Plan Review Details - Permit 22120245
Plan Review Stops For Permit 22120245 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2023-04-11 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2023-04-11 |
Time |
09:03 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2023-04-11 |
Time |
08:54 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2023-02-03 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2023-02-03 |
Time |
13:55 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2023-02-03 |
Time |
13:44 |
Sent To |
|
|
Notes |
2023-02-03 14:07:09 | PETER E VALENTI | | BUILDING PLANS EXAMINER II/INSPECTOR | | [email protected] | | 561 805 6673 | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | FBC B = FBC BUILDING | | FBC R = FBC RESIDENTIAL | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC M = FBC MECHANICAL | | FBC FG = FBC FUEL GAS | | | | BUILDING REVIEW DENIED: | | | | 1.) CITY OF WPB AMENDMENTS TO FBC B FIGURE 1609.3(1), | | THE WINDLOADS THAT ARE INDICATED WITHIN THE ENGINEER'S | | LETTER SHOW AN ULT DESIGN WIND SPEED OF 164 MPH. THIS | | NEEDS TO BE CHANGED TO 170 MPH (ULT). | | | | 2.) NOTICE: THE PLAN SHEETS AND ENGINEERING LETTERS | | NEED TO HAVE 3RD PARTY VERIFIABLE SIGNATURES BY DESIGN | | PROFESSIONALS. | | A. DOCUMENTS PREPARED BY AN ARCHITECT OR ENGINEER AND | | SUBMITTED ELECTRONICALLY FOR PUBLIC RECORD SHALL HAVE A | | VALID DIGITAL SIGNATURE. A SCAN OF A WET SEAL AND | | SIGNATURE OR DIGITAL SIGNATURE IS NOT CONSIDERED A | | VALID DIGITAL SIGNATURE. | | ALL ELECTRONIC DOCUMENTS PREPARED BY ARCHITECTS OR | | ENGINEERS MUST BE DIGITALLY SIGNED, IN ACCORDANCE WITH | | 61G1-16 AND 61G15, F.A.C. | | B. SUBMIT PLANS WITH A VALID DIGITAL SIGNATURE. | | FBC 107.2.1 ALL INFORMATION, DRAWINGS, SPECIFICATIONS | | AND ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE | | OF THE PERSON RESPONSIBLE FOR THE DESIGN. (SEE ALSO | | SECTION 107.3.5), CHPT. 471, F.S. & 61G15 AND CHPT. | | 481, F.S. & 61G1. | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2023-04-11 |
|
|
Cont ID |
|
Sent By |
mpeterso |
Date |
2023-04-11 |
Time |
11:31 |
Rev Time |
0.00 |
Received By |
mpeterso |
Date |
2023-04-11 |
Time |
11:28 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2023-01-26 |
|
|
Cont ID |
|
Sent By |
mpeterso |
Date |
2023-01-26 |
Time |
11:43 |
Rev Time |
0.00 |
Received By |
mpeterso |
Date |
2023-01-26 |
Time |
11:31 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2023-04-11 |
|
|
Cont ID |
|
Sent By |
mpeterso |
Date |
2023-04-11 |
Time |
11:31 |
Rev Time |
0.00 |
Received By |
mpeterso |
Date |
2023-04-03 |
Time |
11:43 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2023-02-03 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2023-02-03 |
Time |
14:07 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2023-01-12 |
Time |
11:41 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2023-04-11 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2023-04-11 |
Time |
09:03 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2023-04-11 |
Time |
08:54 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2023-01-26 |
|
|
Cont ID |
|
Sent By |
mpeterso |
Date |
2023-01-26 |
Time |
11:44 |
Rev Time |
0.00 |
Received By |
mpeterso |
Date |
2023-01-26 |
Time |
11:44 |
Sent To |
|
|
Notes |
2023-01-26 11:51:11 | SIGNATURE REVIEW FAILED | | 1) ALL PLANS AND LETTER DETAIL AN ENGINEERS DIGITAL | | SIGNATURE STAMP, HOWEVER. BLUEBEAM AND ADOBE SOFTWARE | | DO NOT INDICATE A DIGITAL SIGNATURE OR CERTIFICATION OF | | DIGITAL SIGNATURE BY A THIRD-PARTY AGENCY . PLEASE | | CORRECT AS OUTLINED BELOW. | | | | FS471/FS481 DOCUMENTS PREPARED BY ARCHITECT/ENGINEER OF | | RECORD AND SUBMITTED FOR PUBLIC RECORD ARE TO BE | | DIGITALLY SEALED AND SIGNED. | | | | PLEASE SUBMIT DIGITALLY SEALED AND SIGNED PLANS | | FOLLOWING PROJECTDOX INSTRUCTIONS | | | | MICHAEL PETERSON | | ELECTRICAL PLANS EXAMINER | | [email protected] | | 561-805-6746 | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2023-04-06 |
|
|
Cont ID |
|
Sent By |
vbroglia |
Date |
2023-04-06 |
Time |
15:16 |
Rev Time |
0.00 |
Received By |
vbroglia |
Date |
2023-04-06 |
Time |
15:16 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2023-01-20 |
|
|
Cont ID |
|
Sent By |
VBroglia |
Date |
2023-01-20 |
Time |
12:28 |
Rev Time |
0.00 |
Received By |
vbroglia |
Date |
2023-01-20 |
Time |
12:28 |
Sent To |
|
|
Notes |
|
|
|