Plan Review Stops For Permit 22110889 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
P |
Date |
2023-05-23 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2023-05-23 |
Time |
09:32 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2023-05-23 |
Time |
09:21 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
F |
Date |
2023-04-08 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2023-04-08 |
Time |
08:40 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2023-04-08 |
Time |
08:40 |
Sent To |
|
|
Notes |
2023-04-08 08:44:37 | APPROVAL OF THE BUILDING REVIEW IS PENDING APPROVAL OF | | THE SIGNATURE REVIEW. CT |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2023-03-01 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2023-03-01 |
Time |
13:55 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2023-03-01 |
Time |
13:55 |
Sent To |
|
|
Notes |
2023-03-01 13:57:56 | ****CORRECTIONS**** | | | | ROBERT MCDOUGAL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6714 | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC R = FBC RESIDENTIAL | | | | 1. NOT RESOLVED. FBC R 301 IT IS NOT CLEAR WHICH | | GENERATOR IS PROPOSED. UNTIL THAT INFORMATION IS | | PROVIDED, THE GENERATOR PAD ENGINEERING CANNOT BE | | REVIEWED, FBC 107. | | | | 2. NOT RESOLVED. FS 471, PLEASE UPLOAD DIGITALLY SIGNED | | ENGINEERING FOR THE GENERATOR PAD. THE DOCUMENT HAS THE | | IMAGE OF A DIGITAL SIGNATURE BUT THE DIGITAL SIGNATURE | | CERTIFICATE WAS REMOVED FROM THE DOCUMENT BEFORE | | UPLOADING. | | | | | | | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2023-01-14 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2023-01-14 |
Time |
13:47 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2023-01-14 |
Time |
13:47 |
Sent To |
|
|
Notes |
2023-01-14 13:48:34 | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC R = FBC RESIDENTIAL | | | | 1. FBC R 301 IT IS NOT CLEAR WHICH GENERATOR IS | | PROPOSED. UNTIL THAT INFORMATION IS PROVIDED, THE | | GENERATOR PAD ENGINEERING CANNOT BE REVIEWED, FBC 107. | | | | 2. FS 471, PLEASE UPLOAD DIGITALLY SIGNED ENGINEERING | | FOR THE GENERATOR PAD. THE DOCUMENT HAS THE IMAGE OF A | | DIGITAL SIGNATURE BUT THE DIGITAL SIGNATURE CERTIFICATE | | WAS REMOVED FROM THE DOCUMENT BEFORE UPLOADING. YOU MAY | | EMAIL THE ENGINEERING TO [email protected], | | [email protected] FOR PRELIMINARY REVIEW. | | | | | | | | | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2022-12-29 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2022-12-29 |
Time |
15:52 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2022-12-29 |
Time |
15:52 |
Sent To |
|
|
Notes |
2022-12-29 16:06:32 | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC R = FBC RESIDENTIAL | | | | 1. FBC R 301 PROVIDE A STRUCTURAL DETAIL FOR THE | | GENERATOR PAD, INCLUDING WIND DESIGN CRITERIA AND | | ANCHORING TO RESIST SPECIFIED WIND LOADS. | | | | 2. FBC R 303.5.1, OUTDOOR AIR INTAKE OPENINGS SHALL BE | | LOCATED NOT LESS THAN 10 FEET (3048 MM) FROM ANY | | HAZARDOUS OR NOXIOUS CONTAMINANT. REVISE PLAN TO SHOW | | DISTANCE FROM GENERATOR EXHAUST TO CLOSEST OPENING. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2023-02-10 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2023-02-10 |
Time |
18:33 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2023-02-10 |
Time |
17:57 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2023-01-16 |
|
|
Cont ID |
|
Sent By |
fgiaquin |
Date |
2023-01-16 |
Time |
23:26 |
Rev Time |
0.00 |
Received By |
fgiaquin |
Date |
2023-01-16 |
Time |
22:56 |
Sent To |
|
|
Notes |
2023-01-16 22:59:21 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | 1. PROVIDE CUT SHEETS OF TRANSFER SWITCH AND GENERATOR | | FBC 107.2.1 NEC 110.3B | | | | 2. WHAT IS WHAT IS GENERATOR OUTPUT OCP SIZE? FBC | | 107.2.1 | | | | 3. **** PREVIOUS COMMENT SATISFIED. (PLAN IS NOW | | SIGNED) | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | PREVIOUSLY REVIEWED SHEETS. | | CODES IN EFFECT: | | | | HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B | | UILDING-PERMIT-FORMS | | | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | BUILDING CODE 2020 7TH ED. | | FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020 | | 7TH EDITION | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | 7TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION | | NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | V/R, | | | | FRANK GIAQUINTO III | | ELECTRICAL INSPECTOR | | ELECTRICAL PLANS EXAMINER | | CITY OF WEST PALM BEACH | | [email protected] | | CELL: 561-805-6744 | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2022-12-10 |
|
|
Cont ID |
|
Sent By |
fgiaquin |
Date |
2022-12-10 |
Time |
20:42 |
Rev Time |
0.00 |
Received By |
fgiaquin |
Date |
2022-12-10 |
Time |
20:07 |
Sent To |
|
|
Notes |
2022-12-10 20:42:22 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | 1. PROVIDE CUT SHEETS OF TRANSFER SWITCH AND GENERATOR | | FBC 107.2.1 NEC 110.3B | | | | 2. WHAT IS WHAT IS GENERATOR OUTPUT OCP SIZE? FBC | | 107.2.1 | | | | 3. ELECTRICAL PLAN IS REQUIRED TO BE SIGNED BY THE | | ELECTRICAL CONTRACTOR QUALIFIER. PROVIDE CORRECTION. FS | | 471.003(2)(H); 471.025; WPB FBC 107.1 | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | PREVIOUSLY REVIEWED SHEETS. | | CODES IN EFFECT: | | | | HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B | | UILDING-PERMIT-FORMS | | | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | BUILDING CODE 2020 7TH ED. | | FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020 | | 7TH EDITION | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | 7TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION | | NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | V/R, | | | | FRANK GIAQUINTO III | | ELECTRICAL INSPECTOR | | ELECTRICAL PLANS EXAMINER | | CITY OF WEST PALM BEACH | | [email protected] | | CELL: 561-805-6744 | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2023-05-23 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2023-05-23 |
Time |
09:33 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2023-05-04 |
Time |
09:11 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2023-04-17 |
|
|
Cont ID |
|
Sent By |
asangele |
Date |
2023-04-17 |
Time |
15:02 |
Rev Time |
0.00 |
Received By |
asangele |
Date |
2023-04-17 |
Time |
15:02 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2023-03-01 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2023-03-01 |
Time |
13:58 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2023-02-07 |
Time |
11:34 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2023-01-16 |
|
|
Cont ID |
|
Sent By |
fgiaquin |
Date |
2023-01-16 |
Time |
23:26 |
Rev Time |
0.00 |
Received By |
fgiaquin |
Date |
2023-01-09 |
Time |
16:09 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2022-12-29 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2022-12-29 |
Time |
16:06 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2022-11-22 |
Time |
08:31 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
5 |
Status |
P |
Date |
2023-05-23 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2023-05-23 |
Time |
09:33 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2023-05-23 |
Time |
09:21 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
4 |
Status |
F |
Date |
2023-04-08 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2023-04-08 |
Time |
08:40 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2023-04-08 |
Time |
08:40 |
Sent To |
|
|
Notes |
2023-04-08 08:43:56 | 4TH SIGNATURE REVIEW | | RESULTS: CORRECTIONS NEEDED | | | | CHRISTOPHER S. THROOP, CBO, BN, PX, CFM | | PLANS EXAMINER II | | CITY OF WEST PALM BEACH | | (561) 805-6726 | | [email protected] | | | | CODES IN EFFECT: | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | NFPA 70 2017 EDITION NEC 2017 | | | | ADDRESS THE FOLLOWING COMMENTS AND RE-SUBMIT: | | | | NOTICE: PLAN PAGE CONCRETE GEN PAD REQUIRES VALID | | DIGITAL SIGNATURE OF ENGINEER. | | | | 1.DOCUMENTS PREPARED BY AN ARCHITECT OR ENGINEER AND | | SUBMITTED ELECTRONICALLY FOR PUBLIC RECORD SHALL HAVE A | | VALID DIGITAL SIGNATURE. | | A SCAN OF A WET SEAL AND SIGNATURE OR DIGITAL SIGNATURE | | IS NOT CONSIDERED A VALID DIGITAL SIGNATURE. | | | | 2.SUBMIT PLANS WITH A VALID DIGITAL SIGNATURE PER F.S. | | 668.003 (3); | | FBC 107.2.1 ALL INFORMATION, DRAWINGS, SPECIFICATIONS | | AND ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE | | OF THE PERSON RESPONSIBLE FOR THE DESIGN. (SEE ALSO | | SECTION 107.3.5). | | F.S. 471; F.A.C. 61G15-23.005 (ENGINEERS) | | F.S. 481; F.A.C. 61G1-16.005 (ARCHITECTS) | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
3 |
Status |
F |
Date |
2023-03-01 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2023-03-01 |
Time |
13:52 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2023-03-01 |
Time |
13:52 |
Sent To |
|
|
Notes |
2023-03-01 13:54:39 | THE ENGINEER'S DIGITAL SIGNATURE ON THE GENERATOR PAD | | ENGINEERING COULD NOT BE VERIFIED. ELECTRONICALLY | | SUBMITTED DRAWINGS ARE REQUIRED TO HAVE THE ARCHITECT | | OR ENGINEER'S DIGITAL SIGNATURE ON THEM. FS 481 & FAC | | 61G1 OR FS 471 & FAC 61G15 |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
F |
Date |
2023-01-14 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2023-01-14 |
Time |
13:48 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2023-01-14 |
Time |
13:48 |
Sent To |
|
|
Notes |
2023-01-14 13:49:31 | SEE BULDING REVIEW | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
N |
Date |
2022-12-30 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2022-12-30 |
Time |
09:22 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2022-12-30 |
Time |
09:22 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2023-04-17 |
|
|
Cont ID |
|
Sent By |
asangele |
Date |
2023-04-17 |
Time |
15:01 |
Rev Time |
0.00 |
Received By |
asangele |
Date |
2023-04-17 |
Time |
15:01 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2023-01-13 |
|
|
Cont ID |
|
Sent By |
asangele |
Date |
2023-01-13 |
Time |
14:38 |
Rev Time |
0.00 |
Received By |
asangele |
Date |
2023-01-13 |
Time |
14:38 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2022-12-07 |
|
|
Cont ID |
|
Sent By |
asangele |
Date |
2022-12-07 |
Time |
14:22 |
Rev Time |
0.00 |
Received By |
asangele |
Date |
2022-12-07 |
Time |
14:22 |
Sent To |
|
|
Notes |
|
|