Plan Review Stops For Permit 22110873 |
Review Stop |
AD |
ADDRESSING |
Rev No |
1 |
Status |
P |
Date |
2022-12-13 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2022-12-13 |
Time |
16:15 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2022-12-13 |
Time |
16:15 |
Sent To |
|
|
Notes |
2022-12-13 16:15:38 | ADDRESS APPROPRIATE FOR PROJECT. |
|
|
Review Stop |
AIPP |
ART IN PUBLIC PLACES |
Rev No |
3 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2023-03-27 |
Time |
|
Rev Time |
0.00 |
Received By |
swelter |
Date |
2023-03-27 |
Time |
08:54 |
Sent To |
|
|
Notes |
|
|
Review Stop |
AIPP |
ART IN PUBLIC PLACES |
Rev No |
2 |
Status |
F |
Date |
2023-01-12 |
|
|
Cont ID |
|
Sent By |
swelter |
Date |
2023-01-12 |
Time |
12:01 |
Rev Time |
0.00 |
Received By |
swelter |
Date |
2023-01-12 |
Time |
12:03 |
Sent To |
|
|
Notes |
2023-01-12 12:03:27 | SUBJECT TO PUBLIC ART REQUIREMENT PLEASE CONTACT | | SYBILLE WELTER AT [email protected] | | | | |
|
|
Review Stop |
AIPP |
ART IN PUBLIC PLACES |
Rev No |
1 |
Status |
N |
Date |
2023-02-13 |
|
|
Cont ID |
|
Sent By |
swelter |
Date |
2023-02-13 |
Time |
13:41 |
Rev Time |
0.00 |
Received By |
swelter |
Date |
2023-02-13 |
Time |
13:41 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2023-05-19 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2023-05-19 |
Time |
12:59 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2023-05-19 |
Time |
12:59 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2023-03-06 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2023-03-06 |
Time |
15:40 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2023-03-06 |
Time |
14:57 |
Sent To |
|
|
Notes |
2023-03-06 15:38:24 | NEW 2 STORY OFFICE | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected] | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | AMENDMENT | | | | CORRECTIONS NEEDED - | | | | 1) IN THE PRODUCT APPROVAL PROVIDED FOR THE ROOFING | | SYSTEM - PLEASE CIRCLE THE ROOFING SYSTEM TO BE USED IN | | THE ROOFING PRODUCT APPROVAL - ROOFING SYSTEM TO BE | | USED ON THE PROVIDED PRODUCT APPROVAL MAY REQUIRE | | ADDITIONAL SIGNED AND SEALED ATTACHMENT DETAILS FROM AN | | ARCHITECT OR ENGINEER FOR ROOF WIND ZONES 2 AND 3 WHICH | | REQUIRE A HIGHER PRESSURE THAN THE MAXIMUM SHOWN ON THE | | PRODUCT APPROVAL - SEE GENERAL LIMITATION NOTES ON THE | | PRODUCT APPROVAL. | | | | 2) FRONT PAGE OF THE PRODUCT APPROVAL (FL16554) FOR THE | | WINDOW - "APPLICATION STATUS" SHOWS "PENDING FBC | | APPROVAL" - THE FRONT PAGE OF THE PRODUCT APPROVAL | | "APPLICATION STATUS" SHOULD SHOW "APPROVED". | | | | 3) DRAWINGS G-001, G-002, LS-101, LS - 102, ALL OF THE | | ARCHITECTURAL DRAWINGS DO NOT SHOW AS DIGITALLY SIGNED | | IN ADOBE READER - SIGNED AND SEALED DRAWINGS IN | | PROJECTDOX NEED TO BE DIGITALLY/ELECTRONICALLY SIGNED | | TO BE USED IN ELECTRONIC PLAN REVIEW. (A | | CERTIFICATE-BASED DIGITAL SIGNATURE (OFTEN JUST CALLED | | A DIGITAL SIGNATURE) IS A SPECIFIC TYPE OF | | E-SIGNATURE). | | | | | | | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2023-01-11 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2023-01-11 |
Time |
07:59 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2023-01-10 |
Time |
15:10 |
Sent To |
|
|
Notes |
2023-01-10 16:21:22 | NEW 2 STORY OFFICE | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected] | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | AMENDMENT | | | | CORRECTIONS NEEDED - | | | | 1) DRAWING G-001 AND LS-101 - BUILDING DATA SHOWS RISK | | CATEGORY III - DRAWING S-001 DESIGN CRITERIA SHOWS | | BUILDING RISK CATEGORY II - PLEASE CLARIFY - ALL | | DRAWINGS SHOULD MATCH. | | | | 2) SOME DRAWINGS SAY "NOT FOR CONSTRUCTION" CANNOT HAVE | | THAT NOTE ON THE DRAWINGS (LS101, LS102 PLEASE CHECK | | ALL). | | | | 3) PLEASE PROVIDE RAMP DETAIS - RAMP WIDTH, RAMP SLOPE, | | LANDING SIZE AT RAMP TURN, EDGE PROTECTION ETC. FBC A | | 405 | | | | 4) PLEASE PROVIDE COMPLETE (FRONT PAGES AND THE | | INSTALLATION INSTRUCTIONS) MIAMI DADE OR FLORIDA STATE | | PRODUCT APPROVALS FOR THE ROOFING SYSTEMS. | | | | 5) PLEASE PROVIDE THE FLORIDA STATE PRODUCT APPROVAL | | FRONT PAGE FOR (FL16554) WINDOW PRODUCT APPROVAL. | | | | 6) PLEASE SHOW THE BUILDING SETBACKS FROM THE PROPERTY | | LINES ON THE SITE PLAN. FBC WPB 107.2.5 | | | | 7) PLEASE SHOW THE ROOF SLOPE FBC 1507.6.2 | | | | 8) ACCESSIBLE RESTROOM - THE MAXIMUM DIMENSION FOR THE | | MIRROR FROM THE FLOOR TO THE BOTTOM OF THE REFLECTIVE | | SURFACE SHOULD BE 40 INCHES - FBC A 603.3 | | | | 9) BAY 1 AND BAY 2 EXPOSED INSULATION - FBC 720.3 | | EXPOSED INSTALLATION. | | INSULATING MATERIALS, WHERE EXPOSED AS INSTALLED IN | | BUILDINGS OF ANY TYPE OF CONSTRUCTION, SHALL HAVE A | | FLAME SPREAD INDEX OF NOT MORE THAN 25 AND A | | SMOKE-DEVELOPED INDEX OF NOT MORE THAN 450. | | | | 10) SEPARATE PERMITS ARE REQUIRED FOR - EXISTING | | BUILDING DEMO., FENCES, PARKING LOT. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2023-06-07 |
|
|
Cont ID |
|
Sent By |
rperdomo |
Date |
2023-06-07 |
Time |
15:05 |
Rev Time |
0.00 |
Received By |
rperdomo |
Date |
2023-06-07 |
Time |
14:41 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2023-03-20 |
|
|
Cont ID |
|
Sent By |
rperdomo |
Date |
2023-03-20 |
Time |
09:49 |
Rev Time |
0.00 |
Received By |
rperdomo |
Date |
2023-03-20 |
Time |
09:03 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2022-12-16 |
|
|
Cont ID |
|
Sent By |
rperdomo |
Date |
2022-12-16 |
Time |
16:28 |
Rev Time |
0.00 |
Received By |
rperdomo |
Date |
2022-12-16 |
Time |
15:53 |
Sent To |
|
|
Notes |
2022-12-16 16:28:23 | FLORIDA BUILDING CODE 2020 7TH EDITION | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED | | NFPA 70 2017 EDITION | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW | | | | 1. PROVIDE SUBMITTAL OF ATS, AND GENERATOR AS PER FBC | | 107.2.1 | | | | 2. PROVIDE AVAILABLE SHORT CIRCUIT CURRENT TO FULFILL | | WITH NEC 110.9, 110.10, & 110.24 | | | | END OF COMMENTS | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM. | | | | RUBEN PEREZ PERDOMO, P.E. | | ELECTRICAL PLANS EXAMINER | | 561-805-6738 | | |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
3 |
Status |
P |
Date |
2023-06-01 |
|
|
Cont ID |
|
Sent By |
lquinone |
Date |
2023-06-01 |
Time |
19:33 |
Rev Time |
0.00 |
Received By |
lquinone |
Date |
2023-06-01 |
Time |
19:33 |
Sent To |
|
|
Notes |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
2 |
Status |
F |
Date |
2023-03-06 |
|
|
Cont ID |
|
Sent By |
rrossano |
Date |
2023-03-06 |
Time |
|
Rev Time |
0.00 |
Received By |
rrossano |
Date |
2023-03-06 |
Time |
|
Sent To |
|
|
Notes |
2023-03-06 15:13:57 | A FORMAL ENGINEERING SUBMITTAL IS REQUIRED. |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
1 |
Status |
F |
Date |
2022-12-14 |
|
|
Cont ID |
|
Sent By |
rrossano |
Date |
2022-12-14 |
Time |
|
Rev Time |
|
Received By |
|
Date |
2022-12-14 |
Time |
|
Sent To |
|
|
Notes |
2022-12-14 11:50:32 | A FORMAL ENGINEERING SUBMITTAL IS REQUIRED. |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
P |
Date |
2023-05-19 |
|
|
Cont ID |
|
Sent By |
clfranci |
Date |
2023-05-19 |
Time |
|
Rev Time |
0.00 |
Received By |
clfranci |
Date |
2023-05-19 |
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2023-03-02 |
|
|
Cont ID |
|
Sent By |
clfranci |
Date |
2023-03-02 |
Time |
|
Rev Time |
0.00 |
Received By |
clfranci |
Date |
2023-03-02 |
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2022-12-12 |
|
|
Cont ID |
|
Sent By |
clfranci |
Date |
2022-12-12 |
Time |
|
Rev Time |
0.00 |
Received By |
clfranci |
Date |
2022-12-12 |
Time |
|
Sent To |
|
|
Notes |
2022-12-12 14:51:48 | THIS PLAN WAS REVIEWED AND FAILED BY CAITLIN L FRANCIS, | | FIRE INVESTIGATOR, WITH THE FOLLOWING COMMENTS: | | | | 1) THE TABLE ON THE LIFE SAFETY PLAN INDICATES THIS | | BUILDING BEING CLASSIFIED AS MIXED, SEPARATED OCCUPANCY | | BUT YOU HAVE LISTED 0-HOUR SEPARATION ON THE TABLE. | | PLEASE CLARIFY THIS WITH THE REFERENCE TO THE FOLLOWING | | ACCORDING TO NFPA 101 CHAPTER 6, | | 6.1.14.2.2 MIXED OCCUPANCY. A MULTIPLE OCCUPANCY WHERE | | THE OCCUPANCIES | | ARE INTERMINGLED. | | 6.1.14.2.3 SEPARATED OCCUPANCY. A MULTIPLE OCCUPANCY | | WHERE THE OCCUPANCIES ARE SEPARATED BY FIRE BARRIERS. | | | | 2) CLARIFY THE ALREADY LISTED SEPARATION WITH THE | | REQUIREMENTS OF TABLE 6.1.14.4.1. | | | | 3) THERE ARE WINDOWS SHOW ON FIRE RATED WALLS WITH NO | | RATING. PLEASE INDICATE THE RATING OF THE WINDOWS. | | | | 4) A LIFE SAFETY PLAN MUST CLEARLY ILLUSTRATE THE | | COMMON PATH OF TRAVEL AND TRAVEL DISTANCES, PER NFPA | | 101 CHAPTER 7. | | | | 5) A GATE IS INDICATED ON THE PLANS PLEASE INDICATE THE | | PROVIDED FIRE DEPARTMENT ACCESS. | | | | 6) ANY AND ALL WORK ON THE FIRE ALARM SYSTEM SHALL BE | | DONE BY A FIRE ALARM CONTRACTOR. A SEPARATE SHOP | | DRAWING COMPLIANT WITH NFPA 72 IS REQUIRED TO BE | | SUBMITTED, REVIEWED AND APPROVED BY THE FIRE PREVENTION | | BUREAU PRIOR TO ANY INSTALLATION. | | | | | | CAITLIN L FRANCIS | | FIRE INVESTIGATOR | | WEST PALM BEACH FIRE RESCUE | | 561-804-4728 | | [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2023-06-16 |
|
|
Cont ID |
|
Sent By |
vbroglia |
Date |
2023-06-16 |
Time |
13:26 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2023-05-18 |
Time |
17:38 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2023-03-21 |
|
|
Cont ID |
|
Sent By |
aoliver |
Date |
2023-03-21 |
Time |
09:06 |
Rev Time |
0.00 |
Received By |
aoliver |
Date |
2023-03-01 |
Time |
15:43 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2023-01-12 |
|
|
Cont ID |
|
Sent By |
aoliver |
Date |
2023-01-12 |
Time |
10:56 |
Rev Time |
0.00 |
Received By |
aoliver |
Date |
2022-12-09 |
Time |
09:49 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2023-01-11 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2023-01-11 |
Time |
07:33 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2023-01-11 |
Time |
07:33 |
Sent To |
|
|
Notes |
2023-01-11 07:34:35 | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF | | | | UPON APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE | | RECEIPT TO YOUR PROJECT OR EMAIL IT TO | | [email protected] . | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2023-06-16 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2023-06-16 |
Time |
13:26 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2023-06-16 |
Time |
12:53 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2023-03-10 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2023-03-10 |
Time |
07:30 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2023-03-09 |
Time |
16:05 |
Sent To |
|
|
Notes |
2023-03-09 16:08:20 | 1) THE OUTDOOR AIR CALCULATIONS FOR THE CONFERENCE ROOM | | SHALL BE CALCULATED BASED ON 29 OCCUPANTS. FMC | | 403.3.1.1 | | | | 2) THE MECHANICAL DOCUMENTS MUST BE SUBMITTED WITH THE | | DIGITAL SIGNATURE OF THE DESIGNER ON EACH SHEET. FS | | 471/481 | | | | MICHAEL EDWARDS | | MECHANICAL EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL. 33401 | | 561-805-6728 | | [email protected] | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2023-01-03 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2023-01-03 |
Time |
12:51 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2023-01-03 |
Time |
12:50 |
Sent To |
|
|
Notes |
2023-01-03 12:51:14 | 1ST REVIEW FMC | | PERMIT: 22110873 | | | | CODES IN EFFECT: 2020 | | | | FBC- FLORIDA BUILDING CODE | | FMC- FLORIDA MECHANICAL CODE | | FEC- FLORIDA ENERGY CONSERVATION | | FGC- FLORIDA FUEL GAS | | FEX- FLORIDA EXISTING BUILDING CODE | | FRC- FLORIDA RESIDENTIAL BUILDING CODE | | F.S.- FLORIDA STATUTES | | FAC- FLORIDA ACCESSIBILITY CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) PROVIDE THE ENERGY CALCULATIONS FOR THIS PROJECT. | | FEC C401.2 | | | | 2) PROVIDE THE MECHANICAL EQUIPMENT SIZING CALCULATIONS | | FOR THIS PROJECT. FEC C403.2.1 | | | | 3) SHEET LS-101; THE ELECTRICAL ROOM APPEARS TO HAVE 1 | | HOUR RATED WALLS. SHEET M-101: PROVIDE FIRE DAMPERS ON | | THE DRAWING FOR THE PENETRATIONS OF THE RATED WALLS | | WITH THE MECHANICAL DUCTWORK. | | | | 4) SHEET M-101: SHOW THAT EF-05 AND EF-06 MEET THE CFM | | REQUIREMENTS OF FMC TABLE 403.3.1.1 FOOTNOTE E | | | | 5) PROVIDE THE OUTDOOR AIR CALCULATIONS FOR THIS | | BUILDING. FMC 403.3.1.1 | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM. | | | | MICHAEL EDWARDS | | MECHANICAL EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL. 33401 | | 561-805-6728 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2023-05-22 |
|
|
Cont ID |
|
Sent By |
rwbrown |
Date |
2023-05-22 |
Time |
08:18 |
Rev Time |
0.00 |
Received By |
rwbrown |
Date |
2023-05-22 |
Time |
08:18 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2023-03-02 |
|
|
Cont ID |
|
Sent By |
rwbrown |
Date |
2023-03-02 |
Time |
13:46 |
Rev Time |
0.00 |
Received By |
rwbrown |
Date |
2023-03-02 |
Time |
13:46 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2023-01-04 |
|
|
Cont ID |
|
Sent By |
rwbrown |
Date |
2023-01-04 |
Time |
08:34 |
Rev Time |
0.00 |
Received By |
rwbrown |
Date |
2023-01-04 |
Time |
08:34 |
Sent To |
|
|
Notes |
2023-01-04 12:41:37 | 1ST PLUMBING REVIEW | | | | THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED | | BY RYAN BROWN WITH THE FOLLOWING COMMENTS. | | | | 1. PAGE P-101 -- 2020 FPC 914.1 - THE ISOMETRIC SHOWS | | THE UPSTAIRS GROUP'S STACK DISCHARGING TO THE HIGH SIDE | | OF THE CIRCUIT VENT THAT SERVES THE DOWNSTAIRS GROUP. A | | STACK CANNOT CONNECT TO THE CIRCUIT VENT. FIXTURES ARE | | ALLOW TO BE CIRCUIT VENTED WHEN CONNECTED TO A | | HORIZONTAL BRANCH DRAIN. THE CONNECTION OF A STACK AT | | THAT LOCATION TURNS THAT PORTION OF THE DRAIN INTO A | | BUILDING DRAIN. THE UPSTAIRS STACK WOULD NEED TO | | CONNECT DOWNSTREAM OF THE CIRCUIT VENT SYSTEM. | | | | 2. PAGE P-101 -- FD-2 - THE FLOOR DRAIN ON THE END OF | | THE RUN IS NOT VENTED. WHEN CONNECTED TO A BUIILDING | | DRAIN, IT NEEDS TO BE VENTED. | | | | 3. 2017 WPB AMENDS 107.3.5.1.3 - THE ROOF DRAINAGE | | APPEARS TO TERMINATE ONTO THE CANOPIES. I AM UNABLE TO | | LOCATE THE GUTTER/DOWNSPOUT SIZES FOR THE CANOPIES. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM. | | | | | | RYAN W. BROWN | | CHIEF PLUMBING INSPECTOR | | OFFICE: 561-805-6692 | | CELL: 561-517-4293 | | EMAIL: [email protected] | | | | | | V7 FPC - 2020 FLORIDA PLUMBING CODE | | V7 FGC - 2020 FLORIDA FUEL GAS | | V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE | | V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE | | V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE | | V7 FEC - 2020 FLORIDA ENERGY CONSERVATION | | 2021 F.S. - 2021 FLORIDA STATUTES | | 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE | | 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE | | FBC CHAPTER 1 | | |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
3 |
Status |
P |
Date |
2023-05-19 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2023-05-19 |
Time |
13:00 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2023-05-19 |
Time |
13:00 |
Sent To |
|
|
Notes |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
2 |
Status |
F |
Date |
2023-03-06 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2023-03-06 |
Time |
15:40 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2023-03-06 |
Time |
15:40 |
Sent To |
|
|
Notes |
2023-03-06 15:41:01 | SEE BUILDING PLAN REVIEW |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
F |
Date |
2023-01-11 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2023-01-11 |
Time |
07:34 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2023-01-11 |
Time |
07:34 |
Sent To |
|
|
Notes |
2023-01-11 07:35:19 | SEE BUILDING PLAN REVIEW |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
3 |
Status |
P |
Date |
2023-05-19 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2023-05-19 |
Time |
13:01 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2023-05-19 |
Time |
13:01 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
F |
Date |
2023-03-06 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2023-03-06 |
Time |
15:51 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2023-03-06 |
Time |
15:51 |
Sent To |
|
|
Notes |
2023-03-06 15:55:57 | SIGNATURE REVIEW | | | | CORRECTIONS NEEDED - | | | | 1) DRAWINGS G-001, G-002, LS-101, LS-102, ALL OF THE | | ARCHITECTURAL DRAWINGS, ALL OF THE PLUMBING DRAWINGS, | | ALL OF THE MECHANICAL DRAWINGS, AND ALL OF THE | | ELECTRICAL DRAWINGS DO NOT SHOW AS DIGITALLY SIGNED IN | | ADOBE READER - | | | | SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE | | DIGITALLY/ELECTRONICALLY SIGNED TO BE USED IN | | ELECTRONIC PLAN REVIEW. (A CERTIFICATE-BASED DIGITAL | | SIGNATURE (OFTEN JUST CALLED A DIGITAL SIGNATURE) IS A | | SPECIFIC TYPE OF E-SIGNATURE). | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
P |
Date |
2023-01-11 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2023-01-11 |
Time |
07:59 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2023-01-11 |
Time |
07:59 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2023-06-14 |
|
|
Cont ID |
|
Sent By |
vbroglia |
Date |
2023-06-14 |
Time |
09:16 |
Rev Time |
0.00 |
Received By |
vbroglia |
Date |
2023-06-14 |
Time |
09:16 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2023-03-06 |
|
|
Cont ID |
|
Sent By |
vbroglia |
Date |
2023-03-06 |
Time |
16:24 |
Rev Time |
0.00 |
Received By |
vbroglia |
Date |
2023-03-06 |
Time |
16:24 |
Sent To |
|
|
Notes |
2023-03-06 16:25:59 | SEPARATE PERMIT REQUIRED FOR: | | FENCE/WALL, AWNINGS, SIGNS, PARKING LOT, GENERATOR, | | MECHANICAL/AC/POOL EQUIPMENT, DUMPSTER ENCLOSURE, | | IRRIGATION, LANDSCAPE, OTHER. | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2022-12-19 |
|
|
Cont ID |
|
Sent By |
vbroglia |
Date |
2022-12-19 |
Time |
16:48 |
Rev Time |
0.00 |
Received By |
vbroglia |
Date |
2022-12-19 |
Time |
16:48 |
Sent To |
|
|
Notes |
|
|