Plan Review Details - Permit 22110228
Plan Review Stops For Permit 22110228
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2023-02-15 Cont ID  
Sent By jwitmer Date 2023-02-15 Time 07:22 Rev Time 0.00
Received By jwitmer Date 2023-02-15 Time 06:46 Sent To  
Notes
2023-02-15 07:22:30WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION
 SERVICES/ BUILDING DIVISION
 2020 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 22110228
 ADD: 530 NOTTINGHAM BLVD.
 CONT: R D BROCKMAN
 TEL: 561-719-3702
 E-MAIL: [email protected]
  
 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: WED. FEB.15/2023
 ACTION: DENIED
  
 1) THE VALUE OF THE PROJECT IS EXTREMELY LOW.
 2020 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING
 CODE, CHAPTER 1, ADMINISTRATION 109.3 BUILDING PERMIT
 VALUATION. IF, IN THE OPINION OF THE BUILDING OFFICIAL,
 THE CLAIMED VALUATION OF AWNING PERMIT APPEARS TO BE
 UNDERESTIMATED ON THE APPLICATION, THE PERMIT SHALL BE
 DENIED. FOR PERMITTING PURPOSES, VALUATION OF BUILDINGS
 AND SYSTEMS SHALL BE TOTAL REPLACEMENT PURPOSES,
 VALUATION OF THE AWNING PERMIT. VALUATION REFERENCES
 MAY INCLUDE THE LATEST PUBLISHED DATA OF NATIONAL
 CONSTRUCTION COST ANALYSIS SERVICES (MARSHALL-SWIFT,
 MEANS, ETC.) WITH REGIONAL ADJUSTMENTS FOR LOCATION AS
 PUBLISHED BY THE INTERNATIONAL CODE CONGRESS.
  
 2) NO SITE PLAN OR SURVEY WAS SUBMITTED SHOWING THE
 LOCATION WHERE WORK IS T OCCUR. 2020 W. P. B.
 ADMINISTRATIVE CODE107.3.5 MINIMUM PLAN REVIEW CRITERIA
 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATIVE CODE SECTION:
 107.3.5 MINIMUM PLAN REVIEW CRITERIA FOR BUILDINGS AND
 OR STRUCTURES.
 107.3.5.1 COMMERCIAL BUILDINGS
 107.3.5.1.1. BUILDING
 MISSING CODE DATA:
 SURVEY/ SITE PLAN
 WIND DESIGN CRITERIA/ ASSOCIATED PRESSURES
  
 3) THE SUBMITTED PRODUCT SPEC SHEET IS JUST THAT, THERE
 IS NO ENGINEERING SHOWING THE WIND DESIGN, VERTICAL
 SUPPORTS NOR FOOTINGS AND ANCHORING OF VERTICAL
 SUPPORTS TO THE FOUNDATION. THERE APPEARS TO BE AN
 ADDITIONAL SIDE SCREEN LOAD ADDED TO THE RIGID FRAME
 AWNING AGAIN NO ENGINEERING. RIGID AWNING. PERMANENT OR
 NON-REMOVABLE FABRIC. FBC-B 3105.4.2.2. THE WIND DESIGN
 LOADS FOR ANY FABRIC OR MEMBRANE COVERED STRUCTURE
 DESIGNED WITH A PERMANENT OR NON-REMOVABLE FABRIC OR
 MEMBRANE, SHALL BE BASED ON THE FOLLOWING CRITERIA:
 1) MINIMUM WIND SPEED VELOCITY AS REQUIRED IN CHAPTER
 16 USING FIGURE 1609.3(3) 150 VULT, CATEGORY 1
 BUILDINGS.
  
 4) COMPONENTS & CLADDING. PLEASE SUBMIT THE COMPONENTS
 AND CLADDING PRODUCT APPROVALS. 2020 FBC-B,
 1609.6.4.4.1 COMPONENTS & CLADDING. FLORIDA DEPARTMENT
 OF COMMUNITY AFFAIRS, ADMINISTRATIVE CODE 61G20-3.005,
 RULE 9N-3 NOV. 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS
 OR CONSTRUCTION SYSTEMS THAT WILL REQUIRE PRODUCT
 APPROVALS:
 (31)(D) ROOFING PRODUCTS
  
 5) A TRANSMITTAL LETTER / NARRATIVE LISTING THE
 ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF
 THE REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL
 HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR
 ANTICIPATED COOPERATION.
  
 PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS
 REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT
 REVIEW CYCLE.
 PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS
 REVIEW, SUBSEQUENT
 REMARKS MAYBE MADE IN THE NEXT REVIEW CYCLE.
  
  
 MY WORK HOURS ARE USUALLY TUES. & WED. 7:30 AM- 4:30 PM
 PART-TIME/ SEMI-RETIRED.
  
 IF YOU WISH TO SPEAK WITH A PLANS EXAMINER BEFORE I GET
 BACK INTO THE OFFICE CALL
 (561)805-6700 AND ASK FOR THE PLANS EXAMINER ON-CALL.
 THANK YOU.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  
  
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2023-02-15 Cont ID  
Sent By cwalker Date 2023-02-15 Time   Rev Time  
Received By cwalker Date   Time   Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2023-02-28 Cont ID  
Sent By lmarchan Date 2023-02-28 Time 08:05 Rev Time 0.00
Received By lmarchan Date 2022-11-04 Time 09:41 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status N Date 2023-02-15 Cont ID  
Sent By jwitmer Date 2023-02-15 Time 07:22 Rev Time  
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2023-02-27 Cont ID  
Sent By ASangele Date 2023-02-27 Time 08:18 Rev Time 0.00
Received By asangele Date 2023-02-27 Time 08:18 Sent To  
Notes
2023-02-27 08:22:44FAILED
 2/27/2023
  
 PLEASE PROVIDE A PROPERTY SURVEY AND DEMONSTRATE WHERE
 ON THE PROPERTY THE AWNING WILL BE LOCATED.
  
 ALEXIS SANGELEER
 PLANNER
 [email protected]