:41 Sent To  
Notes
2023-04-12 12:43:06ZONING IS NOT ALLOWING A SECOND UNIT, NO SECONDARY
 ADDRESS CAN BE GIVEN TO THE BUILDING.

Review Stop AD ADDRESSING
Rev No 2 Status F Date 2023-02-14 Cont ID  
Sent By cpuell Date 2023-02-14 Time 14:13 Rev Time 0.00
Received By cpuell Date 2023-02-14 Time 14:13 Sent To  
Notes
2023-02-14 14:13:33WHAT YOU ARE CALLING A GUEST UNIT IS CURRENT DESIGNATED
 AS A GARAGE, A SECONDARY ADDRESS MAY NEED TO BE
 ASSIGNED IF ZONING APPROVES A SECONDARY UNIT. PLEASE
 CONTACT [email protected] OR CALL 561-805-6659 ONCE
 ZONING APPROVES THEIR REVIEW.

Review Stop AD ADDRESSING
Rev No 1 Status F Date 2023-01-05 Cont ID  
Sent By cpuell Date 2023-01-05 Time 11:00 Rev Time 0.00
Received By cpuell Date 2023-01-05 Time 11:00 Sent To  
Notes
2023-01-05 11:01:17WHAT YOU ARE CALLING A GUEST UNIT IS CURRENT DESIGNATED
 AS A GARAGE, A SECONDARY ADDRESS MAY NEED TO BE
 ASSIGNED IF ZONING APPROVES A SECONDARY UNIT. PLEASE
 CONTACT [email protected] OR CALL 561-805-6659 ONCE
 ZONING APPROVES THEIR REVIEW.

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2023-04-04 Cont ID  
Sent By cthroop Date 2023-04-04 Time 15:37 Rev Time 0.00
Received By cthroop Date 2023-04-04 Time 11:07 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2023-03-07 Cont ID  
Sent By cthroop Date 2023-03-07 Time 12:33 Rev Time 0.00
Received By cthroop Date 2023-03-03 Time 15:23 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2023-01-27 Cont ID  
Sent By cthroop Date 2023-01-27 Time 09:51 Rev Time 0.00
Received By cthroop Date 2023-01-27 Time 08:59 Sent To  
Notes
2023-01-27 09:58:031ST BUILDING REVIEW
 RESULTS: CORRECTIONS NEEDED
  
 CHRISTOPHER S. THROOP, CBO, BN, PX, CFM
 PLANS EXAMINER II
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 NFPA 70 2017 EDITION NEC 2017
  
 ADDRESS THE FOLLOWING COMMENTS AND RE-SUBMIT:
  
 1. PROVIDE AN EXISTING FLOOR PLAN.
 107.2 CONSTRUCTION DOCUMENTS SHALL BE IN ACCORDANCE
 WITH SECTIONS107.2.1 THROUGH 107.2.5.
  
 2.IDENTIFY THE CEILING AND WALL INSULATION TYPE AND
 R-VALUE ON PLANS.
 107.2 CONSTRUCTION DOCUMENTS SHALL BE IN ACCORDANCE
 WITH SECTIONS107.2.1 THROUGH 107.2.5.
  
 3. PROVIDE CURRENT PRODUCT APPROVALS OR NOA FOR
 PROPOSED EXTERIOR DOOR.
 PRODUCT APPROVALS INCLUDE THE COVER SHEET, EVALUATION
 REPORT AND INSTALLATION INSTRUCTIONS.
 FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
 WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2023-04-03 Cont ID  
Sent By rperdomo Date 2023-04-03 Time 14:27 Rev Time 0.00
Received By rperdomo Date 2023-04-03 Time 13:06 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2023-02-15 Cont ID  
Sent By rperdomo Date 2023-02-15 Time 16:11 Rev Time 0.00
Received By rperdomo Date 2023-02-15 Time 16:06 Sent To  
Notes
2023-02-15 16:11:04FLORIDA BUILDING CODE 2020 7TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED
 NFPA 70 2017 EDITION
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW
  
 1. PROVIDE DISCONNECTING MEANS FOR A/C EQUIPMENT PER
 NEC 440.14 OR IRC E4101.5
 DISCONNECTING MEANS IS REQUIRED TO BE LOCATED ???WITHIN
 SIGHT FROM AND READILY ACCESSIBLE??? FROM THE
 AIR-CONDITIONING EQUIPMENT.
  
 2. SERVICE RECEPTACLE PER NEC 210.63 OR IRC E3901.11
 THE RECEPTACLE MUST BE IN A READILY ACCESSIBLE LOCATION
 FROM THE EQUIPMENT AND MUST BE GFCI-PROTECTED AS
 APPLICABLE TO OUTDOOR RECEPTACLES AT DWELLING
 OCCUPANCIES
  
 END OF COMMENTS
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
 RUBEN PEREZ PERDOMO, P.E.
 ELECTRICAL PLANS EXAMINER
 561-805-6738
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2023-01-04 Cont ID  
Sent By rperdomo Date 2023-01-04 Time 10:39 Rev Time 0.00
Received By rperdomo Date 2023-01-04 Time 09:21 Sent To  
Notes
2023-01-04 10:39:11FLORIDA BUILDING CODE 2020 7TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED
 NFPA 70 2017 EDITION
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW
  
 1. PROVIDE INFORMATION OF MAIN ELECTRICAL PANEL LOAD
 CALCULATION FOR SERVICE, INCLUDE EXISTING AND NEW LOADS
 TO CONFIRM CAPACITY OF SERVICE IS ADEQUATE.
 NEC 215.2, 220.
  
 2. PROVIDE DISCONNECTING MEANS FOR A/C EQUIPMENT PER
 NEC 440.14 OR IRC E4101.5
 DISCONNECTING MEANS IS REQUIRED TO BE LOCATED ???WITHIN
 SIGHT FROM AND READILY ACCESSIBLE??? FROM THE
 AIR-CONDITIONING EQUIPMENT.
  
 3. SERVICE RECEPTACLE PER NEC 210.63 OR IRC E3901.11
 THE RECEPTACLE MUST BE IN A READILY ACCESSIBLE LOCATION
 FROM THE EQUIPMENT AND MUST BE GFCI-PROTECTED AS
 APPLICABLE TO OUTDOOR RECEPTACLES AT DWELLING
 OCCUPANCIES.
  
 4. PROVIDE A SINGLE-LINE DIAGRAM SHOWING THE ELECTRICAL
 PANELS (MAIN PANEL AND SUBPANELS), FEEDERS SIZES,
 PROTECTION, AND GROUNDING.
  
 END OF COMMENTS
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
 RUBEN PEREZ PERDOMO, P.E.
 ELECTRICAL PLANS EXAMINER
 561-805-6738
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2023-04-04 Cont ID  
Sent By cthroop Date 2023-04-04 Time 15:39 Rev Time 0.00
Received By cthroop Date 2023-03-30 Time 10:37 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2023-03-07 Cont ID  
Sent By cthroop Date 2023-03-07 Time 12:38 Rev Time 0.00
Received By cthroop Date 2023-02-14 Time 08:17 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2023-01-27 Cont ID  
Sent By cthroop Date 2023-01-27 Time 09:58 Rev Time 0.00
Received By cthroop Date 2023-01-03 Time 09:40 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 3 Status P Date 2023-04-13 Cont ID  
Sent By lmarchan Date 2023-04-13 Time 15:45 Rev Time 0.00
Received By lmarchan Date 2023-04-12 Time 15:22 Sent To  
Notes
2023-04-13 15:45:51NO IMPACT FEES DUE. LEM
2023-04-12 15:22:534/12/23 EMAILED IMPACT OFFICE TO REVIEW. LEM

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status F Date 2023-03-07 Cont ID  
Sent By cthroop Date 2023-03-07 Time 12:37 Rev Time 0.00
Received By cthroop Date 2023-03-07 Time 12:37 Sent To  
Notes
2023-03-07 12:38:25NEW PLAN PAGE G-02 REQUIRED. CT

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2023-01-27 Cont ID  
Sent By cthroop Date 2023-01-27 Time 09:40 Rev Time 0.00
Received By cthroop Date 2023-01-27 Time 08:58 Sent To  
Notes
2023-01-27 09:40:44IMPACT FEES
 PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECT DOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON
 APPROVAL AND FEE PAYMENT (IF ANY), PLEASE UPLOAD THE
 RECEIPT TO YOUR PROJECT OR EMAIL IT TO
 [email protected] .
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2023-01-05 Cont ID  
Sent By medwards Date 2023-01-05 Time 10:34 Rev Time 0.00
Received By medwards Date 2023-01-05 Time 10:34 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2023-03-01 Cont ID  
Sent By rwbrown Date 2023-03-01 Time 14:04 Rev Time 0.00
Received By rwbrown Date 2023-03-21 Time 13:59 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2023-01-06 Cont ID  
Sent By rwbrown Date 2023-01-06 Time 05:30 Rev Time 0.00
Received By rwbrown Date 2023-01-06 Time 05:30 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status N Date 2023-04-04 Cont ID  
Sent By cthroop Date 2023-04-04 Time 15:38 Rev Time 0.00
Received By cthroop Date 2023-04-04 Time 11:07 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status N Date 2023-03-07 Cont ID  
Sent By cthroop Date 2023-03-07 Time 12:33 Rev Time 0.00
Received By cthroop Date 2023-03-03 Time 15:23 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status N Date 2023-01-27 Cont ID  
Sent By cthroop Date 2023-01-27 Time 09:51 Rev Time 0.00
Received By cthroop Date 2023-01-27 Time 08:59 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 4 Status P Date 2023-04-04 Cont ID  
Sent By asangele Date 2023-04-04 Time 14:42 Rev Time 0.00
Received By asangele Date 2023-04-04 Time 14:42 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 3 Status P Date 2023-03-21 Cont ID  
Sent By asangele Date 2023-03-21 Time 11:01 Rev Time 0.00
Received By asangele Date 2023-03-21 Time 11:01 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status F Date 2023-02-28 Cont ID  
Sent By asangele Date 2023-02-28 Time 13:23 Rev Time 0.00
Received By asangele Date 2023-02-28 Time 13:23 Sent To  
Notes
2023-03-07 10:32:01FAILED
 MARCH 7,2023
  
  
 A 220 VOLT OUTLET FOR A STOVE CANNOT BE INSTALLED IN
 THE ACCESSORY STRUCTURE BECAUSE YOU ARE NOT ALLOWED A
 SECOND UNIT ON YOUR PROPERTY.
  
  
 ALEXIS SANGELEER
 PLANNER
 [email protected]

Review Stop Z ZONING
Rev No 1 Status F Date 2023-01-20 Cont ID  
Sent By ASangele Date 2023-01-20 Time 12:10 Rev Time 0.00
Received By asangele Date 2023-01-20 Time 12:10 Sent To  
Notes
2023-01-20 12:14:22FAILED
 1/20/2023
  
  
 A 220 VOLT OUTLET FOR A STOVE CANNOT BE INSTALLED IN
 THE ACCESSORY STRUCTURE BECAUSE YOU ARE NOT ALLOWED A
 SECOND UNIT ON YOUR PROPERTY.
  
  
 ALEXIS SANGELEER
 PLANNER
 [email protected]