Plan Review Details - Permit 22110148
Plan Review Stops For Permit 22110148 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2023-02-13 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2023-02-13 |
Time |
15:15 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2023-02-13 |
Time |
13:43 |
Sent To |
|
|
Notes |
2023-02-13 15:17:50 | 1ST BUILDING REVIEW | | RESULTS: CORRECTIONS NEEDED | | | | CHRISTOPHER S. THROOP, CBO, BN, PX, CFM | | PLANS EXAMINER II | | CITY OF WEST PALM BEACH | | (561) 805-6726 | | [email protected] | | | | CODES IN EFFECT: | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | NFPA 70 2017 EDITION NEC 2017 | | | | ADDRESS THE FOLLOWING COMMENTS AND RE-SUBMIT: | | | | 1. PROPERTY IS LOCATED IN A SPECIAL FLOOD HAZARD AREA | | (SFHA). ELEVATION CERTIFICATES ARE REQUIRED. | | SEE COMMENTS UNDER NFIP REVIEW. | | | | 2. PROVIDE A SITE DRAINAGE PLAN PER FBC R401.3 | | IT SHALL BE DRAWN IN ACCORDANCE WITH AN ACCURATE AND | | INCLUDED BOUNDARY LINE SURVEY. | | FBC R401.3 SITE DRAINAGE | | | | 3.PROVIDE A COPY OF THE CURRENT FLORIDA PRODUCT | | APPROVALS APPROVED UNDER THE 2020 FBC, FOR THE PROPOSED | | WINDOW AND OVERHEAD DOOR (OHD). | | FL PRODUCT APPROVALS SHALL INCLUDE THE COVER SHEETS, | | EVALUATION REPORT AND INSTALLATIONS INSTRUCTIONS. | | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | | 4.PROVIDE A WINDOW AND DOOR FLASHING DETAIL OR THE | | SPEC. SHEET OF A FLUID APPLIED MEMBRANE. | | R703.4 | | | | 5.PROVIDE LOCATION OF ATTIC ACCESS PER R807.1.7. | | | | 6. IF SMART VENTS ARE UTILIZED FOR FLOOD OPENINGS, | | PROVIDE THE FLORIDA PRODUCT APPROVALS AND THE ICC-ES | | REPORT. IDENTIFY WHICH VENTS WILL BE INSTALLED. LOCATE | | TYPE OF VENTS WITH MODEL NUMBER ON FLOOR PLAN. | | 107.2 CONSTRUCTION DOCUMENTS SHALL BE IN ACCORDANCE | | WITH SECTIONS107.2.1 THROUGH 107.2.5. | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. | | | | | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2023-02-10 |
|
|
Cont ID |
|
Sent By |
rperdomo |
Date |
2023-02-10 |
Time |
12:52 |
Rev Time |
0.00 |
Received By |
rperdomo |
Date |
2023-02-10 |
Time |
12:08 |
Sent To |
|
|
Notes |
2023-02-10 12:52:04 | FLORIDA BUILDING CODE 2020 7TH EDITION | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED | | NFPA 70 2017 EDITION | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW | | | | 1. PROVIDE LOAD CALCULATION FOR SERVICE, INCLUDE | | EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF SERVICE | | IS ADEQUATE. NEC 220 | | 2, PROVIDE INFORMATION OF SERVICE, INCLUDING PROTECTION | | AND GROUNDED CONDUCTOR. NEC 230, 240, 250.102(C) | | 2. PROVIDE INFORMATION OF THE PANEL SCHEDULE. NEC | | 408.4(A) | | 3. PROVIDE INFORMATION OF THE NEW FEEDERS, CIRCUITS AND | | EGC TO BE INSTALLED. NEC 220, 250.122 | | 4. RECEPTACLES INSTALLED IN GARAGES MUST PROVIDE GFCI | | PROTECTION. NEC 208(A)(2) | | | | END OF COMMENTS | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM. | | | | RUBEN PEREZ PERDOMO, P.E. | | ELECTRICAL PLANS EXAMINER | | 561-805-6738 | | [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2023-02-16 |
|
|
Cont ID |
|
Sent By |
avolcy |
Date |
2023-02-16 |
Time |
16:13 |
Rev Time |
0.00 |
Received By |
avolcy |
Date |
2023-02-02 |
Time |
10:14 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2023-02-13 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2023-02-13 |
Time |
13:47 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2023-02-13 |
Time |
13:43 |
Sent To |
|
|
Notes |
2023-02-13 13:48:20 | IMPACT FEES | | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | DIGITALLY VIA PROJECT DOX UPON NOTIFICATION BY THIS | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON | | APPROVAL AND FEE PAYMENT (IF ANY), PLEASE UPLOAD THE | | RECEIPT TO YOUR PROJECT OR EMAIL IT TO | | [email protected] . | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
N |
Date |
2023-02-06 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2023-02-06 |
Time |
13:48 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2023-02-06 |
Time |
13:48 |
Sent To |
|
|
Notes |
2023-02-06 13:48:48 | NO MECHANICAL WORK SHOWN FOR THIS NEW GARAGE. ME |
|
|
Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
Rev No |
1 |
Status |
F |
Date |
2023-02-13 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2023-02-13 |
Time |
15:09 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2023-02-13 |
Time |
13:43 |
Sent To |
|
|
Notes |
2023-02-13 15:14:32 | 1ST NFIP REVIEW | | RESULTS: CORRECTIONS NEEDED | | | | CHRISTOPHER S. THROOP, CBO, BN, PX, CFM | | PLANS EXAMINER II | | CITY OF WEST PALM BEACH | | (561) 805-6726 | | [email protected] | | | | CODES IN EFFECT: | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | CITY ORDINANCE NO. 4658-16 AND NO. 4729-17 | | FEMA DESK REFERENCE P 758 | | FBC R322 FLOOD-RESISTANT CONSTRUCTION | | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1.THIS PROJECT IS LOCATED IN A SPECIAL FLOOD HAZARD | | AREA (SFHA). THE FLOOD ZONE DESIGNATION FOR THIS SITE | | IS AE 6 WITH A BASE FLOOD ELEVATION (BFE) OF 6.0' NAVD. | | THE CITY OF WEST PALM BEACH (THROUGH ORDINANCE NO. | | 4729-17) REQUIRES AN ADDITIONAL 24 INCHES OF FREEBOARD. | | THE DESIGN FLOOD ELEVATION (DFE) SHALL BE AT OR ABOVE | | 9.0' NAVD. | | | | CITY OF WEST PALM BEACH, FLORIDA ORDINANCE NO. 4729-17 | | SECTION 4: THE CODE OF ORDINANCES IS HEREBY AMENDED AT | | CHAPTER 18, BUILDINGS AND BUILDING REGULATIONS, ARTICLE | | II, BUILDING CODE, TO ADD SECTION 18-33, TECHNICAL | | AMENDMENTS TO FLORIDA BUILDING CODE, RESIDENTIAL, WHICH | | SHALL READ AS FOLLOWS: | | | | SEC. 18-33 - TECHNICAL AMENDMENTS TO FLORIDA BUILDING | | CODE, RESIDENTIAL. | | R322.2.1 ELEVATION REQUIREMENTS. | | | | 1.BUILDINGS AND STRUCTURES IN FLOOD HAZARD AREAS NOT | | DESIGNATED AS COASTAL A ZONES SHALL HAVE THE LOWEST | | FLOORS ELEVATED TO OR ABOVE THE BASE FLOOD ELEVATION | | PLUS ONE FOOT, OR THE DESIGN FLOOD ELEVATION, WHICHEVER | | IS HIGHER. (PLUS TWO FEET PER CITY ORDINANCE 4729-17). | | | | 2. PROVIDE THE FOLLOWING (3) ELEVATION CERTIFICATES AS | | REQUIRED. | | | | A CONSTRUCTION DRAWING ELEVATION CERTIFICATE IS | | REQUIRED AT TIME OF PERMIT APPLICATION. | | | | A BUILDING UNDER CONSTRUCTION ELEVATION CERTIFICATE IS | | REQUIRED AT PLACEMENT OF 1ST FLOOR. | | | | A FINISHED CONSTRUCTION ELEVATION CERTIFICATE IS | | REQUIRED AND SHALL BE SUBMITTED FOR REVIEW AND APPROVAL | | PRIOR TO THE ISSUANCE OF THE CERTIFICATE OF OCCUPANCY. | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. | | | | | | | | | | | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2023-02-09 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2023-02-09 |
Time |
13:56 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2023-02-09 |
Time |
11:58 |
Sent To |
|
|
Notes |
2023-02-09 13:57:14 | 1ST REVIEW FBC-2020 RES. PLUMBING | | PERMIT- 22110148 | | 2/8/2023 | | | | CODES IN EFFECT: | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION | | 2020 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) SHEET A1.1: PROVIDE POOL PLUMBING ALTERATION PLANS | | INCLUDING AN UNDERGROUND PIPING LAYOUT PLAN SHOWING THE | | NEW PIPING POINTS OF CONNECTIONS TO EXISTING PRESSURE | | AND SUCTION PIPING, AND NEW PIPING RUNS TO RELOCATED | | EQUIPMENT. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. | | | | CHRISTOPHER L. COLE | | MECHANICAL/PLUMBING PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
N |
Date |
2023-02-13 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2023-02-13 |
Time |
13:49 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2023-02-13 |
Time |
13:43 |
Sent To |
|
|
Notes |
2023-02-13 13:50:26 | PROVISO ON PLAN PAGE S-2: A SEPERATE ROOFING PERMIT IS | | REQUIRED. CT |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2023-02-13 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2023-02-13 |
Time |
15:14 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2023-02-13 |
Time |
13:43 |
Sent To |
|
|
Notes |
2023-02-13 15:15:28 | 1ST SIGNATURE REVIEW | | RESULTS: CORRECTIONS NEEDED | | | | CHRISTOPHER S. THROOP, CBO, BN, PX, CFM | | PLANS EXAMINER II | | CITY OF WEST PALM BEACH | | (561) 805-6726 | | [email protected] | | | | CODES IN EFFECT: | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | NFPA 70 2017 EDITION NEC 2017 | | | | ADDRESS THE FOLLOWING COMMENTS AND RE-SUBMIT: | | | | NOTICE: ALL PLAN PAGES | | | | 1.DOCUMENTS PREPARED BY AN ARCHITECT OR ENGINEER AND | | SUBMITTED ELECTRONICALLY FOR PUBLIC RECORD SHALL HAVE A | | VALID DIGITAL SIGNATURE. | | A SCAN OF A WET SEAL AND SIGNATURE OR DIGITAL SIGNATURE | | IS NOT CONSIDERED A VALID DIGITAL SIGNATURE. | | | | 2.SUBMIT PLANS WITH A VALID DIGITAL SIGNATURE PER F.S. | | 668.003 (3); | | FBC 107.2.1 ALL INFORMATION, DRAWINGS, SPECIFICATIONS | | AND ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE | | OF THE PERSON RESPONSIBLE FOR THE DESIGN. (SEE ALSO | | SECTION 107.3.5). | | F.S. 471; F.A.C. 61G15-23.005 (ENGINEERS) | | F.S. 481; F.A.C. 61G1-16.005 (ARCHITECTS) | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2023-02-16 |
|
|
Cont ID |
|
Sent By |
AVolcy |
Date |
2023-02-16 |
Time |
16:04 |
Rev Time |
0.00 |
Received By |
avolcy |
Date |
2023-02-16 |
Time |
16:04 |
Sent To |
|
|
Notes |
2023-02-16 16:11:40 | 02.16.2023 - FAILED | | GARAGE LAYOUT IS OK. | | | | SETBACK FOR MECHANICAL/POOL EQUIPMENT FOR THIS FRONT | | YARD IS 21. MECHANICAL EQUIPMENT CANNOT ENCROACH MORE | | THAN 4FT INTO THE REQUIRED SETBACK. | | UPDATE PLANS TO REFLECT THIS REQUIREMENT. | | | | SEPARATE PERMIT REQUIRED FOR: | | FENCE/WALL, DRIVEWAY, POOL, GENERATOR, | | MECHANICAL/AC/POOL EQUIPMENT, IRRIGATION, LANDSCAPE, | | ACCESSORY STRUCTURE, OTHER | | | | GAISHA (ANNE CLERISSE) VOLCY | | [email protected] |
|
|
|