Plan Review Stops For Permit 22110830 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2023-01-14 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2023-01-14 |
Time |
09:13 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2023-01-14 |
Time |
08:38 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2022-12-03 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2022-12-03 |
Time |
11:06 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2022-12-03 |
Time |
08:27 |
Sent To |
|
|
Notes |
2022-12-03 11:12:14 | 1ST BUILDING REVIEW | | RESULTS: CORRECTIONS NEEDED | | | | CHRISTOPHER S. THROOP, CBO, BN, PX, CFM | | PLANS EXAMINER II | | CITY OF WEST PALM BEACH | | (561) 805-6726 | | [email protected] | | | | CODES IN EFFECT: | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | NFPA 70 2017 EDITION NEC 2017 | | | | ADDRESS THE FOLLOWING COMMENTS AND RE-SUBMIT: | | | | 1.PROVIDE A COPY OF THE MOST RECENT BOUNDARY LINE | | SURVEY. | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | 107.2.5. | | | | 2. PROVIDE A SITE DRAINAGE PLAN PER FBC R401.3 | | IT SHALL BE DRAWN IN ACCORDANCE WITH AN ACCURATE AND | | INCLUDED BOUNDARY LINE SURVEY. | | | | 3. PROVIDE COVER SHEETS FOR THE WINDOW MULLION PRODUCT | | APPROVALS | | THE COVER SHEET PROVIDES THE APPROVAL NUMBER, CODE | | VERSION, AND STATUS, FBC R 301. | | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | | 4. DESIGNER SHALL SELECT MODEL OF DOUBLE HUNG WINDOW TO | | BE INSTALLED. | | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | | NOTICE: IF NON-IMPACT RATED WINDOWS ARE SELECTED, | | PROVIDE SCHEDULE OF OPENING PROTECTIVE DEVICES. | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2022-11-28 |
|
|
Cont ID |
|
Sent By |
mpeterso |
Date |
2022-11-28 |
Time |
11:28 |
Rev Time |
0.00 |
Received By |
mpeterso |
Date |
2022-11-28 |
Time |
10:40 |
Sent To |
|
|
Notes |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
4 |
Status |
P |
Date |
2023-02-28 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2023-02-28 |
Time |
07:22 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2023-02-28 |
Time |
07:07 |
Sent To |
|
|
Notes |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
3 |
Status |
F |
Date |
2023-02-16 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2023-02-16 |
Time |
13:28 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2023-02-16 |
Time |
12:41 |
Sent To |
|
|
Notes |
2023-02-16 13:28:47 | 3RD REVIEW FBC-2020 FUEL GAS | | PERMIT- 22110830 | | 2/16/23 | | | | CODES IN EFFECT: | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION | | 2020 | | FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) SHEETS P-1, P-4 & M-1: PLEASE REVISE THE GAS PIPING | | FLOOR PLAN AND RISER DRAWING SHOWING GAS PIPING TO A | | GAS FIREPLACE. THE REVISED M-1 DRAWING SHOWS AN | | EXISTING WOOD FIREPLACE. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. | | | | CHRISTOPHER L. COLE | | MECHANICAL/PLUMBING PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
2 |
Status |
F |
Date |
2023-01-10 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2023-01-10 |
Time |
09:35 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2023-01-10 |
Time |
07:48 |
Sent To |
|
|
Notes |
2023-01-10 09:40:15 | 2ND REVIEW FBC-2020 FUEL GAS | | PERMIT- 22110830 | | 1/19/23 | | | | CODES IN EFFECT: | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION | | 2020 | | FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | PLAN REVIEW RESULTS: DENIED. FAILED COMMENTS #3 & #4 | | FROM THE 1ST REVIEW ARE PRINTED BELOW WITH ADDITIONAL | | NOTES. PLEASE REVIEW THE COMMENTS AND CONTACT ME IF YOU | | HAVE QUESTIONS. | | | | 3) FAILED. P1 & P4: INDICATE HOW COMBUSTION AIR WILL BE | | PROVIDED TO THE RANGE AND FIREPLACE AND PROVIDE | | CALCULATIONS- SECTION G2407.1 FBC RES. THE CALCULATIONS | | ARE INCORREECT BASED ON THE FLOOR PLANS AND ELEVATION | | MEASUREMENTS SHOWN ON THE PLANS- REFER TO SHEETS A1.01, | | A3.01, & A3.02. USING THE STANDARD METHOD OF 50 CU. FT. | | PER 1000 BTUS, THE PLANS INDICATE A DEFICIENCY OF 956 | | CU. FT. OF VOLUME FOR THE COMBINED TOTAL 182,000 BTUS | | (RANGE 132,000 + FIREPLACE- 50,000). COMBUSTION AIR | | REQUIRED- 9100 CU. FT. SHEET A1.01 INDICATES FLOOR PLAN | | LENGTH AND WIDTH OF 39.66 X 25.66= 1018 SF. X 8 FT. | | HIGH CEILINGS= 8144 CU. FT. CONCERNING THE DRYER SEE | | SHEET A1.02, A3.01, A3.03. USING THE STANDARD METHOD | | 1000 CU. FT OF COMBUSTION AIR IS REQUIRED. THE ENCLOSED | | ROOM WITH DOOR PROVIDES 344 CU.FT. WHICH IS DEFICIENT, | | HOWEVER BASED ON SEC. G2407.1 EXCEPTION- TYPE 1 DRYERS | | CAN BE PROVIDED WITH MAKEUP AIR FOR EXHAUST IN | | COMPLIANCE WITH G2439.1. PLEASE CLARIFY HOW THE DRYER | | IS MEETING COMPLIANCE FOR MAKEUP AIR BASED ON SEC. | | G2439.5. IT APPEARS A JUMPER HAS BEEN INSTALLED HOWEVER | | THAT METHOD IS NOT IN COMPLIANCE WITH SEC. G2439.5 | | PRINTED BELOW. PLEASE NOTE SEC. G2439.1 SPECIFIES DRYER | | EXHAUST SYSTEM INCLUDING MAKEUP AIR SHALL BE IN | | ACCORDANCE WITH MAN. SPECS. | | | | G2439.5 (614.6) MAKEUP AIR. | | INSTALLATIONS EXHAUSTING MORE THAN 200 CFM (0.09 M3/S) | | SHALL BE PROVIDED WITH MAKEUP AIR. WHERE A CLOSET IS | | DESIGNED FOR THE INSTALLATION OF A CLOTHES DRYER, AN | | OPENING HAVING AN AREA OF NOT LESS THAN 100 SQUARE | | INCHES (0.0645 M2) FOR MAKEUP AIR SHALL BE PROVIDED IN | | THE CLOSET ENCLOSURE, OR MAKEUP AIR SHALL BE PROVIDED | | BY OTHER APPROVED MEANS. | | | | | | 4) FAILED. P1 & P4: PROVIDE A VENTING PLAN FOR THE | | FIREPLACE INCLUDING A VENTING DIAGRAM SHOWING THE TYPE | | AND SIZE OF VENT FLUE, VENT RUN LENGTH AND TERMINATION | | LOCATION- SECS. G2427.1 & G2434.1 & G2435.1 FBC RES. | | | | THE ENGINEER'S NARRATIVE REFERS TO SHEET M1 WHICH SHOWS | | THE FIRE PLACE VENT FLUE AS EXISTNG. I HAVE RESEACHED | | THE WPB BUILDING DEPT. PERMITTING RECORDS AND I WAS | | UNABLE TO FIND A PERMIT FOR A GAS FIREPLACE OR VENT | | FLUE. PLEASE PROVIDE THE REQUESTED INFORMATION BELOW. | | PLEASE NOTE THE VENTING SYSTEM SHALL BE IN COMPLIANCE | | WITH THE MANUFACTURER'S GUIDELINES PER SEC. G2427.1 FBC | | RES. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. | | | | CHRISTOPHER L. COLE | | MECHANICAL/PLUMBING PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | | | | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
F |
Date |
2022-11-22 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2022-11-22 |
Time |
12:37 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2022-11-22 |
Time |
12:37 |
Sent To |
|
|
Notes |
2022-11-22 12:50:31 | 1ST REVIEW FBC-2020 FUEL GAS | | PERMIT- 22110830 | | 11/22/22 | | | | CODES IN EFFECT: | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION | | 2020 | | FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) SHEETS P1 & P4: A SEPARATE PERMIT IS REQUIRED FOR | | INSTALLATION OF THE GENERATOR. PLEASE LABEL THE | | GENERATOR AS "FUTURE GENERATOR"ON THE PLANS AND PROVIDE | | A GAS-TIGHT CAP FOR THE SUPPLY PIPE- SEC. 107.2.1 WPB, | | AND SEC. G2415.15 FBC RES. | | | | 3) P1 & P4: INDICATE HOW COMBUSTION AIR WILL BE | | PROVIDED TO THE RANGE AND FIREPLACE AND PROVIDE | | CALCULATIONS- SECTION G2407.1 FBC RES. | | | | 4) P1 & P4: PROVIDE A VENTING PLAN FOR THE FIREPLACE | | INCLUDING A VENTING DIAGRAM SHOWING THE TYPE AND SIZE | | OF VENT FLUE, VENT RUN LENGTH AND TERMINATION LOCATION- | | SECS. G2427.1 & G2434.1 & G2435.1 FBC RES. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. | | | | CHRISTOPHER L. COLE | | MECHANICAL/PLUMBING PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | | | | | |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
P |
Date |
2022-11-28 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2022-11-28 |
Time |
17:08 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2022-11-28 |
Time |
17:08 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2023-02-28 |
Time |
|
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2023-02-27 |
Time |
08:01 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2023-02-16 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2023-02-16 |
Time |
15:44 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2023-02-15 |
Time |
16:20 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2023-02-15 |
|
|
Cont ID |
|
Sent By |
aoliver |
Date |
2023-02-15 |
Time |
09:25 |
Rev Time |
0.00 |
Received By |
aoliver |
Date |
2023-01-09 |
Time |
15:55 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2022-12-03 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2022-12-03 |
Time |
11:12 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2022-11-21 |
Time |
08:01 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
P |
Date |
2023-02-10 |
|
|
Cont ID |
|
Sent By |
aoliver |
Date |
2023-02-10 |
Time |
08:32 |
Rev Time |
0.00 |
Received By |
aoliver |
Date |
2023-02-07 |
Time |
09:01 |
Sent To |
|
|
Notes |
2023-02-09 13:01:54 | RECEIPT MU 2023-005635-0000 - $546.52 PAID -AO | 2023-02-07 09:01:24 | 2/7/23 EMAILED IMPACT OFFICE FOR REVIEW. LEM |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2022-12-03 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2022-12-03 |
Time |
09:00 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2022-12-03 |
Time |
09:00 |
Sent To |
|
|
Notes |
2022-12-03 09:01:15 | IMPACT FEES | | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | DIGITALLY VIA PROJECT DOX UPON NOTIFICATION BY THIS | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON | | APPROVAL AND FEE PAYMENT (IF ANY), PLEASE UPLOAD THE | | RECEIPT TO YOUR PROJECT OR EMAIL IT TO | | [email protected] . | | | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2023-02-16 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2023-02-16 |
Time |
15:43 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2023-02-16 |
Time |
14:49 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2023-01-10 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2023-01-10 |
Time |
12:33 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2023-01-10 |
Time |
12:33 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2022-11-28 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2022-11-28 |
Time |
07:21 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2022-11-28 |
Time |
07:21 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
4 |
Status |
P |
Date |
2023-02-28 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2023-02-28 |
Time |
07:22 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2023-02-28 |
Time |
07:07 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2023-02-16 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2023-02-16 |
Time |
13:12 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2023-02-16 |
Time |
11:37 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2023-01-10 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2023-01-10 |
Time |
09:35 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2023-01-10 |
Time |
07:47 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2022-11-22 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2022-11-22 |
Time |
12:36 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2022-11-22 |
Time |
11:50 |
Sent To |
|
|
Notes |
2022-11-22 12:37:17 | 1ST REVIEW FBC-2020 RES. PLUMBING | | PERMIT- 22110830 | | 11/22/22 | | | | CODES IN EFFECT: | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION | | 2020 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) SHEETS P1 & P4: CLEANOUTS ARE REQUIRED AT THE | | JUNCTIONS OF THE BUILDING DRAINS AND SEWER SHOWN AT THE | | WEST SIDE OF THE HOUSE- SECS. P 3005.2.3 FBC RES. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. | | | | CHRISTOPHER L. COLE | | MECHANICAL/PLUMBING PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | | | |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
2 |
Status |
P |
Date |
2023-01-14 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2023-01-14 |
Time |
09:13 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2023-01-14 |
Time |
08:38 |
Sent To |
|
|
Notes |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
F |
Date |
2022-12-03 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2022-12-03 |
Time |
10:58 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2022-12-03 |
Time |
08:27 |
Sent To |
|
|
Notes |
2022-12-03 11:06:12 | PLAN REVIEW ROOFING | | | | 1ST ROOFING REVIEW | | RESULTS: CORRECTIONS NEEDED | | | | CHRISTOPHER S. THROOP, CBO, BN, PX, CFM | | PLANS EXAMINER II | | CITY OF WEST PALM BEACH | | (561) 805-6726 | | [email protected] | | | | CODES IN EFFECT: | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | NFPA 70 2017 EDITION NEC 2017 | | | | ADDRESS THE FOLLOWING COMMENTS AND RE-SUBMIT: | | | | NOTICE: REFERENCE FL16443-R24, SINGLE PLY TPO (93 PG'S) | | FOR THE FOLLOWING COMMENT: | | | | 1. DESIGNER SHALL SELECT SYSTEM TO BE INSTALLED. | | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | | NOTICE: GENERAL LIMITATIONS # 5.7.2 AND GENERAL NOTE # | | 9 MAY APPLY. (ENHANCHED FASTENER CALC'S) | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
4 |
Status |
P |
Date |
2023-02-28 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2023-02-28 |
Time |
07:23 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2023-02-28 |
Time |
07:07 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
3 |
Status |
P |
Date |
2023-02-16 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2023-02-16 |
Time |
13:17 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2023-02-16 |
Time |
12:42 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2023-01-14 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2023-01-14 |
Time |
09:13 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2023-01-14 |
Time |
08:38 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
P |
Date |
2022-11-28 |
|
|
Cont ID |
|
Sent By |
mpeterso |
Date |
2022-11-28 |
Time |
11:32 |
Rev Time |
0.00 |
Received By |
mpeterso |
Date |
2022-11-28 |
Time |
11:32 |
Sent To |
|
|
Notes |
2022-11-28 11:33:12 | ALL PLANS PASSED SIGNATURE REVIEW. MP | 2022-11-22 13:42:32 | PLUMBING DIG/SIG PASSED. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
N |
Date |
2023-02-14 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2023-02-14 |
Time |
15:13 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2023-02-14 |
Time |
15:13 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2022-11-28 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2022-11-28 |
Time |
17:08 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2022-11-28 |
Time |
17:08 |
Sent To |
|
|
Notes |
|
|