Plan Review Stops For Permit 22110849 |
Review Stop |
AD |
ADDRESSING |
Rev No |
1 |
Status |
P |
Date |
2022-11-22 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2022-11-22 |
Time |
14:39 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2022-11-22 |
Time |
14:39 |
Sent To |
|
|
Notes |
2022-11-22 14:40:38 | PARCEL WAS READDRESSED FROM 506 DATURA T TO 510 DATURA | | STREET, 510DATURA ST TO REMAIN FOR THE PARCEL. THE | | SECONDARY ADDRESS OF 514 DATURA ST WILL BE RETIRED ONCE | | THE PERMIT IS CLOSED. |
|
|
Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
Rev No |
2 |
Status |
P |
Date |
2023-02-27 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2023-02-27 |
Time |
08:57 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2023-02-24 |
Time |
15:33 |
Sent To |
|
|
Notes |
|
|
Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
Rev No |
1 |
Status |
F |
Date |
2022-12-07 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2022-12-07 |
Time |
09:30 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2022-12-07 |
Time |
09:30 |
Sent To |
|
|
Notes |
2022-12-07 09:31:48 | ASBESTOS REVIEW: | | | | FAILED PLAN REVIEW, COMMERCIAL: | | | | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | CONTRACTOR, ON LETTERHEAD, STATING THAT THE | | INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM | | COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH | | COUNTY WILL BE FOLLOWED AND THAT NOTIFICATION WILL BE | | GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS | | REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE: | | | | HTTPS://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVIC | | ES/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION | | -RENOVATION.HTML | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2023-06-07 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2023-06-07 |
Time |
06:47 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2023-06-07 |
Time |
06:46 |
Sent To |
|
|
Notes |
2023-06-07 06:47:32 | PETER E VALENTI | | BUILDING PLANS EXAMINER II/INSPECTOR | | [email protected] | | 561 805 6673 | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | FBC B = FBC BUILDING | | FBC R = FBC RESIDENTIAL | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC M = FBC MECHANICAL | | FBC FG = FBC FUEL GAS | | | | THE FOLLOWING ITEMS ARE REQUIRED PRIOR TO ISSUANCE OF A | | DEMO PERMIT PER FLORIDA BUILDING | | CODE, BUILDING 3303: | | | | 1. UTILITY RELEASE - FLORIDA POWER & LIGHT (ELECTRIC) | | RELEASE OF SERVICE CONFIRMATION | | 3. WATERDOWN METHOD: | | IF A WATER TRUCK IS DESIRED, PROVIDE DETAILED | | INFPRMATION OF THE WATER TRUCK SUCH AS: THE | | GALLON CAPACITY OF THE WATER TANK AND A LETTER | | INCLUDING A STATEMENT THAT THE WATER | | USED WILL BE POTABLE AND FROM AN OFF-SITE LOCATION ONLY | | AND WILL BE ON-SITE AT ALL TIMES | | DURING DEMOLITION. | | IF A HYDRANT METER OR BACKFLOW PREVENTER IS DESIRED, | | THEN A PARTIAL RELEASE WILL BE NOTED | | ON THEIR FORM. IF THE BACKFLOW PREVENTER DEVICE IS | | SELECTED, A PLUMBING PERMIT IS REQUIRED. BEFORE | | SCHEDULING THE 703(PLUMBING FINAL INSPECTION), THE | | BACKFLOW DEVICE NEEDS TO BE TESTED AND CERTIFIED BY | | THE CITY???S UTILITIES DEPT, 561-822-2244. FAX THE | | COMPLETED "DEMOLITION APPLICATION" FORM TO | | 561-822-2183. | | 4. SEWER LATERAL CAPPING PERMIT IS REQUIRED (SUBMIT | | APPLICATION TO BUILDING DIVISION); | | SCHEDULE A FINAL PLUMBING #703. | | 5. EXTERMINATION LETTER - LETTER FROM A LICENSED PEST | | CONTROL COMPANY STATING THAT | | DEMOLITION ADDRESS HAS BEEN INSPECTED AND/OR TREATED | | FOR RODENTS. | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2023-02-27 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2023-02-27 |
Time |
08:57 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2023-02-24 |
Time |
15:33 |
Sent To |
|
|
Notes |
2023-02-27 09:00:16 | PETER E VALENTI | | BUILDING PLANS EXAMINER II/INSPECTOR | | [email protected] | | 561 805 6673 | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | FBC B = FBC BUILDING | | FBC R = FBC RESIDENTIAL | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC M = FBC MECHANICAL | | FBC FG = FBC FUEL GAS | | | | THE FOLLOWING ITEMS ARE REQUIRED PRIOR TO ISSUANCE OF A | | DEMO PERMIT PER FLORIDA BUILDING | | CODE, BUILDING 3303: | | | | 1. UTILITY RELEASE - FLORIDA POWER & LIGHT (ELECTRIC) | | RELEASE OF SERVICE CONFIRMATION | | 3. UTILITY RELEASE - CITY OF WEST PALM BEACH WATER | | DEPARTMENT, REQUEST FOR METER PULL, ON | | THEIR FORM "DEMOLITION APPLICATION" | | HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B | | UILDING-PERMIT-FORMS | | WATERDOWN METHOD: | | IF A WATER TRUCK IS DESIRED, PROVIDE DETAILED | | INFPRMATION OF THE WATER TRUCK SUCH AS: THE | | GALLON CAPACITY OF THE WATER TANK AND A LETTER | | INCLUDING A STATEMENT THAT THE WATER | | USED WILL BE POTABLE AND FROM AN OFF-SITE LOCATION ONLY | | AND WILL BE ON-SITE AT ALL TIMES | | DURING DEMOLITION. | | IF A HYDRANT METER OR BACKFLOW PREVENTER IS DESIRED, | | THEN A PARTIAL RELEASE WILL BE NOTED | | ON THEIR FORM. IF THE BACKFLOW PREVENTER DEVICE IS | | SELECTED, A PLUMBING PERMIT IS REQUIRED. BEFORE | | SCHEDULING THE 703(PLUMBING FINAL INSPECTION), THE | | BACKFLOW DEVICE NEEDS TO BE TESTED AND CERTIFIED BY | | THE CITY???S UTILITIES DEPT, 561-822-2244. FAX THE | | COMPLETED "DEMOLITION APPLICATION" FORM TO | | 561-822-2183. | | 4. SEWER LATERAL CAPPING PERMIT IS REQUIRED (SUBMIT | | APPLICATION TO BUILDING DIVISION); | | SCHEDULE A FINAL PLUMBING #703. | | 5. EXTERMINATION LETTER - LETTER FROM A LICENSED PEST | | CONTROL COMPANY STATING THAT | | DEMOLITION ADDRESS HAS BEEN INSPECTED AND/OR TREATED | | FOR RODENTS. | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2022-12-07 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2022-12-07 |
Time |
09:32 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2022-12-07 |
Time |
09:32 |
Sent To |
|
|
Notes |
2022-12-07 09:32:42 | THE FOLLOWING ITEMS ARE REQUIRED PRIOR TO ISSUANCE OF A | | DEMO PERMIT PER FLORIDA BUILDING | | CODE, BUILDING 3303: | | | | 1. UTILITY RELEASE - FLORIDA POWER & LIGHT (ELECTRIC) | | RELEASE OF SERVICE CONFIRMATION | | 2. UTILITY RELEASE - FLORIDA PUBLIC UTILITIES (GAS) | | RELEASE OF SERVICE CONFIRMATION | | 3. UTILITY RELEASE - CITY OF WEST PALM BEACH WATER | | DEPARTMENT, REQUEST FOR METER PULL, ON | | THEIR FORM "DEMOLITION APPLICATION" | | HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B | | UILDING-PERMIT-FORMS | | WATERDOWN METHOD: | | IF A WATER TRUCK IS DESIRED, PROVIDE DETAILED | | INFPRMATION OF THE WATER TRUCK SUCH AS: THE | | GALLON CAPACITY OF THE WATER TANK AND A LETTER | | INCLUDING A STATEMENT THAT THE WATER | | USED WILL BE POTABLE AND FROM AN OFF-SITE LOCATION ONLY | | AND WILL BE ON-SITE AT ALL TIMES | | DURING DEMOLITION. | | IF A HYDRANT METER OR BACKFLOW PREVENTER IS DESIRED, | | THEN A PARTIAL RELEASE WILL BE NOTED | | ON THEIR FORM. IF THE BACKFLOW PREVENTER DEVICE IS | | SELECTED, A PLUMBING PERMIT IS REQUIRED. BEFORE | | SCHEDULING THE 703(PLUMBING FINAL INSPECTION), THE | | BACKFLOW DEVICE NEEDS TO BE TESTED AND CERTIFIED BY | | THE CITY???S UTILITIES DEPT, 561-822-2244. FAX THE | | COMPLETED "DEMOLITION APPLICATION" FORM TO | | 561-822-2183. | | 4. SEWER LATERAL CAPPING PERMIT IS REQUIRED (SUBMIT | | APPLICATION TO BUILDING DIVISION); | | SCHEDULE A FINAL PLUMBING #703. | | 5. EXTERMINATION LETTER - LETTER FROM A LICENSED PEST | | CONTROL COMPANY STATING THAT | | DEMOLITION ADDRESS HAS BEEN INSPECTED AND/OR TREATED | | FOR RODENTS. | | 6. COMPLETE THE DEMO DEBRIS FORM: HTTP://WPB.ORG/DEPART | | MENTS/DEVELOPMENT-SERVICES/FORMS/BUILDING-PERMIT-FORMS | | IF THE FORM IS NOT AVAILABLE ONLINE, SEND A REQUEST FOR | | THE FORM TO [email protected]. | | 7. PROVIDE A SITE PLAN OR SURVEY SHOWING LOCATION OF | | THE STRUCTURE(S) TO BE DEMOLISHED, | | FBC 107. | | 8. PROVIDE A STORMWATER POLLUTION PREVENTION PLAN. | | 9. PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | CONTRACTOR, ON LETTERHEAD, STATING THAT THE | | INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM | | COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH | | COUNTY WILL BE FOLLOWED AND THAT NOTIFICATION WILL BE | | GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING | | ASBESTOS REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE: | | HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE | | S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION- | | RENOVATION.HTML | | |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
2 |
Status |
P |
Date |
2023-02-13 |
|
|
Cont ID |
|
Sent By |
rrossano |
Date |
2023-02-13 |
Time |
|
Rev Time |
0.00 |
Received By |
rrossano |
Date |
2023-02-13 |
Time |
|
Sent To |
|
|
Notes |
2023-02-13 11:26:07 | PASSED WITH PROVISO: PLEASE PROVIDE ADDITIONAL | | DOCUMENTS AS REQUIRED BY BUILDING DEPT. |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
1 |
Status |
F |
Date |
2022-11-28 |
|
|
Cont ID |
|
Sent By |
rrossano |
Date |
2022-11-28 |
Time |
|
Rev Time |
|
Received By |
rrossano |
Date |
2022-11-28 |
Time |
|
Sent To |
|
|
Notes |
2022-11-28 09:32:53 | PLEASE PROVIDE STORMWATER POLLUTION PREVENTION PLAN | | SHOWN ON COPY OF PROPERTY SURVEY - SILT FENCE AROUND | | PROPERTY TO PREVENT DEBRIS RUNOFF; PROTECT ROADWAY FROM | | TRACKING OF DIRT FROM TRUCKS HAULING DEBRIS; PROTECT | | ANY STORM DRAIN INLETS IN VICINITY USING BEST | | MANAGEMENT PRACTICES (FILTER FABRIC, ETC.) | | | | PROVIDE ALL REQUIRED ASSOCIATED DOCUMENTS AS REQUIRED | | BY BUILDING DEPT. - STORMWATER POLLUTION PREVENTION | | PLAN, AND UTILITY SIGNOFFS - WATER/SEWER, PEST, FPL, | | FPU, ASBESTOS ETC. | | | | TO RESUBMIT, YOU MUST FIRST WAIT TILL ALL THE PLAN | | REVIEWS ARE COMPLETE. EVEN IF YOU FAILED ONE TRADE AND | | WANT TO ADDRESS THE COMMENTS IMMEDIATELY, YOU MUST WAIT | | FOR ALL OTHER TRADES TO REVIEW YOUR PLAN. RESUBMITTING | | BEFORE PLAN REVIEW IS COMPLETE WILL DELAY YOUR PLAN | | REVIEW TIME. | | | | ONCE ALL PLAN REVIEWS ARE COMPLETE, IF YOU DONT | | UNDERSTAND THE FAILED PLAN REVIEW COMMENTS, AS A BEST | | PRACTICE YOU SHOULD CALL OR EMAIL YOUR PLAN REVIEWER TO | | DISCUSS. EVERY PLAN REVIEWER INCLUDES THEIR NAME, PHONE | | AND EMAIL ADDRESS IN THE COMMENTS. TO VIEW YOUR PLAN | | REVIEW COMMENTS ONLINE, GO TO THE DEVELOPMENT SERVICES | | WEBSITE AT HTTPS://WWW.WPB.ORG/GOVERNMENT/DEVELOPMENT-S | | ERVICES/PERMITS AND SEE WHERE CAN I FIND MY PLAN REVIEW | | COMMENTS ONLINE? FOR INSTRUCTIONS. | | | | FOR QUESTIONS ABOUT HOW TO RESUBMIT, SEE INFO ON | | WEBSITE OR EMAIL [email protected] AND A BUILDING DIVISION | | TEAM MEMBER WILL HELP YOU. | | THANKS, | | RICK ROSSANO, SENIOR PROJECT COORD., WPB ENG. SERVICES | | DEPT., 561-494-1098, FAX: 561-494-1116 [email protected] | | FOR 24-HOUR EMERGENCY RESPONSE SERVICES TO PUBLIC | | UTILITIES, PUBLIC WORKS, PARKS, ETC. 561-822-2210 | | | | |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
P |
Date |
2022-11-28 |
|
|
Cont ID |
|
Sent By |
amhamilt |
Date |
2022-11-28 |
Time |
10:49 |
Rev Time |
0.00 |
Received By |
amhamilt |
Date |
2022-11-28 |
Time |
10:49 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2023-06-12 |
|
|
Cont ID |
|
Sent By |
aoliver |
Date |
2023-06-12 |
Time |
07:07 |
Rev Time |
0.00 |
Received By |
aoliver |
Date |
2023-06-02 |
Time |
10:34 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2023-02-27 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2023-02-27 |
Time |
09:07 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2023-02-10 |
Time |
07:27 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2022-12-07 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2022-12-07 |
Time |
09:33 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2022-11-22 |
Time |
07:21 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2023-02-27 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2023-02-27 |
Time |
09:06 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2023-02-24 |
Time |
15:33 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
P |
Date |
2022-12-07 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2022-12-07 |
Time |
09:32 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2022-12-07 |
Time |
09:32 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
F |
Date |
2023-06-09 |
|
|
Cont ID |
|
Sent By |
ckimmerl |
Date |
2023-06-09 |
Time |
14:51 |
Rev Time |
0.00 |
Received By |
ckimmerl |
Date |
2023-06-09 |
Time |
14:51 |
Sent To |
|
|
Notes |
2023-06-09 14:51:35 | [REPEAT COMMENT] | | | | PER SEC.94-107 | | EXISTING BUILDINGS MAY NOT BE DESTROYED OR REMOVED | | UNLESS THEY ARE TO BE REPLACED ACCORDING TO THESE URBAN | | REGULATIONS AND ONLY AFTER A BUILDING PERMIT WHICH | | AFFECTS THE VERTICAL CONSTRUCTION FOR THE NEW BUILDING | | HAS BEEN OBTAINED BY THE PROPERTY OWNER OR DEVELOPER. | | PERMITS WHICH AFFECT VERTICAL CONSTRUCTION INCLUDE THE | | FOUNDATION, VIBRO-FLOTATION, SOIL MIXING, PRESSURE | | GROUTING AND FULL BUILDING PERMITS. | | | | FOUNDATION PERMIT #22090680 NEEDS TO BE APPROVED FIRST. | | | | CHRIS KIMMERLY, AICP | | URBAN DESIGN PLANNER | | 822-1426 [email protected] |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2023-02-24 |
|
|
Cont ID |
|
Sent By |
ckimmerl |
Date |
2023-02-24 |
Time |
11:38 |
Rev Time |
0.00 |
Received By |
ckimmerl |
Date |
2023-02-24 |
Time |
11:37 |
Sent To |
|
|
Notes |
2023-02-24 11:38:27 | [REPEAT COMMENT] | | | | PER SEC.94-107 | | EXISTING BUILDINGS MAY NOT BE DESTROYED OR REMOVED | | UNLESS THEY ARE TO BE REPLACED ACCORDING TO THESE URBAN | | REGULATIONS AND ONLY AFTER A BUILDING PERMIT WHICH | | AFFECTS THE VERTICAL CONSTRUCTION FOR THE NEW BUILDING | | HAS BEEN OBTAINED BY THE PROPERTY OWNER OR DEVELOPER. | | PERMITS WHICH AFFECT VERTICAL CONSTRUCTION INCLUDE THE | | FOUNDATION, VIBRO-FLOTATION, SOIL MIXING, PRESSURE | | GROUTING AND FULL BUILDING PERMITS. | | | | FOUNDATION PERMIT #22090680 NEEDS TO BE APPROVED FIRST. | | | | CHRIS KIMMERLY, AICP | | URBAN DESIGN PLANNER | | 822-1426 [email protected] |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2022-12-06 |
|
|
Cont ID |
|
Sent By |
ckimmerl |
Date |
2022-12-06 |
Time |
16:11 |
Rev Time |
0.00 |
Received By |
ckimmerl |
Date |
2022-12-06 |
Time |
16:03 |
Sent To |
|
|
Notes |
2022-12-06 16:11:06 | PER SEC.94-107 | | EXISTING BUILDINGS MAY NOT BE DESTROYED OR REMOVED | | UNLESS THEY ARE TO BE REPLACED ACCORDING TO THESE URBAN | | REGULATIONS AND ONLY AFTER A BUILDING PERMIT WHICH | | AFFECTS THE VERTICAL CONSTRUCTION FOR THE NEW BUILDING | | HAS BEEN OBTAINED BY THE PROPERTY OWNER OR DEVELOPER. | | PERMITS WHICH AFFECT VERTICAL CONSTRUCTION INCLUDE THE | | FOUNDATION, VIBRO-FLOTATION, SOIL MIXING, PRESSURE | | GROUTING AND FULL BUILDING PERMITS. | | | | FOUNDATION PERMIT #22090680 NEEDS TO BE APPROVED FIRST. | | | | CHRIS KIMMERLY, AICP | | URBAN DESIGN PLANNER | | 822-1426 [email protected] |
|
|