Plan Review Details - Permit 22111003
Plan Review Stops For Permit 22111003
Review Stop AD ADDRESSING
Rev No 1 Status P Date 2022-11-28 Cont ID  
Sent By shill Date 2022-11-28 Time 07:03 Rev Time 0.00
Received By shill Date 2022-11-28 Time 07:03 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2023-03-17 Cont ID  
Sent By rmcphers Date 2023-03-17 Time 09:04 Rev Time 0.00
Received By rmcphers Date 2023-03-17 Time 09:04 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2023-03-03 Cont ID  
Sent By rmcphers Date 2023-03-03 Time 10:24 Rev Time 0.00
Received By rmcphers Date 2023-03-03 Time 10:11 Sent To  
Notes
2023-03-03 10:20:49DOORS
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
  
 1) DOOR (B146) IS IN WIND ZONE 5 PER DRAWING S0.06
 WHICH SHOWS A WIND PRESSURE OF (-176 X .6 = 105.6) -
 PRODUCT APPROVAL NUMBER (20-0310.08) CONFIGURATION 1
 SHOWS A PRESSURE OF (-75) (+75) - WHICH DOES NOT MEET
 THE REQUIRED WIND PRESSURE.
  
 2) PLEASE PROVIDE THE FRONT PAGES OF THE STATE PRODUCT
 APPROVAL FOR (FL16355.1)
  
 3) THE ORIGINAL SIGNED AND SEALED PRIVATE PROVIDER
 AFFIDAVIT NEEDS TO BE DELIVERED TO THE BUILDING
 DIVISION.

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2023-01-31 Cont ID  
Sent By pleduc Date 2023-01-31 Time   Rev Time 0.00
Received By pleduc Date 2023-01-31 Time 10:42 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2023-03-17 Cont ID  
Sent By rmcphers Date 2023-03-17 Time 09:04 Rev Time 0.00
Received By rmcphers Date 2023-03-16 Time 15:39 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2023-03-03 Cont ID  
Sent By rmcphers Date 2023-03-03 Time 10:34 Rev Time 0.00
Received By rmcphers Date 2023-01-10 Time 08:15 Sent To  
Notes
***NONE***

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 2 Status P Date 2023-03-17 Cont ID  
Sent By rmcphers Date 2023-03-17 Time 09:04 Rev Time 0.00
Received By rmcphers Date 2023-03-17 Time 09:04 Sent To  
Notes
***NONE***

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 1 Status P Date 2023-03-03 Cont ID  
Sent By rmcphers Date 2023-03-03 Time 10:31 Rev Time 0.00
Received By rmcphers Date 2023-03-03 Time 10:31 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2023-03-20 Cont ID  
Sent By jgomez Date 2023-03-20 Time 16:10 Rev Time 0.00
Received By jgomez Date 2023-03-20 Time 16:09 Sent To  
Notes
2023-03-20 16:11:57PRIVATE PROVIDER PLAN COMPLIANCE AFFIDAVIT WITH WET
 SIGNATURE DATED 3/15/23. JG.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status N Date 2023-03-03 Cont ID  
Sent By rmcphers Date 2023-03-03 Time 10:32 Rev Time 0.00
Received By rmcphers Date 2023-03-03 Time 10:32 Sent To  
Notes
2023-03-03 10:34:15THE ORIGINAL SIGNED AND SEALED PRIVATE PROVIDER
 AFFIDAVIT NEEDS TO BE DELIVERED TO THE BUILDING
 DIVISION.


Account Summary | Usage Policy | Privacy Policy