Plan Review Details - Permit 22110296
Plan Review Stops For Permit 22110296
Review Stop AD ADDRESSING
Rev No 1 Status P Date 2022-12-13 Cont ID  
Sent By cpuell Date 2022-12-13 Time 16:45 Rev Time 0.00
Received By cpuell Date 2022-12-13 Time 16:45 Sent To  
Notes
2022-12-13 16:46:51HALF ADDRESS ISSUES ADDRESSED UNDER 22061676

Review Stop G GAS REVIEW
Rev No 2 Status P Date 2023-02-10 Cont ID  
Sent By ccole Date 2023-02-10 Time 08:32 Rev Time 0.00
Received By ccole Date 2023-02-10 Time 07:55 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2023-02-07 Cont ID  
Sent By ccole Date 2023-02-07 Time 14:30 Rev Time 0.00
Received By ccole Date 2023-02-07 Time 13:00 Sent To  
Notes
2023-02-07 14:30:511ST REVIEW FBC-2020 RES. GAS
 PERMIT- 22110296
 2/7/23
  
 CODES IN EFFECT:
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION
 2020
 FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) GAS RISER: THE 1/2-INCH GALVANIZED PIPE TO THE
 GENERATOR SHALL BE INCREASED IN SIZE TO MINIMUM
 3/4-INCH- TABLE G2413.4(2) FBC RES.
  
 2) GAS RISER: SHOW THE TYPE AND SIZE OF PIPE FROM THE
 1-INCH PE TO THE EXISTING TANKLESS WATER HEATER- SEC.
 G2413.3 FBC RES.
  
 3) GAS RISER: PLEASE SHOW THE EHD OF THE CSST PIPING-
 SEC. G2413.3 FBC RES.
  
 4) SHEET P1.0: THE MARKED-UP PLAN WILL REQUIRE THE
 DIGITAL SIGNATURE AND SEAL OF THE REGISTERED ARCHITECT-
 FL STATUTE 481.221 AND SEC. 61G1-16.005 FAC. THE
 CONTRACTOR WHO PUT THE MARKINGS ON THE PLAN MAY SUBMIT
 HIS OWN FLOOR PLAN SKETCH TO SHOW THE APPLIANCE AND
 PIPING LOCATIONS- SEC. 107.2.1 WPB.
  
 5) P1.0: THE GENERATOR IS UNDER SEPARATE PERMIT REVIEW
 HOWEVER PLEASE NOTE THAT THE GENERATOR EXHAUST SHALL BE
 A MINIMUM OF 10 FT. FROM GRAVITY AND MECHANICAL AIR
 INTAKES INTO THE BUILDING- R303.5.1 FBC RES.
  
 6) P1.0: PROVIDE COMBUSTION AIR CALCULATIONS FOR THE
 RANGE PER SEC. G2407.1 FBC RES. PLEASE NOTE A TOTAL OF
 3475 CU. FT OF OPEN AIR IS REQUIRED FOR THE 69,500 BTU
 RANGE IF USING THE INDOOR VOLUME OF THE SPACE.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date   Cont ID  
Sent By   Date 2023-02-10 Time   Rev Time 0.00
Received By aoliver Date 2023-02-09 Time 07:46 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2023-02-07 Time   Rev Time 0.00
Received By amcgrego Date 2023-02-03 Time 13:39 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status N Date 2023-02-10 Cont ID  
Sent By ccole Date 2023-02-10 Time 08:32 Rev Time 0.00
Received By ccole Date 2023-02-10 Time 07:56 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status N Date 2023-02-07 Cont ID  
Sent By ccole Date 2023-02-07 Time 14:31 Rev Time 0.00
Received By ccole Date 2023-02-07 Time 13:00 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2023-02-10 Cont ID  
Sent By ccole Date 2023-02-10 Time 08:33 Rev Time 0.00
Received By ccole Date 2023-02-10 Time 07:56 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2023-02-07 Cont ID  
Sent By ccole Date 2023-02-07 Time 14:30 Rev Time 0.00
Received By ccole Date 2023-02-07 Time 13:00 Sent To  
Notes
***NONE***